Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • ABB NKLS11-8 Infi-net Interface Cable -8 feet
    ❤ Add to collection
  • ABB NKLS11-8 Infi-net Interface Cable -8 feet

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    NKLS11-8 Infi-net Interface Cable -8 feet
    • ¥3719.00
      ¥11910.00
      ¥3719.00
      ¥3719.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.000KG
    • Quantity:
    • (Inventory: 2)
Description
NKLS11-8 Infi-net Interface Cable -8 feet

ABB NKLS11-8 Infi-net Interface Cable -8 feet

Basic Properties

Physical Characteristics:

Appearance and Size: Usually round in appearance, the outer jacket is usually made of black or grey polyvinyl chloride (PVC), which is soft, abrasion-resistant and corrosion-resistant, and the diameter is of medium thickness to facilitate wiring and installation in bridges, trunking or inside equipment in industrial sites, with a length of 8 feet.

Markings and materials: The cable is clearly marked with the model number ‘NKLS11-8’ and the ABB brand logo. Its internal conductor is made of high quality copper with good electrical conductivity and corrosion resistance, and the insulation and sheath materials are made of high quality PVC or other high performance insulation materials, which can effectively prevent signal interference and leakage.

Electrical Characteristics:

Signal transmission type: mainly used for transmitting digital signals, in the ABB Bailey Infi 90 system, to achieve data transmission and interaction between the network interface devices, to ensure that the communication between the various parts of the system is normal.

Transmission rate and stability: it can meet the requirements of ABB Bailey Infi 90 system on signal transmission rate, and the signal attenuation is small within the specified 8 feet transmission distance, which can ensure the stability and reliability of the signal and reduce the signal distortion and BER, so as to guarantee the normal operation of the system.

Rated voltage and current: The rated voltage is generally 300V AC, and the wire gauge and other parameters are designed to meet the normal working voltage and current requirements of the equipment in the ABB Bailey Infi 90 system.

Functions

Network connection: Provide reliable connection for network interface devices in ABB Bailey Infi 90 system, such as connecting different controllers, communication modules, I/O modules, etc., to build up a stable industrial control network, and realise data exchange and collaborative work between various devices in the system.

Guaranteeing communication quality: High-quality materials and advanced manufacturing processes are used to effectively reduce attenuation, distortion and interference in the signal transmission process, guaranteeing the accurate transmission of data between different network interface devices, thus ensuring the stable operation and control accuracy of the system.

Application Fields

Industrial automation control system: such as automated production lines and process control systems in chemical, iron and steel, electric power, petroleum and other industries, it is used to connect key network interface devices to ensure the reliable operation of the system and prevent production accidents and economic losses caused by communication failure.

Intelligent building control system: In the building automation system of large commercial buildings, hospitals, airports, etc., it is used to connect various intelligent devices and control systems, such as controllers of air-conditioning system, lighting system, security system, etc., to ensure stable operation and intelligent management of the system.

Main features

· 24 digital inputs with LED displays 

· 16 digital transistor outputs with LED displays 

· 8 digital inputs/outputs with LED displays 

· 8 individually configurable analog inputs 0...10 V, 0...5 V, ±10 V, ±5 V, 0...20 mA, 4...20 mA, differential inputs, Pt100 (2-wire or 3-wire), the analog inputs are also individually configurable as digital inputs 

· 4 individually configurable analog outputs ±10 V, 0...20 mA, 4...20 mA 

· 2 counters for counting frequencies up to 50 kHz, configurable in 7 different operating modes · 1 CS31 system bus interface for system expansion 

· 1 interface for connecting communication modules (e.g. 07 KP 90) 

· 2 serial interfaces COM1, COM2 

– as MODBUS interfaces and 

– for programming and test functions 

· Real-time clock 

· LEDs for displaying operating conditions and error messages 

· Detachable screw-type terminal blocks 

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice