Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • ABB NIAI02 Analog Input Termination Module
    ❤ Add to collection
  • ABB NIAI02 Analog Input Termination Module

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    NIAI02 Analog Input Termination Module
    • ¥6583.00
      ¥9699.00
      ¥6583.00
      ¥6583.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.000KG
    • Quantity:
    • (Inventory: 2)
Description
NIAI02 Analog Input Termination Module

ABB NIAI02 Analog Input Termination Module

Functional Features

Signal Adaptation and Acquisition: It can adapt a variety of common analog signal types, such as 4-20mA current signals, 0-10V or ±10V voltage signals, etc., and can be connected to various types of sensors, such as temperature sensors, pressure sensors, flow sensors, etc., to achieve the measurement of a variety of physical quantities in the industrial field and data acquisition.

Signal Conditioning and Conversion: Condition the input analog signals, including filtering, amplification, linearization and other processing to improve the quality and stability of the signal to ensure that the subsequent system can accurately carry out data processing and control. At the same time, the analog signal is converted into a digital signal to facilitate communication and interaction with the digital part of the control system.

Channel Independence: Multiple input channels are independent of each other, and each channel can be configured and used separately without interfering with each other, which facilitates separate processing and monitoring of different analog signals, and improves the flexibility and expandability of the system.

Fault diagnosis and alarm: Built-in fault diagnosis function can real-time monitor the working status of the module itself as well as the abnormal conditions of the input signals, such as signal open-circuit, short-circuit, over-range, etc., and can promptly send out an alarm signal to notify the operator to deal with the situation, which can help to improve the reliability and safety of the system.

Technical Parameters

Number of input channels: Generally there are 8 or 16 analog input channels, which can meet the requirements of industrial applications of different scales, and users can choose the appropriate number of channels according to actual needs.

Signal input range: Support a variety of standard analog signal input ranges, such as 4-20mA, 0-10V, -10V to +10V, etc., and can also be customized according to the needs of special applications, in order to adapt to the output signal range of different sensors.

Resolution: Usually with high resolution, such as 12 or 14 bits, high resolution can more accurately represent the changes in the analog signal, thus improving the precision and accuracy of the measurement.

Conversion accuracy: The conversion accuracy can reach 0.1% or higher, in the whole signal input range can ensure stable and accurate signal conversion, to ensure that the collected data is true and reliable.

Sampling rate: It has a high sampling rate, which can be set according to the specific application requirements, and can generally meet the requirements of real-time data acquisition and rapid control in industrial processes.

Power supply voltage: generally 24V DC power supply, the operating voltage range is usually ± 20%, can work stably under a certain degree of power fluctuations to ensure the normal operation of the module.

Power Consumption: Low power consumption, usually between a few watts and a dozen watts, reduces the burden on the system power supply, but also helps to reduce the overall energy consumption and operating costs of the system.

Operating temperature range: generally - 20 ℃ to + 60 ℃, some special models can work in a wider temperature range, able to adapt to a variety of harsh industrial field environment temperature conditions.

Physical Characteristics

Dimensions: The external dimensions are usually small, generally about 100mm in length, 50mm in width and 20mm in height, the specific dimensions may vary from model to model, but they are all designed to be more compact and easy to be installed and laid out in the control cabinet.

Weight: Light weight, generally around 0.5kg, will not bring too much burden to the installation and maintenance, easy for operators to install, disassemble and replace.

Installation: Usually adopts the rail mounting method, which can be easily mounted on the standard DIN rail and form a complete control system together with other modules, which is very convenient for installation and removal, saving installation time and cost.

Interface type: The analog input signal adopts screw terminal interface, which is firmly and reliably connected, and is easy for wiring and maintenance; the communication interface is generally a standard industrial communication interface, such as Ethernet, PROFIBUS DP, etc., which allows high-speed and stable data communication with other devices.

Application Fields

Chemical industry: In the chemical production process, it is used to collect parameters such as temperature, pressure and liquid level of the reaction kettle, as well as information such as flow rate and composition in the pipeline, so as to realize precise control and safety monitoring of the chemical production process.

Power industry: in power plants and substations, it can be used to collect parameters such as voltage, current and power of generators, as well as operational status signals of transformers, busbars and other equipments, so as to ensure the stable operation and safe power supply of the power system.

Metallurgical industry: In the metallurgical production process of iron and steel, non-ferrous metals, etc., it can be used to collect the temperature of the heating furnace, the pressure and speed of the rolling mill and other parameters, so as to realize the automated control of metallurgical equipment and optimize the production.

Pharmaceutical industry: In the process of drug production, it can be used to collect parameters such as temperature, pH value and stirring speed of the reactor, as well as environmental parameters such as temperature, humidity and differential pressure of the clean room, so as to ensure the quality and safety of drug production.

Food and beverage industry: In the process of food and beverage processing, it can be used to collect the temperature, pressure, flow rate and other parameters of the production equipment, as well as the liquid level and temperature of the storage tank to ensure the quality and safety of food and beverage production.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • OMRON CPM1A Maintenance and Troubleshooting
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide