Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • ABB GJR5252200R3101 07DC92 Configurable Digital I/O Module
    ❤ Add to collection
  • ABB GJR5252200R3101 07DC92 Configurable Digital I/O Module

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    07DC92 Configurable Digital I/O Module
    Manufacturers
    ABB

    Model(s)
    ABB Advant Controller 31, ABB Advant OCS

    Additional Information
    32 configurable inputs/outputs 24 V DC, 0.5 A
    Estimated Shipping Size
      Dimensions: 6.0" x 4.0" x 6.0"
      (15.2 cm x 10.2 cm x 15.2 cm)
      Weight: 1 lbs 1.0 oz (0.5kg )


    Tariff Code: 8538907080
    • ¥6952.00
      ¥94985.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:1.000KG
    • Quantity:
    • (Inventory: 2)
Description
07DC92 Configurable Digital I/O Module
Manufacturers
ABB

Model(s)
ABB Advant Controller 31, ABB Advant OCS

Additional Information
32 configurable inputs/outputs 24 V DC, 0.5 A
Estimated Shipping Size
  Dimensions: 6.0" x 4.0" x 6.0"
  (15.2 cm x 10.2 cm x 15.2 cm)
  Weight: 1 lbs 1.0 oz (0.5kg )


Tariff Code: 8538907080

ABB GJR5252200R3101 07DC92 Configurable Digital I/O Module

Basic information

Series: Part of ABB's Advant Controller 31 and Advant OCS series.

Place of origin: Switzerland and other countries.

Dimensions and weight: Approx. 15.2cm x 10.2cm x 15.2cm, weight approx. 0.5kg.

Performance characteristics

Number of channels and configuration: the module has 32 configurable digital input and output channels, the operating voltage is 24V DC, the current of each channel is 0.5A, according to the actual needs of the flexible configuration of the input or output channels to meet different industrial control application scenarios.

Interface type: Screw terminals are used as the interface type, which are firmly connected to ensure the stability of signal transmission, and are suitable for complex electrical environments in industrial sites, which can effectively prevent the signal from loosening due to vibration and other factors.

Signal Processing and Transmission: As a decentralised AC 31 input/output module, it can quickly and accurately process and transmit digital signals to achieve real-time monitoring and control of industrial equipment and production processes, and can be used in conjunction with PLCs and other controllers to form a complete industrial automation control system.

Application Fields

Industrial automation control system: In all kinds of industrial automation production lines, such as automobile manufacturing, machinery processing, food and beverage production, etc., it can be used to connect digital input devices such as buttons, switches, sensors, etc., as well as digital output devices such as relays, contactors, solenoid valves, etc., so as to realise the control functions of the production equipment such as starting, stopping, and monitoring of the operation status, etc., and to ensure the automation of the production line.

Process control system: In the chemical, petroleum, natural gas and other process industries, it can be used to monitor and control a variety of digital signals in the production process, such as equipment fault alarm signals, valve switching status signals, etc., and through the communication with the host computer system or PLC, it can achieve remote monitoring of the production process and automation control, and ensure the safe and stable operation of the production process.

Intelligent building and energy management system: In intelligent building, it can be used to connect the digital quantity equipment of lighting system, air conditioning system, security system, etc., to achieve the switching control of lighting, switching of air conditioning operation mode, alarm monitoring of security equipment, etc., so as to improve the level of building intelligence and the efficiency of energy use. At the same time, in the energy management system, it can be used to collect and control the digital signals of energy equipment, realise the monitoring and management of energy consumption, and provide data support and control means for energy saving and emission reduction.

OTHER INFORMATION

• Support for a number of new, popular communication protocols, e.g. Advant Fieldbus 100, Profibus DP, LONWorks and Allen-Bradley's DF1. These make your new controllers able to use ABB's new S800 I⁄O system and easily able to communicate, with other external controllers, with ABB's variable speed motor drives and with smart motor-control centers. 

• More backup redundancy available, e.g.: - Smarter solution to CPU redundancy, eliminating critical, common, components, - Full dual redundancy, covering, media and communication in interfaces, for S100 I/O and Advant Fieldbus 100. 

• A self-tuning, adaptive process controller (AC 450) that makes short work out of setting up control loops accurately and responsively, even in difficult applications. 

• Fuzzy logic control, a control method based on degrees of truths as opposedto conventional binary logic that only recognizes two states: true or false. A control strategy that is often able to untangle elegantly control problems that are difficult to solve in other ways. 

• Windows NT-based engineering tool, You save money; StepUp includes: 

• attractive prices on controller cabinets with all the hardware and software required. 

• further savings on future software upgrades by subscription to the ABB Software Advancement Program (described further on).

 

OTHER INFORMATION

• Read the safety precautions carefully. 

• Check the delivery for transportation damage. If damage is found, notify the  supplier as soon as possible. 

• Do not use the operator panel in an environment with high explosive hazards. 

• The supplier is not responsible for modified, altered or reconstructed  equipment. 

• Use only parts and accessories manufactured according to specifications of the  supplier. 

• Read the installation and operating instructions carefully before installing,  using or repairing the operator panel. 

• Never allow fluids, metal filings or wiring debris to enter any openings in the  operator panel. This may cause fire or electrical shock. 

• Only qualified personnel may operate the operator panel. 

• Storing the operator panel where the temperature is lower/higher than  recommended in this manual can cause the LCD display liquid to  congeal/become isotopic. 

• The LCD display liquid contains a powerful irritant. In case of skin contact,  wash immediately with plenty of water. In case of eye contact, hold the eye  open, flush with plenty of water and get medical attention.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications
  • Bonfiglioli 300 series reducer installation, maintenance, and troubleshooting guide
  • Selection and integration guide for Bonfiglioli R3 series planetary gearboxes in primary crushing equipment
  • Bonfiglioli C-series ATEX gearbox selection and explosion-proof application guide
  • Bonfiglioli Vectron EM-ENC-05 Full Function Expansion Module Integration Guide
  • Bonfiglioli Vectron EM-ENC-04 Multi functional Expansion Module Complete Configuration Guide
  • Bonfiglioli Vectron EM-ENC-03 Second Encoder Interface and System Bus Expansion Guide
  • Bonfiglioli Vectron EM-ENC-02 Expansion Module Integration and Encoder Interface Guide
  • Bonfiglioli Vectron CM-CAN CANopen Communication Configuration and DS402 Control Guide
  • Bonfiglioli Vectron EM-SYS System Bus Networking and Virtual Link Configuration Guide
  • Bonfiglioli Vectron CM-PDP Profibus DP Configuration and Debugging Guide
  • Bonfiglioli Vectron CM-232/485 Modbus Communication Configuration Guide
  • Bonfiglioli BMS series servo reduction motor selection and integration guide
  • Bonfiglioli ACTION 210/410 Inverter Debugging and Fault Diagnosis Complete Guide
  • Honeywell Enhanced Micro TDC 3000X System Redundancy Architecture and Maintenance Guide
  • Selection and Configuration of Bonfiglioli Active Series Inverter
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli HDP/HDO Series Heavy duty Gearboxes
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli 300/300M Series Gearboxes
  • Bonfiglioli 300M planetary gearbox selection and thermal verification guide
  • Bonfiglioli 3/H series heavy-duty gearbox selection and verification guide
  • Bonfiglioli KRG/KCG/KSD Hydraulic Coupling Selection and Integration Guide