  • GE PQM-T20-C-A Power QualIty Meter
    ❤ Add to collection
  • GE PQM-T20-C-A Power QualIty Meter

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE PQM-T20-C-A Power QualIty Meter

    • ¥22500.00
      ¥24520.00
      ¥22500.00
      ¥22500.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.600KG
    • Quantity:
    • (Inventory: 33)
Description

GE PQM-T20-C-A Power QualIty Meter


GE PQM-T20-C-A Power QualIty Meter

DESCRIPTION

GE Multilin has set a new standard in metering technology with the introduction of the PQM II.  This meter, designed on the latest industry specifications, provides accurate and reliable three-phase power metering with an optional Ethernet and fiber communications module in a small and modern package. The PQM II  can be used for a variety of applications including metering of distribution feeders,transformers, generators and motors.

Key BeneFIts

 • Power quality metering with waveform capture and historical data logging 

 • Easy to program and use with keypad and large illuminated 40 character display 

 • Multiple communication ports for integration with DCS and SCADA systems• Supports DNP 3.0 and Modbus protocols 

 • Digital and analog I/Os for control and alarms 

 • Voltage disturbance recording capability for electrical sag and swell events.

Features

Monitoring and Metering

• Ia Ib Ic In 

 • Va Vb Vc Vab Vbc Vca 

 • V I unbalance 

 • True PF crest and K factor 

 • Hz W var VA 

 • Wh varh VAh W cost 

 • Demand: A W var VA 

 • Harmonic analysis through 63rd with THD and TIF 

 • Event recorder - 150 events 

 • Waveform capture 

 • Data logger -98,000 events 

 • Voltage Disturbance Recorder (VDR) -500 events

Technical specifications and parameters

Brand: GE (General Electric)

Model: PQM-T20-C-A

Measuring range: Wide coverage of various parameters of the power system, the specific range according to the actual application requirements.

Precision: High-precision measurement capability to ensure the accuracy and reliability of data.

Operating voltage: Adapt to a variety of voltage levels, the specific voltage range should be determined according to the product manual or consult the manufacturer.

Output Frequency: Provide output signals of different frequencies according to the measurement parameters and settings.

Communication interface: Provide a variety of communication interfaces, such as RS-232, RS-485, etc., which is convenient for connection and data transmission with the upper computer or data management system.

Functional features

Real-time monitoring: capable of real-time monitoring of various parameters of the power system, including voltage fluctuations, current harmonics, frequency changes, etc.

Data analysis: Built-in powerful data analysis function, capable of processing and analysing the monitoring data to provide power quality analysis report.

Alarm function: When the power system is abnormal or faulty, it can automatically trigger the alarm function to notify the user to take measures in time.

Programmable Settings: Support users to make programmable settings according to actual needs, such as setting measurement parameters and alarm thresholds.

Installation and maintenance: Easy to install and maintain design, convenient for users to carry out daily operation and maintenance work.

Application Fields

Industrial field: It can be used for power monitoring of production lines, factory facilities or important equipment to ensure the stability and quality of the power system.

Commercial buildings: can be used to monitor the power quality of the entire building or a specific area, to help managers optimise energy use and reduce energy costs.

Utilities: Widely used in power companies or public utilities to monitor parameters such as grid load, voltage fluctuations and power factor.

Renewable energy systems: can be used to monitor and optimise the quality of power generated by renewable energy systems such as solar and wind.

Medical facilities: In medical facilities, it can be used to monitor the power supply of medical equipment to ensure stable operation and safety of medical equipment.

Precautions

When using the GE PQM-T20-C-A power quality meter, ensure its compatibility and match with the power system.

Inspect and maintain the power quality meter regularly to ensure its normal operation and prolong its service life.

During installation and commissioning, the installation guide and operation manual provided by GE should be followed to ensure proper installation and configuration.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • SIEMENS SIMODRIVE 611 HR/HRS Replacement and Advanced Positioning Techniques
  • SIEMENS SINUMERIK 840C 611-D Startup and Troubleshooting Guide
  • FANUC Series 0i-F Maintenance and Troubleshooting
  • Troubleshooting Schneider Modicon TM3 Bus Expansion
  • Troubleshooting of R&S EPL1000
  • Baum ü llerb b maXX 5000 Safety Configuration and Troubleshooting Guide
  • Huichuan AM600 Motion Controller Malfunction and Replacement Guide
  • Allen Bradley Ultra3000 Servo Motor Replacement Guide
  • NEC NL8060BC26-17 LCD Module Maintenance and Replacement
  • ABB Pluto Safety PLC Maintenance and Troubleshooting
  • OMRON NE1A Safety Controller Troubleshooting and Replacement
  • Allen Bradley 2711P series PanelView Plus human-machine interface terminal
  • NI cFP-22xx on-site integration and troubleshooting
  • KEYENCE XG-8000 Line Scan Visual Debugging Guide
  • OMRON G9SX Security Unit Configuration and Troubleshooting
  • OMRON CPM1A Maintenance and Troubleshooting
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform