Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE PACSystems RX7i, RX3i and RSTi-EP  TCP/IP Ethernet  Communications
    ❤ Add to collection
  • GE PACSystems RX7i, RX3i and RSTi-EP TCP/IP Ethernet Communications

    GE PACSystems RX7i, RX3i and RSTi-EP  TCP/IP Ethernet  Communications

    • ¥36500.00
      ¥36528.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:4.900KG
    • Quantity:
    • (Inventory: 55)
Description

GE PACSystems RX7i, RX3i and RSTi-EP  TCP/IP Ethernet  Communications


GE PACSystems RX7i, RX3i and RSTi-EP  TCP/IP Ethernet  Communications

Ethernet Interfaces for PACSystems Controllers

A PACSystems Ethernet Interface enables a PACSystems controller to communicate with other PACSystems  equipment and with Series 90 and VersaMax controllers. The Ethernet Interface provides TCP/IP  communications with other PLCs, host computers running the Host Communications Toolkit or CIMPLICITY  software, and computers running the TCP/IP version of the programming software. These communications use  the proprietary SRTP and Ethernet Global Data (EGD)1 protocols over a four-layer TCP/IP (Internet) stack.  The Ethernet Interface has SRTP client/server capability. As a client, the Interface can initiate communications  with other PLCs that contain Ethernet Interfaces. This is done from the PLC ladder program using the  COMMREQ function. As a server, the Ethernet Interface responds to requests from devices such as PLC  programming software, a Host computer running an SRTP application, or another PLC acting as a client.

Rack-based and RX7i Embedded Interfaces - Features

▪ Full RX3i Controller programming and configuration services with inactivity timeout 

▪ Periodic data exchange using Ethernet Global Data (EGD) 

▪ EGD Commands to read and write PLC and EGD exchange memory over the network. 

▪ TCP/IP communication services using SRTP 

▪ SRTP Client (Channels) 

▪ Modbus TCP Server, supporting Modbus Conformance classes 0, 1, and 2. 

▪ Modbus TCP Client, supporting Modbus Conformance classes 0, 1, and Function Codes 15, 22, 23, and  24 for Conformance class 2.  

▪ Redundant IP Addressing capability.  

▪ Basic remote PLC monitoring from a web browser (RX7i CPU Ethernet interface only) 

▪ Comprehensive station management and diagnostic tools 

▪ Extended controller connectivity via IEEE 802.3 CSMA/CD 10Mbps and 100Mbps Ethernet LAN port  connectors. 

▪ Network switch that has Auto negotiate, Sense, Speed, and crossover detection. 

▪ Direct connection to BaseT (twisted pair) network switch, hub, or repeater without an external  transceiver. 

▪ Protocol is stored in flash memory in the Ethernet interface and is easily upgraded through the CPU  serial port. 

▪ Communications with remote PLCs and other nodes reachable through routers. The gateway IP  address must be configured. 

▪ Internet access via web pages served up to standard web browsers, for the Ethernet interface  embedded in the PACSystems RX7i CPU.

RX3i & RSTi-EP Embedded Ethernet Interface - Features

▪ Full RX3i controller programming and configuration services with inactivity timeout 

▪ TCP/IP communication services using SRTP.  

▪ SRTP Client (Channels) 

▪ Modbus TCP Server, supporting Modbus Conformance classes 0, 1, and 2. 

▪ Modbus TCP Client, supporting Modbus Conformance classes 0, 1, and Function Codes 15, 22, 23, and  24 for Conformance class 2.  

▪ Communications with remote PLCs and other nodes reachable through routers. The Gateway IP  address must be configured. 

▪ Comprehensive station management and diagnostic tools. For supported commands, refer to the  PACSystems TCP/IP Ethernet Communications Station Manager User Manual, GFK-2225J or later.

CPE302/CPE305/CPE310

▪ Extended controller connectivity via IEEE 802.3 CSMA/CD 10Mbps and 100Mbps Ethernet LAN port  connectors. 

▪ Network switch that has Auto negotiate, Sense, Speed, and crossover detection. 

▪ Direct connection to BaseT (twisted pair) network switch, hub, or repeater without an external  transceiver.

CPE330/CPE400/CPL410

• Two independent 10/100/1000 Ethernet LANs under the control of the embedded RX3i PLC. Port 1  attaches to LAN1 through a dedicated RJ45 connector. Port 2 attaches to LAN2 through a pair of  internally-switched RJ45 connectors. Space is provided to mark in the two corresponding IP  addresses. 

• The embedded Ethernet interface permits the CPU to support two LANs. 

• CPE400 has a third Ethernet port (located on the underside) which is under the control of Field Agent. 

• CPL410 also has a third Ethernet port (located on the underside) which is under the control of the  Linux OS.

RSTi-EP CPE100/CPE115

• Two independent 10/100 Ethernet LANs. Port 1 attaches to LAN1 through a dedicated RJ45  connector. Port 2 attaches to LAN2 through three internally-switched RJ45 connectors.  

• The embedded Ethernet interface permits the CPU to support two LANs.

Ethernet Interface Specifications

Connectors

- Two 10BaseT / 100BaseTX Ports: 8-pin female shielded RJ-45, autosensing 

- Station Manager (RS-232) Port: 9-pin female D-connector

Maximum number of  connections

48 SRTP Server connections. Includes: 

▪ A maximum of 16 Modbus/TCP Server connections 

▪ A maximum of 32 communication channels. (Each channel may be an  SRTP Client or a Modbus/TCP Client. Any given channel can be assigned to  only one protocol at a time.)

Embedded Ethernet Switch:Yes – Allows daisy chaining of Ethernet nodes.

