Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS210DSVOH1B Servo Terminal Board
    ❤ Add to collection
  • GE IS210DSVOH1B Servo Terminal Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS210DSVOH1B Servo Terminal Board

    • ¥10557.02
      ¥14532.02
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:4.550KG
    • Quantity:
    • (Inventory: 58)
Description

GE IS210DSVOH1B Servo Terminal Board


GE IS210DSVOH1B Servo Terminal Board

Part Number IS210DSVOH1B Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS210DSVOH1B is a Servo Terminal Board developed by GE. It is part of Mark VI control system. The board represents a compact and versatile servo terminal board specifically engineered for DIN-rail mounting, catering to diverse industrial applications. 

Offering a range of features and capabilities, the board stands as a cornerstone component within servo control systems, facilitating precise positioning and flow measurement functionalities. KEY FEATURES Two servo outputs enable precise control over servo mechanisms, ensuring accurate and responsive motion control. Input/output (I/O) interfaces for six LVDT (Linear Variable Differential Transformer) position sensors provide precise position feedback, enhancing control accuracy and system performance. Two active pulse rate inputs cater to flow measurement applications, providing real-time data acquisition for fluid dynamics analysis and control. Jumper-selectable servo coil currents ranging from 10 to 120 mA offer flexibility in adapting to various servo motor specifications and operational requirements. 

 PRODUCT ATTRIBUTES Connection and Compatibility: Seamless integration with the VSVO processor board is facilitated through a standardized 37-pin cable interface, ensuring compatibility with existing system configurations. This cable interface aligns with those utilized on larger TSVO boards, streamlining installation and maintenance procedures. Versatile Mounting Options: The board's compact design allows for efficient utilization of space, with the flexibility to stack terminal boards vertically on DIN-rails. This space-saving configuration optimizes cabinet space usage, ensuring efficient layout and organization within industrial control systems. Scalability and Configuration Options: For applications requiring expanded functionality, it supports the connection of multiple boards to the VSVO processor board, accommodating diverse system requirements. 

However, it's important to note that only the simplex version is currently available, providing streamlined functionality tailored to specific application needs. With its compact design, comprehensive features, and seamless compatibility with VSVO processor boards, it offers unparalleled performance and flexibility in industrial automation environments. Whether used for precise motion control or flow measurement tasks, the board stands as a trusted component for enhancing operational efficiency and system reliability. INSTALLATION Mounting the Holder: The board is first inserted into a plastic holder specifically designed for DIN-rail mounting. This holder securely mounts onto the DIN-rail, providing stability and ease of access for installation and maintenance tasks. 

Wiring Servo I/O: The servo input/output (I/O) connections are wired directly to the Euro-Block type terminal block affixed to the board. Depending on the specific model variant, the terminal block may feature either 36 terminals (DSVOH1A) or 42 terminals (DSVOH1B, H2B). Typically, #18 AWG shielded twisted pair wiring is used for these connections, ensuring reliable signal transmission and minimizing electromagnetic interference. 

Ground Connection: Grounding is crucial for maintaining signal integrity and electrical safety within the system. The board features six screws dedicated to the SCOM (ground) connection. It's essential to ensure that these ground connections are made with the shortest distance possible to minimize the risk of interference and optimize system performance. FAULT DETECTION Servo Current Out of Limits or Not Responding: Check servo motor connections and ensure they are securely connected to the board. 

Verify servo coil current settings using jumper configurations and ensure they align with the motor specifications. Monitor servo output signals and compare them with expected values to identify abnormalities. Inspect the servo motor for mechanical issues or binding that may impede its movement. Conduct a functional test to validate servo motor operation under load conditions. Excitation Out of Range: / Verify power supply connections to the board and ensure adequate voltage levels are maintained. Check wiring connections to the sensors and ensure they are securely terminated. Measure excitation voltage levels at the terminals and compare them with specified values. Inspect sensor cables for damage or wear that may affect signal integrity. 

Calibrate sensors as per manufacturer recommendations to ensure accurate position feedback. LVDT Feedback Out of Limits: Monitor feedback signals and compare them with expected position values. Verify wiring connections and ensure proper termination to the board. Check for mechanical obstructions or misalignments affecting sensor performance. Inspect signal conditioning circuits and ensure they are functioning correctly. Recalibrate sensors and adjust signal processing parameters as needed. Failed ID Chip: Verify ID chip connections and ensure they are securely seated on the board. 

Check for physical damage or corrosion on the ID chip and surrounding components. Replace the ID chip with a compatible spare to determine if the fault persists. Inspect communication interfaces and connectors for damage or contamination. Reset the board and restart the system to re-establish communication.

Product Attributes

Connection and Compatibility: Seamless integration with the VSVO processor board is facilitated through a standardized 37-pin cable interface, ensuring compatibility with existing system configurations. This cable interface aligns with those utilized on larger TSVO boards, streamlining installation and maintenance procedures.

