Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS200VSVOH1B VME Servo Control Board
    ❤ Add to collection
  • GE IS200VSVOH1B VME Servo Control Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS200VSVOH1B VME Servo Control Board

    • ¥33315.00
      ¥33456.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.600KG
    • Quantity:
    • (Inventory: 36)
Description

GE IS200VSVOH1B VME Servo Control Board


GE IS200VSVOH1B VME Servo Control Board

Part Number IS200VSVOH1B Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI Function Module Availability In StockIS200VSVOH1B is a VME Servo Control Board manufactured by General Electric as part of the Mark VI Series used in gas turbine control systems. The four electro-hydraulic servo valves that operate the steam/fuel valves are under the direction of the Servo Control (VSVO) board. 

Typically, two servo terminal boards are used to separate these four channels (TSVO or DSVO). Using linear variable differential transformers, the valve position is determined (LVDT). The VSVO executes the loop control algorithm. On the front panel's J5 plug and the J3/J4 connectors on the VME rack, three cables connect to VSVO. TSVO delivers simplex signals, while the JR1, JS1, and JT1 connectors are used to fan out TMR signals. External trips from the protection module are plugged into JD1 or JD2. IS200VSVOH1B Installation Turn off the processor rack for the VME. Place the board in place and use your hands to press the top and bottom levers into the seat of the edge connectors. Tighten the captive screws on the front panel's top and bottom. Cable connections to the TSVO terminal boards are made at the lower J3 and J4 connectors on the VME rack. 

To secure the cables, they are latching connections. Start the VME rack and look at the diagnostic lights on the front panel. IS200VSVOH1B Operation LVDT position feedback, LVDT excitation, bidirectional servo current outputs, and pulse rate flows inputs are all included in VSVO's four channels. Up to six LVDT valve position inputs can be provided excitation for by the TSVO, which also accepts input from them. For each servo control loop, there is a choice of one, two, three, or four LVDTs. For applications measuring gas turbine flow, three inputs are offered. These signals pass through TSVO and are sent straight to J5 on the VSVO board front. When de-energized, each servo output has a dedicated suicide relay that, when controlled by firmware, shorts the VSVO output signal to signal common before returning to normal operation upon a manual reset instruction. 

Each servo's output voltage, current, and suicide relay are all monitored by diagnostics. Diagnostics Three LEDs at the top of the VSVO front panel display status data. The regular RUN state is flashing green, while FAIL is solid red. The third LED is STATUS, which is generally off but flashes a constant orange if the board has an alarm condition. The following diagnostic tests are included: The output servo current is excessive or not reacting, resulting in a fault. The regulator feedback (LVDT) signal has exceeded its limitations. When a problem occurs, the related regulator's poor sensor is removed from the feedback computation and the good sensor is used. The servo suicided. This results in a flaw. The A/D converter calibration voltage is out of range and is being utilized as a default value. 

The excitation voltage of the LVDT is out of range. A flaw is made. The difference between the input signal and the chosen value exceeds the TMR differential limit. This results in the creation of a fault indicating a problem with this sensor input. If any of the foregoing signals becomes unhealthy, a composite diagnostic alert, L#DIAG VSVO, is triggered. The toolbox contains information about the individual diagnoses. Individual diagnostic signals can be latched and reset with the RESET DIA signal if they become healthy. Terminal board connectors JR1, JS1, and JT1 each have their own ID device that is interrogated by the I/O board. The ID device is a read-only chip that contains the serial number, board type, revision number, and plug location of the terminal board. When VSVO reads the chip and detects a mismatch, a hardware incompatibility fault is generated. 

 Digital Servo Regulators The Digital Servo Regulators n = 1-4 splits the servo regulators into the software and hardware portions of the control loop. The user can select the servo feedback from the LVDT and pulse rate inputs. The LVDT input is a 3.2KHz sinusoidal signal, the magnitude of which is proportional to the position of the electromechanical valve controlled by the servo output. The pulse rate input is a TTL-type signal or some other periodic signal that activates a comparator input. An FPGA on the VSVO counts the comparator output transitions and converts them to a flow rate. For LVDT feedbacks, LVDT1 - 12 are scaled and conditioned in the Digital regulator's Position Feedback function, and can also be independently conditioned by a separate Monitoring function. 

The presence of an asterisk after a block name indicates the existence of a more detailed graphic to better define the block function. All VSVO signal space I/O is labeled as si for system input, which means the controller reads the signal space variable from the servo card, or so for system output, which means the controller writes the signal space variable to the servo card. Italic text is defined as a configuration parameter that the Toolbox can edit to redefine the VSVO's operation. Variable Name is an internal variable that the user cannot see using the Toolbox. Servo Suicide Control The Servo Suicide compares the absolute value of the filtered servo current error to the Sui Margin configuration parameter value. 

This detector determines whether the hardware servo current regulator has lost current control. If the current feedback does not match the current command, a diagnostic is generated, and the servo current output is disabled (disabled and put in a safe state). PulseRate /2 PulseRateMax The Digital Servo regulator is set up as a flow-rate controller. The feedback for the 1 PulseRate version of the flow-rate regulator is a pulse signal with a frequency proportional to the flow-rate of the liquid fuel. The bigger pulse rate frequency is chosen as the feedback for the flow rate regulator in the dual input instance. System Limit functions are given to monitor each of the pulse rate inputs and are enabled via the SysLimxEnabl configuration parameter.

 It can latch the signal space limit flags, SysLimxPR1 and/or SysLimxPR2, if desired.The Digital Servo regulator is set up as a flow-rate controller. The feedback for the 1 PulseRate version of the flow-rate regulator is a pulse signal with a frequency proportional to the flow-rate of the liquid fuel. The bigger pulse rate frequency is chosen as the feedback for the flow rate regulator in the dual input instance. System Limit functions are given to monitor each of the pulse rate inputs and are enabled via the SysLimxEnabl configuration parameter. It can latch the signal space limit flags, SysLimxPR1 and/or SysLimxPR2, if desired.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • DEIF TCM-2 thyristor control module: Wind power cut in control engineering guide
  • DEIF MVR-200 Medium Voltage Relay: Installation and Wiring Engineering Guide
  • DEIF MDR-2 Differential Relay: Engineering Guide for Generator Differential Protection
  • DEIF Delomatic 3 AOM: Engineering Guide for Analog Output Modules
  • DEIF AGI 400 Graphic Interface: Ship and Industrial HMI Solution
  • DEIF BRW-1 Marine Instruments: Installation and Calibration Guide for Offshore Bridge Indicators
  • DEIF AGC 200 Controller: Quick Deployment and Configuration Guide for Generator Sets
  • DEIF AGC-2 Controller: The Ultimate Guide to Automatic Control and Protection of Generator Sets
  • ABB SPA-ZC400 Gateway: REM54x Access to IEC 61850 Ultimate Engineering Guide
  • ABB REM 543/545 Terminal
  • Modular Architecture Analysis of DEIF PPU 300 Ship Generator Controller
  • DEIF DM-4 Marine&Offshore Ship Power Management System
  • Detailed Explanation of DEIF Delomatic Generator Control System Architecture
  • DEIF AGC-4 Mk II Generator Controller Depth Configuration Guide
  • DEIF AGC-4 Generator Controller Configuration and Debugging Guide
  • DEIF PPM Power Management System Operation and Troubleshooting
  • Installation and wiring of DEIF Multi line 2
  • Practical configuration and maintenance of Beckwith M-6280 capacitor bank controller
  • Beckwith M-3311 Transformer Protection Relay Setting and Engineering Application
  • Beckwith M-3311A Transformer Protection Relay Configuration and Optimization Guide
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit
  • Installation and I/O configuration of DEIF PPM-3 power management module
  • Beckwith M-3520 Interconnection Protection Relay
  • Beckwith M-3430 Generator Protection Relay
  • Beckwith M-2293B adapter panel replacement GE regulator guide
  • Selection and Networking of Beckwith M-2001C Digital Voltage Regulating Controller
  • Beckwith M-2001B Digital Voltage Regulating Controller
  • Beckwith M-0388/M-0389 Synchronous Inspection Relay Application Guide
  • Beckwith M-0193B Synchronizer Debugging and System Integration Guide
  • Beckwith M-0115A Parallel Balance Module Debugging Guide
  • Beckwith M-0067E On Load Voltage Regulating Controller Selection and Debugging Guide
  • Debugging and Fault Handling of Beckwith M-4272 Digital Busbar Conversion System
  • Beckwith M-3311A Transformer Protection Relay Debugging Guide
  • Beckwith M-3425A Generator Protection Relay Debugging Guide
  • Setting and troubleshooting of Basler BE1-27/59 voltage relay
  • Debugging and troubleshooting of Basler AVC63-12/AVC125-10 voltage regulator
  • Basler L301kc Line Array Camera Technology and Troubleshooting
  • Selection and Debugging of Basler CBS 212A Current Boosting System
  • Selection and commissioning of Basler BE3-25 synchronous inspection relay
  • Basler BE1-32R/32O/U Direction Power Relay Setting and Testing Guide
  • Basler PRS 250 Synchronous Relay Maintenance and Replacement Guide
  • Basler piA2400-17gc Industrial Camera Replacement and Optimization Guide
  • Basler BE1-11g Generator Protection System
  • Basler VR63-4C/UL Voltage Regulator
  • Basler BE1-DFPR feeder protection relay
  • Basler CBS 310/320 Current Boosting System
  • Basler UFOV 250A/260A protection module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F Regulator
  • Basler DECS-400 excitation system
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection
  • Basler SSR Static Voltage Regulator: A Complete Guide to Debugging and Troubleshooting
  • Basler SR4A/SR8A Voltage Regulator: Detailed Debugging and Troubleshooting Explanation
  • Basler BE2000E Voltage Regulator: Replacement and Application Details
  • Basler DECS-2100 Excitation System: Modular Upgrade and Engineering Application
  • Basler BE1-851 Overcurrent Protection System: A Complete Guide to Professional Debugging and Troubleshooting
  • Basler APR 63-5 Voltage Regulator: Professional Debugging and Troubleshooting Guide for Industrial Generator Excitation Systems
  • Basler BE1-FLEX Protection System: A Complete Guide to Professional Installation, Configuration, and Troubleshooting
  • Debugging and Testing of Basler BE1-700 Relay
  • Basler BE1-87B busbar differential setting test
  • Basler BE1-40Q demagnetization relay setting test
  • Basler BE1-60 Voltage Balance Relay Setting Test
  • Basler BE1-47N Relay Field Setting and Testing Guide
  • Basler BE1-81O/U Frequency Relay: On site Debugging and Protection Configuration Guide
  • Basler BE1-11f Feedline Protection System Debugging and Troubleshooting Guide
  • Basler DECS-250 Excitation System: Installation, Configuration, and Troubleshooting Practice Guide
  • Basler DECS-100 Digital Excitation System Debugging Guide
  • Application Guide for Basler BE1-BPR Circuit Breaker Protection Relay
  • Basler BE1-50/51B-255 Replacement CO Relay Guide
  • Basler BE1-25 synchronous inspection relay principle and testing
  • Basler BE1-51 Time Overcurrent Relay Debugging Guide
  • Practical Guide to Basler DECS-300 Digital Excitation System
  • Mitsubishi FX Series PLC Data Communication Practical Manual
  • Selection of Hirschmann cSCALE S6/C8 Mobile Safety Controller
  • Hirschmann OZD Profi G12D repeater explosion-proof installation configuration
  • Hirschmann OCTOPUS OS20/24 Switch Installation Power Supply
  • Hirschmann RS20/30/40 Switch Selection and PoE Deployment
  • Hirschmann EAGLE One Firewall Installation and Configuration Guide
  • Hirschmann MACH102 Switch Installation and Power Supply Guide
  • Hirschmann MICE MS20/MS30 Installation and DIP Configuration
  • Hirschmann BOBCAT BRS Switch Installation and Power Supply Guide
  • Hirschmann RSB20 Switch Deployment and Redundant Configuration
  • Hirschmann RS20 Basic Switch Installation and Debugging Guide
  • BECKHOFF EP20xx/EP28xx Output Module Installation and Debugging Guide
  • BECKHOFF EL5102 Encoder Terminal Debugging and Troubleshooting
  • BECKHOFF CU8803 Launch Box Installation and Explosion proof Guide
  • BECKHOFF CU20xx/CU22xx Switch Installation and Troubleshooting
  • BECKHOFF AMP8000 Servo Drive Installation and Debugging Manual
  • BECKHOFF EL2911 Safety Feed Terminal Debugging Guide
  • BECKHOFF EL600x/EL602x Serial Port Module Debugging Manual
  • BECKHOFF CP6700 Panel PC Installation and Maintenance Manual
  • BECKHOFF CP70xx panel maintenance and troubleshooting
  • BECKHOFF CP29xx Panel Installation and Troubleshooting
  • Beckhoff C6650-0060 Industrial Control Computer Hardware Architecture and RAID Data Security
  • Beckhoff BK1120/BK1250 EtherCAT Coupling Debugging and KL Terminal Parameterization Complete Guide
  • Beckhoff CX20x0 Embedded Controller Hardware Maintenance and Troubleshooting Complete Manual
  • Beckhoff CP77xx Panel PC Hardware Maintenance and Troubleshooting Complete Guide
  • Beckhoff EL41xx Analog Output Terminal Deep Analysis: Parameter Configuration, Fault Diagnosis, and Firmware Compatibility Guide
  • Beckhoff C63xx industrial computer power supply and shutdown configuration
  • Beckhoff C6920 Industrial Control Computer Selection and Expansion Guide
  • Beckhoff CU8800 USB extender diagnostic guide
  • Beckhoff AX2000 Shutdown Braking and Debugging
  • Beckhoff AX8000 servo installation fuse selection
  • Beckhoff CP27xx Multi finger Touch PC Maintenance
  • Beckhoff CP69xx long-distance transmission and installation
  • Beckhoff CP60xx remote deployment and maintenance
  • Beckhoff CP72xx Installation and Maintenance Complete Manual
  • Beckhoff CP78xx Installation and Troubleshooting Guide
  • Beckhoff CP39xx Control Panel
  • Beckhoff CX8110 Embedded PC
  • Beckhoff CX50x0 series DIN rail embedded industrial PC
  • Beckhoff CP62xx panel PC
  • BECKHOFF C6030 Industrial Control Computer
  • UniOP ePAD32B/ePAD33B/ePAD33BT Industrial HMI
  • UniOP ePAD05/06 Human Computer Interface
  • UniOP ePAD03/04 Human Computer Interface
  • UniOP BKDR-46-0045 Human Machine Interface
  • UniOP BKDR-16 human-machine interface
  • Beckwith M-3425A Relay Guide
  • Basler DECS-200-2L excitation system
  • Basler DECS-250 Excitation System Debugging Guide
  • HA-800A Servo Drive Debugging Guide
  • JUMO dTRANS p35 Manual