Serial Port:Station Mgr Port: RS-232 DCE, 1200 - 115200 bps.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Yokogawa AIP830 Single Circuit Operation Keyboard
  • Yokogawa RAMC flowmeter selection and troubleshooting
  • YASKAWA GA500 frequency converter troubleshooting
  • TRACO TIS600 power supply
  • Sigmatek ETV-0851 Control Panel Troubleshooting
  • Allen Bradley Quest AN-X2-AB-DHRIO Remote I/O Adapter Integration and Troubleshooting
  • Meggitt RPS6U power supply
  • Kongsberg RCU500 Controller Integration and Fault Diagnosis Guide
  • KBAC series frequency converter installation and fault diagnosis guide
  • EXOR effectiveness View eV058 series HMI industrial panel
  • Emerson OCR3000 Controller Troubleshooting Guide
  • Emerson Ovation OCR1100 Controller Maintenance and Troubleshooting
  • Elmo G-TUB30 Driver Troubleshooting Guide
  • Troubleshooting and Optimization of Basler A400 Series Camera
  • Troubleshooting and Maintenance of Automated Logic I/O Expansion Module
  • Troubleshooting and Maintenance of Aerotech UNIDEX 100 Controller
  • ADVANEST R6144 calibration source troubleshooting
  • Troubleshooting and Calibration of ABB Millmate Tension Gauge
  • ABB NGC8206 natural gas chromatograph troubleshooting and maintenance
  • ABB AO2040-CU Ex Explosion proof Analyzer Troubleshooting
  • ABB PFEA113 Tension Controller Troubleshooting Guide
  • ABB PFEA111/112/122 Tension Controller Troubleshooting Guide
  • ABB LS4000 laser analyzer
  • ABB SPAU 341 C Voltage Regulator Troubleshooting Guide
  • Analysis and Fault Diagnosis of ABB V-Contact VSC Medium Voltage Contactor
  • ABB UNITOL 1020 Compact Digital Excitation Regulator AVR Replacement and Troubleshooting
  • ABB UNITROL 1000 excitation system replacement and troubleshooting
  • ABB SYNC HROTACT 5 synchronization module troubleshooting and replacement
  • ABB SYNC HROTACT 5 Synchronization Device Replacement and Troubleshooting Guide
  • ABB Symphony Plus Module Replacement and Upgrade Guide
  • ABB S900 I/O Hazardous Area Deployment and Maintenance
  • ABB System 800xA Operations and Troubleshooting
  • ABB PCS6000 Troubleshooting and Module Replacement Guide
  • ABB PCS 8000 pumped storage excitation
  • ABB Procontrol P13 Bus Coupling Upgrade Guide
  • ABB NextMove ESB-2 Fault Diagnosis and Configuration Practice
  • ABB MEGADRIVE-LCI Maintenance and Selection Practice
  • ABB MEGADRIVE LCI Transmission Vibration Suppression
  • ABB MEGADRIVE LCI Water Cooling Troubleshooting and Maintenance Guide
  • Practical Maintenance and Common Troubleshooting of ABB DCS880
  • ABB SDCS-IOB-3 Replacement and Troubleshooting
  • ALSTOM MAE99-04 Serial Interface Terminal Panel Maintenance and Troubleshooting
  • Installation and Maintenance of ALSTOM ALSPA MV3000 Handheld Operator
  • Maintenance and commissioning of ABB KPM KB2 paper breakage detector
  • Maintenance and troubleshooting of ABB SCC-K converter
  • ABB SCC Gas Preprocessing System Maintenance and Selection Guide
  • ABB NGC8209 gas chromatograph maintenance
  • Maintenance and troubleshooting of ABB DCS DC speed controller
  • ABB ASTAT Crane Controller Maintenance and Debugging Guide
  • ABB ACS800 TIM foil IGBT
  • ABB LS25 laser analyzer troubleshooting
  • ABB REM54 motor terminal troubleshooting
  • ABB REL670 distance protection and troubleshooting
  • ABB SUE3000 switching device troubleshooting
  • ABB REF630 feeder protection
  • ABB REF620 (Relion 620 series) feeder protection and measurement device
  • ABB E1B-A Circuit Breaker
  • ABB FCU400-IR temperature measurement system troubleshooting
  • ABB TZIDC-200 locator configuration and troubleshooting
  • ABB DHH805-A Handheld Operator Configuration and Activation Guide
  • ABB SACO 16D1 alarm device replacement and troubleshooting
  • ABB 5SHY3545L0016 IGCT module replacement guide
  • ABB S600 I/O Module Replacement and Troubleshooting Guide
  • ABB NextMove e100 motion controller troubleshooting guide
  • Rockwell PowerFlex 700 Inverter Replacement and Troubleshooting Guide
  • Allen Bradley 1762-OW16 Output Module
  • Allen Bradley IntelliVAC 1503VC Series E Control Module
  • Allen‑Bradley IntelliVAC ™ 1503VC contactor control module
  • Woodward SOGAV 250 solenoid valve drives gas intake valve for troubleshooting
  • Woodward easyYgen-3500XT-P1 obstacle removal
  • Woodward CPC-II electro-hydraulic current pressure converter
  • UniOP ePALM10 Handheld HMI
  • TMEIC TMdrive-30 frequency converter
  • TEWS TVME200 Carrier Board Configuration and Troubleshooting Guide
  • TDK Alpha 400 Power Troubleshooting Guide
  • STUCKE SYMAP relay
  • Deployment and troubleshooting of Softing CAN-AC2-PCI interface card
  • Installation, Maintenance, and Troubleshooting of Siemens C7-623/624
  • Foxboro Compact 200 Series 16 Slot Bottom Plate Deployment and Maintenance Guide
  • Foxboro 84F/84W Vortex Flow Meter Selection and Debugging Guide
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller
  • DATA PATTERNS DP-VME-5114 Dual PMC Carrier Board Integration and Troubleshooting
  • CMZ SVM1608 Intelligent Servo Driver
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide
  • SUMITOMO ELECTRIC AC1135U Small Parts Turning Application Guide
  • SUMITOMO ELECTRIC AC1030U Precision Machining Selection and Practice for Small Parts
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection
  • BENDER RCMA475LY Residual Current Monitoring
  • BENDER IRDH575 Insulation Monitoring
  • BENDER IRDH265 Insulation Monitoring and Debugging
  • Bender RCMA475LY residual current monitor debugging
  • Beckwith Electric M-3425A Generator Protection Relay Debugging Guide
  • Automated MEX816U Expander Troubleshooting Guide