Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS210TREAS1A - AERO TRIP TB/W DBRD
    ❤ Add to collection
  • GE IS210TREAS1A - AERO TRIP TB/W DBRD

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    IS210TREAS1A - AERO TRIP TB/W DBRD
    • ¥12000.00
      ¥24520.00
      ¥12000.00
      ¥12000.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.500KG
    • Quantity:
    • (Inventory: 33)
Description
IS210TREAS1A - AERO TRIP TB/W DBRD

GE IS210TREAS1A - AERO TRIP TB/W DBRD

Part Number IS210TREAS1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI Function Module Availability In StockIS210TREAS1A is an Aero Derivative Turbine Emergency Trip Board manufactured and designed by General Electric as part of the Mark VIe Series used in distributed control systems. As a component of the Mark* VIe system, the Aero derivative Turbine Emergency Trip (TREA) terminal board and WREA option card work with PPRA turbine I/O packs. 

The following are the inputs and outputs: Two 24-point pluggable barrier terminal blocks (H1A or S1A) or 48 pluggable Euro-style box terminals are used as customer input terminals (H3A or S3A). Six fanned passive pulse rate sensors that sense a toothed wheel to determine the turbine speed (up to three shafts with two sensors each). To trip the system, three solid-state output contacts with TMR votes of TREAH1A, H3A plus WREAH1A or TREAS1A, S3A plus WREAS1A must be 24 V dc. Four voltage detecting circuits for 24-125 V dc voltage for trip string monitoring. 

Four extra hardware or conditional trip inputs are provided via four 24 V dc WREAH1A or WREAS1A contact inputs. On WREA, wetting power is supplied via the JH1 connector. Using an RS-232 or RS-422 transmitter, one-speed repeater output for each of the six-speed inputs duplicates the speed pulse rate signals. INSTALLATION: The WREA should by default be mounted to the TREA terminal board when it is received from the factory. Use the steps below to replace the WREA if the board needs to be taken out to service the TREA fanning jumpers. Align the WREA's two connectors with the TREA's two connectors. 

When viewing the WREA, the row of configuration jumpers at the bottom of the board is regarded as the end. After the two boards are in line, firmly press on the four screw heads that surround the connector to secure it. Voltage detection, trip contact inputs, and relay outputs are connected to the I/O terminal blocks TB1 for the H1 and S1 board variations. TB2 is wired with passive pulse rate pick-up devices. Each block has 24 terminals that may accommodate wires up to #12 AWG and are secured with two screws. Each terminal block is followed by a shield termination strip connected to the chassis ground. 

Voltage detection, trip contact inputs, and relay outputs are attached to the I/O box terminals at the top of the board for the H3 and S3 board variations. The lower terminals are coupled with passive pulse rate pick-ups. Each terminal accepts a single #12 AWG wire and plugs it into a header on the TREA board. OPERATION: Three PPRA I/O packs placed directly on the TREA board are intended to be used with it. A self-contained emergency trip function is therefore formed by the TREA/WREA/PPRA assembly. Only three PPRA I/O packets are necessary for TREAH1A, S1A, H3A, and S3A plus WREA to operate properly. Operation with a single or twin pack is not feasible. In systems with a single controller, the controller R network, S network, and T network should be linked to the PPRA on the JX1 connection, JY1 connector, and JZ1 connector, respectively. Keep in mind that one controller is the source of all three networks. The R network of the controller should be connected to the PPRA on the JX1 connector, the S network to the PPRA on the JY1 connector, and both the R and S networks to the PPRA on the JZ1 connector in systems with dual controllers. 

CONFIGURATION: The fanning of the X channel speed inputs to the Y and Z PPRA I/O packs is selected by jumpers JP1 and JP2. These jumpers are required for TREA and WREA operations with PPRA. The six-speed repeater output circuits' output behavior is configured using the WREA jumpers JP1 through JP12. RS-232 signal level (the default) and RS-485 signal level can be chosen for the repeater output using the jumpers JP1 through JP6. While JP4?JP6 configure repeaters for PR4?PR6, JP1?JP3 configure the repeater outputs for PR1?PR3. When used with PPRA, jumpers JP7 through JP12 should stay in the PR1 through PR6 positions by default.Module manufactured by General Electric as part of the Mark VI/VIe Series used in gas turbine sppedtronic control systems

Product Features

High performance: adopting high-performance microprocessor and advanced control algorithm, it can realise fast and accurate control and monitoring, and improve production efficiency and product quality.

Modular design: It is convenient for users to configure and expand, which improves the flexibility and maintainability of the system.

Easy Integration: Provide standard communication interface and protocol, which is convenient for users to integrate with other equipments and achieve seamless connection.

High reliability: Made of high-quality materials and advanced technology, it has high reliability and stability, and can operate stably under harsh working environment.

Easy to use: Provides simple interface and easy-to-operate software, which is convenient for users to install and use. At the same time, the module also has a self-diagnostic function, which can help users quickly locate faults and maintenance.

Good scalability: can be seamlessly integrated with other ABB modules and equipment, which is convenient for users to build a large-scale automation control system.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice