Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS200VRTDH1C RTD Processor Board
    ❤ Add to collection
  • GE IS200VRTDH1C RTD Processor Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS200VRTDH1C RTD Processor Board

    • ¥22500.00
      ¥24520.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:5.600KG
    • Quantity:
    • (Inventory: 33)
Description

GE IS200VRTDH1C RTD Processor Board


GE IS200VRTDH1C RTD Processor Board

Part Number IS200VRTDH1C Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI Function Module Availability In StockIS200VRTDH1C is an RTD Processor Board manufactured by General Electric as part of the Mark VI Series used in gas turbine control systems. There are 16 three-wire RTD inputs on the Resistance Temperature Device (RTD) processor board (VRTD). The RTD terminal board is wired to receive these inputs (TRTD). 

Additionally, a DRTD DIN-type terminal board may be connected. The terminal board is connected to the VME rack, which holds the VRTD processor board, through cables with molded fittings. The signals produced when the RTDs are excited by the VRTD are then returned to the VRTD. The inputs are converted to digital temperature values by the I/O processor board, which then sends those readings across the VME backplane to the VCMI and ultimately to the controller. 

 INSTALLATION: Turn off the processor rack for the VME. Insert the VRTD board, then, using your hands, press the top and bottom levers into the seat the edge connectors. Tighten the captive screws on the front panel's top and bottom. OPERATION: Each RTD is provided with a 10 mA dc multiplexed excitation current from VRTD via the terminal board (not continuously). As a result, the VRTD receives the signal. The VRTD board's VCO type A/D converter makes use of sampling counters and voltage to frequency converters. When scanning in normal mode or in fast mode, the converter samples each signal and the excitation current four times every second and 25 times every second, respectively, with a time sample interval based on the frequency of the power system. 

The digital signal processor utilizes software to conduct linearization for a choice of 15 RTD types. By using out-of-range values, RTD open and short circuits are found. To avoid damaging effects on other input channels, an RTD that is found to be outside of hardware restrictions is deleted from the scanned inputs. After 20 seconds, repaired channels are automatically restored unless manually restored beforehand. Inputs from three VRTD boards in the R, S, and T racks are fanning out to give redundant RTD inputs for TRTDH1B. Although the inputs comply with the same environmental, coding, resolution, suppression, and function requirements as the TRTDH1C terminal board, the quick scan is not accessible. High-frequency decoupling to the ground is included at signal input for all RTD signals. 

In order to prevent any RTD signals in the control database from being lost due to the loss of a single cable or VRTD, redundant pacemakers are used to coordinate RTD multiplexing on the VRTD boards. When R is reading RTD3, S is reading RTD5, T is reading RTD7, and so on. VRTD boards in R, S, and T read RTDs simultaneously but are skewed by two RTDs. This prevents the same RTD from being excited by two VRTDs at once and leads to inaccurate readings. A full-scale input range of 0.3532 to 4.054 V is supported for RTD inputs. DIAGNOSTICS: The VRTD front panel's three LEDs at the top display status data. Normal RUN conditions are flashing green, while FAIL conditions are solid red. When a diagnostic alert condition is present on the board, the third LED, which is typically off, turns steadily orange. Hardware limit checking and system limit checking are two diagnostic check kinds that are applied to all inputs, and they are as follows: Every RTD type features hardware limit checking based on predetermined (non-configurable) high and low levels that are placed close to the working range's endpoints. 

When this threshold is reached, the input is no longer scanned and a logic signal is set. When any of the 16 inputs' hardware restrictions are reached, a composite diagnostic warning called L3DIAG VRTD that refers to the entire board is generated. The toolbox contains information about each diagnostic in detail. The RESET DIA signal can be used to individually latch each diagnostic signals before resetting them all. Based on programmable high and low values, each RTD input provides system limit checking. 

These restrictions have to enable/disable, latching/non-latching, and alarm-generating capabilities. Resetting the out-of-limit signals is done using RESET SYS. The resultant composite diagnostic is present in each controller in TMR systems where limit logic signals are voted on. Each RTD's resistance is measured and compared to the appropriate value, and if it is high or low, a defect is created. The I/O processor board queries each connector's unique ID device, which is attached to each connector. A read-only chip with the terminal board serial number, board type, revision number, and location of the J1 connector is where the terminal board ID is encoded. A hardware incompatibility fault is created if a mismatch is found.

SPECIFICATIONS

Part Number: IS200VRTDH1C
SKU: IS200VRTDH1C
Manufacturer: General Electric
Series: Mark VI
Product Type: Processor Board
Number of Channels: 16
A/D Converter Resolution: 14-bit resolution
Availability: In Stock
Country/Region of Manufacture: United States
Repair: 3-7 Days
Manual: GEH-6421J

For more information, you can call 15305925923

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ADLINK NuPRO-E320 motherboard deployment and tuning guide
  • ADLINK NuPRO-800 Dual PIII Industrial SBC Maintenance and Upgrade Guide
  • ADLINK NuPRO-598 SBC Maintenance Practical Guide
  • ADLINK MXC-6300 Fanless Embedded Industrial Control Computer Deployment Guide
  • ADLINK Express-BASE7 Carrier Board Quick Deployment and Debugging Guide
  • ADLINK DLAP-211 Edge AI Platform Selection and Deployment Guide
  • ADLINK 7230 Series Isolation DIO Card Selection and Engineering Application Guide
  • ADLINK cPCI-6965 SBC Embedded Installation and BIOS Tuning Guide
  • ADLINK 7200 Series High Speed DIO Card Practical Guide
  • ADLINK DLAP Series Edge AI Acceleration Platform Selection and Deployment Practical Guide
  • DEIF TCM-2 thyristor control module: Wind power cut in control engineering guide
  • DEIF MVR-200 Medium Voltage Relay: Installation and Wiring Engineering Guide
  • DEIF MDR-2 Differential Relay: Engineering Guide for Generator Differential Protection
  • DEIF Delomatic 3 AOM: Engineering Guide for Analog Output Modules
  • DEIF AGI 400 Graphic Interface: Ship and Industrial HMI Solution
  • DEIF BRW-1 Marine Instruments: Installation and Calibration Guide for Offshore Bridge Indicators
  • DEIF AGC 200 Controller: Quick Deployment and Configuration Guide for Generator Sets
  • DEIF AGC-2 Controller: The Ultimate Guide to Automatic Control and Protection of Generator Sets
  • ABB SPA-ZC400 Gateway: REM54x Access to IEC 61850 Ultimate Engineering Guide
  • ABB REM 543/545 Terminal
  • Modular Architecture Analysis of DEIF PPU 300 Ship Generator Controller
  • DEIF DM-4 Marine&Offshore Ship Power Management System
  • Detailed Explanation of DEIF Delomatic Generator Control System Architecture
  • DEIF AGC-4 Mk II Generator Controller Depth Configuration Guide
  • DEIF AGC-4 Generator Controller Configuration and Debugging Guide
  • DEIF PPM Power Management System Operation and Troubleshooting
  • Installation and wiring of DEIF Multi line 2
  • Practical configuration and maintenance of Beckwith M-6280 capacitor bank controller
  • Beckwith M-3311 Transformer Protection Relay Setting and Engineering Application
  • Beckwith M-3311A Transformer Protection Relay Configuration and Optimization Guide
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit
  • Installation and I/O configuration of DEIF PPM-3 power management module
  • Beckwith M-3520 Interconnection Protection Relay
  • Beckwith M-3430 Generator Protection Relay
  • Beckwith M-2293B adapter panel replacement GE regulator guide
  • Selection and Networking of Beckwith M-2001C Digital Voltage Regulating Controller
  • Beckwith M-2001B Digital Voltage Regulating Controller
  • Beckwith M-0388/M-0389 Synchronous Inspection Relay Application Guide
  • Beckwith M-0193B Synchronizer Debugging and System Integration Guide
  • Beckwith M-0115A Parallel Balance Module Debugging Guide
  • Beckwith M-0067E On Load Voltage Regulating Controller Selection and Debugging Guide
  • Debugging and Fault Handling of Beckwith M-4272 Digital Busbar Conversion System
  • Beckwith M-3311A Transformer Protection Relay Debugging Guide
  • Beckwith M-3425A Generator Protection Relay Debugging Guide
  • Setting and troubleshooting of Basler BE1-27/59 voltage relay
  • Debugging and troubleshooting of Basler AVC63-12/AVC125-10 voltage regulator
  • Basler L301kc Line Array Camera Technology and Troubleshooting
  • Selection and Debugging of Basler CBS 212A Current Boosting System
  • Selection and commissioning of Basler BE3-25 synchronous inspection relay
  • Basler BE1-32R/32O/U Direction Power Relay Setting and Testing Guide
  • Basler PRS 250 Synchronous Relay Maintenance and Replacement Guide
  • Basler piA2400-17gc Industrial Camera Replacement and Optimization Guide
  • Basler BE1-11g Generator Protection System
  • Basler VR63-4C/UL Voltage Regulator
  • Basler BE1-DFPR feeder protection relay
  • Basler CBS 310/320 Current Boosting System
  • Basler UFOV 250A/260A protection module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F Regulator
  • Basler DECS-400 excitation system
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection
  • Basler SSR Static Voltage Regulator: A Complete Guide to Debugging and Troubleshooting
  • Basler SR4A/SR8A Voltage Regulator: Detailed Debugging and Troubleshooting Explanation
  • Basler BE2000E Voltage Regulator: Replacement and Application Details
  • Basler DECS-2100 Excitation System: Modular Upgrade and Engineering Application
  • Basler BE1-851 Overcurrent Protection System: A Complete Guide to Professional Debugging and Troubleshooting
  • Basler APR 63-5 Voltage Regulator: Professional Debugging and Troubleshooting Guide for Industrial Generator Excitation Systems
  • Basler BE1-FLEX Protection System: A Complete Guide to Professional Installation, Configuration, and Troubleshooting
  • Debugging and Testing of Basler BE1-700 Relay
  • Basler BE1-87B busbar differential setting test
  • Basler BE1-40Q demagnetization relay setting test
  • Basler BE1-60 Voltage Balance Relay Setting Test
  • Basler BE1-47N Relay Field Setting and Testing Guide
  • Basler BE1-81O/U Frequency Relay: On site Debugging and Protection Configuration Guide
  • Basler BE1-11f Feedline Protection System Debugging and Troubleshooting Guide
  • Basler DECS-250 Excitation System: Installation, Configuration, and Troubleshooting Practice Guide
  • Basler DECS-100 Digital Excitation System Debugging Guide
  • Application Guide for Basler BE1-BPR Circuit Breaker Protection Relay
  • Basler BE1-50/51B-255 Replacement CO Relay Guide
  • Basler BE1-25 synchronous inspection relay principle and testing
  • Basler BE1-51 Time Overcurrent Relay Debugging Guide
  • Practical Guide to Basler DECS-300 Digital Excitation System
  • Mitsubishi FX Series PLC Data Communication Practical Manual
  • Selection of Hirschmann cSCALE S6/C8 Mobile Safety Controller
  • Hirschmann OZD Profi G12D repeater explosion-proof installation configuration
  • Hirschmann OCTOPUS OS20/24 Switch Installation Power Supply
  • Hirschmann RS20/30/40 Switch Selection and PoE Deployment
  • Hirschmann EAGLE One Firewall Installation and Configuration Guide
  • Hirschmann MACH102 Switch Installation and Power Supply Guide
  • Hirschmann MICE MS20/MS30 Installation and DIP Configuration
  • Hirschmann BOBCAT BRS Switch Installation and Power Supply Guide
  • Hirschmann RSB20 Switch Deployment and Redundant Configuration
  • Hirschmann RS20 Basic Switch Installation and Debugging Guide
  • BECKHOFF EP20xx/EP28xx Output Module Installation and Debugging Guide
  • BECKHOFF EL5102 Encoder Terminal Debugging and Troubleshooting
  • BECKHOFF CU8803 Launch Box Installation and Explosion proof Guide
  • BECKHOFF CU20xx/CU22xx Switch Installation and Troubleshooting
  • BECKHOFF AMP8000 Servo Drive Installation and Debugging Manual
  • BECKHOFF EL2911 Safety Feed Terminal Debugging Guide
  • BECKHOFF EL600x/EL602x Serial Port Module Debugging Manual
  • BECKHOFF CP6700 Panel PC Installation and Maintenance Manual
  • BECKHOFF CP70xx panel maintenance and troubleshooting
  • BECKHOFF CP29xx Panel Installation and Troubleshooting
  • Beckhoff C6650-0060 Industrial Control Computer Hardware Architecture and RAID Data Security
  • Beckhoff BK1120/BK1250 EtherCAT Coupling Debugging and KL Terminal Parameterization Complete Guide
  • Beckhoff CX20x0 Embedded Controller Hardware Maintenance and Troubleshooting Complete Manual
  • Beckhoff CP77xx Panel PC Hardware Maintenance and Troubleshooting Complete Guide
  • Beckhoff EL41xx Analog Output Terminal Deep Analysis: Parameter Configuration, Fault Diagnosis, and Firmware Compatibility Guide
  • Beckhoff C63xx industrial computer power supply and shutdown configuration
  • Beckhoff C6920 Industrial Control Computer Selection and Expansion Guide
  • Beckhoff CU8800 USB extender diagnostic guide
  • Beckhoff AX2000 Shutdown Braking and Debugging
  • Beckhoff AX8000 servo installation fuse selection
  • Beckhoff CP27xx Multi finger Touch PC Maintenance
  • Beckhoff CP69xx long-distance transmission and installation
  • Beckhoff CP60xx remote deployment and maintenance
  • Beckhoff CP72xx Installation and Maintenance Complete Manual
  • Beckhoff CP78xx Installation and Troubleshooting Guide
  • Beckhoff CP39xx Control Panel
  • Beckhoff CX8110 Embedded PC
  • Beckhoff CX50x0 series DIN rail embedded industrial PC
  • Beckhoff CP62xx panel PC
  • BECKHOFF C6030 Industrial Control Computer