Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS210DDPTH1A Dynamic Pressure Transducer Terminal Board
    ❤ Add to collection
  • GE IS210DDPTH1A Dynamic Pressure Transducer Terminal Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS210DDPTH1A Dynamic Pressure Transducer Terminal Board

    • ¥13781.05
      ¥13352.02
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.580KG
    • Quantity:
    • (Inventory: 28)
Description

GE IS210DDPTH1A Dynamic Pressure Transducer Terminal Board


GE IS210DDPTH1A Dynamic Pressure Transducer Terminal Board

Part Number IS210DDPTH1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS210DDPTH1A is a Dynamic Pressure Transducer Terminal Board manufactured and designed by General Electric as part of the Mark VI Series used in GE distributed Gas Turbine Control Systems. The DDPT is a compact acoustic terminal board for DIN-rail mounting. 

The board accepts two pressure transducers for monitoring pressure waves in gas turbine combustion chambers, using either Vibro-meter or Bently-Nevada transducers. It connects to the I/O board with two cables and is designed to meet Class 1, Division 2 environmental requirements for hazardous gases. INSTALLATION: The DDPT board slides into a plastic holder, which mounts on the DIN rail. 

The pressure transducers are wired to the permanently mounted Euro-Block type terminal block, which has 42 terminals. Typically #18 AWG shielded twisted triplet wiring is used. There are ten screws for the SCOM (ground) connection. DDPT works with the VAMA I/O board. Cable connections from DDPT to the VAMA are made from JR1 to the J3 connector on the lower portion of the VME rack, and from JR5 to the J5 connector on the front panel of the VAMA. These are latching-type connectors to secure the cables. OPERATION: The I/O board supplies either positive 24 V dc or negative 24 V dc to the DDPT to power the pressure sensing equipment. 

The third-party vendor equipment supported are the Vibro-meter Galvanic Separation Unit Types GSI 1_ _, the Bently-Nevada 86517 with modifications 142533 or 159840 charge amplifier, or the Bently-Nevada dynamic pressure charge amplifier 350500. The Vibro-meter GSI setup conditions a pico-coulomb output from a dynamic pressure transducer (Vibro-meter CP216 or CP231) through a charge amplifier (Vibro-meter IPC 704) with a current output representing approximately 125 mA/psi. 

 The GSI unit provides an output ac signal (approx.  2 V peak) that represents the dynamic pressure (gain expressed in milli-volts/psi ) riding on top of a dc bias voltage of approximately +7 V dc. The GSI unit requires a +24 V dc power supply. Normally, the power supply return for the GSI will be grounded externally and the PCOM on the terminal board is not used. Only use PCOM when the external return ground is not used. The Bently-Nevada 86517 interface module converts the dynamic pressure transducer charge signal from pico-coulombs to milli-volts which represents the pressure in psi. The interface module output is comprised of an ac signal (approx.  1.2 V peak) riding on top of a negative dc bias voltage of approximately 0 V dc. The Bently-Nevada unit requires a -24 V dc power supply.

SPECIFICATIONS:

Part Number: IS210DDPTH1A
Manufacturer: General Electric
Series: Mark VI
Product Type: Dynamic Pressure Transducer Terminal Board
Number of trip solenoids: 3
Number of Transducers: 2
Common Mode Voltage Range: ±5 V
Size: 17.8 cm wide x 33.02 cm
Operating temperature: 0 to 60 °C
MPU Pulse Rate Range 2 Hz to 20 kHz
Repair: 3-7 Day
Availability: In Stock
Country of Origin: United States
Manual: GEH-6421H

FUNCTIONAL DESCRIPTION:

IS210DDPTH1A is a Dynamic Pressure Transducer Terminal Board manufactured and designed by General Electric as part of the Mark VI Series used in GE distributed Gas Turbine Control Systems. The DDPT is a compact acoustic terminal board for DIN-rail mounting. The board accepts two pressure transducers for monitoring pressure waves in gas turbine combustion chambers, using either Vibro-meter or Bently-Nevada transducers. It connects to the I/O board with two cables and is designed to meet Class 1, Division 2 environmental requirements for hazardous gases.

INSTALLATION:

The DDPT board slides into a plastic holder, which mounts on the DIN rail. The pressure transducers are wired to the permanently mounted Euro-Block type terminal block, which has 42 terminals. Typically #18 AWG shielded twisted triplet wiring is used. There are ten screws for the SCOM (ground) connection. DDPT works with the VAMA I/O board. Cable connections from DDPT to the VAMA are made from JR1 to the J3 connector on the lower portion of the VME rack, and from JR5 to the J5 connector on the front panel of the VAMA. These are latching-type connectors to secure the cables.

OPERATION:

The I/O board supplies either positive 24 V dc or negative 24 V dc to the DDPT to power the pressure sensing equipment. The third-party vendor equipment supported are the Vibro-meter Galvanic Separation Unit Types GSI 1_ _, the Bently-Nevada 86517 with modifications 142533 or 159840 charge amplifier, or the Bently-Nevada dynamic pressure charge amplifier 350500. The Vibro-meter GSI setup conditions a pico-coulomb output from a dynamic pressure transducer (Vibro-meter CP216 or CP231) through a charge amplifier (Vibro-meter IPC 704) with a current output representing approximately 125 mA/psi.

