  • GE IS220PPROS1B - SIL IO PACK, PROTECTION, BPPC BASED
    ❤ Add to collection
  • GE IS220PPROS1B - SIL IO PACK, PROTECTION, BPPC BASED

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    IS220PPROS1B - SIL IO PACK, PROTECTION, BPPC BASED
    • ¥12000.00
      ¥24520.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.600KG
    • Quantity:
    • (Inventory: 33)
Description
IS220PPROS1B - SIL IO PACK, PROTECTION, BPPC BASED

GE IS220PPROS1B - SIL IO PACK, PROTECTION, BPPC BASED

Part Number IS220PPROS1B Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VIe Function Module Availability In StockIS220PPROS1B is an Emergency Turbine Protection I/O Pack manufactured and designed by General Electric as part of the Mark VIe Series used in GE Distributed Control Systems. A backup Overspeed protection system with a backup check for generator synchronization to a utility bus is provided by the Emergency Turbine Protection I/O pack (PPRO) and related terminal boards. They also serve as the primary control's independent watchdog. 

Three triple modular redundant (TMR) PPRO I/O packs mounted to a separate simplex protection (SPRO) terminal board make up a typical protection system. Each SPRO is connected to the designated emergency trip board by a cable with DC-37 pin connections on both ends: TREG: Gas Turbine Emergency Trip Terminal Board. TREL: Large Steam Turbine Emergency Trip Terminal Board. TRES: Small/Medium Steam Turbine Emergency Trip Terminal Board. TREA: Turbine Emergency Trip Terminal Board. A single-board TMR protection system using three PPRO I/O packs is possible in a different configuration. The PPRO connects to the control modules via Ethernet for IONet communications. The primary and backup trip systems for the Mark* VIe control are integrated at the trip terminal board level. The Turbine Primary I/O pack, PTUR, which uses a primary trip board, provides primary protection (TRPG, TRPL, TRPS, TRPA). The PPRO I/O pack operates a backup trip board to provide backup protection (TREG, TREL, TRES, TREA). PPRO can handle three different types of speed signals, including hardware-implemented Overspeed, acceleration, deceleration, and basic Overspeed. 

The pack keeps an eye on the primary control's performance and can check the primary speed to make sure everything is running normally. Through a broad range of feedback signals, PPRO keeps track of the status and functionality of the chosen trip board. PPRO will trip the backup trip relays on the trip board and initiate a trip on the primary control if a fault is found. The principal control action has no bearing on the pack and is completely independent of it. COMPATIBILITY: Direct mounting on SPRO or TREA is supported by PPROH1A. It is cable-compatible with TREG, TREL, and TRES when placed on SPRO. 

 SIMPLE MAIN CONTROL: The Mark VIe trip board TRES supports simplex backup protection. The controller IONet has one PPRO network port. All Mark VIe backup trip boards, TREG, TREL, TREA, and TRES, feature TMR backup protection. In this setup, the controller IONet is connected to one port on each of the three PPRO I/O packs. DUAL MAIN CONTROL: The Mark VIe trip board TRES supports simplex backup protection. The R controller is connected to the network first when this setup is used. The S controller is accessible via the second network connection. Then, PPRO is in charge of overseeing the performance of both controllers. The pack trips if either controller fails, or both controllers fail, according to PPRO. 

 INSTALLATION: The Mark VIe SPRO or TREA terminal board accepts the PPRO's direct mounting. Cables with DC-37 pin connections on both ends are necessary between the SPRO board and the chosen trip terminal board when placed on an SPRO board. The following are the installation steps: Install the SPRO or TREA terminal board firmly. If SPRO is used, mount the chosen trip terminal board. If TREA is not utilized, connect a cable with DC-37 pin connections on both ends between SPRO and the chosen trip terminal board. Directly connect three PPRO modules to TREA or one PPRO module to each SPRO. PPRO's threaded posts, which are situated on either side of the Ethernet ports, should be slid into the openings in the mounting bracket for the terminal board. To ensure a tight fit between the PPRO's DC-62 pin connector and the terminal board, adjust the bracket's position. 

Secure the mounting bracket firmly. Only one adjustment should be necessary during the lifespan of the product. Lock PPRO in place by firmly tightening the nuts on the threaded posts. Depending on the setup of the machine, connect either one or two Ethernet wires. The PPRO module chooses the appropriate operation over either port and is not sensitive to Ethernet connections. Connect the module's power connector, which is located on its side, to power it up. The I/O module has a built-in soft-start feature that regulates current levels when used. To customize the module as needed, use the ToolboxST* program. OPERATION: The I/O pack or module function-specific acquisition board is connected to the processor board. 

The soft-start circuit ramps up the voltage available on the processor board when input power is applied. The processor reset is turned off and the local power supply is turned on in order. After finishing self-test routines, the processor loads application code from flash memory that is particular to the I/O pack or module type. To verify that the application code, acquisition board, and terminal board are correctly matched, the application code reads the board ID information. When there is a good match, the processor makes an effort to start Ethernet connections by asking for a network address. The whole circuitry required to enable the I/O pack to function from one or two Ethernet inputs is contained in the processor application code. 

Both network pathways are constantly active when two Ethernet inputs are used. The I/O pack or module operation will not be hampered by a failure of either network, and the functioning network connection will reveal the failure. Compared to a traditional hot-backup system, where the second port is only used when the primary port fails to function, this configuration is more fault tolerant. The processor's Ethernet ports automatically negotiate between half-duplex and full-duplex operation at speeds between 10 MB/s and 100 MB/s. Each Mark VIe Ethernet I/O pack or module shares a processing board. It has the following in it: A fast CPU with flash memory and RAM. Two connectorized, totally independent 10/100 Ethernet ports. A hardware reset circuit and watchdog timer. A temperature sensor inside. LEDs that display status. The capacity to read IDs on other boards through electronic means. An input power connector with a current limiter and a soft start. Local power supplies, with monitoring and sequencing.Module manufactured by General Electric as part of the Mark VI/VIe Series used in gas turbine sppedtronic control systems

