Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE PACSystems RX7i, RX3i and RSTi-EP  TCP/IP Ethernet  Communications
    ❤ Add to collection
  • GE PACSystems RX7i, RX3i and RSTi-EP TCP/IP Ethernet Communications

    GE PACSystems RX7i, RX3i and RSTi-EP  TCP/IP Ethernet  Communications

    • ¥36500.00
      ¥36528.00
      ¥36500.00
      ¥36500.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:4.900KG
    • Quantity:
    • (Inventory: 55)
Description

GE PACSystems RX7i, RX3i and RSTi-EP  TCP/IP Ethernet  Communications


GE PACSystems RX7i, RX3i and RSTi-EP  TCP/IP Ethernet  Communications

Ethernet Interfaces for PACSystems Controllers

A PACSystems Ethernet Interface enables a PACSystems controller to communicate with other PACSystems  equipment and with Series 90 and VersaMax controllers. The Ethernet Interface provides TCP/IP  communications with other PLCs, host computers running the Host Communications Toolkit or CIMPLICITY  software, and computers running the TCP/IP version of the programming software. These communications use  the proprietary SRTP and Ethernet Global Data (EGD)1 protocols over a four-layer TCP/IP (Internet) stack.  The Ethernet Interface has SRTP client/server capability. As a client, the Interface can initiate communications  with other PLCs that contain Ethernet Interfaces. This is done from the PLC ladder program using the  COMMREQ function. As a server, the Ethernet Interface responds to requests from devices such as PLC  programming software, a Host computer running an SRTP application, or another PLC acting as a client.

Rack-based and RX7i Embedded Interfaces - Features

▪ Full RX3i Controller programming and configuration services with inactivity timeout 

▪ Periodic data exchange using Ethernet Global Data (EGD) 

▪ EGD Commands to read and write PLC and EGD exchange memory over the network. 

▪ TCP/IP communication services using SRTP 

▪ SRTP Client (Channels) 

▪ Modbus TCP Server, supporting Modbus Conformance classes 0, 1, and 2. 

▪ Modbus TCP Client, supporting Modbus Conformance classes 0, 1, and Function Codes 15, 22, 23, and  24 for Conformance class 2.  

▪ Redundant IP Addressing capability.  

▪ Basic remote PLC monitoring from a web browser (RX7i CPU Ethernet interface only) 

▪ Comprehensive station management and diagnostic tools 

▪ Extended controller connectivity via IEEE 802.3 CSMA/CD 10Mbps and 100Mbps Ethernet LAN port  connectors. 

▪ Network switch that has Auto negotiate, Sense, Speed, and crossover detection. 

▪ Direct connection to BaseT (twisted pair) network switch, hub, or repeater without an external  transceiver. 

▪ Protocol is stored in flash memory in the Ethernet interface and is easily upgraded through the CPU  serial port. 

▪ Communications with remote PLCs and other nodes reachable through routers. The gateway IP  address must be configured. 

▪ Internet access via web pages served up to standard web browsers, for the Ethernet interface  embedded in the PACSystems RX7i CPU.

RX3i & RSTi-EP Embedded Ethernet Interface - Features

▪ Full RX3i controller programming and configuration services with inactivity timeout 

▪ TCP/IP communication services using SRTP.  

▪ SRTP Client (Channels) 

▪ Modbus TCP Server, supporting Modbus Conformance classes 0, 1, and 2. 

▪ Modbus TCP Client, supporting Modbus Conformance classes 0, 1, and Function Codes 15, 22, 23, and  24 for Conformance class 2.  

▪ Communications with remote PLCs and other nodes reachable through routers. The Gateway IP  address must be configured. 

▪ Comprehensive station management and diagnostic tools. For supported commands, refer to the  PACSystems TCP/IP Ethernet Communications Station Manager User Manual, GFK-2225J or later.

CPE302/CPE305/CPE310

▪ Extended controller connectivity via IEEE 802.3 CSMA/CD 10Mbps and 100Mbps Ethernet LAN port  connectors. 

▪ Network switch that has Auto negotiate, Sense, Speed, and crossover detection. 

▪ Direct connection to BaseT (twisted pair) network switch, hub, or repeater without an external  transceiver.

CPE330/CPE400/CPL410

• Two independent 10/100/1000 Ethernet LANs under the control of the embedded RX3i PLC. Port 1  attaches to LAN1 through a dedicated RJ45 connector. Port 2 attaches to LAN2 through a pair of  internally-switched RJ45 connectors. Space is provided to mark in the two corresponding IP  addresses. 

• The embedded Ethernet interface permits the CPU to support two LANs. 

• CPE400 has a third Ethernet port (located on the underside) which is under the control of Field Agent. 

• CPL410 also has a third Ethernet port (located on the underside) which is under the control of the  Linux OS.

RSTi-EP CPE100/CPE115

• Two independent 10/100 Ethernet LANs. Port 1 attaches to LAN1 through a dedicated RJ45  connector. Port 2 attaches to LAN2 through three internally-switched RJ45 connectors.  

• The embedded Ethernet interface permits the CPU to support two LANs.

Ethernet Interface Specifications

Connectors

- Two 10BaseT / 100BaseTX Ports: 8-pin female shielded RJ-45, autosensing 

- Station Manager (RS-232) Port: 9-pin female D-connector

Maximum number of  connections

48 SRTP Server connections. Includes: 

▪ A maximum of 16 Modbus/TCP Server connections 

▪ A maximum of 32 communication channels. (Each channel may be an  SRTP Client or a Modbus/TCP Client. Any given channel can be assigned to  only one protocol at a time.)

Embedded Ethernet Switch:Yes – Allows daisy chaining of Ethernet nodes.

Serial Port:Station Mgr Port: RS-232 DCE, 1200 - 115200 bps.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • GE VMIVME-5532L VMEbus fiber optic repeater link
  • How to order GE VMIVME-5531L VMEbus fiber optic repeater link?
  • GE VMIVME-4514A 16 channel scanning analog I/O board
  • GE VMIVME-4150 isolated 12 channel 12 bit analog output board
  • GE VMIVME-3126 High Resolution Isolated Analog to Digital Converter Board
  • GE VMIVME-3100 16 channel 12 bit analog-to-digital converter board
  • What application areas is GE VMIVME-2540 24 Channel Intelligent Counter/Controller suitable for?
  • How to operate GE VMIVME-2511 programmable I/O board?
  • GE VMIVME-2510B 64 bit TTL digital I/O board
  • GE VMIVME-2128 128 bit high voltage digital output board
  • GE VMIMPC-5790 PMC Dual Channel Ultra160 SCSI Host Adapter
  • GE VMIVME-2170A 32-bit optically isolated digital output board
  • GE VMIPCI-5565 Ultrahigh Speed Fiber-Optic Reflective Memory with Interrupts
  • GE VMIACC-5595 2 Gb/s Reflective Memory Hub Component
  • GE VME-3125A Isolation Scan 12 Bit 32 Channel Analog to Digital Converter Board (6U)
  • GE VME-3122A High Performance 16 Bit Analog to Digital Converter (ADC)
  • GE VMIVME-2536 32 channel optically coupled digital I/O board
  • GE VMIVME-2528 128 bit TTL digital I/O TURBOModule ™
  • GE VMIVME-2232 32 32 channel relay output board
  • GE VMIVME-2210 64 channel latch or momentary relay board
  • GE VMIVME-1182 64 channel isolated digital input board
  • GE VMIVME-1128 128 bit high-voltage digital input board
  • GE VMIVME-111 64 bit High Voltage Digital Input Board
  • GE ACC-0603RC V7865 VME Rear Conversion Module
  • GE V7865 Intel ® Core ™ Duo Processor VME Single Board Computer
  • GE MVME5500 series VME single board computer
  • GE CPCI-7055RC PowerPC ® CompactPCI ® single board computer
  • GE VMIVME-3125 Analog Input Board
  • GE VMIVME-4105 8-Channel 12 Bit Multiplicative Digital to Analog Converter Board
  • GE VMIVME-5565 Ultra High Speed Fiber Reflective Memory (with Interrupt Function)
  • GE VMIVME-3122 High Performance 16 Bit Analog to Digital Converter (ADC)
  • GE VMIVME-2210 Relay Board
  • GE VMIVME-7648 Single Board Computer
  • How to install GE V7768/V7769 hardware?
  • GE VMIVME-7807/VME-7807RC Single Board Computer
  • GE VMIVME-7750 Single Board Computer
  • GE FANUC S2K series independent motion controller
  • How to maintain the GE Hydran 201Ti (Mark IV) transformer monitoring equipment?
  • How to order GE Hydran M2 (Mark III) transformer monitoring equipment?
  • How to install the GE Hydran M2 transformer gas monitoring system?
  • GE 10 "/12" QuickPanel View Compact Industrial grade Human Machine Interface (HMI) Computer
  • GE PACSystems RXi EP Box type Industrial Computer (IPC)
  • GE AT868 AquaTrans ™ Ultrasonic water flowmeter
  • How to determine if the GE MLJ synchronous check relay is in calibration mode?
  • GE MII series modular microcomputer relay
  • Bently 3500/15 AC/DC power module
  • Bently 990 vibration transmitter
  • Bently 2300 series vibration monitor
  • Bently 330400 and 330425 acceleration sensors
  • Bently 330500 Velomitor piezoelectric velocity sensor
  • Bently 3500/50M tachometer module
  • Bently 177230 seismic transmitter
  • Bently 3300 XL 8mm Proximity Sensor
  • GE Multilin 889 Generator Protection System
  • GE Multilin 515 Locking and Testing System
  • Bently 3500/20 Rack Interface Module
