Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • IS200BPIHH1A | General Electric Interface Board
    ❤ Add to collection
  • IS200BPIHH1A | General Electric Interface Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    IS200BPIHH1A | General Electric Interface Board
    • ¥606.00
      ¥1159.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.500KG
    • Quantity:
    • (Inventory: 3)
Description
IS200BPIHH1A | General Electric Interface Board

IS200BPIHH1A | General Electric Interface Board

Product Description P/N: IS200EXIBG1AAA Description / Specifications Description The IS200EXIBG1AAA is a Printed Circuit Board (PCB) component engineered as part of the Mark VI series for gas/steam turbine management within GE's Speedtronic line. The Mark VI, the fifth commercially released system under the Speedtronic name, has been in production since the 1960s. Functionally, the IS200EXIBG1AAA serves as a crucial interface component between the exciter bridge of the Innovation Series (Medium Voltage SP) Drive and the EXIC board (Exciter Control Interface Card). Installed on the back side of the hinged panel where the EXIC board is mounted, it supports operation in both the 3300V and 6600V versions of the drive. 

Key functionalities provided by the board include current feedback, AC/DC voltage feedback, SCR gating, and metal oxide varistor fuse loss detection. Physically, the IS200EXIBG1AAA is equipped with sixteen heatsinks to dissipate excess heat efficiently. The board comprises capacitors made of polyester vinyl and ceramic material, along with eleven high-voltage electrolytic capacitors. Additionally, it features six transformers arranged in a line near the rear edge, two coil inductors, five resistor network arrays, ten plug connectors of varying size and type (male and female), and nine stab-on connectors. 

Diagnostic functionality is supported through forty-seven TP test points, allowing access to I/O signals, gate current amplifier signals, and power supply signals. Technical Specifications Part Number IS200EXIBG1AAA Description Exciter Bridge Interface Board Manufacturer GE General Electric Series Mark VI Product Type PCB component Application Gas/steam turbine management Features Interface functions between exciter bridge of Innovation Series Drive and EXIC board Mounting Location Back side of hinged panel where EXIC board is mounted Drive Compatibility Suitable for 3300V or 6600V version of the drive Functionality Provides current feedback, AC/DC voltage feedback, SCR gating, and metal oxide varistor fuse loss detection Heat Dissipation Sixteen heatsinks for dissipating excessive heat Components Capacitors (polyester vinyl and ceramic), high-voltage electrolytic capacitors, transformers, coil inductors, resistor network arrays, plug connectors, stab-on connectors Test Points Forty-seven TP test points for diagnostics and signal access Documentation GE publication GEI-100448 provides additional component information Information 

About IS200EXIBG1AAA The GE General Electric IS200EXIBG1AAA is a sophisticated Exciter Bridge Interface Board designed as part of the Mark VI series, playing a crucial role in the management of gas and steam turbines. This PCB component is specifically engineered to interface between the exciter bridge of the Innovation Series Drive and the EXIC board, ensuring seamless communication and efficient operation within turbine control systems. The IS200EXIBG1AAA is tailored for high-performance applications, providing essential functions that are critical to the effective management of turbine operations. 

It is suitable for use with both the 3300V and 6600V versions of the drive, highlighting its versatility and compatibility with a range of industrial setups. This compatibility ensures that the board can be integrated into various turbine control systems, offering robust performance and reliability. One of the key functionalities of the IS200EXIBG1AAA is to provide current feedback, AC/DC voltage feedback, SCR gating, and metal oxide varistor (MOV) fuse loss detection. These functionalities are vital for maintaining the stability and efficiency of turbine operations, ensuring accurate monitoring and control of the electrical parameters within the system. 

The board鈥檚 ability to provide these feedbacks and detections helps in maintaining optimal performance and preventing potential issues that could lead to system failures. The board is equipped with sixteen heatsinks designed for effective heat dissipation, preventing overheating and ensuring long-term reliability. This feature is particularly important in high-power applications where heat generation can be significant. The heatsinks help in maintaining the board鈥檚 operational temperature within safe limits, thereby enhancing its durability and performance. 

 In terms of components, the IS200EXIBG1AAA includes a variety of high-quality elements such as polyester vinyl and ceramic capacitors, high-voltage electrolytic capacitors, transformers, coil inductors, resistor network arrays, plug connectors, and stab-on connectors. These components are meticulously chosen to ensure reliable operation and long-term stability, making the board a dependable choice for critical applications. The board features forty-seven TP test points, providing extensive diagnostics and signal access capabilities. These test points allow for comprehensive monitoring and troubleshooting, facilitating maintenance and ensuring that any issues can be quickly identified and resolved. This feature enhances the overall reliability and ease of maintenance of the system. 

 The IS200EXIBG1AAA is designed to be mounted on the back side of a hinged panel where the EXIC board is also mounted, ensuring a compact and efficient layout. This mounting location is strategic, allowing for easy access and integration into existing systems without requiring significant modifications. For additional component information and detailed guidance, the IS200EXIBG1AAA is supported by the GE publication GEI-100448. This documentation provides essential details that help users understand the full capabilities and specifications of the board, ensuring proper installation and operation. 

 In summary, the GE General Electric IS200EXIBG1AAA Exciter Bridge Interface Board is a high-performance, reliable PCB component designed for the Mark VI series. With its versatile drive compatibility, robust heat dissipation, extensive diagnostic capabilities, and essential feedback functions, it is an indispensable part of gas and steam turbine management systems. The board's high-quality components and comprehensive documentation further ensure its effectiveness and reliability in demanding industrial applications. Manufacturer information General Electric (GE) is a multinational conglomerate founded in 1892, based in the United States. It operates in various industries, including aviation, healthcare, renewable energy, and power. 

GE is known for its innovations in technology, manufacturing, and infrastructure solutions. IQElectro is not an authorized distributor. QElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply.IQElectro sells SURPLUS onlyand DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications
  • Bonfiglioli 300 series reducer installation, maintenance, and troubleshooting guide
  • Selection and integration guide for Bonfiglioli R3 series planetary gearboxes in primary crushing equipment
  • Bonfiglioli C-series ATEX gearbox selection and explosion-proof application guide
  • Bonfiglioli Vectron EM-ENC-05 Full Function Expansion Module Integration Guide
  • Bonfiglioli Vectron EM-ENC-04 Multi functional Expansion Module Complete Configuration Guide
  • Bonfiglioli Vectron EM-ENC-03 Second Encoder Interface and System Bus Expansion Guide
  • Bonfiglioli Vectron EM-ENC-02 Expansion Module Integration and Encoder Interface Guide
  • Bonfiglioli Vectron CM-CAN CANopen Communication Configuration and DS402 Control Guide
  • Bonfiglioli Vectron EM-SYS System Bus Networking and Virtual Link Configuration Guide
  • Bonfiglioli Vectron CM-PDP Profibus DP Configuration and Debugging Guide
  • Bonfiglioli Vectron CM-232/485 Modbus Communication Configuration Guide
  • Bonfiglioli BMS series servo reduction motor selection and integration guide
  • Bonfiglioli ACTION 210/410 Inverter Debugging and Fault Diagnosis Complete Guide
  • Honeywell Enhanced Micro TDC 3000X System Redundancy Architecture and Maintenance Guide
  • Selection and Configuration of Bonfiglioli Active Series Inverter
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli HDP/HDO Series Heavy duty Gearboxes
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli 300/300M Series Gearboxes
  • Bonfiglioli 300M planetary gearbox selection and thermal verification guide
  • Bonfiglioli 3/H series heavy-duty gearbox selection and verification guide
  • Bonfiglioli KRG/KCG/KSD Hydraulic Coupling Selection and Integration Guide