  • GE IS200ISBBG1A Insync Bus Bypass Card
    ❤ Add to collection
  • GE IS200ISBBG1A Insync Bus Bypass Card

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS200ISBBG1A Insync Bus Bypass Card

    • ¥30287.58
      ¥30254.02
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.820KG
    • Quantity:
    • (Inventory: 35)
Description

GE IS200ISBBG1A Insync Bus Bypass Card


GE IS200ISBBG1A Insync Bus Bypass Card

Part Number IS200ISBBG1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS200ISBBG1A is an Insync bus bypass card developed by GE. It is a part of EX2100 excitation system. The module incorporates a JP1 Interlock Bypass feature, which provides enhanced flexibility and control over the interlock functionality. 

The interlock bypass allows users to temporarily override the interlock system, enabling specific operations or functions to proceed even when certain interlock conditions are present. IS200ISBBG1A FEATURES Compact Size and DIN Rail Mounting: Designed to be compact, allowing for easy installation and integration into control systems. It is typically mounted on DIN rails, which are standard mounting rails used in industrial applications. The module's size and form factor make it suitable for space-constrained environments, providing flexibility in installation. 

Secure Mounting: Securely mounted on the DIN rail using screws. The DIN rail has four factory-drilled holes that align with corresponding holes on the module. The conductive material surrounding these holes ensures proper grounding and electrical connectivity. The holes are conveniently labeled as E1, E2, E3, and E4, aiding in the identification and connection of external components or other boards. Connector Options: Equipped with four connectors to facilitate connections with off-board components or other modules. These connectors include three plug connectors labeled as P1, P2, and P3, and a terminal strip labeled as P4. 

The specific functions of these connectors are identified as follows: P1 - Full Duplex, P2 - XMIT Data Out, P3 - RCV Data In, and P4 - 24 VDC Input. The connectors provide convenient interfaces for data exchange and power supply connections. Terminal Strip and Screw Connections: In addition to the plug connectors, the module features a terminal strip (P4) with two screw connections. This terminal strip offers a flexible and reliable means of connecting external wires or cables. It allows for secure and easily accessible connections, enhancing the overall functionality and versatility of the module. Jumper Position Indication: It includes a jumper whose position and corresponding outcome are clearly indicated on the board's surface. 

This visual indication assists in identifying the current configuration or setting of the jumper. The jumper's position may have an impact on the module's functionality or behavior, and the clear labeling ensures accurate setup and operation. LED Indicators: Features two LEDs, yellow and green, which serve as status indicators. The yellow LED represents XMIT data, providing visual feedback on the transmission of data. The green LED indicates the active state of the interlock, signaling whether the interlock system is engaged or not. These LED indicators provide quick and intuitive visual cues for monitoring the module's status. Integrated Voltage Comparator: The module incorporates an integrated circuit that includes a voltage comparator with a response time of 200ns. 

This voltage comparator plays a critical role in comparing voltages and generating output signals based on predefined thresholds. Its fast response time ensures efficient and accurate voltage comparisons, contributing to the overall performance and reliability of the module. CONTROL POWER SUPPLIES The exciter shares the HMI on turbine generator sets that include Mark VI turbine controls. The HMI is Windows NT-based, with CIMPLICITY operator display software and data highway communication drivers. From the HMI, the operator can initiate commands and view real-time data and alarms on the CIMPLICITY graphic displays. An HMI can be set up as a server or a viewer, and it can include tools and utility programs. 

The exciter is linked to the HMI or HMI/Data Server via the Unit Data Highway (UDH). The network is 10BaseT Ethernet, and uses separately powered network switches. Fiber-optic cables can be used for longer runs. DIN-RAIL-MOUNTED This model is exclusively suitable for DIN-rail-mounted setups. Power supply input for the model operates at 24 VDC. Functionality as an InSync Bus Bypass Card. Within the Mark VI system, it serves as an InSync Bus Bypass Card. The top edge of the board is marked with the board number and code 6BA01. The code 6DA01 is positioned along the bottom edge of the board. BOARD DESIGN AND MOUNTING The board features multiple factory-drilled locations, with four holes (E1, E2, E3, E4) surrounded by conductive material for DIN rail mounting. Two side-by-side relays are located left of the center of the board. The presence of rectifier coils, LED indicators (green and yellow), and a jumper switch are notable. COMPONENTS AND CONNECTIVITY A voltage comparator integrated circuit is present on the board. Connectors include three plugs marked P1 through P3, labeled Full Duplex, Xmit Data Out, and Rcv Data In. A short terminal strip with screw connections is labeled 24 VDC Input. COMPARISON BETWEEN ISBB GROUPS Due to the lack of documentation from General Electric, any major differences between ISBB groups are unknown. 

Visual inspection reveals no apparent differences between the two models. Features such as relays, potentiometers, and LED indicators are common to both models. LED INDICATORS AND DATA STATUS The model incorporates two LEDs: Interlock Active (green) and XMIT Data (yellow). These LEDs signify data and activity status. Whether the LEDs remain solid or flash to indicate faults is uncertain. DATA OUTPUT INDICATION The XMIT Data LED assists in indicating data transmission or reception. A labeled plug for XMIT Data out facilitates data outputs. 

 CONNECTORS P1-Full Duplex: Plug connector for full-duplex communication. P2-XMIT Data Out: Plug connector for transmitting data. P3-RCV Data In: Plug connector for receiving data. P4-24 VDC Input: Terminal strip with two screw connections for a 24 VDC input. MOUNTING Typically designed to be mounted on DIN rails. The board can be mounted using screws to four of its six factory-made drill holes. The holes used for mounting are labeled E1, E2, E3, and E4 and are ringed with a conductive material.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ADLINK NuPRO-E320 motherboard deployment and tuning guide
  • ADLINK NuPRO-800 Dual PIII Industrial SBC Maintenance and Upgrade Guide
  • ADLINK NuPRO-598 SBC Maintenance Practical Guide
  • ADLINK MXC-6300 Fanless Embedded Industrial Control Computer Deployment Guide
  • ADLINK Express-BASE7 Carrier Board Quick Deployment and Debugging Guide
  • ADLINK DLAP-211 Edge AI Platform Selection and Deployment Guide
  • ADLINK 7230 Series Isolation DIO Card Selection and Engineering Application Guide
  • ADLINK cPCI-6965 SBC Embedded Installation and BIOS Tuning Guide
  • ADLINK 7200 Series High Speed DIO Card Practical Guide
  • ADLINK DLAP Series Edge AI Acceleration Platform Selection and Deployment Practical Guide
  • DEIF TCM-2 thyristor control module: Wind power cut in control engineering guide
  • DEIF MVR-200 Medium Voltage Relay: Installation and Wiring Engineering Guide
  • DEIF MDR-2 Differential Relay: Engineering Guide for Generator Differential Protection
  • DEIF Delomatic 3 AOM: Engineering Guide for Analog Output Modules
  • DEIF AGI 400 Graphic Interface: Ship and Industrial HMI Solution
  • DEIF BRW-1 Marine Instruments: Installation and Calibration Guide for Offshore Bridge Indicators
  • DEIF AGC 200 Controller: Quick Deployment and Configuration Guide for Generator Sets
  • DEIF AGC-2 Controller: The Ultimate Guide to Automatic Control and Protection of Generator Sets
  • ABB SPA-ZC400 Gateway: REM54x Access to IEC 61850 Ultimate Engineering Guide
  • ABB REM 543/545 Terminal
  • Modular Architecture Analysis of DEIF PPU 300 Ship Generator Controller
  • DEIF DM-4 Marine&Offshore Ship Power Management System
  • Detailed Explanation of DEIF Delomatic Generator Control System Architecture
  • DEIF AGC-4 Mk II Generator Controller Depth Configuration Guide
  • DEIF AGC-4 Generator Controller Configuration and Debugging Guide
  • DEIF PPM Power Management System Operation and Troubleshooting
  • Installation and wiring of DEIF Multi line 2
  • Practical configuration and maintenance of Beckwith M-6280 capacitor bank controller
  • Beckwith M-3311 Transformer Protection Relay Setting and Engineering Application
  • Beckwith M-3311A Transformer Protection Relay Configuration and Optimization Guide
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit
  • Installation and I/O configuration of DEIF PPM-3 power management module
  • Beckwith M-3520 Interconnection Protection Relay
  • Beckwith M-3430 Generator Protection Relay
  • Beckwith M-2293B adapter panel replacement GE regulator guide
  • Selection and Networking of Beckwith M-2001C Digital Voltage Regulating Controller
  • Beckwith M-2001B Digital Voltage Regulating Controller
  • Beckwith M-0388/M-0389 Synchronous Inspection Relay Application Guide
  • Beckwith M-0193B Synchronizer Debugging and System Integration Guide
  • Beckwith M-0115A Parallel Balance Module Debugging Guide
  • Beckwith M-0067E On Load Voltage Regulating Controller Selection and Debugging Guide
  • Debugging and Fault Handling of Beckwith M-4272 Digital Busbar Conversion System
  • Beckwith M-3311A Transformer Protection Relay Debugging Guide
  • Beckwith M-3425A Generator Protection Relay Debugging Guide
  • Setting and troubleshooting of Basler BE1-27/59 voltage relay
  • Debugging and troubleshooting of Basler AVC63-12/AVC125-10 voltage regulator
  • Basler L301kc Line Array Camera Technology and Troubleshooting
  • Selection and Debugging of Basler CBS 212A Current Boosting System
  • Selection and commissioning of Basler BE3-25 synchronous inspection relay
  • Basler BE1-32R/32O/U Direction Power Relay Setting and Testing Guide
  • Basler PRS 250 Synchronous Relay Maintenance and Replacement Guide
  • Basler piA2400-17gc Industrial Camera Replacement and Optimization Guide
  • Basler BE1-11g Generator Protection System
  • Basler VR63-4C/UL Voltage Regulator
  • Basler BE1-DFPR feeder protection relay
  • Basler CBS 310/320 Current Boosting System
  • Basler UFOV 250A/260A protection module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F Regulator
  • Basler DECS-400 excitation system
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection
  • Basler SSR Static Voltage Regulator: A Complete Guide to Debugging and Troubleshooting
  • Basler SR4A/SR8A Voltage Regulator: Detailed Debugging and Troubleshooting Explanation
  • Basler BE2000E Voltage Regulator: Replacement and Application Details
  • Basler DECS-2100 Excitation System: Modular Upgrade and Engineering Application
  • Basler BE1-851 Overcurrent Protection System: A Complete Guide to Professional Debugging and Troubleshooting
  • Basler APR 63-5 Voltage Regulator: Professional Debugging and Troubleshooting Guide for Industrial Generator Excitation Systems
  • Basler BE1-FLEX Protection System: A Complete Guide to Professional Installation, Configuration, and Troubleshooting
  • Debugging and Testing of Basler BE1-700 Relay
  • Basler BE1-87B busbar differential setting test
  • Basler BE1-40Q demagnetization relay setting test
  • Basler BE1-60 Voltage Balance Relay Setting Test
  • Basler BE1-47N Relay Field Setting and Testing Guide
  • Basler BE1-81O/U Frequency Relay: On site Debugging and Protection Configuration Guide
  • Basler BE1-11f Feedline Protection System Debugging and Troubleshooting Guide
  • Basler DECS-250 Excitation System: Installation, Configuration, and Troubleshooting Practice Guide
  • Basler DECS-100 Digital Excitation System Debugging Guide
  • Application Guide for Basler BE1-BPR Circuit Breaker Protection Relay
  • Basler BE1-50/51B-255 Replacement CO Relay Guide
  • Basler BE1-25 synchronous inspection relay principle and testing
  • Basler BE1-51 Time Overcurrent Relay Debugging Guide
  • Practical Guide to Basler DECS-300 Digital Excitation System
  • Mitsubishi FX Series PLC Data Communication Practical Manual
  • Selection of Hirschmann cSCALE S6/C8 Mobile Safety Controller
  • Hirschmann OZD Profi G12D repeater explosion-proof installation configuration
  • Hirschmann OCTOPUS OS20/24 Switch Installation Power Supply
  • Hirschmann RS20/30/40 Switch Selection and PoE Deployment
  • Hirschmann EAGLE One Firewall Installation and Configuration Guide
  • Hirschmann MACH102 Switch Installation and Power Supply Guide
  • Hirschmann MICE MS20/MS30 Installation and DIP Configuration
  • Hirschmann BOBCAT BRS Switch Installation and Power Supply Guide
  • Hirschmann RSB20 Switch Deployment and Redundant Configuration
  • Hirschmann RS20 Basic Switch Installation and Debugging Guide
  • BECKHOFF EP20xx/EP28xx Output Module Installation and Debugging Guide
  • BECKHOFF EL5102 Encoder Terminal Debugging and Troubleshooting
  • BECKHOFF CU8803 Launch Box Installation and Explosion proof Guide
  • BECKHOFF CU20xx/CU22xx Switch Installation and Troubleshooting
  • BECKHOFF AMP8000 Servo Drive Installation and Debugging Manual
  • BECKHOFF EL2911 Safety Feed Terminal Debugging Guide
  • BECKHOFF EL600x/EL602x Serial Port Module Debugging Manual
  • BECKHOFF CP6700 Panel PC Installation and Maintenance Manual
  • BECKHOFF CP70xx panel maintenance and troubleshooting
  • BECKHOFF CP29xx Panel Installation and Troubleshooting
  • Beckhoff C6650-0060 Industrial Control Computer Hardware Architecture and RAID Data Security
  • Beckhoff BK1120/BK1250 EtherCAT Coupling Debugging and KL Terminal Parameterization Complete Guide
  • Beckhoff CX20x0 Embedded Controller Hardware Maintenance and Troubleshooting Complete Manual
  • Beckhoff CP77xx Panel PC Hardware Maintenance and Troubleshooting Complete Guide
  • Beckhoff EL41xx Analog Output Terminal Deep Analysis: Parameter Configuration, Fault Diagnosis, and Firmware Compatibility Guide
  • Beckhoff C63xx industrial computer power supply and shutdown configuration
  • Beckhoff C6920 Industrial Control Computer Selection and Expansion Guide
  • Beckhoff CU8800 USB extender diagnostic guide
  • Beckhoff AX2000 Shutdown Braking and Debugging
  • Beckhoff AX8000 servo installation fuse selection
  • Beckhoff CP27xx Multi finger Touch PC Maintenance
  • Beckhoff CP69xx long-distance transmission and installation
  • Beckhoff CP60xx remote deployment and maintenance
  • Beckhoff CP72xx Installation and Maintenance Complete Manual
  • Beckhoff CP78xx Installation and Troubleshooting Guide
  • Beckhoff CP39xx Control Panel
  • Beckhoff CX8110 Embedded PC
  • Beckhoff CX50x0 series DIN rail embedded industrial PC
  • Beckhoff CP62xx panel PC
  • BECKHOFF C6030 Industrial Control Computer