ABB PHBAIN2000S200 Analog Input Base - Harmony Block I/O
Basic Information
Model and origin: PHBAIN2000S200, origin is Sweden.
Series: It belongs to Harmony Block I/O series, which can be used with other modules of this series to build a complete industrial automation control system to meet different industrial control needs.
Features
Multiple analogue signal inputs: It supports multiple types of analogue signal inputs, such as 4-20mA DC, 0-10V DC and other common industrial standard analogue signals, and can also be adapted to thermocouples, RTDs, and other temperature sensors, which can satisfy the signal input requirements of different sensors, and thus can be widely used in a variety of industrial scenarios for the measurement and monitoring of different physical quantities.
High-precision signal conversion: High-precision conditioning and conversion of input analogue signals can accurately convert physical signals collected by sensors into digital signals for accurate processing and analysis by the control system, which effectively ensures the precision of industrial process control and helps to improve the stability of the production process and the consistency of product quality.
Good system compatibility: As an important part of the Harmony Block I/O system, it has excellent compatibility with other modules and devices in the ABB Bailey Infi 90 and Net 90 series, and can be seamlessly integrated into the existing control system to achieve flexible system expansion and upgrading, which reduces the difficulty and cost of system integration, and makes it convenient for users to build and expand industrial automation control systems according to actual needs. It reduces the difficulty and cost of system integration and facilitates users to build and expand industrial automation control systems according to actual needs.
Technical Parameters
Number of input channels: usually equipped with multiple analogue input channels, the specific number of specific configurations based on the product, common 8-channel, 16-channel and other configurations, can be connected to a number of analogue sensors at the same time, to achieve parallel monitoring of multiple physical quantities, to improve the monitoring efficiency, to meet the needs of the complex industrial process of multi-parameter monitoring.
Signal resolution: has a high signal resolution, generally up to 12 bits or higher, can accurately distinguish and transmit small changes in the analogue signal, its specific resolution varies depending on the signal type and measurement range, so as to ensure the accuracy of the measurement data, to provide strong support for precise control.
Sampling rate: With a faster sampling rate, the analogue signal can be sampled several times in a short period of time to obtain more accurate signal data, to meet the requirements of the control system on the real-time and dynamic response, the specific sampling rate may also vary depending on the specific configuration of the product.
Application Fields
Industrial automation process control: Widely used in chemical industry, electric power, metallurgy, papermaking and other types of industrial automation control system, through the connection of temperature sensors, pressure sensors, flow sensors and other analogue equipment, to achieve real-time monitoring and accurate control of various physical quantities in the production process, to ensure the stable operation of the production process and consistency of product quality, to improve production efficiency and economic benefits.
Energy management system: In the energy management system, it can be used to monitor power parameters, energy consumption and other analogue data to provide data support for the rational distribution and optimal use of energy, helping enterprises to achieve energy saving and emission reduction and reduce operating costs, improve the efficiency of energy use, and enhance the enterprise's ability to achieve sustainable development.
Intelligent Building System: In the air-conditioning system, ventilation system and lighting system of the building, by connecting the corresponding sensors, it realises the monitoring and control of the environmental parameters and the operation status of the equipments, improves the energy use efficiency and comfort of the building, and creates a more comfortable and healthy working and living environment for people.
Maintenance
Appearance Inspection: Regularly inspect the appearance of the analogue input base to see if there are signs of damage, looseness or corrosion, etc. If there are any problems, it should be replaced or repaired in a timely manner to ensure its normal operation and to avoid interruption or abnormality of signal transmission due to hardware damage.
Cleaning and heat dissipation maintenance: keep the equipment clean, prevent dust, oil and other pollutants from entering the interface or internal circuitry, affecting signal transmission and heat dissipation performance, you can use clean compressed air or special cleaning agents for cleaning, while ensuring that the equipment is installed in a well-ventilated location to ensure that its heat dissipation effect, to prevent overheating leading to a decline in the performance of the equipment or failure.
Calibration and verification: According to the actual use of the situation and requirements, regular calibration of the analogue input signal calibration, to ensure the accuracy and reliability of the signal, the calibration process should use professional calibration equipment and tools, and in accordance with the relevant standards and norms of the operation, in order to ensure the accuracy of the measurement data and the effectiveness of the system control.