  • ABB PHBAIN22010000 Analog Input Base - Harmony Block I/O
    ❤ Add to collection
  • ABB PHBAIN22010000 Analog Input Base - Harmony Block I/O

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    PHBAIN22010000 Analog Input Base - Harmony Block I/O
    • ¥7714.00
      ¥10620.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.000KG
    • Quantity:
    • (Inventory: 2)
Description
PHBAIN22010000 Analog Input Base - Harmony Block I/O

ABB PHBAIN22010000 Analog Input Base - Harmony Block I/O

Basic Information:

Model number: PHBAIN22010000 is the model number of this product, by which this particular analogue input base product can be accurately identified.

Place of Origin: Originally from Sweden.

Functional features:

Wide range of signal inputs: Sixteen isolated analogue input channels can receive 4-20mA DC, -10 to +10V DC, -100 to +100mV DC and many types of thermocouple signals, including B, E, J, K, L, N, R, S, T, U, China E, S type, etc., which can meet the needs of different sensors, and is suitable for a variety of industrial measurement scenarios. Signal Processing and Transmission Precision

Accurate signal processing and transmission: High-precision processing and transmission of input analogue signals ensures signal accuracy and stability, ensuring that the control system is able to obtain accurate information about physical quantities, thus achieving precise control of industrial processes.

Good compatibility: As part of the Harmony Block I/O system, it has good compatibility with other modules and devices in the ABB Bailey Infi 90 and Net 90 series, and can be easily integrated into existing control systems to achieve flexible system expansion and upgrading.

Technical parameters:

Number of input channels: 16 isolated analogue input channels, can be connected to multiple analogue sensors at the same time, to achieve parallel monitoring of multiple physical quantities, improve the monitoring efficiency of the system.

Signal resolution: with high signal resolution, it can accurately distinguish and transmit small changes in analogue signals, thus ensuring the accuracy of the measurement data and providing strong support for precise control, the specific resolution varies according to the type of signal and measurement range.

Anti-interference ability: Adopting effective isolation technology and filtering measures, it has strong anti-interference ability and can work stably in the complex industrial electromagnetic environment, ensuring the reliability of signal transmission and reducing the measurement errors and system failures caused by interfering signals.

Application areas:

Industrial automation process control: Widely used in chemical industry, electric power, metallurgy, papermaking and other types of industrial automation control system, used to connect temperature sensors, pressure sensors, flow sensors and other analogue equipment, to achieve real-time monitoring of various physical quantities in the production process and accurate control, to ensure the stable operation of the production process and product quality consistency.

Energy management system: In the energy management system, it can be used to monitor power parameters, energy consumption and other analogue data to provide data support for the rational distribution and optimal use of energy, and help enterprises achieve the goal of energy saving and emission reduction and reduce operating costs.

Intelligent Building System: In the air-conditioning system, ventilation system, lighting system, etc. of the building, through the connection of the corresponding sensors, to achieve the monitoring and control of the environmental parameters and equipment operation status, to improve the energy efficiency and comfort of the building.

Maintenance and upkeep:

Regular inspection of appearance: Regularly inspect the appearance of the analogue input base to see if there are signs of damage, looseness or corrosion, etc. If there is any problem, it should be replaced or repaired in time to ensure its normal operation.

Cleaning and heat dissipation maintenance: Keep the equipment clean to prevent dust, oil and other pollutants from entering the interface or internal circuitry, affecting signal transmission and heat dissipation performance, you can use clean compressed air or special cleaners to clean, while ensuring that the equipment is installed in a well-ventilated location to ensure its heat dissipation effect.