The GSI unit provides an output ac signal (approx. ± 2 V peak) that represents the dynamic pressure (gain expressed in milli-volts/psi ) riding on top of a dc bias voltage of approximately +7 V dc. The GSI unit requires a +24 V dc power supply. Normally, the power supply return for the GSI will be grounded externally and the PCOM on the terminal board is not used. Only use PCOM when the external return ground is not used. The Bently-Nevada 86517 interface module converts the dynamic pressure transducer charge signal from pico-coulombs to milli-volts which represents the pressure in psi. The interface module output is comprised of an ac signal (approx. ± 1.2 V peak) riding on top of a negative dc bias voltage of approximately –10 V dc. The Bently-Nevada unit requires a -24 V dc power supply.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit
  • Installation and I/O configuration of DEIF PPM-3 power management module
  • Beckwith M-3520 Interconnection Protection Relay
  • Beckwith M-3430 Generator Protection Relay
  • Beckwith M-2293B adapter panel replacement GE regulator guide
  • Selection and Networking of Beckwith M-2001C Digital Voltage Regulating Controller
  • Beckwith M-2001B Digital Voltage Regulating Controller
  • Beckwith M-0388/M-0389 Synchronous Inspection Relay Application Guide
  • Beckwith M-0193B Synchronizer Debugging and System Integration Guide
  • Beckwith M-0115A Parallel Balance Module Debugging Guide
  • Beckwith M-0067E On Load Voltage Regulating Controller Selection and Debugging Guide
  • Debugging and Fault Handling of Beckwith M-4272 Digital Busbar Conversion System
  • Beckwith M-3311A Transformer Protection Relay Debugging Guide
  • Beckwith M-3425A Generator Protection Relay Debugging Guide
  • Setting and troubleshooting of Basler BE1-27/59 voltage relay
  • Debugging and troubleshooting of Basler AVC63-12/AVC125-10 voltage regulator
  • Basler L301kc Line Array Camera Technology and Troubleshooting
  • Selection and Debugging of Basler CBS 212A Current Boosting System
  • Selection and commissioning of Basler BE3-25 synchronous inspection relay
  • Basler BE1-32R/32O/U Direction Power Relay Setting and Testing Guide
  • Basler PRS 250 Synchronous Relay Maintenance and Replacement Guide
  • Basler piA2400-17gc Industrial Camera Replacement and Optimization Guide
  • Basler BE1-11g Generator Protection System
  • Basler VR63-4C/UL Voltage Regulator
  • Basler BE1-DFPR feeder protection relay
  • Basler CBS 310/320 Current Boosting System
  • Basler UFOV 250A/260A protection module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F Regulator
  • Basler DECS-400 excitation system
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection
  • Basler SSR Static Voltage Regulator: A Complete Guide to Debugging and Troubleshooting
  • Basler SR4A/SR8A Voltage Regulator: Detailed Debugging and Troubleshooting Explanation
  • Basler BE2000E Voltage Regulator: Replacement and Application Details
  • Basler DECS-2100 Excitation System: Modular Upgrade and Engineering Application
  • Basler BE1-851 Overcurrent Protection System: A Complete Guide to Professional Debugging and Troubleshooting
  • Basler APR 63-5 Voltage Regulator: Professional Debugging and Troubleshooting Guide for Industrial Generator Excitation Systems
  • Basler BE1-FLEX Protection System: A Complete Guide to Professional Installation, Configuration, and Troubleshooting
  • Debugging and Testing of Basler BE1-700 Relay
  • Basler BE1-87B busbar differential setting test
  • Basler BE1-40Q demagnetization relay setting test
  • Basler BE1-60 Voltage Balance Relay Setting Test
  • Basler BE1-47N Relay Field Setting and Testing Guide
  • Basler BE1-81O/U Frequency Relay: On site Debugging and Protection Configuration Guide
  • Basler BE1-11f Feedline Protection System Debugging and Troubleshooting Guide
  • Basler DECS-250 Excitation System: Installation, Configuration, and Troubleshooting Practice Guide
  • Basler DECS-100 Digital Excitation System Debugging Guide
  • Application Guide for Basler BE1-BPR Circuit Breaker Protection Relay
  • Basler BE1-50/51B-255 Replacement CO Relay Guide
  • Basler BE1-25 synchronous inspection relay principle and testing
  • Basler BE1-51 Time Overcurrent Relay Debugging Guide
