Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • RELIANCE GV3000/SE AC General Purpose and Vector Drive
    ❤ Add to collection
  • RELIANCE GV3000/SE AC General Purpose and Vector Drive

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    RELIANCE GV3000/SE AC General Purpose and Vector Drive

    • ¥23650.00
      ¥24520.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.500KG
    • Quantity:
    • (Inventory: 35)
Description

RELIANCE GV3000/SE AC General Purpose and Vector Drive


RELIANCE GV3000/SE AC General Purpose and Vector Drive

DESCRIPTION

The variable-voltage, variable-frequency power inverters of the GV3000/SE series are ready for installation and are available in different sizes with output currents in the range 2 to 360 Amps. They are designed to drive induction motors at variable speeds using PWM technology. The protective enclosure contains the Power Module and the Control Unit with the Keypad.

- RMI Card (Remote Meter Interface Card) 

• 3 isolated analog outputs for displaying, 

• 1 isolated analog input, 

• 4 programmable digital outputs, 

• 4 digital inputs, 

• 1 frequency input, 

• 3 relay outputs, 

• 1 frequency output.

Electrical Description

Three phase input power is applied to terminals L1, L2, and L3 via external standard input fuses or fused isolator. Power is then fed to the precharge circuitry through the optional input filter circuit. This filter keeps conducted emissions in the high frequency range within the limits as per EMC product standards. The current transformer T4 senses ground fault currents (on types 038/043 and 058 - 360). The internal switching power supply develops the isolated DC 24 V control voltage and different supply voltages (DC ±5 to 24V) for the controller operation. An optional, user supplied AC-line input reactor allows the Power Module to be operated on any supply line also with high fault level (refer to chapter 5, Accessories). On types GV3000E-AC003 - 030 and 039/044 the inductance of the optional RFI filter allows connection to supply transformers with a fault level up to 29 kA (e.g. 1000 kVA) after which a choke should be fitted.

When line voltage (or DC-bus voltage on type DC240 and DC360) is applied at the input terminals (external main contactor has picked up), the DC-bus begins charging. The DC-bus voltage increases to a value 1.4 times the no-load three-phase line voltage on types AC003 - 170 resp. to the value of the applied DC-voltage on type DC240 and DC360. Precharge resistors limit the DC-bus capacitors' charging current. When the DC-bus reaches 95% of its rated voltage, the parallel connected precharge contactors close and bypass the resistors.

Product Features

Versatility: GV3000/SE may be a general-purpose drive suitable for a wide range of industrial applications, able to meet different loads and process requirements.

Vector control: As a vector drive, GV3000/SE is able to achieve high-precision control of the motor, including precise adjustment of parameters such as speed, torque and position, thus improving the dynamic response and stability of the system.

High efficiency: With advanced control algorithms and power conversion technology, GV3000/SE can achieve high efficiency energy conversion and utilisation, reducing energy consumption and operating costs.

Flexible configuration: may support a variety of parameter settings and programming methods, the user can according to the specific needs of flexible configuration and optimisation to meet different control needs.

Protection function: It has perfect protection function, such as over-current, over-voltage, under-voltage, over-heat protection, etc. It can automatically cut off the power supply or reduce the output power in abnormal situation, so as to protect the motor and drive from damage.

Application Areas

RELIANCE GV3000/SE AC General Purpose and Vector Drive may be widely used in industrial automation, machinery manufacturing, textile, printing, packaging, food processing and other fields, for a variety of need for precise control of the motor to provide reliable drive solutions.

Precautions

When purchasing and using RELIANCE GV3000/SE AC General Purpose and Vector Drive, it is recommended to refer to the product manual and technical specification sheet to understand its specific technical parameters, performance indexes and use requirements.

During installation, commissioning and maintenance, it should be operated in strict accordance with relevant safety regulations and operating procedures to ensure personal safety and stable operation of the equipment.

For more detailed product information and technical support, it is recommended to contact RELIANCE's official channels or authorised distributors for consultation.