Calibration and verification: According to the actual use of the situation and requirements, regular calibration of analogue input signals to ensure the accuracy and reliability of the signal, the calibration process requires the use of professional calibration equipment and tools, and in accordance with the relevant standards and norms of operation.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ADLINK-PXIe-3988-3987-3977-3937-TL Controller Deployment and Maintenance Guide
  • ADLINK PXI-2020/2022 Synchronous Acquisition Card Configuration and Synchronization Guide
  • ADLINK DAQ/PXI-2000 series synchronous acquisition card configuration and triggering
  • ADLINK PXES-2788 series chassis deployment and maintenance
  • ADLINK PXES-2785 18 Slot Gen3 Chassis Deployment and Maintenance Guide
  • ADLINK PXES-2780 18 Slot PXIe Chassis Deployment Configuration
  • ADLINK PXES-2596 Gen3 Chassis Installation and Maintenance Guide
  • ADLINK PXES-2590 Chassis Deployment and System Management
  • ADLINK PXES-2314T Chassis Deployment and Troubleshooting Guide
  • ADLINK PXES-2301 Chassis Installation Monitoring and Troubleshooting
  • ADLINK PCIe-U300 Series USB3 Vision Acquisition Card Deployment Guide
  • ADLINK PCIe PXIe-8565 Expansion Kit Remote Control and Compatibility
  • Installation and troubleshooting of ADLINK PCIe GIE74V four channel PoE acquisition card
  • ADLINK PCIe GIE7x Poe+Acquisition Card Configuration and Triggering Troubleshooting
  • Advanced triggering and multi card synchronization of ADLINK PCIe-CPL64V image acquisition card
  • ADLINK PCIe-CPL64 Image Acquisition Card Hardware Trigger and Encoder Application
  • Application and troubleshooting of ADLINK PCIe-8560/PXI-8565 expansion kit
  • ADLINK PCIe 8332/PCIe 8334/PCIe 8338 EtherCAT Motion Controller Multi axis Synchronous Control
  • ADLINK PCIe-7432 32 channel isolated I/O card interrupt and driver
  • ADLINK PCIe-7256 Industrial I/O Card Interruption and Relay
  • ADLINK PCIe-833x EtherCAT Motion Controller Debugging and Maintenance
  • ADLINK PCIe-10GPoE 10GigE Visual Acquisition Card Practical Use
  • ADLINK PCI-8254/8258 Motion Controller Debugging and Maintenance
  • Application and Maintenance of ADLINK PCI-8158 Multi axis Motion Control Card
  • ADLINK PCI-8134A Maintenance and Troubleshooting Guide
  • ADLINK PCI-7250 Series Relay Output Card Configuration and Protection Circuit Guide
  • ADLINK PCI-6308 Series Isolated Analog Output Card Configuration and Programming
  • ADLINK PanKonix Series HMI Panel Selection and Deployment Guide
  • ADLINK NuDAM-6100 Series I/O Module Deployment and Protocol Optimization
  • Deployment and Calibration of ADLINK NuDAM-6000 Data Acquisition Module
  • ADLINK NEON-2000-Ono Intelligent Camera Deployment and Trigger Optimization
  • ADLINK NuDAM-65xx Communication Module Networking and Configuration Guide
  • ADLINK NuDAM-60xx Series Digital I/O Module Deployment and Watchdog Optimization
  • ADLINK MXE-5300 Fanless Industrial Control Computer Deployment and Troubleshooting Manual
  • ADLINK MXE-310 edge computing Platform Hardware Installation and BIOS Tuning
  • ADLINK MXE-230 series Alder Lake platform industrial computer deployment and maintenance manual
  • ADLINK MXE-210 Compact Fanless Industrial Control Computer Hardware Deployment and Debugging Guide
  • ADLINK MXC-3300/3340 Embedded Industrial Control Computer Hardware Integration and Debugging Manual
  • ADLINK MXA-312M Edge AI Platform Hardware Integration and Debugging Guide
  • ADLINK MXA-200 IoT Gateway Hardware Installation and Linux System Debugging Complete Guide
  • ADLINK MVP-6200 Industrial Control Computer: PCIe Gen4 and PCI Hybrid Expansion
  • ADLINK MVP-6100 Industrial Control Computer: PCI/PCIe Expansion and Robust Design
  • ADLINK MVP-5200 Industrial Control Computer: High Performance Multi Display and TSN Network
  • ADLINK MVP-5100 Fanless Industrial Control Computer Deployment and Development Guide
  • ADLINK MVP-3100 and MVP-3120 Embedded Systems
  • ADLINK MNET-J3/S23/MIA/DA2/SAN Single Axis Module Installation and Wiring Guide
  • ADLINK MNET-4XMO/C Motion Module Installation and Debugging Guide
  • ADLINK MCM-216/218 Edge DAQ Deployment Configuration Guide
  • ADLINK LPCIe-8124-C Encoder Card Trigger Configuration Guide
  • ADLINK IM/OM Series Industrial Display Installation and Debugging Guide
  • ADLINK GW-01 Industrial IoT Gateway Configuration and Debugging Guide
  • EURESYS Grablink Collection Card Selection and Trigger Configuration Guide
  • ADLINK Express HL Module Selection and Heat Dissipation Configuration Guide
  • ADLINK EOS-2000 Visual System Installation and Troubleshooting
  • ADLINK EOS-1200 Installation, Configuration, and Troubleshooting
  • Application and Configuration of ADLINK ECS-8582-4S Extension System
  • ADLINK DIN-814P-A4 Panasonic servo adapter board configuration
  • ADLINK DIN-814M-J3A Mitsubishi servo adapter board configuration
  • ADLINK DIN-814-GP Universal Adapter Board Configuration
  • Application and Configuration of ADLINK DIN-812M Adapter Board
  • Application and Configuration of ADLINK DIN-814Y Adapter Board
  • ADLINK DAQ/DAQE/PXI-250x waveform generation complete guide
  • ADLINK DAQ/DAQE/PXI-220x acquisition card fully configured
  • Application and Configuration of ADLINK cPCI-9116 Data Acquisition Card
  • ADLINK cPCI/PCI-8554/R: A Complete Guide from Architecture to Application
  • ADLINK cPCI-7432/7433/7434 isolated I/O card
  • ADLINK cPCI-3544/3534/3538 Serial Cardcard Configuration Practice
  • ADLINK cPCI-3534/3538/3544 Multi Serial Port Card Configuration Complete Solution
  • Complete Technical Guide for Euresys Coaxlink CXP Capture Card
  • ADLINK AMP-304C Advanced Motion Control Card Complete Guide
  • ADLINK AMP-104C Four Axis Motion Control Card
  • ADLINK NEON-1020/1040 Smart Camera
  • ADLINK USB-7230/7250 Isolation I/O Module Operation Manual
  • ADLINK SP-15W03 Intelligent Panel Integration and Configuration Manual
  • ADLINK AMP-20xC Interface Configuration and Wiring Guide
  • ADLINK 3488A GPIB Interface Card Selection Guide
  • Complete solution of ETEL TMB+torque motor selection parameters
  • ADLINK RTV series frame grabber deployment guide
  • ADLINK PCIe-FIW64/62 Image Acquisition Card Configuration Guide
  • ADLINK 6208/6216-GL Analog Output Card
  • ADLINK 723X Isolation I/O Card Configuration Guide
  • ADLINK PCI-9118 series high-speed DAQ card selection and DMA configuration
  • ADLINK PCI-9114 (A) Data Acquisition Card Selection and Configuration Guide
  • ADLINK PCI-7442/7443/7444 Isolation I/O Card Selection and Safety Configuration
  • ADLINK PCI-7250/7251 Relay Output Card Selection and Expansion Guide
  • Selection and Protection Configuration of Advantech PCI-1610CU Multi Serial Port Card
  • ADLINK NEON-1000-MDX Smart Camera Deployment and Trigger Configuration
  • ADLINK MXE-1300 Industrial Control Computer Selection and Deployment Guide
  • ADLINK MXE-200 Industrial Control Computer Deployment and BIOS Optimization Guide
  • ADLINK LPCIe-3488A GPIB Card Installation and Configuration Guide
  • Guidelines for Key Technologies of ETEL LMG/LMS Linear Motor Integration
  • ETEL IL+/LM Linear Motor Selection and Integration Guide
  • ETEL DSCDP/DSCDL/DSCDM Dual Axis Controller Debugging Guide
  • ETEL DSCDL Dual Axis Controller Hardware Integration Guide
  • ETEL DSB2P Series Servo Amplifier Connection and Configuration Guide
  • ETEL DSC2P/DSC2V Servo Controller Debugging Guide
  • DFI HD636-H81CS Industrial Motherboard Deployment and Debugging
  • Integration and Optimization of ADLINK DAQ-20xx Synchronous Acquisition Card
  • ADLINK cPCI-6530 Core i7 Blade Computer Deployment Guide
  • ADLINK cPCI-3610 Blade Computer Integration and Debugging
  • ADLINK AMP-204C/208C Troubleshooting Guide
  • ADLINK AmITX ALN Industrial Motherboard Characteristics and Application Analysis
  • ADLINK NuPRO-850 Motherboard Installation and Configuration Guide
  • ADLINK MI-965 Motherboard Installation and BIOS Configuration Guide
  • ADLINK M-302 Industrial Motherboard Installation and BIOS Optimization Guide
  • ADLINK PXI-3920/3910 Controller Installation and Configuration Guide
  • ADLINK PCI-8132 Motion Control Card Installation, Programming, and Debugging Guide
  • ADLINK cPCI-6760D/P7/P8 Module Installation and Hot Plug Guide
  • ADLINK ACL-7122 Digital I/O Card Installation and Programming
  • ADLINK NuPRO-775 Industrial Motherboard Installation and BIOS Configuration Detailed Explanation
  • ETEL Accuret MODULAR 300/400/600 Controller Selection Guide
  • Edwards CTI Kryogenics On Board 8F Enhanced Cryopump Explanation
  • ADLINK PCI-9112 Multi functional Data Acquisition Card
  • ADLINK PCI-8102 Two Axis Pulse Motion Control Card
  • ADLINK PCI-9812/10 high-speed synchronous acquisition card
  • ADLINK PCI-7200 High Speed Digital I/O Card
  • ADLINK MXE-1000 series fanless industrial computer
  • ADLINK IMB-T10 Mini ITX Embedded Motherboard
  • ADLINK HSL-DO32-M-N/P distributed I/O module
  • ADLINK DAQ-2500 Series Multi Channel Analog Output Card
  • ADLINK DAQ-2200 Series Data Acquisition Card
  • ADLINK ETX-AT-N270 Embedded Module
  • ADLINK ACL-7225B Relay Isolation Input Card Guide
  • ADLINK DAQ-2000 Synchronous Sampling and Acquisition Card Selection Guide
  • ADLINK NuPRO-E330 Industrial Motherboard Selection and Deployment
  • ADLINK ACL-8112 Data Acquisition Card Configuration and Programming
  • ADLINK USB-2405 Dynamic Signal Acquisition Module Deployment Guide
  • ADLINK PXIS-3320 PXI chassis installation troubleshooting