Versatile Mounting Options: The board's compact design allows for efficient utilization of space, with the flexibility to stack terminal boards vertically on DIN-rails. This space-saving configuration optimizes cabinet space usage, ensuring efficient layout and organization within industrial control systems.

Scalability and Configuration Options: For applications requiring expanded functionality, it supports the connection of multiple boards to the VSVO processor board, accommodating diverse system requirements. However, it's important to note that only the simplex version is currently available, providing streamlined functionality tailored to specific application needs.

With its compact design, comprehensive features, and seamless compatibility with VSVO processor boards, it offers unparalleled performance and flexibility in industrial automation environments. Whether used for precise motion control or flow measurement tasks, the board stands as a trusted component for enhancing operational efficiency and system reliability.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Modular Architecture Analysis of DEIF PPU 300 Ship Generator Controller
  • DEIF DM-4 Marine&Offshore Ship Power Management System
  • Detailed Explanation of DEIF Delomatic Generator Control System Architecture
  • DEIF AGC-4 Mk II Generator Controller Depth Configuration Guide
  • DEIF AGC-4 Generator Controller Configuration and Debugging Guide
  • DEIF PPM Power Management System Operation and Troubleshooting
  • Installation and wiring of DEIF Multi line 2
  • Practical configuration and maintenance of Beckwith M-6280 capacitor bank controller
  • Beckwith M-3311 Transformer Protection Relay Setting and Engineering Application
  • Beckwith M-3311A Transformer Protection Relay Configuration and Optimization Guide
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit
  • Installation and I/O configuration of DEIF PPM-3 power management module
  • Beckwith M-3520 Interconnection Protection Relay
  • Beckwith M-3430 Generator Protection Relay
  • Beckwith M-2293B adapter panel replacement GE regulator guide
  • Selection and Networking of Beckwith M-2001C Digital Voltage Regulating Controller
  • Beckwith M-2001B Digital Voltage Regulating Controller
  • Beckwith M-0388/M-0389 Synchronous Inspection Relay Application Guide
  • Beckwith M-0193B Synchronizer Debugging and System Integration Guide
  • Beckwith M-0115A Parallel Balance Module Debugging Guide
  • Beckwith M-0067E On Load Voltage Regulating Controller Selection and Debugging Guide
  • Debugging and Fault Handling of Beckwith M-4272 Digital Busbar Conversion System
  • Beckwith M-3311A Transformer Protection Relay Debugging Guide
  • Beckwith M-3425A Generator Protection Relay Debugging Guide
  • Setting and troubleshooting of Basler BE1-27/59 voltage relay
  • Debugging and troubleshooting of Basler AVC63-12/AVC125-10 voltage regulator
  • Basler L301kc Line Array Camera Technology and Troubleshooting
  • Selection and Debugging of Basler CBS 212A Current Boosting System
  • Selection and commissioning of Basler BE3-25 synchronous inspection relay
  • Basler BE1-32R/32O/U Direction Power Relay Setting and Testing Guide
  • Basler PRS 250 Synchronous Relay Maintenance and Replacement Guide
  • Basler piA2400-17gc Industrial Camera Replacement and Optimization Guide
  • Basler BE1-11g Generator Protection System
  • Basler VR63-4C/UL Voltage Regulator
  • Basler BE1-DFPR feeder protection relay
  • Basler CBS 310/320 Current Boosting System
  • Basler UFOV 250A/260A protection module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F Regulator
  • Basler DECS-400 excitation system
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection
  • Basler SSR Static Voltage Regulator: A Complete Guide to Debugging and Troubleshooting
  • Basler SR4A/SR8A Voltage Regulator: Detailed Debugging and Troubleshooting Explanation
  • Basler BE2000E Voltage Regulator: Replacement and Application Details
  • Basler DECS-2100 Excitation System: Modular Upgrade and Engineering Application
  • Basler BE1-851 Overcurrent Protection System: A Complete Guide to Professional Debugging and Troubleshooting
  • Basler APR 63-5 Voltage Regulator: Professional Debugging and Troubleshooting Guide for Industrial Generator Excitation Systems
  • Basler BE1-FLEX Protection System: A Complete Guide to Professional Installation, Configuration, and Troubleshooting
  • Debugging and Testing of Basler BE1-700 Relay
