Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS200VAICH1C VME ANALOG INPUT CARD
    ❤ Add to collection
  • GE IS200VAICH1C VME ANALOG INPUT CARD

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS200VAICH1C VME ANALOG INPUT CARD

    • ¥23650.00
      ¥24520.00
      ¥23650.00
      ¥23650.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:5.600KG
    • Quantity:
    • (Inventory: 36)
Description

GE IS200VAICH1C VME ANALOG INPUT CARD


GE IS200VAICH1C VME ANALOG INPUT CARD

Part Number IS200VAICH1C Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VIe Function Module Availability In StockIS200VAICH1C is a VME Analog Input/Output (VAIC) Board manufactured by General Electric as a part of the Mark VI Series used in gas turbine control systems. The Analog Input/Output (VAIC) board accepts 20 analog inputs and controls 4 analog outputs. Each terminal board accepts 10 inputs and 2 outputs. Cables connect the terminal board to the VME rack where the VAIC processor board is located. VAIC converts the inputs to digital values and transfers them over the VME backplane to the VCMI board, and then to the controller. 

For outputs, the VAIC converts digital values to analog currents and drives these through the terminal board into the customer circuit. VAIC supports both simplex and triple modular redundant (TMR) applications. When used in a TMR configuration, input signals on the terminal board are fanned out to three VME board racks R, S, and T, each containing a VAIC. Output signals are driven with a proprietary circuit that creates the desired current using all three VAICs. In the event of a hardware failure, the bad VAIC is removed from the output and the remaining two boards continue to produce the correct current. When used in a simplex configuration, the terminal board provides input signals to a single VAIC, which provides all of the currents for outputs. COMPATIBILITY There are two generations of the VAIC board with corresponding terminal boards. 

The original VAIC includes all versions prior to and including VAICH1C. VAICH1B is included in this generation. When driving 20 mA outputs these boards support up to 500 load resistance at the end of 1000 ft of #18 wire. This generation of the board requires terminal board TBAIH1B or earlier for proper operation. They also work properly with all revisions of DTAI terminal boards. The newest VAICH1D and any subsequent releases are designed to support higher load resistance for 20 mA outputs drive voltage: up to 18 V is available at the terminal board screw terminals. This permits operation into loads of 800 with 1000 ft of #18 wire with margin. This generation of the board requires TBAIH1C or later, or any revision of STAI. 

 INSTALLATION Power down the VME processor rack Slide in the board and push the top and bottom levers in with your hands to seat its edge connectors Tighten the captive screws at the top and bottom of the front panel OPERATION The VAIC board accepts 20 analog inputs, controls 4 analog outputs, and contains signal conditioning, an analog MUX, an A/D converter, and a D/A converter. The type of analog input, either voltage, 4-20 mA, or terminal board. Two of the four analog output circuits are 4-20 mA and the other two can be configured for 4-20 mA or 0-200 mA. Inputs and outputs have noise suppression circuitry to protect against surge and high-frequency noise. VAIC and Analog Input Terminal Board, Simplex System In a TMR system, analog inputs fan out to the three control racks from JR1, JS1, and JT1. The 24 V dc power to the transducers comes from all three VME racks and is diode OR selected on the terminal board. 

Each analog current output is fed by currents from all three VAICs. The actual output current is measured with a series resistor, which feeds a voltage back to each VAIC. The resulting output is the voted middle value (median) of the three currents. The following figure shows VAIC in a TMR arrangement. Transmitters/transducers can be powered by the 24 V dc source in the control system or can be powered independently. Diagnostics monitor each output and a suicide relay disconnects the corresponding output if a fault cannot be cleared by a command from the processor. Hardware filters on the terminal board suppress high-frequency noise. Additional software filters on VAIC provide configurable low pass filtering. 

 COMPRESSOR STALL DETECTION VAIC firmware includes gas turbine compressor stall detection, executed at 200 Hz. Two stall algorithms can be selected. Both use the first four analog inputs, scanned at 200 Hz. One algorithm is for small LM gas turbines and uses two pressure transducers (refer to the figure, Small (LM) Gas Turbine Compressor Stall Detection Algorithm). The other algorithm is for heavy-duty gas turbines and uses three pressure transducers (refer to the figure, Heavy Duty Gas Turbine Compressor Stall Detection Algorithm). Real-time inputs are separated from the configured parameters for clarity. The parameter CompStalType selects the type of algorithm required, either two transducers or three. 

PS3 is the compressor discharge pressure. A drop in this pressure (PS3 drop) indicates a possible compressor stall. The algorithm also calculates the rate of change of discharge pressure, dPS3dt, and compares these values with configured stall parameters (KPS3 constants). The compressor stall trip is initiated by VAIC, which sends the signal to the controller where it is used to initiate a shutdown. The shutdown signal can be used to set all the fuel shut-off valves (FSOV) through any relay output. Three LEDs at the top of the VAIC front panel provide status information. The normal RUN condition is flashing green, and FAIL is a solid red. The third LED displays STATUS and is normally off, but displays a steady orange if a diagnostic alarm condition exists on the board. Diagnostic checks include the following: Each analog input has hardware limit checking based on preset (non-configurable) high and low levels set near the ends of the operating range. If this limit is exceeded a logic signal is set and the input is no longer scanned. If any L3DIAG_VAIC, which refers to the entire board. Details of the individual diagnostics are available from the toolbox. 

The diagnostic signals can be individually latched, and then reset with the RESET_DIA signal. Each input has system limit checking based on configurable high and low levels. These limits can be used to generate alarms and can be configured for enabling/disabling, and as latching/non-latching. RESET_SYS resets the out-of-limits. In TMR systems, if one signal varies from the voted value (median value) by more than a predetermined limit, that signal is identified and a fault is created. This can provide an early indication of a problem developing in one channel. Monitor D/A outputs, output currents, total current, suicide relays, and 20/200 mA scaling relays; these are checked for reasonability and can create a fault. TBAI has its own ID device that is interrogated by VAIC. The board ID is coded into a read-only chip containing the terminal board serial number, board type, revision number, and the JR, JS, and JT connector location. When the chip is read by the I/O processor and a mismatch is encountered, a hardware incompatibility fault is created.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ROSS Pneumatic Valve Full Series
  • BD SENSORS DMP 333 High Pressure Transmitter
  • OE Max Controls NX70 series PLC
  • SAIA PCD4.W500/W600 Intelligent Simulation Module
  • Saia Burgess PCD4.U100 Migration Kit
  • SAIA PCD1 Controller Full Series
  • SAIA Burgess PCD2.H110 Counting and Measurement Module
  • SAMSON Type 3434 Pneumatic Controller Module
  • SanDisk iNAND Flash and microSD
  • Optimus® Product Family of SAS SSDs
  • SANMOTION PB servo stepper
  • ADCA AVM/AVF234S electric actuator
  • SBS Technologies VIPC616 Carrier Board
  • SBS Technologies VIPC616 VME Carrier Board
  • Greenspring P2 Video Graphics Controller
  • ABB UniPack-S Steel Compact Substation
  • Schaffner Ecosine ® Economy Line FS 42842 Compact Passive Harmonic Filter
  • Schenck Process INTECONT Tersus Weighing Instrument
  • ENTRELEC contactor relay
  • Smiths Connectors MHD/MDD/MDP CONNECTOR SERIES PCB High Density Connectors
  • SEW EURODRIVE DFP21B bus interface
  • SEW-EURODRIVE MOVIDRIVE B Series Manual
  • SEW Eurodrive R series parallel axis reduction motor
  • SEW EURODRIVE DFY/DFS Synchronous Motor Guide
  • SEW MOVITRAC 31C Installation and Debugging
  • SEW EURODRIVE MOVIDYN communication interface
  • SEW MOVIDRIVE UL compliant installation
  • SEW MOVIDRIVE bus positioning
  • SEW MOVIDYN ® Series servo controller
  • SEW MOVIDRIVE MD60A Inverter Guide
  • BTicino Megatiker M5 electronic circuit breaker
  • BTicino Megatiker M4 Circuit Breaker
  • BTicino Megatiker M3 160 Circuit Breaker
  • BTICINO MEGATIKER Circuit Breaker Series
  • Elmex Industrial Automation Control Products
  • Danfoss VLT ® Series 3000 series adjustable frequency drive
  • Rockwell Automation SLC 500 Series Programmable Logic Controller
  • YOKOGAWA CENTUM CS 3000 Integrated Production Control System
  • OMRON SYSMAC CS Series CS1G/H-CPU  H Programmable Controller
  • MEGGITT TQ TQ 422/432 Eddy Current Measurement System
  • MEGGITT VM600 machinery protection system (MPS)
  • IbaDeskline SAS Industrial Computer
  • IbaDAQ-C independent data acquisition device
  • IbaFOB io ExpressCard fiber optic interface card
  • IbaPADU-S-IT-16 modular central unit
  • YASKAWA ∑ - II Series SGMBH/SGDH AC Servo System
  • IbaBM CAN CAN/CANopen bus sniffer
  • IbaLink-SM-128V-i-2O VMEbus interface board
  • GE Fanuc Series 90-30 PLC Hardware System
  • Automation Direct GS2 Series Frequency Inverter Specifications and Selection
  • OMRON SYSDRIVE 3G3MV Multi-functional Compact Frequency Inverter In-depth Technical Guide
  • Danfoss VACON NXI High Power Frequency Inverter Operation Manual
  • Saia PCD4.U100 Kit System Upgrade Guide
  • Yaskawa Sigma II Series NS300 DeviceNet Application Module Deep Technical Guide
  • OMRON SSS Software C-series PLC Operating Instructions
  • Kollmorgen SERVOSTAR S Digital Servo Drive Guide: From Installation to Mastery
  • Omron C200HX/HG/HE PLC Installation Guide
  • SIEMENS SINAMICS S120 Servo Drive System Application Guide
  • Emerson ControlWave Micro Hybrid Controller
  • ABB 800xA with Advant Master integrated configuration
  • OMRON FQM1 Motion Controller Instruction System
  • Schneider Easergy P5 Communication Protocol Complete Guide
  • ABB JOKAB SAFETY Pluto series safety PLC
  • Lenze HMI EL 100: Intelligent Human Machine Interface
  • Pilz PSEN opII4H Safety Light Curtain Complete Guide
  • Danfoss VACON ® NXP and VACON ® NXC series AC frequency converter
  • EATON Crane Control System Complete Guide
  • ProSoft MVI56-PDPMV1: ProFIBUS DPV1 Master Module Complete Guide
  • DEIF XDi series FLEXIBLE DISPLAY INDICATORS
  • DEIF AGC 100 series generator set controller
  • DEIF AGC-3 Automatic Generator Set Controller
  • DEIF Multi line 2 Controller Installation Guide
  • KONGSBERG AIS BS600 shipborne automatic identification system base station
  • KONGSBERG HMS 300 Helicopter Deck Monitoring System
  • Honeywell HPM Series Particulate Matter Sensors
  • HONEYWELL Expert C300 Controller
  • HONEYWELL HCiX series touch panel operation interface
  • Honeywell T901Px1A Inert Gas Pressure & Temperature Transmitter for Liquid Cargo
  • HONEYWELL Expert Series-C I/O Module
  • HONEYWELL INTELLIKNIGHT®MODEL 5700 Addressable Fire Alarm Control Panel
  • HONEYWELL Expert PKS C300 Controller
  • HONEYWELL Experion Local Control Network
  • HONEYWELL IRIS P522 Flame Monitoring System
  • HONEYWELL 7800 series combustion controller
  • HONEYWELL Sensepoint XCD Flammable, toxic and oxygen gas detector for industrial applications
  • HONEYWELL Sensepoint XCD Gas Detector
  • HONEYWELL Series 61 and Series 62 Modutrol IV™ Motors
  • HONEYWELL M6161, M6181, M6184, M6191, M6194 models Modutrol IV ™ motor
  • KONGSBERG C-series precision cutting system: versatile digital cutting solution
  • KONGSBERG DPS i2 Inertial Navigation System: A New Benchmark for GNSS and INS Fusion Positioning
  • KONGSBERG DPS 114 Durable and Reliable DGNSS (DGPS/DGGLONASS) Sensor
  • KONGSBERG DZ-110/U transmitter safety barrier unit
  • KONGSBERG DZ-120 Zener Safety Barrier Unit
  • KONGSBERG MST 319/324/342 series mini SSBL responder
  • BridgeMaster E 180 and 250 EPA (L) Series of Marine Radars
  • KONGSBERG K-Chief 600 Control Room Panel (CRP) for Ship Automation System
  • KONGSBERG K-Master Bridge Solution: Comprehensive Enhancement of Ship Operation Efficiency and Safety
  • KONGSBERG SR/SV Steering Servo Maintenance Comprehensive Guide
  • KONGSBERG GT300 pressure transmitter
  • KONGSBERG's RMP420 Remote Multifunctional I/O Module
  • KONGSBERG WCU LED Control Unit Application Guide
  • KONGSBERG K-Nav Navigation Product Series
  • KONGSBERG K-Chief Ship Automation System
  • KONGSBERG RCU 500 Remote Controller
  • Kongsberg ACC20 Engine Safety Unit: Redundant Guardian of Industrial Power
  • KUKA KR C5 Robot Controller
  • KUKA KR C4 compact robot controller
  • KUKA KR C2 edition2005 Robot Controller Operation Manual
  • EATON A200 Size 5 Motor Controller
  • Eaton MICRO PANEL XV-152 Industrial Tablet Operating Manual
  • Eaton B-Line series product line
  • EATON Time delay undervoltage module
  • Eaton 5P series UPS products
  • Cooper Crouse Hinds EVLS HAZARD-GARD Explosion proof Lamp Installation and Maintenance
  • Eaton EX series UPS products
  • Durant Ambassador 57600 Series Counting Controller
  • Eaton xEnergy Safety Ci Insulated Distribution Enclosure
  • EATON XP-702 MICRO PANEL Industrial grade Human Machine Interface Equipment
  • EATON SPD series surge protector
  • EATON MVX9000 Variable Frequency Drive
  • EATO NeasyE4 Micro PLC Easy Control
  • EATON Cutler Hammer FP-4000 Medium Voltage Feedline Protection Relay
  • EATON FP-4000 feeder protection relay
  • EATON XT series stabilizing pump control box
  • EATON MP-4000 motor protection relay
  • EATON ELPRO 245U-E series industrial wireless Ethernet products
  • EATON MTL4850 HART multiplexer complete guide
  • Eaton Ambassador Counter Complete Guide