  • Practical Guide to Basler DECS-300 Digital Excitation System
  • Mitsubishi FX Series PLC Data Communication Practical Manual
  • Selection of Hirschmann cSCALE S6/C8 Mobile Safety Controller
  • Hirschmann OZD Profi G12D repeater explosion-proof installation configuration
  • Hirschmann OCTOPUS OS20/24 Switch Installation Power Supply
  • Hirschmann RS20/30/40 Switch Selection and PoE Deployment
  • Hirschmann EAGLE One Firewall Installation and Configuration Guide
  • Hirschmann MACH102 Switch Installation and Power Supply Guide
  • Hirschmann MICE MS20/MS30 Installation and DIP Configuration
  • Hirschmann BOBCAT BRS Switch Installation and Power Supply Guide
  • Hirschmann RSB20 Switch Deployment and Redundant Configuration
  • Hirschmann RS20 Basic Switch Installation and Debugging Guide
  • BECKHOFF EP20xx/EP28xx Output Module Installation and Debugging Guide
  • BECKHOFF EL5102 Encoder Terminal Debugging and Troubleshooting
  • BECKHOFF CU8803 Launch Box Installation and Explosion proof Guide
  • BECKHOFF CU20xx/CU22xx Switch Installation and Troubleshooting
  • BECKHOFF AMP8000 Servo Drive Installation and Debugging Manual
  • BECKHOFF EL2911 Safety Feed Terminal Debugging Guide
  • BECKHOFF EL600x/EL602x Serial Port Module Debugging Manual
  • BECKHOFF CP6700 Panel PC Installation and Maintenance Manual
  • BECKHOFF CP70xx panel maintenance and troubleshooting
  • BECKHOFF CP29xx Panel Installation and Troubleshooting
  • Beckhoff C6650-0060 Industrial Control Computer Hardware Architecture and RAID Data Security
  • Beckhoff BK1120/BK1250 EtherCAT Coupling Debugging and KL Terminal Parameterization Complete Guide
  • Beckhoff CX20x0 Embedded Controller Hardware Maintenance and Troubleshooting Complete Manual
  • Beckhoff CP77xx Panel PC Hardware Maintenance and Troubleshooting Complete Guide
  • Beckhoff EL41xx Analog Output Terminal Deep Analysis: Parameter Configuration, Fault Diagnosis, and Firmware Compatibility Guide
  • Beckhoff C63xx industrial computer power supply and shutdown configuration
  • Beckhoff C6920 Industrial Control Computer Selection and Expansion Guide
  • Beckhoff CU8800 USB extender diagnostic guide
  • Beckhoff AX2000 Shutdown Braking and Debugging
  • Beckhoff AX8000 servo installation fuse selection
  • Beckhoff CP27xx Multi finger Touch PC Maintenance
  • Beckhoff CP69xx long-distance transmission and installation
  • Beckhoff CP60xx remote deployment and maintenance
  • Beckhoff CP72xx Installation and Maintenance Complete Manual
  • Beckhoff CP78xx Installation and Troubleshooting Guide
  • Beckhoff CP39xx Control Panel
  • Beckhoff CX8110 Embedded PC
  • Beckhoff CX50x0 series DIN rail embedded industrial PC
  • Beckhoff CP62xx panel PC
  • BECKHOFF C6030 Industrial Control Computer
  • UniOP ePAD32B/ePAD33B/ePAD33BT Industrial HMI
  • UniOP ePAD05/06 Human Computer Interface
  • UniOP ePAD03/04 Human Computer Interface
  • UniOP BKDR-46-0045 Human Machine Interface
  • UniOP BKDR-16 human-machine interface
  • Beckwith M-3425A Relay Guide
  • Basler DECS-200-2L excitation system
  • Basler DECS-250 Excitation System Debugging Guide
  • HA-800A Servo Drive Debugging Guide
  • JUMO dTRANS p35 Manual
  • KEBA XE020 RFID Module Manual
  • Honeywell SmartLine Transmitter Complete Guide
  • Eaton CROUSE-HINDS Series MA30 Lightning Protection Filter Installation Guide
  • BECKHOFF EL31xx Series 16 Bit EtherCAT Analog Input Terminal Manual
  • BECKHOFF AX5000 Servo Drive Maintenance Guide
  • BECKHOFF EL30xx Analog Input Diagnostic Guide
  • BECKHOFF EL70x7 Stepper Terminal Maintenance Guide
  • BECKHOFF CX52x0 Industrial Control Computer Maintenance Guide
  • BECKHOFF CX9000/CX9010 Hardware Maintenance Guide
  • BECKHOFF AM8xxx Motor Guide
  • BECKHOFF EL9xxx System Terminal Guide
  • Beckhoff EK110x/EK15xx Coupling Guide
  • BECKHOFF CX51x0 Embedded PC Deployment Guide
  • BECKHOFF CX2100-0014 Power Module Guide
  • BECKHOFF CX1000 Industrial Control PC Complete Manual
  • BECKHOFF CP69xx Panel Installation and Troubleshooting
  • Beckhoff C6030-0080 Industrial Control PC Guide
  • IFM O3D300 3D Sensor Debugging and Troubleshooting Guide
  • Allen Bradley Guardmaster 440R Safety Relay Troubleshooting and Configuration Guide
  • OMRON CS1 PLC System Maintenance and Troubleshooting Guide