  • NI 183893D-01 FieldPoint Terminal Base
    ❤ Add to collection
  • NI 183893D-01 FieldPoint Terminal Base

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    NI 183893D-01 FieldPoint Terminal Base

    • ¥12000.00
      ¥24520.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.600KG
    • Quantity:
    • (Inventory: 33)
Description

NI 183893D-01 FieldPoint Terminal Base


NI 183893D-01 FieldPoint Terminal Base

Characteristics

Analogue Input: 16 single-ended or 8 differential analogue input channels with 16-bit resolution and a maximum sampling rate of 500 kS/s, which can meet a variety of high-precision data acquisition needs, and can be widely used to collect analogue signals from various types of sensors, such as temperature, pressure, displacement and other sensor signals.

Analogue Output: Equipped with 2 analogue output channels, with the same 16-bit resolution and a maximum update rate of 900 kS/s, low output impedance and over-drive protection, it can achieve precise analogue signal control of external devices, such as controlling the speed of motors and the opening degree of valves.

Digital I/O: With 24 digital I/O lines, 8 of which are 1MHz hardware timer lines, these digital I/O lines can be flexibly configured as inputs or outputs, which can be easily interacted with external digital devices to acquire and control digital signals, such as monitoring the status of switches and controlling relays.

Counter/Timer: Four 32-bit counters/timers are integrated to perform a wide range of measurement tasks such as edge counting, pulse width measurement, quadrature encoding, etc. They also provide a rich selection of input routing options and can be synchronised with external signals, which provides strong support for applications requiring precise timing and counting functions, such as applications in measuring rotational speed and frequency.

Technical Advantages

NI-STC3 Timing and Synchronisation Technology: The device adopts NI-STC3 Timing and Synchronisation Technology, with independent analogue and digital timing engines and retriggerable measurement tasks, which enables precise timing and synchronisation control, ensures the accuracy and reliability of data acquisition and processing, and effectively improves the overall performance of the system.

Hi-Speed USB Interface: Connected to a computer via a USB 2.0 high-speed or full-speed compatible interface, it enables fast data transmission and ensures efficient communication between the device and the host computer, facilitating real-time data acquisition and control.

Physical Specifications

Dimensions: The screw terminal version measures approximately 10.4 x 6.8 x 1.4 inches and the BNC version measures approximately 8.0 x 7.3 x 2.7 inches.

Weight: The screw terminal version weighs approximately 3 lbs 1.6 oz and the BNC version weighs approximately 3 lbs 5.6 oz.

Areas of Application

Industrial automation: can be used to monitor and control a variety of parameters and equipment in the industrial production process, such as automated production lines in the temperature, pressure, flow and other parameters of the collection, as well as motors, valves, conveyor belts, and other equipment control, to achieve the automation of the production process and intelligent.

Test and Measurement: Applicable to various test and measurement scenarios, such as performance testing of electronic equipment, calibration testing of sensors, mechanical vibration testing, etc., which can accurately collect and record test data to provide a reliable basis for product development and quality control.

Laboratory research: In scientific research and laboratory environment, it can be used to collect experimental data, such as signal acquisition in physics experiments, data monitoring in chemistry experiments, etc., to help researchers conduct data analysis and verification of experimental results.

Data recording and monitoring: It can be used as a data recording device to record various data in a long-term and stable manner, which can be used for monitoring the operation status of the equipment and troubleshooting, discovering potential problems in time and guaranteeing the normal operation of the equipment.

Applications

Industrial Automation and Process - Control

In industrial - automation applications, the NI 183893D - 01 FieldPoint Terminal Base is used to build distributed - control systems. It can connect modules to monitor and control industrial processes such as temperature - regulation in a chemical - processing plant, pressure - control in a manufacturing - process pipeline, and flow - rate - measurement in a water - treatment facility. The ability to distribute power and communicate with other systems makes it an ideal component for these types of applications.

Building - Automation and Facility - Management

In building - automation systems, the terminal base can be used to connect modules for controlling building - services such as heating, ventilation, air - conditioning (HVAC), lighting, and access - control systems. For example, it can interface with temperature - sensors and humidity - sensors to adjust the HVAC - system operation and with digital - input - modules to monitor the status of doors and windows for security - access - control purposes.

Remote - Monitoring and Data - Acquisition

The FieldPoint Terminal Base is well - suited for remote - monitoring applications. It can be deployed in remote locations to collect data from sensors and transmit it back to a central - monitoring station. This is useful in applications such as environmental - monitoring (e.g., weather - station data - collection), energy - - production - monitoring (e.g., solar - panel - output - measurement), and infrastructure - monitoring (e.g., bridge - - vibration - monitoring).


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications
  • Bonfiglioli 300 series reducer installation, maintenance, and troubleshooting guide
  • Selection and integration guide for Bonfiglioli R3 series planetary gearboxes in primary crushing equipment
  • Bonfiglioli C-series ATEX gearbox selection and explosion-proof application guide
  • Bonfiglioli Vectron EM-ENC-05 Full Function Expansion Module Integration Guide
  • Bonfiglioli Vectron EM-ENC-04 Multi functional Expansion Module Complete Configuration Guide
  • Bonfiglioli Vectron EM-ENC-03 Second Encoder Interface and System Bus Expansion Guide
  • Bonfiglioli Vectron EM-ENC-02 Expansion Module Integration and Encoder Interface Guide
  • Bonfiglioli Vectron CM-CAN CANopen Communication Configuration and DS402 Control Guide
  • Bonfiglioli Vectron EM-SYS System Bus Networking and Virtual Link Configuration Guide
  • Bonfiglioli Vectron CM-PDP Profibus DP Configuration and Debugging Guide
  • Bonfiglioli Vectron CM-232/485 Modbus Communication Configuration Guide
  • Bonfiglioli BMS series servo reduction motor selection and integration guide
  • Bonfiglioli ACTION 210/410 Inverter Debugging and Fault Diagnosis Complete Guide
  • Honeywell Enhanced Micro TDC 3000X System Redundancy Architecture and Maintenance Guide
  • Selection and Configuration of Bonfiglioli Active Series Inverter
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli HDP/HDO Series Heavy duty Gearboxes
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli 300/300M Series Gearboxes
  • Bonfiglioli 300M planetary gearbox selection and thermal verification guide
  • Bonfiglioli 3/H series heavy-duty gearbox selection and verification guide
  • Bonfiglioli KRG/KCG/KSD Hydraulic Coupling Selection and Integration Guide