Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS210DDPTH1A Dynamic Pressure Transducer Terminal Board
    ❤ Add to collection
  • GE IS210DDPTH1A Dynamic Pressure Transducer Terminal Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS210DDPTH1A Dynamic Pressure Transducer Terminal Board

    • ¥13781.05
      ¥13352.02
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.580KG
    • Quantity:
    • (Inventory: 28)
Description

GE IS210DDPTH1A Dynamic Pressure Transducer Terminal Board


GE IS210DDPTH1A Dynamic Pressure Transducer Terminal Board

Part Number IS210DDPTH1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS210DDPTH1A is a Dynamic Pressure Transducer Terminal Board manufactured and designed by General Electric as part of the Mark VI Series used in GE distributed Gas Turbine Control Systems. The DDPT is a compact acoustic terminal board for DIN-rail mounting. 

The board accepts two pressure transducers for monitoring pressure waves in gas turbine combustion chambers, using either Vibro-meter or Bently-Nevada transducers. It connects to the I/O board with two cables and is designed to meet Class 1, Division 2 environmental requirements for hazardous gases. INSTALLATION: The DDPT board slides into a plastic holder, which mounts on the DIN rail. 

The pressure transducers are wired to the permanently mounted Euro-Block type terminal block, which has 42 terminals. Typically #18 AWG shielded twisted triplet wiring is used. There are ten screws for the SCOM (ground) connection. DDPT works with the VAMA I/O board. Cable connections from DDPT to the VAMA are made from JR1 to the J3 connector on the lower portion of the VME rack, and from JR5 to the J5 connector on the front panel of the VAMA. These are latching-type connectors to secure the cables. OPERATION: The I/O board supplies either positive 24 V dc or negative 24 V dc to the DDPT to power the pressure sensing equipment. 

The third-party vendor equipment supported are the Vibro-meter Galvanic Separation Unit Types GSI 1_ _, the Bently-Nevada 86517 with modifications 142533 or 159840 charge amplifier, or the Bently-Nevada dynamic pressure charge amplifier 350500. The Vibro-meter GSI setup conditions a pico-coulomb output from a dynamic pressure transducer (Vibro-meter CP216 or CP231) through a charge amplifier (Vibro-meter IPC 704) with a current output representing approximately 125 mA/psi. 

 The GSI unit provides an output ac signal (approx.  2 V peak) that represents the dynamic pressure (gain expressed in milli-volts/psi ) riding on top of a dc bias voltage of approximately +7 V dc. The GSI unit requires a +24 V dc power supply. Normally, the power supply return for the GSI will be grounded externally and the PCOM on the terminal board is not used. Only use PCOM when the external return ground is not used. The Bently-Nevada 86517 interface module converts the dynamic pressure transducer charge signal from pico-coulombs to milli-volts which represents the pressure in psi. The interface module output is comprised of an ac signal (approx.  1.2 V peak) riding on top of a negative dc bias voltage of approximately 0 V dc. The Bently-Nevada unit requires a -24 V dc power supply.

SPECIFICATIONS:

Part Number: IS210DDPTH1A
Manufacturer: General Electric
Series: Mark VI
Product Type: Dynamic Pressure Transducer Terminal Board
Number of trip solenoids: 3
Number of Transducers: 2
Common Mode Voltage Range: ±5 V
Size: 17.8 cm wide x 33.02 cm
Operating temperature: 0 to 60 °C
MPU Pulse Rate Range 2 Hz to 20 kHz
Repair: 3-7 Day
Availability: In Stock
Country of Origin: United States
Manual: GEH-6421H

FUNCTIONAL DESCRIPTION:

IS210DDPTH1A is a Dynamic Pressure Transducer Terminal Board manufactured and designed by General Electric as part of the Mark VI Series used in GE distributed Gas Turbine Control Systems. The DDPT is a compact acoustic terminal board for DIN-rail mounting. The board accepts two pressure transducers for monitoring pressure waves in gas turbine combustion chambers, using either Vibro-meter or Bently-Nevada transducers. It connects to the I/O board with two cables and is designed to meet Class 1, Division 2 environmental requirements for hazardous gases.

INSTALLATION:

The DDPT board slides into a plastic holder, which mounts on the DIN rail. The pressure transducers are wired to the permanently mounted Euro-Block type terminal block, which has 42 terminals. Typically #18 AWG shielded twisted triplet wiring is used. There are ten screws for the SCOM (ground) connection. DDPT works with the VAMA I/O board. Cable connections from DDPT to the VAMA are made from JR1 to the J3 connector on the lower portion of the VME rack, and from JR5 to the J5 connector on the front panel of the VAMA. These are latching-type connectors to secure the cables.

OPERATION:

The I/O board supplies either positive 24 V dc or negative 24 V dc to the DDPT to power the pressure sensing equipment. The third-party vendor equipment supported are the Vibro-meter Galvanic Separation Unit Types GSI 1_ _, the Bently-Nevada 86517 with modifications 142533 or 159840 charge amplifier, or the Bently-Nevada dynamic pressure charge amplifier 350500. The Vibro-meter GSI setup conditions a pico-coulomb output from a dynamic pressure transducer (Vibro-meter CP216 or CP231) through a charge amplifier (Vibro-meter IPC 704) with a current output representing approximately 125 mA/psi.

The GSI unit provides an output ac signal (approx. ± 2 V peak) that represents the dynamic pressure (gain expressed in milli-volts/psi ) riding on top of a dc bias voltage of approximately +7 V dc. The GSI unit requires a +24 V dc power supply. Normally, the power supply return for the GSI will be grounded externally and the PCOM on the terminal board is not used. Only use PCOM when the external return ground is not used. The Bently-Nevada 86517 interface module converts the dynamic pressure transducer charge signal from pico-coulombs to milli-volts which represents the pressure in psi. The interface module output is comprised of an ac signal (approx. ± 1.2 V peak) riding on top of a negative dc bias voltage of approximately –10 V dc. The Bently-Nevada unit requires a -24 V dc power supply.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications
  • Bonfiglioli 300 series reducer installation, maintenance, and troubleshooting guide
  • Selection and integration guide for Bonfiglioli R3 series planetary gearboxes in primary crushing equipment
  • Bonfiglioli C-series ATEX gearbox selection and explosion-proof application guide
  • Bonfiglioli Vectron EM-ENC-05 Full Function Expansion Module Integration Guide
  • Bonfiglioli Vectron EM-ENC-04 Multi functional Expansion Module Complete Configuration Guide
  • Bonfiglioli Vectron EM-ENC-03 Second Encoder Interface and System Bus Expansion Guide
  • Bonfiglioli Vectron EM-ENC-02 Expansion Module Integration and Encoder Interface Guide
  • Bonfiglioli Vectron CM-CAN CANopen Communication Configuration and DS402 Control Guide
  • Bonfiglioli Vectron EM-SYS System Bus Networking and Virtual Link Configuration Guide
  • Bonfiglioli Vectron CM-PDP Profibus DP Configuration and Debugging Guide
  • Bonfiglioli Vectron CM-232/485 Modbus Communication Configuration Guide
  • Bonfiglioli BMS series servo reduction motor selection and integration guide
  • Bonfiglioli ACTION 210/410 Inverter Debugging and Fault Diagnosis Complete Guide
  • Honeywell Enhanced Micro TDC 3000X System Redundancy Architecture and Maintenance Guide
  • Selection and Configuration of Bonfiglioli Active Series Inverter
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli HDP/HDO Series Heavy duty Gearboxes
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli 300/300M Series Gearboxes
  • Bonfiglioli 300M planetary gearbox selection and thermal verification guide
  • Bonfiglioli 3/H series heavy-duty gearbox selection and verification guide
  • Bonfiglioli KRG/KCG/KSD Hydraulic Coupling Selection and Integration Guide