  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Bosch Rexroth Indramat PPC-R02 Controller Replacement Guide
  • Phoenix Contact Inline I/O System Selection Guide
  • Rexroth VCP 08 Operating Terminal Selection and Installation Guide
  • Rexroth IndraDyn H Spindle Motor Planning Guide
  • Detailed explanation of ElectroLogIXS VLC interlocking signal controller
  • Yokogawa AIP830 Single Circuit Operation Keyboard
  • Yokogawa RAMC flowmeter selection and troubleshooting
  • YASKAWA GA500 frequency converter troubleshooting
  • TRACO TIS600 power supply
  • Sigmatek ETV-0851 Control Panel Troubleshooting
  • Allen Bradley Quest AN-X2-AB-DHRIO Remote I/O Adapter Integration and Troubleshooting
  • Meggitt RPS6U power supply
  • Kongsberg RCU500 Controller Integration and Fault Diagnosis Guide
  • KBAC series frequency converter installation and fault diagnosis guide
  • EXOR effectiveness View eV058 series HMI industrial panel
  • Emerson OCR3000 Controller Troubleshooting Guide
  • Emerson Ovation OCR1100 Controller Maintenance and Troubleshooting
  • Elmo G-TUB30 Driver Troubleshooting Guide
  • Troubleshooting and Optimization of Basler A400 Series Camera
  • Troubleshooting and Maintenance of Automated Logic I/O Expansion Module
  • Troubleshooting and Maintenance of Aerotech UNIDEX 100 Controller
  • ADVANEST R6144 calibration source troubleshooting
  • Troubleshooting and Calibration of ABB Millmate Tension Gauge
  • ABB NGC8206 natural gas chromatograph troubleshooting and maintenance
  • ABB AO2040-CU Ex Explosion proof Analyzer Troubleshooting
  • ABB PFEA113 Tension Controller Troubleshooting Guide
  • ABB PFEA111/112/122 Tension Controller Troubleshooting Guide
  • ABB LS4000 laser analyzer
  • ABB SPAU 341 C Voltage Regulator Troubleshooting Guide
  • Analysis and Fault Diagnosis of ABB V-Contact VSC Medium Voltage Contactor
  • ABB UNITOL 1020 Compact Digital Excitation Regulator AVR Replacement and Troubleshooting
  • ABB UNITROL 1000 excitation system replacement and troubleshooting
  • ABB SYNC HROTACT 5 synchronization module troubleshooting and replacement
  • ABB SYNC HROTACT 5 Synchronization Device Replacement and Troubleshooting Guide
  • ABB Symphony Plus Module Replacement and Upgrade Guide
  • ABB S900 I/O Hazardous Area Deployment and Maintenance
  • ABB System 800xA Operations and Troubleshooting
  • ABB PCS6000 Troubleshooting and Module Replacement Guide
  • ABB PCS 8000 pumped storage excitation
  • ABB Procontrol P13 Bus Coupling Upgrade Guide
  • ABB NextMove ESB-2 Fault Diagnosis and Configuration Practice
  • ABB MEGADRIVE-LCI Maintenance and Selection Practice
  • ABB MEGADRIVE LCI Transmission Vibration Suppression
  • ABB MEGADRIVE LCI Water Cooling Troubleshooting and Maintenance Guide
  • Practical Maintenance and Common Troubleshooting of ABB DCS880
  • ABB SDCS-IOB-3 Replacement and Troubleshooting
  • ALSTOM MAE99-04 Serial Interface Terminal Panel Maintenance and Troubleshooting
  • Installation and Maintenance of ALSTOM ALSPA MV3000 Handheld Operator
  • Maintenance and commissioning of ABB KPM KB2 paper breakage detector
  • Maintenance and troubleshooting of ABB SCC-K converter
  • ABB SCC Gas Preprocessing System Maintenance and Selection Guide
  • ABB NGC8209 gas chromatograph maintenance
  • Maintenance and troubleshooting of ABB DCS DC speed controller
  • ABB ASTAT Crane Controller Maintenance and Debugging Guide
  • ABB ACS800 TIM foil IGBT
  • ABB LS25 laser analyzer troubleshooting
  • ABB REM54 motor terminal troubleshooting
  • ABB REL670 distance protection and troubleshooting
  • ABB SUE3000 switching device troubleshooting
  • ABB REF630 feeder protection
  • ABB REF620 (Relion 620 series) feeder protection and measurement device
  • ABB E1B-A Circuit Breaker
  • ABB FCU400-IR temperature measurement system troubleshooting
  • ABB TZIDC-200 locator configuration and troubleshooting
  • ABB DHH805-A Handheld Operator Configuration and Activation Guide
  • ABB SACO 16D1 alarm device replacement and troubleshooting
  • ABB 5SHY3545L0016 IGCT module replacement guide
  • ABB S600 I/O Module Replacement and Troubleshooting Guide
  • ABB NextMove e100 motion controller troubleshooting guide
  • Rockwell PowerFlex 700 Inverter Replacement and Troubleshooting Guide
  • Allen Bradley 1762-OW16 Output Module
  • Allen Bradley IntelliVAC 1503VC Series E Control Module
  • Allen‑Bradley IntelliVAC ™ 1503VC contactor control module
  • Woodward SOGAV 250 solenoid valve drives gas intake valve for troubleshooting
  • Woodward easyYgen-3500XT-P1 obstacle removal
  • Woodward CPC-II electro-hydraulic current pressure converter
  • UniOP ePALM10 Handheld HMI
  • TMEIC TMdrive-30 frequency converter
  • TEWS TVME200 Carrier Board Configuration and Troubleshooting Guide
  • TDK Alpha 400 Power Troubleshooting Guide
  • STUCKE SYMAP relay
  • Deployment and troubleshooting of Softing CAN-AC2-PCI interface card
  • Installation, Maintenance, and Troubleshooting of Siemens C7-623/624
  • Foxboro Compact 200 Series 16 Slot Bottom Plate Deployment and Maintenance Guide
  • Foxboro 84F/84W Vortex Flow Meter Selection and Debugging Guide
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller
  • DATA PATTERNS DP-VME-5114 Dual PMC Carrier Board Integration and Troubleshooting
  • CMZ SVM1608 Intelligent Servo Driver
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide
  • SUMITOMO ELECTRIC AC1135U Small Parts Turning Application Guide
  • SUMITOMO ELECTRIC AC1030U Precision Machining Selection and Practice for Small Parts
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection
  • BENDER RCMA475LY Residual Current Monitoring