  • GE IC693MDL655 DC Positive/Negative Logic Input module
    ❤ Add to collection
  • GE IC693MDL655 DC Positive/Negative Logic Input module

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IC693MDL655 DC Positive/Negative Logic Input module

    • ¥12000.00
      ¥24520.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.600KG
    • Quantity:
    • (Inventory: 33)
Description

GE IC693MDL655 DC Positive/Negative Logic Input module


GE IC693MDL655 DC Positive/Negative Logic Input module

DESCRIPTION

The 24 volt DC Positive/Negative Logic Input module for the Series 90-30 Programmable Logic Controller provides 32 discrete  input points.  The inputs are arranged in four isolated groups of eight (A1 - A8, B1 - B8, C1 - C8, and D1 - D8); each group has its own common. The inputs are positive or negative logic inputs and will operate at levels up to 30V. Backplane isolation between the field side and logic side is provided by opto-couplers on the module.  Isolation is also provided between the four groups of inputs on the module, however each group of eight inputs is  referenced to the same user common connection.  There are no special fault or alarm diagnostics reported.  LED indicators (labeled A1 - A8, B1 - B8, C1 - C8, D1 - D8) at the top of the module provide the ON/OFF status of each input point.

Functionality and Features

Dual - Logic Input Signal Reception

The module can receive both DC positive and negative logic input signals. This flexibility allows it to interface with a wide range of sensors and other input devices that may use different logic - level conventions. For example, it can handle positive - logic signals from devices like push - buttons and proximity sensors, as well as negative - logic signals from other specialized sensors or legacy equipment. The input voltage ranges for both positive and negative logic are carefully defined to ensure accurate signal detection and processing.

Signal Conditioning and Filtering

Similar to other input modules, the IC693MDL655 incorporates signal - conditioning circuitry. This circuitry is responsible for filtering out electrical noise and interference that could affect the integrity of the input signals. By reducing noise, the module provides more reliable input data to the control system. It may also include amplification or attenuation functions to adjust the input - signal strength to an appropriate level for internal processing.

Input Signal Protection Mechanisms

To safeguard against electrical faults, the module is equipped with various protection mechanisms. It has over - voltage protection to prevent damage from voltage spikes or incorrect voltage levels. Over - current protection is also in place to limit the current flowing through the input channels in case of a short - circuit or other abnormal current - draw conditions. Additionally, reverse - polarity protection ensures that the module can withstand incorrect wiring without being damaged.

Input State Monitoring and Reporting

The module continuously monitors the state of each input signal. It can quickly detect changes in the logic state, whether from positive to negative or vice - versa. Once a change is detected, it reports this information to the connected control system in a timely manner. The reporting is usually done through a digital communication interface, allowing the control system to respond appropriately based on the input - signal changes.

Compatibility and Integration with Control Systems

The IC693MDL655 is designed to be easily integrated into GE's industrial - control - system architecture and other compatible systems. It has a standard communication interface that enables seamless data transfer between the module and the control system's central processing unit. This allows the input - signal data to be used in control - logic programs, decision - making processes, and other system - level operations.

Technical Specifications

Input - Signal Specifications

Positive - Logic Inputs: The module defines the voltage range for positive - logic input signals, such as 10 - 30V DC. The logic - high and logic - low thresholds are precisely specified, for example, a logic - high might be recognized at 18V and above, and a logic - low at 10V and below. The number of positive - logic input channels is also provided, which could be a specific number like 16 or 32.

Negative - Logic Inputs: For negative - logic inputs, the voltage range might be specified as - 30V to - 10V DC. The logic - high and logic - low thresholds are adjusted accordingly, with a logic - high recognized at - 10V and above (in the negative - voltage context), and a logic - low at - 30V and below. The number of negative - logic input channels is typically the same as or different from the positive - logic channels, depending on the module's design.

Input - Impedance: The input - impedance values for both positive and negative - logic input channels are important parameters that affect the loading on the input - signal sources.

Protection - Specifications

Over - Voltage Protection: The maximum - over - voltage the module can handle for both positive and negative - logic inputs is specified. The protection - mechanism details, such as the use of transient - voltage - suppressor components or other protective circuits, are provided.

Over - Current Protection: The maximum - allowable - current through each input channel is defined, along with the over - current - protection method, such as current - limiting resistors or self - resetting fuses.

Reverse - Polarity Protection: The module's ability to withstand reverse - polarity conditions for both positive and negative - logic inputs is described, along with the associated protection - circuitry, such as reverse - polarity - protection diodes.

Communication - Interface Specifications

The module uses a specific communication interface to interact with the control system. The supported communication protocol, such as the GE Genius Bus or other protocols, is specified. The data - transfer - rate capabilities, the number of supported - connections, and the physical - connection requirements (e.g., pin - configuration) are also provided.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide
  • SUMITOMO ELECTRIC AC1135U Small Parts Turning Application Guide
  • SUMITOMO ELECTRIC AC1030U Precision Machining Selection and Practice for Small Parts
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection
  • BENDER RCMA475LY Residual Current Monitoring
  • BENDER IRDH575 Insulation Monitoring
  • BENDER IRDH265 Insulation Monitoring and Debugging
  • Bender RCMA475LY residual current monitor debugging
  • Beckwith Electric M-3425A Generator Protection Relay Debugging Guide
  • Automated MEX816U Expander Troubleshooting Guide
  • ASEM HT2150 Industrial Tablet Selection and Troubleshooting
  • Troubleshooting and practical application of Advantest U3771/3772 microwave spectrum analyzer
  • Advantest R6144 Programmable DC Voltage/Current Source (Calibration Source) Calibration and Maintenance
  • Aerotech UNIDEX 100/U100i single axis motion controller
  • Aerotech Ndrive MP Ultra Compact PWM Digital Servo Driver
  • Aerotech Ndrive HPe 10/20/30 High Performance PWM Digital Servo Drive
  • Aerotech Ndrive HLe maintenance replacement
  • Aerotech Ndrive CP maintenance replacement
  • Aerotech Ndrive Linear Drive Selection
  • Aerotech NDrive HL linear drive maintenance replacement
  • Aerotech NDrive HP 10/20/30 Maintenance and Replacement
  • Aerotech NDrive CP10 Servo Drive Guide
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration