Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS200ISBBG1A Insync Bus Bypass Card
    ❤ Add to collection
  • GE IS200ISBBG1A Insync Bus Bypass Card

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS200ISBBG1A Insync Bus Bypass Card

    • ¥30287.58
      ¥30254.02
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.820KG
    • Quantity:
    • (Inventory: 35)
Description

GE IS200ISBBG1A Insync Bus Bypass Card


GE IS200ISBBG1A Insync Bus Bypass Card

Part Number IS200ISBBG1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS200ISBBG1A is an Insync bus bypass card developed by GE. It is a part of EX2100 excitation system. The module incorporates a JP1 Interlock Bypass feature, which provides enhanced flexibility and control over the interlock functionality. 

The interlock bypass allows users to temporarily override the interlock system, enabling specific operations or functions to proceed even when certain interlock conditions are present. IS200ISBBG1A FEATURES Compact Size and DIN Rail Mounting: Designed to be compact, allowing for easy installation and integration into control systems. It is typically mounted on DIN rails, which are standard mounting rails used in industrial applications. The module's size and form factor make it suitable for space-constrained environments, providing flexibility in installation. 

Secure Mounting: Securely mounted on the DIN rail using screws. The DIN rail has four factory-drilled holes that align with corresponding holes on the module. The conductive material surrounding these holes ensures proper grounding and electrical connectivity. The holes are conveniently labeled as E1, E2, E3, and E4, aiding in the identification and connection of external components or other boards. Connector Options: Equipped with four connectors to facilitate connections with off-board components or other modules. These connectors include three plug connectors labeled as P1, P2, and P3, and a terminal strip labeled as P4. 

The specific functions of these connectors are identified as follows: P1 - Full Duplex, P2 - XMIT Data Out, P3 - RCV Data In, and P4 - 24 VDC Input. The connectors provide convenient interfaces for data exchange and power supply connections. Terminal Strip and Screw Connections: In addition to the plug connectors, the module features a terminal strip (P4) with two screw connections. This terminal strip offers a flexible and reliable means of connecting external wires or cables. It allows for secure and easily accessible connections, enhancing the overall functionality and versatility of the module. Jumper Position Indication: It includes a jumper whose position and corresponding outcome are clearly indicated on the board's surface. 

This visual indication assists in identifying the current configuration or setting of the jumper. The jumper's position may have an impact on the module's functionality or behavior, and the clear labeling ensures accurate setup and operation. LED Indicators: Features two LEDs, yellow and green, which serve as status indicators. The yellow LED represents XMIT data, providing visual feedback on the transmission of data. The green LED indicates the active state of the interlock, signaling whether the interlock system is engaged or not. These LED indicators provide quick and intuitive visual cues for monitoring the module's status. Integrated Voltage Comparator: The module incorporates an integrated circuit that includes a voltage comparator with a response time of 200ns. 

This voltage comparator plays a critical role in comparing voltages and generating output signals based on predefined thresholds. Its fast response time ensures efficient and accurate voltage comparisons, contributing to the overall performance and reliability of the module. CONTROL POWER SUPPLIES The exciter shares the HMI on turbine generator sets that include Mark VI turbine controls. The HMI is Windows NT-based, with CIMPLICITY operator display software and data highway communication drivers. From the HMI, the operator can initiate commands and view real-time data and alarms on the CIMPLICITY graphic displays. An HMI can be set up as a server or a viewer, and it can include tools and utility programs. 

The exciter is linked to the HMI or HMI/Data Server via the Unit Data Highway (UDH). The network is 10BaseT Ethernet, and uses separately powered network switches. Fiber-optic cables can be used for longer runs. DIN-RAIL-MOUNTED This model is exclusively suitable for DIN-rail-mounted setups. Power supply input for the model operates at 24 VDC. Functionality as an InSync Bus Bypass Card. Within the Mark VI system, it serves as an InSync Bus Bypass Card. The top edge of the board is marked with the board number and code 6BA01. The code 6DA01 is positioned along the bottom edge of the board. BOARD DESIGN AND MOUNTING The board features multiple factory-drilled locations, with four holes (E1, E2, E3, E4) surrounded by conductive material for DIN rail mounting. Two side-by-side relays are located left of the center of the board. The presence of rectifier coils, LED indicators (green and yellow), and a jumper switch are notable. COMPONENTS AND CONNECTIVITY A voltage comparator integrated circuit is present on the board. Connectors include three plugs marked P1 through P3, labeled Full Duplex, Xmit Data Out, and Rcv Data In. A short terminal strip with screw connections is labeled 24 VDC Input. COMPARISON BETWEEN ISBB GROUPS Due to the lack of documentation from General Electric, any major differences between ISBB groups are unknown. 

Visual inspection reveals no apparent differences between the two models. Features such as relays, potentiometers, and LED indicators are common to both models. LED INDICATORS AND DATA STATUS The model incorporates two LEDs: Interlock Active (green) and XMIT Data (yellow). These LEDs signify data and activity status. Whether the LEDs remain solid or flash to indicate faults is uncertain. DATA OUTPUT INDICATION The XMIT Data LED assists in indicating data transmission or reception. A labeled plug for XMIT Data out facilitates data outputs. 

 CONNECTORS P1-Full Duplex: Plug connector for full-duplex communication. P2-XMIT Data Out: Plug connector for transmitting data. P3-RCV Data In: Plug connector for receiving data. P4-24 VDC Input: Terminal strip with two screw connections for a 24 VDC input. MOUNTING Typically designed to be mounted on DIN rails. The board can be mounted using screws to four of its six factory-made drill holes. The holes used for mounting are labeled E1, E2, E3, and E4 and are ringed with a conductive material.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Advantest R6144 Programmable DC Voltage/Current Source (Calibration Source) Calibration and Maintenance
  • Aerotech UNIDEX 100/U100i single axis motion controller
  • Aerotech Ndrive MP Ultra Compact PWM Digital Servo Driver
  • Aerotech Ndrive HPe 10/20/30 High Performance PWM Digital Servo Drive
  • Aerotech Ndrive HLe maintenance replacement
  • Aerotech Ndrive CP maintenance replacement
  • Aerotech Ndrive Linear Drive Selection
  • Aerotech NDrive HL linear drive maintenance replacement
  • Aerotech NDrive HP 10/20/30 Maintenance and Replacement
  • Aerotech NDrive CP10 Servo Drive Guide
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications
  • Bonfiglioli 300 series reducer installation, maintenance, and troubleshooting guide
  • Selection and integration guide for Bonfiglioli R3 series planetary gearboxes in primary crushing equipment
  • Bonfiglioli C-series ATEX gearbox selection and explosion-proof application guide
  • Bonfiglioli Vectron EM-ENC-05 Full Function Expansion Module Integration Guide
  • Bonfiglioli Vectron EM-ENC-04 Multi functional Expansion Module Complete Configuration Guide
  • Bonfiglioli Vectron EM-ENC-03 Second Encoder Interface and System Bus Expansion Guide
  • Bonfiglioli Vectron EM-ENC-02 Expansion Module Integration and Encoder Interface Guide
  • Bonfiglioli Vectron CM-CAN CANopen Communication Configuration and DS402 Control Guide
  • Bonfiglioli Vectron EM-SYS System Bus Networking and Virtual Link Configuration Guide
  • Bonfiglioli Vectron CM-PDP Profibus DP Configuration and Debugging Guide