  • Basler BE1-87B busbar differential setting test
  • Basler BE1-40Q demagnetization relay setting test
  • Basler BE1-60 Voltage Balance Relay Setting Test
  • Basler BE1-47N Relay Field Setting and Testing Guide
  • Basler BE1-81O/U Frequency Relay: On site Debugging and Protection Configuration Guide
  • Basler BE1-11f Feedline Protection System Debugging and Troubleshooting Guide
  • Basler DECS-250 Excitation System: Installation, Configuration, and Troubleshooting Practice Guide
  • Basler DECS-100 Digital Excitation System Debugging Guide
  • Application Guide for Basler BE1-BPR Circuit Breaker Protection Relay
  • Basler BE1-50/51B-255 Replacement CO Relay Guide
  • Basler BE1-25 synchronous inspection relay principle and testing
  • Basler BE1-51 Time Overcurrent Relay Debugging Guide
  • Practical Guide to Basler DECS-300 Digital Excitation System
  • Mitsubishi FX Series PLC Data Communication Practical Manual
  • Selection of Hirschmann cSCALE S6/C8 Mobile Safety Controller
  • Hirschmann OZD Profi G12D repeater explosion-proof installation configuration
  • Hirschmann OCTOPUS OS20/24 Switch Installation Power Supply
  • Hirschmann RS20/30/40 Switch Selection and PoE Deployment
  • Hirschmann EAGLE One Firewall Installation and Configuration Guide
  • Hirschmann MACH102 Switch Installation and Power Supply Guide
  • Hirschmann MICE MS20/MS30 Installation and DIP Configuration
  • Hirschmann BOBCAT BRS Switch Installation and Power Supply Guide
  • Hirschmann RSB20 Switch Deployment and Redundant Configuration
  • Hirschmann RS20 Basic Switch Installation and Debugging Guide
  • BECKHOFF EP20xx/EP28xx Output Module Installation and Debugging Guide
  • BECKHOFF EL5102 Encoder Terminal Debugging and Troubleshooting
  • BECKHOFF CU8803 Launch Box Installation and Explosion proof Guide
  • BECKHOFF CU20xx/CU22xx Switch Installation and Troubleshooting
  • BECKHOFF AMP8000 Servo Drive Installation and Debugging Manual
  • BECKHOFF EL2911 Safety Feed Terminal Debugging Guide
  • BECKHOFF EL600x/EL602x Serial Port Module Debugging Manual
  • BECKHOFF CP6700 Panel PC Installation and Maintenance Manual
  • BECKHOFF CP70xx panel maintenance and troubleshooting
  • BECKHOFF CP29xx Panel Installation and Troubleshooting
  • Beckhoff C6650-0060 Industrial Control Computer Hardware Architecture and RAID Data Security
  • Beckhoff BK1120/BK1250 EtherCAT Coupling Debugging and KL Terminal Parameterization Complete Guide
  • Beckhoff CX20x0 Embedded Controller Hardware Maintenance and Troubleshooting Complete Manual
  • Beckhoff CP77xx Panel PC Hardware Maintenance and Troubleshooting Complete Guide
  • Beckhoff EL41xx Analog Output Terminal Deep Analysis: Parameter Configuration, Fault Diagnosis, and Firmware Compatibility Guide
  • Beckhoff C63xx industrial computer power supply and shutdown configuration
  • Beckhoff C6920 Industrial Control Computer Selection and Expansion Guide
  • Beckhoff CU8800 USB extender diagnostic guide
  • Beckhoff AX2000 Shutdown Braking and Debugging
  • Beckhoff AX8000 servo installation fuse selection
  • Beckhoff CP27xx Multi finger Touch PC Maintenance
  • Beckhoff CP69xx long-distance transmission and installation
  • Beckhoff CP60xx remote deployment and maintenance
  • Beckhoff CP72xx Installation and Maintenance Complete Manual
  • Beckhoff CP78xx Installation and Troubleshooting Guide
  • Beckhoff CP39xx Control Panel
  • Beckhoff CX8110 Embedded PC
  • Beckhoff CX50x0 series DIN rail embedded industrial PC
  • Beckhoff CP62xx panel PC
  • BECKHOFF C6030 Industrial Control Computer
  • UniOP ePAD32B/ePAD33B/ePAD33BT Industrial HMI
  • UniOP ePAD05/06 Human Computer Interface
  • UniOP ePAD03/04 Human Computer Interface
  • UniOP BKDR-46-0045 Human Machine Interface
  • UniOP BKDR-16 human-machine interface
  • Beckwith M-3425A Relay Guide
  • Basler DECS-200-2L excitation system
  • Basler DECS-250 Excitation System Debugging Guide
  • HA-800A Servo Drive Debugging Guide
  • JUMO dTRANS p35 Manual
  • KEBA XE020 RFID Module Manual
  • Honeywell SmartLine Transmitter Complete Guide
  • Eaton CROUSE-HINDS Series MA30 Lightning Protection Filter Installation Guide
  • BECKHOFF EL31xx Series 16 Bit EtherCAT Analog Input Terminal Manual
  • BECKHOFF AX5000 Servo Drive Maintenance Guide
  • BECKHOFF EL30xx Analog Input Diagnostic Guide
  • BECKHOFF EL70x7 Stepper Terminal Maintenance Guide
  • BECKHOFF CX52x0 Industrial Control Computer Maintenance Guide
  • BECKHOFF CX9000/CX9010 Hardware Maintenance Guide
  • BECKHOFF AM8xxx Motor Guide