  • GE IS210DDPTH1A Dynamic Pressure Transducer Terminal Board
    ❤ Add to collection
  • GE IS210DDPTH1A Dynamic Pressure Transducer Terminal Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS210DDPTH1A Dynamic Pressure Transducer Terminal Board

    • ¥13781.05
      ¥13352.02
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.580KG
    • Quantity:
    • (Inventory: 28)
Description

GE IS210DDPTH1A Dynamic Pressure Transducer Terminal Board


GE IS210DDPTH1A Dynamic Pressure Transducer Terminal Board

Part Number IS210DDPTH1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS210DDPTH1A is a Dynamic Pressure Transducer Terminal Board manufactured and designed by General Electric as part of the Mark VI Series used in GE distributed Gas Turbine Control Systems. The DDPT is a compact acoustic terminal board for DIN-rail mounting. 

The board accepts two pressure transducers for monitoring pressure waves in gas turbine combustion chambers, using either Vibro-meter or Bently-Nevada transducers. It connects to the I/O board with two cables and is designed to meet Class 1, Division 2 environmental requirements for hazardous gases. INSTALLATION: The DDPT board slides into a plastic holder, which mounts on the DIN rail. 

The pressure transducers are wired to the permanently mounted Euro-Block type terminal block, which has 42 terminals. Typically #18 AWG shielded twisted triplet wiring is used. There are ten screws for the SCOM (ground) connection. DDPT works with the VAMA I/O board. Cable connections from DDPT to the VAMA are made from JR1 to the J3 connector on the lower portion of the VME rack, and from JR5 to the J5 connector on the front panel of the VAMA. These are latching-type connectors to secure the cables. OPERATION: The I/O board supplies either positive 24 V dc or negative 24 V dc to the DDPT to power the pressure sensing equipment. 

The third-party vendor equipment supported are the Vibro-meter Galvanic Separation Unit Types GSI 1_ _, the Bently-Nevada 86517 with modifications 142533 or 159840 charge amplifier, or the Bently-Nevada dynamic pressure charge amplifier 350500. The Vibro-meter GSI setup conditions a pico-coulomb output from a dynamic pressure transducer (Vibro-meter CP216 or CP231) through a charge amplifier (Vibro-meter IPC 704) with a current output representing approximately 125 mA/psi. 

 The GSI unit provides an output ac signal (approx.  2 V peak) that represents the dynamic pressure (gain expressed in milli-volts/psi ) riding on top of a dc bias voltage of approximately +7 V dc. The GSI unit requires a +24 V dc power supply. Normally, the power supply return for the GSI will be grounded externally and the PCOM on the terminal board is not used. Only use PCOM when the external return ground is not used. The Bently-Nevada 86517 interface module converts the dynamic pressure transducer charge signal from pico-coulombs to milli-volts which represents the pressure in psi. The interface module output is comprised of an ac signal (approx.  1.2 V peak) riding on top of a negative dc bias voltage of approximately 0 V dc. The Bently-Nevada unit requires a -24 V dc power supply.

SPECIFICATIONS:

Part Number: IS210DDPTH1A
Manufacturer: General Electric
Series: Mark VI
Product Type: Dynamic Pressure Transducer Terminal Board
Number of trip solenoids: 3
Number of Transducers: 2
Common Mode Voltage Range: ±5 V
Size: 17.8 cm wide x 33.02 cm
Operating temperature: 0 to 60 °C
MPU Pulse Rate Range 2 Hz to 20 kHz
Repair: 3-7 Day
Availability: In Stock
Country of Origin: United States
Manual: GEH-6421H

FUNCTIONAL DESCRIPTION:

IS210DDPTH1A is a Dynamic Pressure Transducer Terminal Board manufactured and designed by General Electric as part of the Mark VI Series used in GE distributed Gas Turbine Control Systems. The DDPT is a compact acoustic terminal board for DIN-rail mounting. The board accepts two pressure transducers for monitoring pressure waves in gas turbine combustion chambers, using either Vibro-meter or Bently-Nevada transducers. It connects to the I/O board with two cables and is designed to meet Class 1, Division 2 environmental requirements for hazardous gases.

INSTALLATION:

The DDPT board slides into a plastic holder, which mounts on the DIN rail. The pressure transducers are wired to the permanently mounted Euro-Block type terminal block, which has 42 terminals. Typically #18 AWG shielded twisted triplet wiring is used. There are ten screws for the SCOM (ground) connection. DDPT works with the VAMA I/O board. Cable connections from DDPT to the VAMA are made from JR1 to the J3 connector on the lower portion of the VME rack, and from JR5 to the J5 connector on the front panel of the VAMA. These are latching-type connectors to secure the cables.

OPERATION:

The I/O board supplies either positive 24 V dc or negative 24 V dc to the DDPT to power the pressure sensing equipment. The third-party vendor equipment supported are the Vibro-meter Galvanic Separation Unit Types GSI 1_ _, the Bently-Nevada 86517 with modifications 142533 or 159840 charge amplifier, or the Bently-Nevada dynamic pressure charge amplifier 350500. The Vibro-meter GSI setup conditions a pico-coulomb output from a dynamic pressure transducer (Vibro-meter CP216 or CP231) through a charge amplifier (Vibro-meter IPC 704) with a current output representing approximately 125 mA/psi.

The GSI unit provides an output ac signal (approx. ± 2 V peak) that represents the dynamic pressure (gain expressed in milli-volts/psi ) riding on top of a dc bias voltage of approximately +7 V dc. The GSI unit requires a +24 V dc power supply. Normally, the power supply return for the GSI will be grounded externally and the PCOM on the terminal board is not used. Only use PCOM when the external return ground is not used. The Bently-Nevada 86517 interface module converts the dynamic pressure transducer charge signal from pico-coulombs to milli-volts which represents the pressure in psi. The interface module output is comprised of an ac signal (approx. ± 1.2 V peak) riding on top of a negative dc bias voltage of approximately –10 V dc. The Bently-Nevada unit requires a -24 V dc power supply.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Yokogawa AIP830 Single Circuit Operation Keyboard
  • Yokogawa RAMC flowmeter selection and troubleshooting
  • YASKAWA GA500 frequency converter troubleshooting
  • TRACO TIS600 power supply
  • Sigmatek ETV-0851 Control Panel Troubleshooting
  • Allen Bradley Quest AN-X2-AB-DHRIO Remote I/O Adapter Integration and Troubleshooting
  • Meggitt RPS6U power supply
  • Kongsberg RCU500 Controller Integration and Fault Diagnosis Guide
  • KBAC series frequency converter installation and fault diagnosis guide
  • EXOR effectiveness View eV058 series HMI industrial panel
  • Emerson OCR3000 Controller Troubleshooting Guide
  • Emerson Ovation OCR1100 Controller Maintenance and Troubleshooting
  • Elmo G-TUB30 Driver Troubleshooting Guide
  • Troubleshooting and Optimization of Basler A400 Series Camera
  • Troubleshooting and Maintenance of Automated Logic I/O Expansion Module
  • Troubleshooting and Maintenance of Aerotech UNIDEX 100 Controller
  • ADVANEST R6144 calibration source troubleshooting
  • Troubleshooting and Calibration of ABB Millmate Tension Gauge
  • ABB NGC8206 natural gas chromatograph troubleshooting and maintenance
  • ABB AO2040-CU Ex Explosion proof Analyzer Troubleshooting
  • ABB PFEA113 Tension Controller Troubleshooting Guide
  • ABB PFEA111/112/122 Tension Controller Troubleshooting Guide
  • ABB LS4000 laser analyzer
  • ABB SPAU 341 C Voltage Regulator Troubleshooting Guide
  • Analysis and Fault Diagnosis of ABB V-Contact VSC Medium Voltage Contactor
  • ABB UNITOL 1020 Compact Digital Excitation Regulator AVR Replacement and Troubleshooting
  • ABB UNITROL 1000 excitation system replacement and troubleshooting
  • ABB SYNC HROTACT 5 synchronization module troubleshooting and replacement
  • ABB SYNC HROTACT 5 Synchronization Device Replacement and Troubleshooting Guide
  • ABB Symphony Plus Module Replacement and Upgrade Guide
  • ABB S900 I/O Hazardous Area Deployment and Maintenance
  • ABB System 800xA Operations and Troubleshooting
  • ABB PCS6000 Troubleshooting and Module Replacement Guide
  • ABB PCS 8000 pumped storage excitation
  • ABB Procontrol P13 Bus Coupling Upgrade Guide
  • ABB NextMove ESB-2 Fault Diagnosis and Configuration Practice
  • ABB MEGADRIVE-LCI Maintenance and Selection Practice
  • ABB MEGADRIVE LCI Transmission Vibration Suppression
  • ABB MEGADRIVE LCI Water Cooling Troubleshooting and Maintenance Guide
  • Practical Maintenance and Common Troubleshooting of ABB DCS880
  • ABB SDCS-IOB-3 Replacement and Troubleshooting
  • ALSTOM MAE99-04 Serial Interface Terminal Panel Maintenance and Troubleshooting
  • Installation and Maintenance of ALSTOM ALSPA MV3000 Handheld Operator
  • Maintenance and commissioning of ABB KPM KB2 paper breakage detector
  • Maintenance and troubleshooting of ABB SCC-K converter
  • ABB SCC Gas Preprocessing System Maintenance and Selection Guide
  • ABB NGC8209 gas chromatograph maintenance
  • Maintenance and troubleshooting of ABB DCS DC speed controller
  • ABB ASTAT Crane Controller Maintenance and Debugging Guide
  • ABB ACS800 TIM foil IGBT
  • ABB LS25 laser analyzer troubleshooting
  • ABB REM54 motor terminal troubleshooting
  • ABB REL670 distance protection and troubleshooting
  • ABB SUE3000 switching device troubleshooting
  • ABB REF630 feeder protection
  • ABB REF620 (Relion 620 series) feeder protection and measurement device
  • ABB E1B-A Circuit Breaker
  • ABB FCU400-IR temperature measurement system troubleshooting
  • ABB TZIDC-200 locator configuration and troubleshooting
  • ABB DHH805-A Handheld Operator Configuration and Activation Guide
  • ABB SACO 16D1 alarm device replacement and troubleshooting
  • ABB 5SHY3545L0016 IGCT module replacement guide
  • ABB S600 I/O Module Replacement and Troubleshooting Guide
  • ABB NextMove e100 motion controller troubleshooting guide
  • Rockwell PowerFlex 700 Inverter Replacement and Troubleshooting Guide
  • Allen Bradley 1762-OW16 Output Module
  • Allen Bradley IntelliVAC 1503VC Series E Control Module
  • Allen‑Bradley IntelliVAC ™ 1503VC contactor control module
  • Woodward SOGAV 250 solenoid valve drives gas intake valve for troubleshooting
  • Woodward easyYgen-3500XT-P1 obstacle removal
  • Woodward CPC-II electro-hydraulic current pressure converter
  • UniOP ePALM10 Handheld HMI
  • TMEIC TMdrive-30 frequency converter
  • TEWS TVME200 Carrier Board Configuration and Troubleshooting Guide
  • TDK Alpha 400 Power Troubleshooting Guide
  • STUCKE SYMAP relay
  • Deployment and troubleshooting of Softing CAN-AC2-PCI interface card
  • Installation, Maintenance, and Troubleshooting of Siemens C7-623/624
  • Foxboro Compact 200 Series 16 Slot Bottom Plate Deployment and Maintenance Guide
  • Foxboro 84F/84W Vortex Flow Meter Selection and Debugging Guide
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller
  • DATA PATTERNS DP-VME-5114 Dual PMC Carrier Board Integration and Troubleshooting
  • CMZ SVM1608 Intelligent Servo Driver
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide
  • SUMITOMO ELECTRIC AC1135U Small Parts Turning Application Guide
  • SUMITOMO ELECTRIC AC1030U Precision Machining Selection and Practice for Small Parts
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection
  • BENDER RCMA475LY Residual Current Monitoring
  • BENDER IRDH575 Insulation Monitoring
  • BENDER IRDH265 Insulation Monitoring and Debugging
  • Bender RCMA475LY residual current monitor debugging
  • Beckwith Electric M-3425A Generator Protection Relay Debugging Guide