  • GE IS200ISBBG1A Insync Bus Bypass Card
    ❤ Add to collection
  • GE IS200ISBBG1A Insync Bus Bypass Card

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS200ISBBG1A Insync Bus Bypass Card

    • ¥30287.58
      ¥30254.02
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.820KG
    • Quantity:
    • (Inventory: 35)
Description

GE IS200ISBBG1A Insync Bus Bypass Card


GE IS200ISBBG1A Insync Bus Bypass Card

Part Number IS200ISBBG1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS200ISBBG1A is an Insync bus bypass card developed by GE. It is a part of EX2100 excitation system. The module incorporates a JP1 Interlock Bypass feature, which provides enhanced flexibility and control over the interlock functionality. 

The interlock bypass allows users to temporarily override the interlock system, enabling specific operations or functions to proceed even when certain interlock conditions are present. IS200ISBBG1A FEATURES Compact Size and DIN Rail Mounting: Designed to be compact, allowing for easy installation and integration into control systems. It is typically mounted on DIN rails, which are standard mounting rails used in industrial applications. The module's size and form factor make it suitable for space-constrained environments, providing flexibility in installation. 

Secure Mounting: Securely mounted on the DIN rail using screws. The DIN rail has four factory-drilled holes that align with corresponding holes on the module. The conductive material surrounding these holes ensures proper grounding and electrical connectivity. The holes are conveniently labeled as E1, E2, E3, and E4, aiding in the identification and connection of external components or other boards. Connector Options: Equipped with four connectors to facilitate connections with off-board components or other modules. These connectors include three plug connectors labeled as P1, P2, and P3, and a terminal strip labeled as P4. 

The specific functions of these connectors are identified as follows: P1 - Full Duplex, P2 - XMIT Data Out, P3 - RCV Data In, and P4 - 24 VDC Input. The connectors provide convenient interfaces for data exchange and power supply connections. Terminal Strip and Screw Connections: In addition to the plug connectors, the module features a terminal strip (P4) with two screw connections. This terminal strip offers a flexible and reliable means of connecting external wires or cables. It allows for secure and easily accessible connections, enhancing the overall functionality and versatility of the module. Jumper Position Indication: It includes a jumper whose position and corresponding outcome are clearly indicated on the board's surface. 

This visual indication assists in identifying the current configuration or setting of the jumper. The jumper's position may have an impact on the module's functionality or behavior, and the clear labeling ensures accurate setup and operation. LED Indicators: Features two LEDs, yellow and green, which serve as status indicators. The yellow LED represents XMIT data, providing visual feedback on the transmission of data. The green LED indicates the active state of the interlock, signaling whether the interlock system is engaged or not. These LED indicators provide quick and intuitive visual cues for monitoring the module's status. Integrated Voltage Comparator: The module incorporates an integrated circuit that includes a voltage comparator with a response time of 200ns. 

This voltage comparator plays a critical role in comparing voltages and generating output signals based on predefined thresholds. Its fast response time ensures efficient and accurate voltage comparisons, contributing to the overall performance and reliability of the module. CONTROL POWER SUPPLIES The exciter shares the HMI on turbine generator sets that include Mark VI turbine controls. The HMI is Windows NT-based, with CIMPLICITY operator display software and data highway communication drivers. From the HMI, the operator can initiate commands and view real-time data and alarms on the CIMPLICITY graphic displays. An HMI can be set up as a server or a viewer, and it can include tools and utility programs. 

The exciter is linked to the HMI or HMI/Data Server via the Unit Data Highway (UDH). The network is 10BaseT Ethernet, and uses separately powered network switches. Fiber-optic cables can be used for longer runs. DIN-RAIL-MOUNTED This model is exclusively suitable for DIN-rail-mounted setups. Power supply input for the model operates at 24 VDC. Functionality as an InSync Bus Bypass Card. Within the Mark VI system, it serves as an InSync Bus Bypass Card. The top edge of the board is marked with the board number and code 6BA01. The code 6DA01 is positioned along the bottom edge of the board. BOARD DESIGN AND MOUNTING The board features multiple factory-drilled locations, with four holes (E1, E2, E3, E4) surrounded by conductive material for DIN rail mounting. Two side-by-side relays are located left of the center of the board. The presence of rectifier coils, LED indicators (green and yellow), and a jumper switch are notable. COMPONENTS AND CONNECTIVITY A voltage comparator integrated circuit is present on the board. Connectors include three plugs marked P1 through P3, labeled Full Duplex, Xmit Data Out, and Rcv Data In. A short terminal strip with screw connections is labeled 24 VDC Input. COMPARISON BETWEEN ISBB GROUPS Due to the lack of documentation from General Electric, any major differences between ISBB groups are unknown. 

Visual inspection reveals no apparent differences between the two models. Features such as relays, potentiometers, and LED indicators are common to both models. LED INDICATORS AND DATA STATUS The model incorporates two LEDs: Interlock Active (green) and XMIT Data (yellow). These LEDs signify data and activity status. Whether the LEDs remain solid or flash to indicate faults is uncertain. DATA OUTPUT INDICATION The XMIT Data LED assists in indicating data transmission or reception. A labeled plug for XMIT Data out facilitates data outputs. 

 CONNECTORS P1-Full Duplex: Plug connector for full-duplex communication. P2-XMIT Data Out: Plug connector for transmitting data. P3-RCV Data In: Plug connector for receiving data. P4-24 VDC Input: Terminal strip with two screw connections for a 24 VDC input. MOUNTING Typically designed to be mounted on DIN rails. The board can be mounted using screws to four of its six factory-made drill holes. The holes used for mounting are labeled E1, E2, E3, and E4 and are ringed with a conductive material.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Bosch Rexroth D8_5 EDD-XZ Directional Valve Selection and Configuration Guide
  • Bosch Rexroth VT-MSPA Proportional Valve Amplifier Configuration and Troubleshooting Guide
  • Bosch Rexroth CDH1/CGH1/CSH1 Square Cylinder Selection and Compression Rod Verification
  • Bosch Rexroth CD/CG/CS Hydraulic Cylinder Installation, Maintenance, and Troubleshooting Guide
  • Bosch Rexroth VDP 16.3/40.3/60.3 Operating Terminal Installation and Troubleshooting Guide
  • Bosch Rexroth MSK Servo Motor Installation, Maintenance, and Troubleshooting Guide
  • Bosch Rexroth IndraMotion MTX CNC System Selection and Backup Guide
  • GE MV3000 Inverter Cooling Fan Replacement and Upgrade Plan
  • Bosch Rexroth Indramat DIAX04 HDD/HDS Drive Controller Planning Guide
  • Technical Analysis and Selection Guide for Bosch Rexroth AZPF Gear Pump
  • Renesas ICL232 Transceiver Application Guide
  • Rexroth VT-VRPA2 Valve Amplifier Debugging Guide
  • Rexroth IndraDrive C HCS Debugging Guide
  • Rexroth IndraControl L25 Controller Selection Guide
  • Rexroth Indramat BTV20.3 Operation Terminal Installation and Maintenance Guide
  • Bosch Rexroth Indramat PPC-R02 Controller Replacement Guide
  • Phoenix Contact Inline I/O System Selection Guide
  • Rexroth VCP 08 Operating Terminal Selection and Installation Guide
  • Rexroth IndraDyn H Spindle Motor Planning Guide
  • Detailed explanation of ElectroLogIXS VLC interlocking signal controller
  • Yokogawa AIP830 Single Circuit Operation Keyboard
  • Yokogawa RAMC flowmeter selection and troubleshooting
  • YASKAWA GA500 frequency converter troubleshooting
  • TRACO TIS600 power supply
  • Sigmatek ETV-0851 Control Panel Troubleshooting
  • Allen Bradley Quest AN-X2-AB-DHRIO Remote I/O Adapter Integration and Troubleshooting
  • Meggitt RPS6U power supply
  • Kongsberg RCU500 Controller Integration and Fault Diagnosis Guide
  • KBAC series frequency converter installation and fault diagnosis guide
  • EXOR effectiveness View eV058 series HMI industrial panel
  • Emerson OCR3000 Controller Troubleshooting Guide
  • Emerson Ovation OCR1100 Controller Maintenance and Troubleshooting
  • Elmo G-TUB30 Driver Troubleshooting Guide
  • Troubleshooting and Optimization of Basler A400 Series Camera
  • Troubleshooting and Maintenance of Automated Logic I/O Expansion Module
  • Troubleshooting and Maintenance of Aerotech UNIDEX 100 Controller
  • ADVANEST R6144 calibration source troubleshooting
  • Troubleshooting and Calibration of ABB Millmate Tension Gauge
  • ABB NGC8206 natural gas chromatograph troubleshooting and maintenance
  • ABB AO2040-CU Ex Explosion proof Analyzer Troubleshooting
  • ABB PFEA113 Tension Controller Troubleshooting Guide
  • ABB PFEA111/112/122 Tension Controller Troubleshooting Guide
  • ABB LS4000 laser analyzer
  • ABB SPAU 341 C Voltage Regulator Troubleshooting Guide
  • Analysis and Fault Diagnosis of ABB V-Contact VSC Medium Voltage Contactor
  • ABB UNITOL 1020 Compact Digital Excitation Regulator AVR Replacement and Troubleshooting
  • ABB UNITROL 1000 excitation system replacement and troubleshooting
  • ABB SYNC HROTACT 5 synchronization module troubleshooting and replacement
  • ABB SYNC HROTACT 5 Synchronization Device Replacement and Troubleshooting Guide
  • ABB Symphony Plus Module Replacement and Upgrade Guide
  • ABB S900 I/O Hazardous Area Deployment and Maintenance
  • ABB System 800xA Operations and Troubleshooting
  • ABB PCS6000 Troubleshooting and Module Replacement Guide
  • ABB PCS 8000 pumped storage excitation
  • ABB Procontrol P13 Bus Coupling Upgrade Guide
  • ABB NextMove ESB-2 Fault Diagnosis and Configuration Practice
  • ABB MEGADRIVE-LCI Maintenance and Selection Practice
  • ABB MEGADRIVE LCI Transmission Vibration Suppression
  • ABB MEGADRIVE LCI Water Cooling Troubleshooting and Maintenance Guide
  • Practical Maintenance and Common Troubleshooting of ABB DCS880
  • ABB SDCS-IOB-3 Replacement and Troubleshooting
  • ALSTOM MAE99-04 Serial Interface Terminal Panel Maintenance and Troubleshooting
  • Installation and Maintenance of ALSTOM ALSPA MV3000 Handheld Operator
  • Maintenance and commissioning of ABB KPM KB2 paper breakage detector
  • Maintenance and troubleshooting of ABB SCC-K converter
  • ABB SCC Gas Preprocessing System Maintenance and Selection Guide
  • ABB NGC8209 gas chromatograph maintenance
  • Maintenance and troubleshooting of ABB DCS DC speed controller
  • ABB ASTAT Crane Controller Maintenance and Debugging Guide
  • ABB ACS800 TIM foil IGBT
  • ABB LS25 laser analyzer troubleshooting
  • ABB REM54 motor terminal troubleshooting
  • ABB REL670 distance protection and troubleshooting
  • ABB SUE3000 switching device troubleshooting
  • ABB REF630 feeder protection
  • ABB REF620 (Relion 620 series) feeder protection and measurement device
  • ABB E1B-A Circuit Breaker
  • ABB FCU400-IR temperature measurement system troubleshooting
  • ABB TZIDC-200 locator configuration and troubleshooting
  • ABB DHH805-A Handheld Operator Configuration and Activation Guide
  • ABB SACO 16D1 alarm device replacement and troubleshooting
  • ABB 5SHY3545L0016 IGCT module replacement guide
  • ABB S600 I/O Module Replacement and Troubleshooting Guide
  • ABB NextMove e100 motion controller troubleshooting guide
  • Rockwell PowerFlex 700 Inverter Replacement and Troubleshooting Guide
  • Allen Bradley 1762-OW16 Output Module
  • Allen Bradley IntelliVAC 1503VC Series E Control Module
  • Allen‑Bradley IntelliVAC ™ 1503VC contactor control module
  • Woodward SOGAV 250 solenoid valve drives gas intake valve for troubleshooting
  • Woodward easyYgen-3500XT-P1 obstacle removal
  • Woodward CPC-II electro-hydraulic current pressure converter
  • UniOP ePALM10 Handheld HMI
  • TMEIC TMdrive-30 frequency converter
  • TEWS TVME200 Carrier Board Configuration and Troubleshooting Guide
  • TDK Alpha 400 Power Troubleshooting Guide
  • STUCKE SYMAP relay
  • Deployment and troubleshooting of Softing CAN-AC2-PCI interface card
  • Installation, Maintenance, and Troubleshooting of Siemens C7-623/624
  • Foxboro Compact 200 Series 16 Slot Bottom Plate Deployment and Maintenance Guide
  • Foxboro 84F/84W Vortex Flow Meter Selection and Debugging Guide
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module