Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • ABB NTU-7/6/48S1 Digital Input Termination Unit
    ❤ Add to collection
  • ABB NTU-7/6/48S1 Digital Input Termination Unit

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    NTU-7/6/48S1 Digital Input Termination Unit
    • ¥3898.00
      ¥14216.00
      ¥3898.00
      ¥3898.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.000KG
    • Quantity:
    • (Inventory: 2)
Description
NTU-7/6/48S1 Digital Input Termination Unit

ABB NTU-7/6/48S1 Digital Input Termination Unit

Basic Information

Model Meaning: ‘NTU-7/6/48S1’ is the specific model number of the product, where ‘NTU’ stands for Digital Input Terminal Unit, ‘7/6’ and so on may represent a specific series or functional distinction, ‘48’ may be related to the number of input channels or other technical parameters, ‘S1’ may indicate a version or a specific configuration. where ‘NTU’ stands for Digital Input Terminal Unit, ‘7/6’ etc. may represent a specific series or functional distinction, ‘48’ may be related to the number of input channels or other technical parameters, ‘S1’ may denote a version or a specific configuration, etc.

Series: belongs to ABB Bailey Infi 90 series, this series is ABB company for industrial automation control system launched a set of high-performance, distributed control system, widely used in electric power, chemical industry, metallurgy, paper and other industries in the field of automation control.

Place of origin and availability: the product originated in Sweden, from some suppliers can be enquired to have a certain amount of stock, the supply cycle is generally 3-5 days.

Functional characteristics

Signal Acquisition: With 48 digital input channels, it can acquire multiple digital signals at the same time, and can receive dry contact signals and active signals, such as 24V DC, 48V DC and other digital level signals of different voltage levels, to meet the signal access requirements of a variety of digital sensors and devices in the industrial field.

Signal Processing: Logical judgement and processing of the collected digital signals, such as the implementation of the signal with, or, or non-logical operations, according to the preset logical conditions of the input signals for the combination of judgement, the output of the corresponding control signals, to achieve the complex control logic function.

Electrical isolation: electrical isolation technology is adopted between the input channel and the internal circuit, and the isolation voltage can reach thousands of volts, which effectively prevents the influence of external interference signals on the system, improves the stability and reliability of the system, and guarantees the safety of the equipment and the operators at the same time.

Status Indication: Equipped with status indicator, it can intuitively display the signal status of each input channel, which is convenient for on-site maintenance personnel to quickly understand the operation of the equipment, and discover the fault points in time and carry out maintenance.

Technical parameters

Power requirements: the working voltage is generally DC voltage, the range is about 18V-30V DC, the typical working current varies according to different working conditions, but generally within a few hundred milliamps.

Input Signal Range: For dry contact signals, the external power supply voltage range is wide, usually between 5V-30V DC; for active signals, it can adapt to a variety of voltage ranges, such as TTL levels, CMOS levels and industrial standard 24V DC signals, etc., and the input current ranges from a few milliamps to tens of milliamps.

Response Time: Typical response times are between microseconds and milliseconds, enabling fast acquisition and processing of input signals to ensure that the control system obtains the latest state of the equipment in a timely manner and achieves fast response and precise control.

Operating temperature range: usually in the - 20 ℃ - + 70 ℃ or so, some high-performance products may support a wider temperature range, can adapt to a variety of harsh industrial field environment.

Protection level: generally with IP20 or higher protection level, to prevent the intrusion of foreign objects into the equipment, while avoiding accidental contact with the internal circuitry, to ensure the safe operation of the equipment in the industrial environment.

Application Areas

Industrial automated production line: In automated production lines such as automotive manufacturing, machining, electronic assembly, etc., it is used to collect signals of the running status of the equipment, such as the start/stop signal of the motor, the signal of the position sensor of the conveyor belt, the signal of the working status of the robots, etc., so as to realise the centralized monitoring and automated control of the equipment in the production line.

Process control system: In the process control system of chemical industry, pharmaceutical industry and metallurgy industry, it is used to collect the monitoring signals of various process parameters, such as the temperature alarm signal of the reaction kettle, the switching status signal of the valve, and the running signal of the stirring motor, etc., to provide real-time information of the production process for the operators, and to ensure the safety and stability of the production process.

Intelligent building system: In the heating, ventilation and air conditioning (HVAC) system, lighting system and lift system of an intelligent building, it collects the status signals of the equipment, such as the run/stop signals of the air conditioning unit, the switching status signals of the lighting fixtures and the floor position signals of the lift, etc., so as to achieve the centralised monitoring and management of the building equipment, and to enhance the efficiency of the use of energy and the comfort level.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice