Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS210DDPTH1A Dynamic Pressure Transducer Terminal Board
    ❤ Add to collection
  • GE IS210DDPTH1A Dynamic Pressure Transducer Terminal Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS210DDPTH1A Dynamic Pressure Transducer Terminal Board

    • ¥13781.05
      ¥13352.02
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.580KG
    • Quantity:
    • (Inventory: 28)
Description

GE IS210DDPTH1A Dynamic Pressure Transducer Terminal Board


GE IS210DDPTH1A Dynamic Pressure Transducer Terminal Board

Part Number IS210DDPTH1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS210DDPTH1A is a Dynamic Pressure Transducer Terminal Board manufactured and designed by General Electric as part of the Mark VI Series used in GE distributed Gas Turbine Control Systems. The DDPT is a compact acoustic terminal board for DIN-rail mounting. 

The board accepts two pressure transducers for monitoring pressure waves in gas turbine combustion chambers, using either Vibro-meter or Bently-Nevada transducers. It connects to the I/O board with two cables and is designed to meet Class 1, Division 2 environmental requirements for hazardous gases. INSTALLATION: The DDPT board slides into a plastic holder, which mounts on the DIN rail. 

The pressure transducers are wired to the permanently mounted Euro-Block type terminal block, which has 42 terminals. Typically #18 AWG shielded twisted triplet wiring is used. There are ten screws for the SCOM (ground) connection. DDPT works with the VAMA I/O board. Cable connections from DDPT to the VAMA are made from JR1 to the J3 connector on the lower portion of the VME rack, and from JR5 to the J5 connector on the front panel of the VAMA. These are latching-type connectors to secure the cables. OPERATION: The I/O board supplies either positive 24 V dc or negative 24 V dc to the DDPT to power the pressure sensing equipment. 

The third-party vendor equipment supported are the Vibro-meter Galvanic Separation Unit Types GSI 1_ _, the Bently-Nevada 86517 with modifications 142533 or 159840 charge amplifier, or the Bently-Nevada dynamic pressure charge amplifier 350500. The Vibro-meter GSI setup conditions a pico-coulomb output from a dynamic pressure transducer (Vibro-meter CP216 or CP231) through a charge amplifier (Vibro-meter IPC 704) with a current output representing approximately 125 mA/psi. 

 The GSI unit provides an output ac signal (approx.  2 V peak) that represents the dynamic pressure (gain expressed in milli-volts/psi ) riding on top of a dc bias voltage of approximately +7 V dc. The GSI unit requires a +24 V dc power supply. Normally, the power supply return for the GSI will be grounded externally and the PCOM on the terminal board is not used. Only use PCOM when the external return ground is not used. The Bently-Nevada 86517 interface module converts the dynamic pressure transducer charge signal from pico-coulombs to milli-volts which represents the pressure in psi. The interface module output is comprised of an ac signal (approx.  1.2 V peak) riding on top of a negative dc bias voltage of approximately 0 V dc. The Bently-Nevada unit requires a -24 V dc power supply.

SPECIFICATIONS:

Part Number: IS210DDPTH1A
Manufacturer: General Electric
Series: Mark VI
Product Type: Dynamic Pressure Transducer Terminal Board
Number of trip solenoids: 3
Number of Transducers: 2
Common Mode Voltage Range: ±5 V
Size: 17.8 cm wide x 33.02 cm
Operating temperature: 0 to 60 °C
MPU Pulse Rate Range 2 Hz to 20 kHz
Repair: 3-7 Day
Availability: In Stock
Country of Origin: United States
Manual: GEH-6421H

FUNCTIONAL DESCRIPTION:

IS210DDPTH1A is a Dynamic Pressure Transducer Terminal Board manufactured and designed by General Electric as part of the Mark VI Series used in GE distributed Gas Turbine Control Systems. The DDPT is a compact acoustic terminal board for DIN-rail mounting. The board accepts two pressure transducers for monitoring pressure waves in gas turbine combustion chambers, using either Vibro-meter or Bently-Nevada transducers. It connects to the I/O board with two cables and is designed to meet Class 1, Division 2 environmental requirements for hazardous gases.

INSTALLATION:

The DDPT board slides into a plastic holder, which mounts on the DIN rail. The pressure transducers are wired to the permanently mounted Euro-Block type terminal block, which has 42 terminals. Typically #18 AWG shielded twisted triplet wiring is used. There are ten screws for the SCOM (ground) connection. DDPT works with the VAMA I/O board. Cable connections from DDPT to the VAMA are made from JR1 to the J3 connector on the lower portion of the VME rack, and from JR5 to the J5 connector on the front panel of the VAMA. These are latching-type connectors to secure the cables.

OPERATION:

The I/O board supplies either positive 24 V dc or negative 24 V dc to the DDPT to power the pressure sensing equipment. The third-party vendor equipment supported are the Vibro-meter Galvanic Separation Unit Types GSI 1_ _, the Bently-Nevada 86517 with modifications 142533 or 159840 charge amplifier, or the Bently-Nevada dynamic pressure charge amplifier 350500. The Vibro-meter GSI setup conditions a pico-coulomb output from a dynamic pressure transducer (Vibro-meter CP216 or CP231) through a charge amplifier (Vibro-meter IPC 704) with a current output representing approximately 125 mA/psi.

The GSI unit provides an output ac signal (approx. ± 2 V peak) that represents the dynamic pressure (gain expressed in milli-volts/psi ) riding on top of a dc bias voltage of approximately +7 V dc. The GSI unit requires a +24 V dc power supply. Normally, the power supply return for the GSI will be grounded externally and the PCOM on the terminal board is not used. Only use PCOM when the external return ground is not used. The Bently-Nevada 86517 interface module converts the dynamic pressure transducer charge signal from pico-coulombs to milli-volts which represents the pressure in psi. The interface module output is comprised of an ac signal (approx. ± 1.2 V peak) riding on top of a negative dc bias voltage of approximately –10 V dc. The Bently-Nevada unit requires a -24 V dc power supply.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ADLINK-PXIe-3988-3987-3977-3937-TL Controller Deployment and Maintenance Guide
  • ADLINK PXI-2020/2022 Synchronous Acquisition Card Configuration and Synchronization Guide
  • ADLINK DAQ/PXI-2000 series synchronous acquisition card configuration and triggering
  • ADLINK PXES-2788 series chassis deployment and maintenance
  • ADLINK PXES-2785 18 Slot Gen3 Chassis Deployment and Maintenance Guide
  • ADLINK PXES-2780 18 Slot PXIe Chassis Deployment Configuration
  • ADLINK PXES-2596 Gen3 Chassis Installation and Maintenance Guide
  • ADLINK PXES-2590 Chassis Deployment and System Management
  • ADLINK PXES-2314T Chassis Deployment and Troubleshooting Guide
  • ADLINK PXES-2301 Chassis Installation Monitoring and Troubleshooting
  • ADLINK PCIe-U300 Series USB3 Vision Acquisition Card Deployment Guide
  • ADLINK PCIe PXIe-8565 Expansion Kit Remote Control and Compatibility
  • Installation and troubleshooting of ADLINK PCIe GIE74V four channel PoE acquisition card
  • ADLINK PCIe GIE7x Poe+Acquisition Card Configuration and Triggering Troubleshooting
  • Advanced triggering and multi card synchronization of ADLINK PCIe-CPL64V image acquisition card
  • ADLINK PCIe-CPL64 Image Acquisition Card Hardware Trigger and Encoder Application
  • Application and troubleshooting of ADLINK PCIe-8560/PXI-8565 expansion kit
  • ADLINK PCIe 8332/PCIe 8334/PCIe 8338 EtherCAT Motion Controller Multi axis Synchronous Control
  • ADLINK PCIe-7432 32 channel isolated I/O card interrupt and driver
  • ADLINK PCIe-7256 Industrial I/O Card Interruption and Relay
  • ADLINK PCIe-833x EtherCAT Motion Controller Debugging and Maintenance
  • ADLINK PCIe-10GPoE 10GigE Visual Acquisition Card Practical Use
  • ADLINK PCI-8254/8258 Motion Controller Debugging and Maintenance
  • Application and Maintenance of ADLINK PCI-8158 Multi axis Motion Control Card
  • ADLINK PCI-8134A Maintenance and Troubleshooting Guide
  • ADLINK PCI-7250 Series Relay Output Card Configuration and Protection Circuit Guide
  • ADLINK PCI-6308 Series Isolated Analog Output Card Configuration and Programming
  • ADLINK PanKonix Series HMI Panel Selection and Deployment Guide
  • ADLINK NuDAM-6100 Series I/O Module Deployment and Protocol Optimization
  • Deployment and Calibration of ADLINK NuDAM-6000 Data Acquisition Module
  • ADLINK NEON-2000-Ono Intelligent Camera Deployment and Trigger Optimization
  • ADLINK NuDAM-65xx Communication Module Networking and Configuration Guide
  • ADLINK NuDAM-60xx Series Digital I/O Module Deployment and Watchdog Optimization
  • ADLINK MXE-5300 Fanless Industrial Control Computer Deployment and Troubleshooting Manual
  • ADLINK MXE-310 edge computing Platform Hardware Installation and BIOS Tuning
  • ADLINK MXE-230 series Alder Lake platform industrial computer deployment and maintenance manual
  • ADLINK MXE-210 Compact Fanless Industrial Control Computer Hardware Deployment and Debugging Guide
  • ADLINK MXC-3300/3340 Embedded Industrial Control Computer Hardware Integration and Debugging Manual
  • ADLINK MXA-312M Edge AI Platform Hardware Integration and Debugging Guide
  • ADLINK MXA-200 IoT Gateway Hardware Installation and Linux System Debugging Complete Guide
  • ADLINK MVP-6200 Industrial Control Computer: PCIe Gen4 and PCI Hybrid Expansion
  • ADLINK MVP-6100 Industrial Control Computer: PCI/PCIe Expansion and Robust Design
  • ADLINK MVP-5200 Industrial Control Computer: High Performance Multi Display and TSN Network
  • ADLINK MVP-5100 Fanless Industrial Control Computer Deployment and Development Guide
  • ADLINK MVP-3100 and MVP-3120 Embedded Systems
  • ADLINK MNET-J3/S23/MIA/DA2/SAN Single Axis Module Installation and Wiring Guide
  • ADLINK MNET-4XMO/C Motion Module Installation and Debugging Guide
  • ADLINK MCM-216/218 Edge DAQ Deployment Configuration Guide
  • ADLINK LPCIe-8124-C Encoder Card Trigger Configuration Guide
  • ADLINK IM/OM Series Industrial Display Installation and Debugging Guide
  • ADLINK GW-01 Industrial IoT Gateway Configuration and Debugging Guide
  • EURESYS Grablink Collection Card Selection and Trigger Configuration Guide
  • ADLINK Express HL Module Selection and Heat Dissipation Configuration Guide
  • ADLINK EOS-2000 Visual System Installation and Troubleshooting
  • ADLINK EOS-1200 Installation, Configuration, and Troubleshooting
  • Application and Configuration of ADLINK ECS-8582-4S Extension System
  • ADLINK DIN-814P-A4 Panasonic servo adapter board configuration
  • ADLINK DIN-814M-J3A Mitsubishi servo adapter board configuration
  • ADLINK DIN-814-GP Universal Adapter Board Configuration
  • Application and Configuration of ADLINK DIN-812M Adapter Board
  • Application and Configuration of ADLINK DIN-814Y Adapter Board
  • ADLINK DAQ/DAQE/PXI-250x waveform generation complete guide
  • ADLINK DAQ/DAQE/PXI-220x acquisition card fully configured
  • Application and Configuration of ADLINK cPCI-9116 Data Acquisition Card
  • ADLINK cPCI/PCI-8554/R: A Complete Guide from Architecture to Application
  • ADLINK cPCI-7432/7433/7434 isolated I/O card
  • ADLINK cPCI-3544/3534/3538 Serial Cardcard Configuration Practice
  • ADLINK cPCI-3534/3538/3544 Multi Serial Port Card Configuration Complete Solution
  • Complete Technical Guide for Euresys Coaxlink CXP Capture Card
  • ADLINK AMP-304C Advanced Motion Control Card Complete Guide
  • ADLINK AMP-104C Four Axis Motion Control Card
  • ADLINK NEON-1020/1040 Smart Camera
  • ADLINK USB-7230/7250 Isolation I/O Module Operation Manual
  • ADLINK SP-15W03 Intelligent Panel Integration and Configuration Manual
  • ADLINK AMP-20xC Interface Configuration and Wiring Guide
  • ADLINK 3488A GPIB Interface Card Selection Guide
  • Complete solution of ETEL TMB+torque motor selection parameters
  • ADLINK RTV series frame grabber deployment guide
  • ADLINK PCIe-FIW64/62 Image Acquisition Card Configuration Guide
  • ADLINK 6208/6216-GL Analog Output Card
  • ADLINK 723X Isolation I/O Card Configuration Guide
  • ADLINK PCI-9118 series high-speed DAQ card selection and DMA configuration
  • ADLINK PCI-9114 (A) Data Acquisition Card Selection and Configuration Guide
  • ADLINK PCI-7442/7443/7444 Isolation I/O Card Selection and Safety Configuration
  • ADLINK PCI-7250/7251 Relay Output Card Selection and Expansion Guide
  • Selection and Protection Configuration of Advantech PCI-1610CU Multi Serial Port Card
  • ADLINK NEON-1000-MDX Smart Camera Deployment and Trigger Configuration
  • ADLINK MXE-1300 Industrial Control Computer Selection and Deployment Guide
  • ADLINK MXE-200 Industrial Control Computer Deployment and BIOS Optimization Guide
  • ADLINK LPCIe-3488A GPIB Card Installation and Configuration Guide
  • Guidelines for Key Technologies of ETEL LMG/LMS Linear Motor Integration
  • ETEL IL+/LM Linear Motor Selection and Integration Guide
  • ETEL DSCDP/DSCDL/DSCDM Dual Axis Controller Debugging Guide
  • ETEL DSCDL Dual Axis Controller Hardware Integration Guide
  • ETEL DSB2P Series Servo Amplifier Connection and Configuration Guide
  • ETEL DSC2P/DSC2V Servo Controller Debugging Guide
  • DFI HD636-H81CS Industrial Motherboard Deployment and Debugging
  • Integration and Optimization of ADLINK DAQ-20xx Synchronous Acquisition Card
  • ADLINK cPCI-6530 Core i7 Blade Computer Deployment Guide
  • ADLINK cPCI-3610 Blade Computer Integration and Debugging
  • ADLINK AMP-204C/208C Troubleshooting Guide
  • ADLINK AmITX ALN Industrial Motherboard Characteristics and Application Analysis
  • ADLINK NuPRO-850 Motherboard Installation and Configuration Guide
  • ADLINK MI-965 Motherboard Installation and BIOS Configuration Guide
  • ADLINK M-302 Industrial Motherboard Installation and BIOS Optimization Guide
  • ADLINK PXI-3920/3910 Controller Installation and Configuration Guide
  • ADLINK PCI-8132 Motion Control Card Installation, Programming, and Debugging Guide
  • ADLINK cPCI-6760D/P7/P8 Module Installation and Hot Plug Guide
  • ADLINK ACL-7122 Digital I/O Card Installation and Programming
  • ADLINK NuPRO-775 Industrial Motherboard Installation and BIOS Configuration Detailed Explanation
  • ETEL Accuret MODULAR 300/400/600 Controller Selection Guide
  • Edwards CTI Kryogenics On Board 8F Enhanced Cryopump Explanation
  • ADLINK PCI-9112 Multi functional Data Acquisition Card
  • ADLINK PCI-8102 Two Axis Pulse Motion Control Card
  • ADLINK PCI-9812/10 high-speed synchronous acquisition card
  • ADLINK PCI-7200 High Speed Digital I/O Card
  • ADLINK MXE-1000 series fanless industrial computer
  • ADLINK IMB-T10 Mini ITX Embedded Motherboard
  • ADLINK HSL-DO32-M-N/P distributed I/O module
  • ADLINK DAQ-2500 Series Multi Channel Analog Output Card
  • ADLINK DAQ-2200 Series Data Acquisition Card
  • ADLINK ETX-AT-N270 Embedded Module
  • ADLINK ACL-7225B Relay Isolation Input Card Guide
  • ADLINK DAQ-2000 Synchronous Sampling and Acquisition Card Selection Guide
  • ADLINK NuPRO-E330 Industrial Motherboard Selection and Deployment
  • ADLINK ACL-8112 Data Acquisition Card Configuration and Programming
  • ADLINK USB-2405 Dynamic Signal Acquisition Module Deployment Guide
  • ADLINK PXIS-3320 PXI chassis installation troubleshooting