GE IS400JGPAG1A TERMINAL BOARD FOR PCCAH1A
GE IS400JGPAG1A TERMINAL BOARD FOR PCCAH1A
Part Number IS400JGPAG1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS400JGPAG1A is a Ground Terminal Board and it's a part of GE Speedtronic Mark VIe gas turbine control. The ground and power board (JGPA) is a long narrow board that mounts adjacent to PCAA where shield wires are terminated. JGPA provides shield wire terminal points that may be tied directly to the underlying functional earth sheet metal or wired to a preferred grounding point. In this respect, it is very similar to the JGND board offered as an option with other Mark VIe terminal boards.
Features
Single-Slot Module
SNP/SNP-X Protocol (master, slave)
CCM Protocol (master, slave, peer)
RTU Modbus Protocol (slave only)
Supports connection to MS-DOS or Windows
programming and configuration software package (monitor only)
12 Mhz, 80C186 Microprocessor
Two RS-422/RS-485 or RS-232 Serial Ports
CCM, RTU and SNP/SNP-X Available on Either or Both Ports
Simultaneous Communications on Both Ports (up to 9.6 Kbps, or 19.2 Kbps individually)
High Performance Access to PLC Memory
Three Status LEDs
Reset pushbutton
Soft Switch Configuration (no switches or jumpers)
No Battery Required
Ease of Use
• Simple and powerful instruction set
• One-axis or two-axis motion programs with synchronized block start
• Program support for a short motion program (called Program Zero) which can be created in the MS-DOS programming software configuration function
• Nonvolatile (flash) storage for 10 programs and 40 subroutines
• User scaling of programming units (in Standard mode only)
• Generic programming using command parameters as operands for Acceleration, Velocity, Move and Dwell commands
• Configured with MS-DOS configuration software
Instructions and warnings related to the operation of the product:
The following specifications must be strictly observed:
The technical specifications and typical applications of the product system must be strictly observed.
PERSONNEL TRAINING: Only trained personnel may install, operate, maintain or repair the product system. These personnel must be instructed on the
Hazardous area conditions must be instructed and explained to these personnel.
Unauthorised modifications: No modifications or structural changes may be made to the product system.
Maintenance Responsibility: It must be ensured that the product system is only used under appropriate conditions and in a condition that is fully fit for purpose.
Working environment: The user must fulfil the specified environmental conditions:
Safety regulations
The following safety regulations must be fully observed when (maintenance) work is carried out on the product system:
1 Disconnect completely.
2 Secure to prevent reconnection.
3 Confirm that the installation has been completed.
4 Perform grounding and short-circuiting.
email:1583694102@qq.com