Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • ABB GJV3075613R0202 Remote Binary Input Unit
    ❤ Add to collection
  • ABB GJV3075613R0202 Remote Binary Input Unit

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    Remote Binary Input Unit
    Manufacturers
    ABB

    Model(s)
    ABB Advant Controller 31, ABB Advant OCS

    Additional Information
    16 inputs, 1 ms delayed input
    Estimated Shipping Size
      Dimensions: 3.0" x 3.0" x 9.0"
      (7.6 cm x 7.6 cm x 22.9 cm)
      Weight: 1 lbs 0.0 oz (0.5kg )
    • ¥11383.00
      ¥127419.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.000KG
    • Quantity:
    • (Inventory: 2)
Description
Remote Binary Input Unit
Manufacturers
ABB

Model(s)
ABB Advant Controller 31, ABB Advant OCS

Additional Information
16 inputs, 1 ms delayed input
Estimated Shipping Size
  Dimensions: 3.0" x 3.0" x 9.0"
  (7.6 cm x 7.6 cm x 22.9 cm)
  Weight: 1 lbs 0.0 oz (0.5kg )

ABB GJV3075613R0202 Remote Binary Input Unit

Basic Information

Product Model Number: GJV3075613R0202.

Product name: Remote Binary Input Unit, this is a remote binary input unit from ABB for receiving and processing binary input signals in industrial automation systems.

Functional features

Signal reception and processing functions

Binary Input Signal Acquisition: Specifically designed to acquire binary (digital) input signals from external devices such as limit switches, proximity switches, push buttons and other devices. These signals usually indicate the state of the device (e.g., on/off, yes/no, on/off, etc.), and the unit is able to accurately receive and process these signals. For example, in an automated production line, it can receive proximity switch signals from product position detection to determine whether a product has reached a specified position.

Signal dithering and filtering (possible): In order to avoid incorrect signal acquisition due to signal dithering or interference, signal dithering and filtering functions may be available. In industrial environments, electrical interference, mechanical vibration and other factors may cause instantaneous changes in the input signal. With anti-dithering and filtering functions, it is possible to ensure that only stable, true signals are captured and processed. For example, for a limit switch signal that may close briefly due to mechanical vibration, the unit can filter out these unwanted signal changes.

Remote communication functions

Remote data transmission: As a remote unit, it has the function of transmitting the collected binary input signals to a remote control system. This is realised via various communication interfaces and protocols, such as Ethernet, Industrial Ethernet, serial communication, etc. This remote transmission function allows the operator and the control system to acquire and process these signals far away from the source, facilitating the monitoring and management of the system. For example, in a large factory, the unit can transmit status signals from equipment in the workshop to the control system located in the central control room.

Communication protocol support: A variety of communication protocols are supported to accommodate different industrial automation systems and devices. Common communication protocols include Modbus, Profibus, etc. These protocols ensure seamless communication with other devices (e.g., PLC, DCS, host computer, etc.). For example, in an automation system using the Modbus protocol, the remote binary input unit can easily exchange data with other devices in the system.

Diagnostic and Status Indication Functions

Fault Diagnostic Capability: It has certain fault diagnostic functions to detect its own hardware faults as well as abnormalities in the signal input channels. For example, it can detect whether the input signal is out of the normal range, whether there are faults such as open or short circuit. When the fault is detected, it will prompt the fault information to the user through corresponding ways (such as indicator flashing, sending fault code to the control system, etc.), which is convenient for the user to locate and solve the problem quickly.

Status Indicator Lamps: Equipped with status indicator lamps for intuitively displaying the working status and signal condition. For example, there are indicators to show whether the power supply is normal or not, whether there is a signal input for each input channel and so on. These indicators enable users to quickly judge the working status of the equipment on site, which is convenient for daily maintenance and management.

Physical characteristics and interfaces

Interface type and number: There are multiple binary input interfaces, the interface type may be screw terminal interface or plug-in interface. Screw terminal interface can be firmly connected to the wire, suitable for long-term stability of the connection; plug-in interface is easy to quickly replace the device or debugging. The number of interfaces depends on the design of the product and is generally sufficient for the connection of multiple binary input devices. In addition, there are communication interfaces for connection to remote control systems, which may include Ethernet, RS-232, RS-485, etc.

Physical Design: The design is usually compact and easy to install in limited spaces such as control cabinets or equipment racks. The casing is usually made of metal or high-strength engineering plastics, with good impact resistance and heat dissipation performance. In terms of installation, it may support rail mounting or screw-fixed installation, which is convenient for users to choose according to the actual installation environment and requirements. The internal circuit layout is reasonable, taking into account the electromagnetic compatibility and heat dissipation requirements to ensure long-term stable operation.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Advantest R6144 Programmable DC Voltage/Current Source (Calibration Source) Calibration and Maintenance
  • Aerotech UNIDEX 100/U100i single axis motion controller
  • Aerotech Ndrive MP Ultra Compact PWM Digital Servo Driver
  • Aerotech Ndrive HPe 10/20/30 High Performance PWM Digital Servo Drive
  • Aerotech Ndrive HLe maintenance replacement
  • Aerotech Ndrive CP maintenance replacement
  • Aerotech Ndrive Linear Drive Selection
  • Aerotech NDrive HL linear drive maintenance replacement
  • Aerotech NDrive HP 10/20/30 Maintenance and Replacement
  • Aerotech NDrive CP10 Servo Drive Guide
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications
  • Bonfiglioli 300 series reducer installation, maintenance, and troubleshooting guide
  • Selection and integration guide for Bonfiglioli R3 series planetary gearboxes in primary crushing equipment
  • Bonfiglioli C-series ATEX gearbox selection and explosion-proof application guide
  • Bonfiglioli Vectron EM-ENC-05 Full Function Expansion Module Integration Guide
  • Bonfiglioli Vectron EM-ENC-04 Multi functional Expansion Module Complete Configuration Guide
  • Bonfiglioli Vectron EM-ENC-03 Second Encoder Interface and System Bus Expansion Guide
  • Bonfiglioli Vectron EM-ENC-02 Expansion Module Integration and Encoder Interface Guide
  • Bonfiglioli Vectron CM-CAN CANopen Communication Configuration and DS402 Control Guide
  • Bonfiglioli Vectron EM-SYS System Bus Networking and Virtual Link Configuration Guide
  • Bonfiglioli Vectron CM-PDP Profibus DP Configuration and Debugging Guide