ABB NIAI04 Analog Input Termination Module
Functional features
Various signal acquisition: It can receive various types of analog input signals, such as 4-20mA current signal, 0-10V voltage signal, thermocouple and RTD signal, etc., which can meet the signal access requirements of different sensors, and is suitable for the measurement of various industrial process parameters.
Higher precision: with high signal conversion precision, it can accurately convert analog signals into digital signals to ensure the accuracy and reliability of the measurement data, thus realizing precise control of industrial processes.
Strong reliability: the use of high-quality electronic components and advanced manufacturing process, with good anti-interference ability, can operate stably in harsh industrial environments, reducing failures and data errors caused by environmental factors.
Convenient fault diagnosis: the module has a built-in simple fault diagnosis program, which can quickly locate and diagnose faults in the module itself as well as in the sensors and lines connected to it, making it easy to carry out timely repairs and maintenance and reducing system downtime.
Good compatibility: As part of the ABB Bailey INFI 90 system, it has good compatibility and working ability with other components of the system, and can be easily integrated into existing control systems to realize flexible system configuration and expansion.
Technical Parameters
Number of input channels: generally 8 or 16 analog input channels, the specific number can be selected according to the actual application requirements.
Signal input range: support a variety of standard analog signal range, such as 4-20mA, 0-10V, -10V to +10V, etc., can also be customized according to the requirements of special sensors.
A/D conversion resolution: usually 12-bit or 14-bit, higher resolution can provide more accurate signal conversion and measurement results.
Conversion Accuracy: The accuracy can be 0.1% or higher, which ensures high-precision signal conversion over the entire measurement range.
Sampling rate: high sampling rate to meet the requirements of real-time data acquisition in industrial processes, the specific sampling rate depends on the system configuration and application requirements.
Power supply voltage: generally 24V DC power supply, the operating voltage range is usually ± 20%, to ensure that the module can still work properly in a certain power fluctuation range.
Power Consumption: Low power consumption, generally between a few watts to a dozen watts, reducing the burden on the system power supply and energy consumption.
Operating temperature range: generally - 20 ° C to + 60 ° C, some special models can work in a wider temperature range, to adapt to a variety of industrial site ambient temperature conditions.
Storage temperature range: typically - 40 ℃ to + 85 ℃, in the equipment storage and transportation process can withstand more extreme temperature conditions.
Physical Characteristics
Dimensions: Approximately 10.2cm x 12.7cm x 17.8cm, compact size for easy installation and layout in control cabinets.
Weight: Approx. 0.5kg, which is lightweight and will not bring too much burden for installation and maintenance.
Installation: Usually rail-mounted, it can be easily mounted on a standard DIN rail, and together with other modules, it forms a complete control system, which is very convenient to install and dismantle.
Interface type: The analog input signal adopts screw terminal interface, which is firmly and reliably connected and easy for wiring and maintenance; the communication interface is generally Ethernet, PROFIBUS DP and other standard interfaces, which can carry out high-speed and stable data communication with other devices.
Application Fields
Energy and power industry: in power plants, it can be used to collect analog signals such as voltage, current and temperature of generators, as well as the operating parameters of various electrical equipment in substations, realizing real-time monitoring and control of the power system.
Chemical and petrochemical industry: in the chemical production process, it can be connected to temperature sensors, pressure sensors, flow sensors, liquid level sensors, etc., to accurately measure and monitor the operating parameters of the reactors, pipelines, tanks and other equipment to ensure the safety and stability of chemical production.
Metallurgical industry: In the metallurgical production process of iron and steel, non-ferrous metals, etc., it can be used to collect analog signals such as the temperature of the heating furnace and the pressure of the rolling mill, so as to realize the automated control of metallurgical equipments and optimize the production.
Pharmaceutical and food and beverage industry: In the process of pharmaceutical production and food and beverage processing, it can be used to collect the temperature of the reaction kettle, the flow rate of pharmaceutical water, the temperature and humidity of the clean room and other data to ensure the stability of the production environment and product quality.
Water treatment industry: in sewage treatment plants and water plants, it can be used to collect analog signals of water quality parameters such as pH value, dissolved oxygen, turbidity, etc., as well as signals of pumps, valves, and other equipment operation status, to realize the automation monitoring and management of the water treatment process.