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ADLINK NuPRO-E320 motherboard deployment and tuning guide
  • ADLINK NuPRO-800 Dual PIII Industrial SBC Maintenance and Upgrade Guide
  • ADLINK NuPRO-598 SBC Maintenance Practical Guide
  • ADLINK MXC-6300 Fanless Embedded Industrial Control Computer Deployment Guide
  • ADLINK Express-BASE7 Carrier Board Quick Deployment and Debugging Guide
  • ADLINK DLAP-211 Edge AI Platform Selection and Deployment Guide
  • ADLINK 7230 Series Isolation DIO Card Selection and Engineering Application Guide
  • ADLINK cPCI-6965 SBC Embedded Installation and BIOS Tuning Guide
  • ADLINK 7200 Series High Speed DIO Card Practical Guide
  • ADLINK DLAP Series Edge AI Acceleration Platform Selection and Deployment Practical Guide
  • DEIF TCM-2 thyristor control module: Wind power cut in control engineering guide
  • DEIF MVR-200 Medium Voltage Relay: Installation and Wiring Engineering Guide
  • DEIF MDR-2 Differential Relay: Engineering Guide for Generator Differential Protection
  • DEIF Delomatic 3 AOM: Engineering Guide for Analog Output Modules
  • DEIF AGI 400 Graphic Interface: Ship and Industrial HMI Solution
  • DEIF BRW-1 Marine Instruments: Installation and Calibration Guide for Offshore Bridge Indicators
  • DEIF AGC 200 Controller: Quick Deployment and Configuration Guide for Generator Sets
  • DEIF AGC-2 Controller: The Ultimate Guide to Automatic Control and Protection of Generator Sets
  • ABB SPA-ZC400 Gateway: REM54x Access to IEC 61850 Ultimate Engineering Guide
  • ABB REM 543/545 Terminal
  • Modular Architecture Analysis of DEIF PPU 300 Ship Generator Controller
  • DEIF DM-4 Marine&Offshore Ship Power Management System
  • Detailed Explanation of DEIF Delomatic Generator Control System Architecture
  • DEIF AGC-4 Mk II Generator Controller Depth Configuration Guide
  • DEIF AGC-4 Generator Controller Configuration and Debugging Guide
  • DEIF PPM Power Management System Operation and Troubleshooting
  • Installation and wiring of DEIF Multi line 2
  • Practical configuration and maintenance of Beckwith M-6280 capacitor bank controller
  • Beckwith M-3311 Transformer Protection Relay Setting and Engineering Application
  • Beckwith M-3311A Transformer Protection Relay Configuration and Optimization Guide
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit
  • Installation and I/O configuration of DEIF PPM-3 power management module
  • Beckwith M-3520 Interconnection Protection Relay
  • Beckwith M-3430 Generator Protection Relay
  • Beckwith M-2293B adapter panel replacement GE regulator guide
  • Selection and Networking of Beckwith M-2001C Digital Voltage Regulating Controller
  • Beckwith M-2001B Digital Voltage Regulating Controller
  • Beckwith M-0388/M-0389 Synchronous Inspection Relay Application Guide
  • Beckwith M-0193B Synchronizer Debugging and System Integration Guide
  • Beckwith M-0115A Parallel Balance Module Debugging Guide
  • Beckwith M-0067E On Load Voltage Regulating Controller Selection and Debugging Guide
  • Debugging and Fault Handling of Beckwith M-4272 Digital Busbar Conversion System
  • Beckwith M-3311A Transformer Protection Relay Debugging Guide
  • Beckwith M-3425A Generator Protection Relay Debugging Guide
  • Setting and troubleshooting of Basler BE1-27/59 voltage relay
  • Debugging and troubleshooting of Basler AVC63-12/AVC125-10 voltage regulator
  • Basler L301kc Line Array Camera Technology and Troubleshooting
  • Selection and Debugging of Basler CBS 212A Current Boosting System
  • Selection and commissioning of Basler BE3-25 synchronous inspection relay
  • Basler BE1-32R/32O/U Direction Power Relay Setting and Testing Guide
  • Basler PRS 250 Synchronous Relay Maintenance and Replacement Guide
  • Basler piA2400-17gc Industrial Camera Replacement and Optimization Guide
  • Basler BE1-11g Generator Protection System
  • Basler VR63-4C/UL Voltage Regulator
  • Basler BE1-DFPR feeder protection relay
  • Basler CBS 310/320 Current Boosting System
  • Basler UFOV 250A/260A protection module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F Regulator
  • Basler DECS-400 excitation system
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection
  • Basler SSR Static Voltage Regulator: A Complete Guide to Debugging and Troubleshooting
  • Basler SR4A/SR8A Voltage Regulator: Detailed Debugging and Troubleshooting Explanation
  • Basler BE2000E Voltage Regulator: Replacement and Application Details
  • Basler DECS-2100 Excitation System: Modular Upgrade and Engineering Application
  • Basler BE1-851 Overcurrent Protection System: A Complete Guide to Professional Debugging and Troubleshooting
  • Basler APR 63-5 Voltage Regulator: Professional Debugging and Troubleshooting Guide for Industrial Generator Excitation Systems
  • Basler BE1-FLEX Protection System: A Complete Guide to Professional Installation, Configuration, and Troubleshooting
  • Debugging and Testing of Basler BE1-700 Relay
  • Basler BE1-87B busbar differential setting test
  • Basler BE1-40Q demagnetization relay setting test
  • Basler BE1-60 Voltage Balance Relay Setting Test
  • Basler BE1-47N Relay Field Setting and Testing Guide
  • Basler BE1-81O/U Frequency Relay: On site Debugging and Protection Configuration Guide
  • Basler BE1-11f Feedline Protection System Debugging and Troubleshooting Guide
  • Basler DECS-250 Excitation System: Installation, Configuration, and Troubleshooting Practice Guide
  • Basler DECS-100 Digital Excitation System Debugging Guide
  • Application Guide for Basler BE1-BPR Circuit Breaker Protection Relay
  • Basler BE1-50/51B-255 Replacement CO Relay Guide
  • Basler BE1-25 synchronous inspection relay principle and testing
  • Basler BE1-51 Time Overcurrent Relay Debugging Guide
  • Practical Guide to Basler DECS-300 Digital Excitation System
  • Mitsubishi FX Series PLC Data Communication Practical Manual
  • Selection of Hirschmann cSCALE S6/C8 Mobile Safety Controller
  • Hirschmann OZD Profi G12D repeater explosion-proof installation configuration
  • Hirschmann OCTOPUS OS20/24 Switch Installation Power Supply
  • Hirschmann RS20/30/40 Switch Selection and PoE Deployment
  • Hirschmann EAGLE One Firewall Installation and Configuration Guide
  • Hirschmann MACH102 Switch Installation and Power Supply Guide
  • Hirschmann MICE MS20/MS30 Installation and DIP Configuration
  • Hirschmann BOBCAT BRS Switch Installation and Power Supply Guide
  • Hirschmann RSB20 Switch Deployment and Redundant Configuration
  • Hirschmann RS20 Basic Switch Installation and Debugging Guide
  • BECKHOFF EP20xx/EP28xx Output Module Installation and Debugging Guide
  • BECKHOFF EL5102 Encoder Terminal Debugging and Troubleshooting
  • BECKHOFF CU8803 Launch Box Installation and Explosion proof Guide
  • BECKHOFF CU20xx/CU22xx Switch Installation and Troubleshooting
  • BECKHOFF AMP8000 Servo Drive Installation and Debugging Manual
  • BECKHOFF EL2911 Safety Feed Terminal Debugging Guide
  • BECKHOFF EL600x/EL602x Serial Port Module Debugging Manual
  • BECKHOFF CP6700 Panel PC Installation and Maintenance Manual
  • BECKHOFF CP70xx panel maintenance and troubleshooting
  • BECKHOFF CP29xx Panel Installation and Troubleshooting
  • Beckhoff C6650-0060 Industrial Control Computer Hardware Architecture and RAID Data Security
  • Beckhoff BK1120/BK1250 EtherCAT Coupling Debugging and KL Terminal Parameterization Complete Guide
  • Beckhoff CX20x0 Embedded Controller Hardware Maintenance and Troubleshooting Complete Manual
  • Beckhoff CP77xx Panel PC Hardware Maintenance and Troubleshooting Complete Guide
  • Beckhoff EL41xx Analog Output Terminal Deep Analysis: Parameter Configuration, Fault Diagnosis, and Firmware Compatibility Guide
  • Beckhoff C63xx industrial computer power supply and shutdown configuration
  • Beckhoff C6920 Industrial Control Computer Selection and Expansion Guide
  • Beckhoff CU8800 USB extender diagnostic guide
  • Beckhoff AX2000 Shutdown Braking and Debugging
  • Beckhoff AX8000 servo installation fuse selection
  • Beckhoff CP27xx Multi finger Touch PC Maintenance
  • Beckhoff CP69xx long-distance transmission and installation
  • Beckhoff CP60xx remote deployment and maintenance
  • Beckhoff CP72xx Installation and Maintenance Complete Manual
  • Beckhoff CP78xx Installation and Troubleshooting Guide
  • Beckhoff CP39xx Control Panel
  • Beckhoff CX8110 Embedded PC
  • Beckhoff CX50x0 series DIN rail embedded industrial PC
  • Beckhoff CP62xx panel PC
  • BECKHOFF C6030 Industrial Control Computer