  • ABB NIAI02 Analog Input Termination Module
    ❤ Add to collection
  • ABB NIAI02 Analog Input Termination Module

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    NIAI02 Analog Input Termination Module
    • ¥6583.00
      ¥9699.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.000KG
    • Quantity:
    • (Inventory: 2)
Description
NIAI02 Analog Input Termination Module

ABB NIAI02 Analog Input Termination Module

Functional Features

Signal Adaptation and Acquisition: It can adapt a variety of common analog signal types, such as 4-20mA current signals, 0-10V or ±10V voltage signals, etc., and can be connected to various types of sensors, such as temperature sensors, pressure sensors, flow sensors, etc., to achieve the measurement of a variety of physical quantities in the industrial field and data acquisition.

Signal Conditioning and Conversion: Condition the input analog signals, including filtering, amplification, linearization and other processing to improve the quality and stability of the signal to ensure that the subsequent system can accurately carry out data processing and control. At the same time, the analog signal is converted into a digital signal to facilitate communication and interaction with the digital part of the control system.

Channel Independence: Multiple input channels are independent of each other, and each channel can be configured and used separately without interfering with each other, which facilitates separate processing and monitoring of different analog signals, and improves the flexibility and expandability of the system.

Fault diagnosis and alarm: Built-in fault diagnosis function can real-time monitor the working status of the module itself as well as the abnormal conditions of the input signals, such as signal open-circuit, short-circuit, over-range, etc., and can promptly send out an alarm signal to notify the operator to deal with the situation, which can help to improve the reliability and safety of the system.

Technical Parameters

Number of input channels: Generally there are 8 or 16 analog input channels, which can meet the requirements of industrial applications of different scales, and users can choose the appropriate number of channels according to actual needs.

Signal input range: Support a variety of standard analog signal input ranges, such as 4-20mA, 0-10V, -10V to +10V, etc., and can also be customized according to the needs of special applications, in order to adapt to the output signal range of different sensors.

Resolution: Usually with high resolution, such as 12 or 14 bits, high resolution can more accurately represent the changes in the analog signal, thus improving the precision and accuracy of the measurement.

Conversion accuracy: The conversion accuracy can reach 0.1% or higher, in the whole signal input range can ensure stable and accurate signal conversion, to ensure that the collected data is true and reliable.

Sampling rate: It has a high sampling rate, which can be set according to the specific application requirements, and can generally meet the requirements of real-time data acquisition and rapid control in industrial processes.

Power supply voltage: generally 24V DC power supply, the operating voltage range is usually ± 20%, can work stably under a certain degree of power fluctuations to ensure the normal operation of the module.

Power Consumption: Low power consumption, usually between a few watts and a dozen watts, reduces the burden on the system power supply, but also helps to reduce the overall energy consumption and operating costs of the system.

Operating temperature range: generally - 20 ℃ to + 60 ℃, some special models can work in a wider temperature range, able to adapt to a variety of harsh industrial field environment temperature conditions.

Physical Characteristics

Dimensions: The external dimensions are usually small, generally about 100mm in length, 50mm in width and 20mm in height, the specific dimensions may vary from model to model, but they are all designed to be more compact and easy to be installed and laid out in the control cabinet.

Weight: Light weight, generally around 0.5kg, will not bring too much burden to the installation and maintenance, easy for operators to install, disassemble and replace.

Installation: Usually adopts the rail mounting method, which can be easily mounted on the standard DIN rail and form a complete control system together with other modules, which is very convenient for installation and removal, saving installation time and cost.

Interface type: The analog input signal adopts screw terminal interface, which is firmly and reliably connected, and is easy for wiring and maintenance; the communication interface is generally a standard industrial communication interface, such as Ethernet, PROFIBUS DP, etc., which allows high-speed and stable data communication with other devices.

Application Fields

Chemical industry: In the chemical production process, it is used to collect parameters such as temperature, pressure and liquid level of the reaction kettle, as well as information such as flow rate and composition in the pipeline, so as to realize precise control and safety monitoring of the chemical production process.

Power industry: in power plants and substations, it can be used to collect parameters such as voltage, current and power of generators, as well as operational status signals of transformers, busbars and other equipments, so as to ensure the stable operation and safe power supply of the power system.

Metallurgical industry: In the metallurgical production process of iron and steel, non-ferrous metals, etc., it can be used to collect the temperature of the heating furnace, the pressure and speed of the rolling mill and other parameters, so as to realize the automated control of metallurgical equipment and optimize the production.

Pharmaceutical industry: In the process of drug production, it can be used to collect parameters such as temperature, pH value and stirring speed of the reactor, as well as environmental parameters such as temperature, humidity and differential pressure of the clean room, so as to ensure the quality and safety of drug production.

Food and beverage industry: In the process of food and beverage processing, it can be used to collect the temperature, pressure, flow rate and other parameters of the production equipment, as well as the liquid level and temperature of the storage tank to ensure the quality and safety of food and beverage production.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications
  • Bonfiglioli 300 series reducer installation, maintenance, and troubleshooting guide
  • Selection and integration guide for Bonfiglioli R3 series planetary gearboxes in primary crushing equipment
  • Bonfiglioli C-series ATEX gearbox selection and explosion-proof application guide
  • Bonfiglioli Vectron EM-ENC-05 Full Function Expansion Module Integration Guide
  • Bonfiglioli Vectron EM-ENC-04 Multi functional Expansion Module Complete Configuration Guide
  • Bonfiglioli Vectron EM-ENC-03 Second Encoder Interface and System Bus Expansion Guide
  • Bonfiglioli Vectron EM-ENC-02 Expansion Module Integration and Encoder Interface Guide
  • Bonfiglioli Vectron CM-CAN CANopen Communication Configuration and DS402 Control Guide
  • Bonfiglioli Vectron EM-SYS System Bus Networking and Virtual Link Configuration Guide
  • Bonfiglioli Vectron CM-PDP Profibus DP Configuration and Debugging Guide
  • Bonfiglioli Vectron CM-232/485 Modbus Communication Configuration Guide
  • Bonfiglioli BMS series servo reduction motor selection and integration guide
  • Bonfiglioli ACTION 210/410 Inverter Debugging and Fault Diagnosis Complete Guide
  • Honeywell Enhanced Micro TDC 3000X System Redundancy Architecture and Maintenance Guide
  • Selection and Configuration of Bonfiglioli Active Series Inverter
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli HDP/HDO Series Heavy duty Gearboxes
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli 300/300M Series Gearboxes
  • Bonfiglioli 300M planetary gearbox selection and thermal verification guide
  • Bonfiglioli 3/H series heavy-duty gearbox selection and verification guide
  • Bonfiglioli KRG/KCG/KSD Hydraulic Coupling Selection and Integration Guide