  • GE IC693MDL655 DC Positive/Negative Logic Input module
    ❤ Add to collection
  • GE IC693MDL655 DC Positive/Negative Logic Input module

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IC693MDL655 DC Positive/Negative Logic Input module

    • ¥12000.00
      ¥24520.00
      ¥12000.00
      ¥12000.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.600KG
    • Quantity:
    • (Inventory: 33)
Description

GE IC693MDL655 DC Positive/Negative Logic Input module


GE IC693MDL655 DC Positive/Negative Logic Input module

DESCRIPTION

The 24 volt DC Positive/Negative Logic Input module for the Series 90-30 Programmable Logic Controller provides 32 discrete  input points.  The inputs are arranged in four isolated groups of eight (A1 - A8, B1 - B8, C1 - C8, and D1 - D8); each group has its own common. The inputs are positive or negative logic inputs and will operate at levels up to 30V. Backplane isolation between the field side and logic side is provided by opto-couplers on the module.  Isolation is also provided between the four groups of inputs on the module, however each group of eight inputs is  referenced to the same user common connection.  There are no special fault or alarm diagnostics reported.  LED indicators (labeled A1 - A8, B1 - B8, C1 - C8, D1 - D8) at the top of the module provide the ON/OFF status of each input point.

Functionality and Features

Dual - Logic Input Signal Reception

The module can receive both DC positive and negative logic input signals. This flexibility allows it to interface with a wide range of sensors and other input devices that may use different logic - level conventions. For example, it can handle positive - logic signals from devices like push - buttons and proximity sensors, as well as negative - logic signals from other specialized sensors or legacy equipment. The input voltage ranges for both positive and negative logic are carefully defined to ensure accurate signal detection and processing.

Signal Conditioning and Filtering

Similar to other input modules, the IC693MDL655 incorporates signal - conditioning circuitry. This circuitry is responsible for filtering out electrical noise and interference that could affect the integrity of the input signals. By reducing noise, the module provides more reliable input data to the control system. It may also include amplification or attenuation functions to adjust the input - signal strength to an appropriate level for internal processing.

Input Signal Protection Mechanisms

To safeguard against electrical faults, the module is equipped with various protection mechanisms. It has over - voltage protection to prevent damage from voltage spikes or incorrect voltage levels. Over - current protection is also in place to limit the current flowing through the input channels in case of a short - circuit or other abnormal current - draw conditions. Additionally, reverse - polarity protection ensures that the module can withstand incorrect wiring without being damaged.

Input State Monitoring and Reporting

The module continuously monitors the state of each input signal. It can quickly detect changes in the logic state, whether from positive to negative or vice - versa. Once a change is detected, it reports this information to the connected control system in a timely manner. The reporting is usually done through a digital communication interface, allowing the control system to respond appropriately based on the input - signal changes.

Compatibility and Integration with Control Systems

The IC693MDL655 is designed to be easily integrated into GE's industrial - control - system architecture and other compatible systems. It has a standard communication interface that enables seamless data transfer between the module and the control system's central processing unit. This allows the input - signal data to be used in control - logic programs, decision - making processes, and other system - level operations.

Technical Specifications

Input - Signal Specifications

Positive - Logic Inputs: The module defines the voltage range for positive - logic input signals, such as 10 - 30V DC. The logic - high and logic - low thresholds are precisely specified, for example, a logic - high might be recognized at 18V and above, and a logic - low at 10V and below. The number of positive - logic input channels is also provided, which could be a specific number like 16 or 32.

Negative - Logic Inputs: For negative - logic inputs, the voltage range might be specified as - 30V to - 10V DC. The logic - high and logic - low thresholds are adjusted accordingly, with a logic - high recognized at - 10V and above (in the negative - voltage context), and a logic - low at - 30V and below. The number of negative - logic input channels is typically the same as or different from the positive - logic channels, depending on the module's design.

Input - Impedance: The input - impedance values for both positive and negative - logic input channels are important parameters that affect the loading on the input - signal sources.

Protection - Specifications

Over - Voltage Protection: The maximum - over - voltage the module can handle for both positive and negative - logic inputs is specified. The protection - mechanism details, such as the use of transient - voltage - suppressor components or other protective circuits, are provided.

Over - Current Protection: The maximum - allowable - current through each input channel is defined, along with the over - current - protection method, such as current - limiting resistors or self - resetting fuses.

Reverse - Polarity Protection: The module's ability to withstand reverse - polarity conditions for both positive and negative - logic inputs is described, along with the associated protection - circuitry, such as reverse - polarity - protection diodes.

Communication - Interface Specifications

The module uses a specific communication interface to interact with the control system. The supported communication protocol, such as the GE Genius Bus or other protocols, is specified. The data - transfer - rate capabilities, the number of supported - connections, and the physical - connection requirements (e.g., pin - configuration) are also provided.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • OMRON NX502 CPU Unit Hardware Installation and Maintenance Guide
  • OMRON NX102 Hardware Installation Guide
  • OMRON C200HX/HG/HE PLC Troubleshooting
  • Yamatake SDC35/36 Controller Application Guide
  • MITSUBISHI ELECTRIC GT25 Human Computer Interface Application Guide
  • Eurotherm Mini8 Controller Integration Guide
  • KEYENCE GC-1000 Safety Controller Manual
  • SICK RLY3-EMSS300 Safety Relay Manual
  • Troubleshooting of Siemens SIRIUS 3SK2 Safety Relay
  • Nordson DAGE4000 Bond Tensile Tester
  • HMS Anybus Communicator Gateway Replacement and Troubleshooting Guide
  • Allen Bradley 800T/H 30mm Button Troubleshooting and Replacement Guide
  • Schneider Modicon M340 Strict Environment Deployment and Troubleshooting Guide
  • Kepco BOP 1000M Troubleshooting Application
  • Siemens SIPROTEC 5 Replacement and Upgrade Guide
  • Banner XS/SC26 Security Controller Debugging and Troubleshooting
  • Allen Bradley MicroLogix 1500 Installation and Debugging
  • EOCR-PMZ (panel embedded) and EOCR-PFZ (embedded) motor comprehensive protector
  • Microchip PIC16F182X Low Power Design
  • FANUC α iS servo HRV calibration practice
  • Mitsubishi Electric GT23 Series HMI Maintenance Guide
  • Mitsubishi GT27 HMI Application Guide
  • Siemens SIMATIC ET 200M Selection
  • Lenze 8200 Vector Selection
  • Troubleshooting of Siemens MASTER DRIVES VC
  • FANUC I/O Unit A Maintenance Manual
  • Allen Bradley PLC-5 Classic Controller Complete Guide
  • Maintenance of M&C SP2006-H/DIL Sampling Probe
  • Pro face connection to Mitsubishi DIASYS Netmation
  • OMRON SYSMAC C-series/CVM1/CV series analog I/O units
  • LTI ServoOne Replacement and Troubleshooting
  • OMRON C-series AD/DA module configuration
  • Siemens 840C 611D Module Replacement Guide
  • Diagnosis and maintenance of ABB ACS550 frequency converter fault codes
  • OMRON NX1P2 Hardware Debugging Guide
  • Fuji FRENIC Mini inverter troubleshooting
  • Braided Forissier Braided Copper Strip Selection Guide
  • Mecc Alte MC200 Controller Engineering Debugging and Troubleshooting
  • Schneider Square D 9036/9037/9038 Electromechanical Liquid Level Controller
  • Pilz PSS 4000 distributed safety control
  • Schneider TeSys GV5/GV6 Motor Circuit Breaker Operation and Protection Guide
  • Eaton Freedom NEMA Contactor Starter Complete Guide
  • OMRON D4SL-N/D4SL-NSK10-LK Safety Door Switch Comprehensive Guide
  • NI CompactRIO Embedded System
  • Emerson Ovation I/O Module Troubleshooting and Replacement Practical Guide
  • MITSUBISHI A-series PLC Troubleshooting Replacement
  • Automation Direct DL06 D0-06DD1 Replacement Guide
  • IFM CR2530 Intelligent Controller Guide
  • OMRON FH/FHV series visual sensor controller
  • Pilz PDP67 F4 code troubleshooting
  • Panasonic FP-X PLC Replacement and Troubleshooting
  • OMRON CK3W-AX Multi axis Control Selection
  • Debugging and maintenance of EPSON RC90/RC90-B controller
  • Nthytronic Group iRTUe I/O Expansion Module
  • Schneider ATV320 Inverter Installation and Debugging Guide
  • Eaton SPB Drawdown Switch Maintenance Guide
  • GFS EVO-SP dual fuel retrofit complete solution
  • OMRON CJ2 CPU Troubleshooting and Maintenance
  • Complete Guide to Lenze ECS Servo System
  • GE EX2100e Excitation System Complete Guide
  • OMRON G3PW Power Controller: Parameter Setting and Troubleshooting Guide
  • Key Points for Selection and Deployment of MITSUBISHI FX3GE PLC
  • Beckhoff EP23xx EtherCAT Box Selection Troubleshooting
  • MITSUBISHI MDS-B servo troubleshooting
  • TOYO valve pressure and temperature selection
  • SIEMENS SIMODRIVE 611 HR/HRS Replacement and Advanced Positioning Techniques
  • SIEMENS SINUMERIK 840C 611-D Startup and Troubleshooting Guide
  • FANUC Series 0i-F Maintenance and Troubleshooting
  • Troubleshooting Schneider Modicon TM3 Bus Expansion
  • Troubleshooting of R&S EPL1000
  • Baum ü llerb b maXX 5000 Safety Configuration and Troubleshooting Guide
  • Huichuan AM600 Motion Controller Malfunction and Replacement Guide
  • Allen Bradley Ultra3000 Servo Motor Replacement Guide
  • NEC NL8060BC26-17 LCD Module Maintenance and Replacement
  • ABB Pluto Safety PLC Maintenance and Troubleshooting
  • OMRON NE1A Safety Controller Troubleshooting and Replacement
  • Allen Bradley 2711P series PanelView Plus human-machine interface terminal
  • NI cFP-22xx on-site integration and troubleshooting
  • KEYENCE XG-8000 Line Scan Visual Debugging Guide
  • OMRON G9SX Security Unit Configuration and Troubleshooting
  • OMRON CPM1A Maintenance and Troubleshooting
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide