GE IS200TTURH1A Thermocouple Input Terminal Board
GE IS200TTURH1A Thermocouple Input Terminal Board
Part Number IS200TTURH1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI Function Module Availability In StockIS200TTURH1A is a Primary Turbine Protection Input Terminal Board manufactured and designed by General Electric as part of the Mark VI Series used in GE Speedtronic Gas Turbine Control Systems. The Primary Turbine Protection Input terminal board works with VTUR and has the following inputs and outputs: Twelve passive pulse rate devices sensing a toothed wheel to measure the turbine speed Generator voltage and bus voltage signals from potential transformers 125 V dc output to the main breaker coil for automatic generator synchronizing Inputs from the shaft voltage and current sensors to measure induced shaft voltage and current TTUR has three relays, K25, K25P, and K25A, that all have to close to provide 125 V dc power to close the main breaker, 52G.
The speed signal cable to VTUR uses the JR5 connector, and the other signals use the JR1 connector. For TMR systems, signals fan out to the JR5, JS5, JT5, JR1, JS1, and JT1 connectors. INSTALLATION: TTUR Terminal Board Wiring: Connect the shaft pick-ups, magnetic pick-ups, breaker relays, and I/O terminal blocks TB1 and TB2 to the terminal boards. There are 24 terminals on each block, which may accept wires up to #12 AWG, and they are each attached with two screws. A shield termination strip linked to the chassis ground is located directly left of each terminal block.
OPERATION: Turbine speed can be determined in simplex applications using up to four pulse rate signals. Along with VTUR, the turbine controller, and the excitation system, the generator and bus voltages are fed into TTUR for automatic synchronization. The main breaker relay coil, 52G, is controlled by TTUR, which also has permissive generator synchronizing relays.
Features
Single-Slot Module
SNP/SNP-X Protocol (master, slave)
CCM Protocol (master, slave, peer)
RTU Modbus Protocol (slave only)
Supports connection to MS-DOS or Windows
programming and configuration software package (monitor only)
12 Mhz, 80C186 Microprocessor
Two RS-422/RS-485 or RS-232 Serial Ports
CCM, RTU and SNP/SNP-X Available on Either or Both Ports
Simultaneous Communications on Both Ports (up to 9.6 Kbps, or 19.2 Kbps individually)
High Performance Access to PLC Memory
Three Status LEDs
Reset pushbutton
Soft Switch Configuration (no switches or jumpers)
No Battery Required
Ease of Use
• Simple and powerful instruction set
• One-axis or two-axis motion programs with synchronized block start
• Program support for a short motion program (called Program Zero) which can be created in the MS-DOS programming software configuration function
• Nonvolatile (flash) storage for 10 programs and 40 subroutines
• User scaling of programming units (in Standard mode only)
• Generic programming using command parameters as operands for Acceleration, Velocity, Move and Dwell commands
• Configured with MS-DOS configuration software
For more information, you can call 15305925923