GE IS200EDEXG1BExcitation Bridge and Protection Board
GE IS200EDEXG1BExcitation Bridge and Protection Board
Part Number IS200EDEXG1B Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series EX 2100e Function Module Availability In StockIS200EDEXG1B is an exciter De-Excitation Control Board designed and developed by GE. The EDEX is the de-excitation module's main board. When an emergency shutdown occurs and the field breaker or contactors open, this module removes stored energy from the generator field. To ensure operation in the event of a power outage, EDEX includes SCR firing, conduction sense feedback, and voltage retention.
On the EXTB board, EMIO initiates de-excitation. The EXTB board activates the 41dc contactor (MDA/MDB) or breaker, then transfers de-excitation signals from the auxiliary contacts to the EDEX's SCR firing circuits. EDEX boards are classified into two types. Group 1 is for SCR de-excitation, while Group 2 is for diode de-excitation. IS200EDEXG1B Functional Description Two firing commands are received through the EXTB and activate the firing circuit with redundant control. When the circuit is activated, it generates a high frequency square wave that is connected to the SCR gate and causes conduction. If this circuit fails or is delayed, the gate is activated by a self-firing circuit. This circuit consists of a break-over diode network connected to the SCR gate and controlled by the SCR anode voltage. Voltage Hold Up Circuit In the event of a total power failure, EDEX retains voltage on the positive and negative 24 V dc lines so that it can fire the SCR. The voltage hold up circuitry also provides voltage for wetting the external de- excitation contacts.
This ensures that the firing command is available for de-excitation in the event of a power outage. Conduction Sensors EDEX uses Hall Effect sensors to detect current in the field circuit. A mechanical ring couples magnetic flux to the sensors on the board's top edge. Separate circuits detect bi-polar current flow in sensor circuits 1 and 2. The current sense signals M1 and M2 are sent to EXTB and then to control. The mechanical ring is configured to detect unidirectional current flow in diode de-excitation applications. The status of both current sense circuits is indicated by two red LEDs. When current flow is detected, the indicators illuminate. SCR Firing Voltage The voltage and type of SCR used determine the SCR anode firing voltage. Wire jumpers are used to set the Break Over Diodes (BODs) and current limiting resistors. M1, M2, and the Break Over Diodes are wired together and connected to the gate of the SCR via the DEPL connector.
The EDEX will be destroyed if the break-over voltage of a break-over diode is exceeded and the BOD is not connected to the gate of the SCR. Check that the firing control circuit will fire the SCR before attempting to fire it by exceeding the break-over voltage of the BOD. IS200EDEXG1B Replacement Procedures Verify that the panel in which the board is located has been de-energized. Open the auxiliary cabinet door and check any electrical circuits for power before touching them. Disconnect all cables from the EDEX board with care as follows: Ensure that all cables are labeled with the correct connector name (as indicated on the board) to facilitate reconnection. Remove all cables from the board and remove the stab on wire jumper from connector E1A, leaving the other wire jumpers in place. Remove the conduction ring (flux concentrator) that sits on top of the Hall Effect sensors.
Remove the EDEX board by opening the PEM Snap Top fasteners that hold it to the intermediate mounting panel. Arrange the wire jumpers on the replacement EDEX board in the same order as on the old board, and double-check that jumpers JP1 and JP6 are in the same position. Place the replacement EDEX board in the same location on the mounting panel as the one that was removed, and secure it with the Snap Top fasteners. Install a new conduction ring. Reconnect all cables to the EDEX board as labeled, as well as the wire jumper to E1A, and double-check that cables are properly seated on both ends. Close the door to the auxiliary cabinet.
Technical specifications and performance
Voltage & Current: Specific voltage and current specifications may vary depending on application scenarios and customised requirements, but usually have multiple voltage and frequency adaptations to suit the power standards of different regions.
Durability and Safety: High-quality power interface boards are usually made of durable materials and equipped with safety devices such as fuses and circuit breakers to ensure long term reliability and stability while protecting the equipment and users.
Communication features: Some power interface boards may have communication interfaces that allow the device to communicate with a computer or other control system for remote monitoring and control.
Indicator Lights and Displays: Some power interface boards may be equipped with indicator lights for displaying information such as power status, connection status, etc., to facilitate troubleshooting and status monitoring by users.
Our Main Brands
· - ABB Advant-800xA,Advant OCS,Bailey Infi 90 and Net 90,H&B Freelance 2000,DSQC Robots,IGCT / IGBT
· - GE General Electric Field Control, Genius I/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax
· - Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,
· - Bently Nevada 3300 System, 3500 System
· - Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)
· - Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC
· - Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider
email:1583694102@qq.com
wang@kongjiangauto.com