  • How to install and maintain the Bently Nevada 3500 monitoring system rack?
  • Bentley 60M100 Condition Monitoring System
  • Honeywell portable gas detection
  • Honeywell System Sensor L-Series Wall Mounted Sound and Light Alarm Equipment
  • Honeywell SPM Flex Chemical Box Gas Detector
  • Honeywell Midas ®- M gas monitoring system
  • Honeywell Midas-M Multi Gas Transmitter
  • Honeywell Satellite XT gas detection transmitter
  • Honeywell Unipoint DIN Rail Mounted Controller
  • Honeywell System 57 Control for Fire and Gas Detection
  • Honeywell HA72 Digital Gas Controllers
  • Honeywell HA71 Digital Gas Controller
  • Honeywell HA-20, HA-40, and HA-71 gas detection controllers
  • Honeywell Touchpoint Plus Gas Detection and Control System
  • Honeywell Analytics Touchpoint Pro Gas Detection Controller
  • Honeywell Raeguard 2 PID gas detector
  • Honeywell FSL100 series flame detector
  • DANFOSS MC024-010 and MC024-012 controllers
  • How to install ABB S500 series heavy-duty circuit breaker?
  • ABB PM665 3BDS005799R1 processor module
  • Honeywell SS2-AM Series Ultra-High Speed Digital Fire and Flame Detector (UV/IR)
  • Honeywell SS4 Series Multi-Spectrum ™ Electro-Optical Digital Fire & Flame Detector (UV/IR & UV)
  • What scenarios is Honeywell FS7 Multi Spectrum Fire and Flame Detector suitable for?
  • Honeywell FS10 Fire Detection Systems For Liquid Paint Spray and Electrostatic Powder Coating
  • Honeywell Model FS20X Multi-Spectrum Fire and Flame Detector UV/Dual IR/VIS
  • Honeywell Model F24X QuadBand ™ Triple IR Fire and Flame Detector (IR/IR/IR/Visible)
  • Honeywell Searchline Excel Cross Direct Infrared Open Circuit Gas Detector
  • Honeywell Searchline Excel Infrared Open Circuit Gas Detector
  • Honeywell Searchpoint Optima Plus Infrared Point Gas Detector
  • How to use Honeywell OELD intelligent junction box
  • How to install the Honeywell Series 3000 MkII and MkIII gas detectors?
  • Honeywell Sensepoint gas detector ordering method
  • How to maintain the Honeywell Sensepoint XCD RFD remote flammable gas detector?
  • Honeywell Sensepoint XCD gas detector
  • How to install the Honeywell Sensepoint XRL fixed gas detector?
  • Honeywell XNX Universal Transmitter Installation and Configuration Method
  • Honeywell Fixed Gas and Flame Detection Product Features
  • How to purchase Honeywell Sensepoint XCD?
  • Woodward 723PLUS Digital Controller
  • Woodward EPG electric speed regulator
  • Woodward 505 Turbine Digital Controller
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward ProTech GII overspeed protection device (triple module redundancy)
  • Woodward SPM-D10 series single circuit breaker synchronizer
  • Woodward SPM-D11 series load sharing synchronizer
  • Woodward 505E (Extraction/Inlet) Steam Turbine Digital Controller
  • Woodward TG-13 and TG-17 speed controllers
  • Woodward 723 Generator Controller
  • Woodward 505 Digital Control for Steam Turbines
  • Woodward MicroNet ™ Simplex Digital Control MicroNet ™ Plus Digital Control
  • Woodward MSLC-2 ™ Master Synchronizer and Load Control
  • Woodward GS10 Gas Metering System
  • Honeywell Spyder® BACnet® Programmable Controllers
  • Honeywell TR40, TR42 Room Sensors and Displays
  • Honeywell XNX Universal Transmitter
  • Honeywell H365 Series Addressable Heat Detectors
  • Honeywell Universal Marshalling Solution for Safety Systems
  • Honeywell D06F Pressure Reducing Valve
  • Honeywell CR-6A Six Relay Control Module Installation and Maintenance
  • Honeywell PlantCruise by Expert C300 Controller
  • Honeywell Expert Series-C I/O Specification
  • Honeywell WIN-PAK Access Control System Products and Solutions
  • Honeywell Sieger System 57 Modbus Interface Module Kit Operating Instructions
  • Honeywell SK Relay Installation and Maintenance
  • Aerotech EDU176 Ndrive HL series digital servo drive
  • Aerotech Ndrive HP 10/20/30 Series Digital Servo Drive
  • Aerotech Ndrive series digital servo drives
  • ZYGO ZMI 2000 System Displacement Measuring Interferometer Systems
  • GE Mark VIe Control System
  • GE Multilin MLJ synchronous inspection relay
  • Honeywell ControlEdge HC900 Controller
  • Honeywell UDC1200&UDC1700 Universal Digital Controller Series