Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • ABB TMM-700 Trip Monitor
    ❤ Add to collection
  • ABB TMM-700 Trip Monitor

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    TMM-700 Trip Monitor
    • ¥5767.00
      ¥11313.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.000KG
    • Quantity:
    • (Inventory: 2)
Description
TMM-700 Trip Monitor

ABB TMM-700 Trip Monitor

Basic Information

Series:ABB Bailey Infi 90.

Function Overview: It is mainly used to monitor and protect the equipment and system in industrial process, when abnormal situation is detected, it can trigger the tripping action in time to prevent the equipment from being damaged or to protect the safety of personnel. For example, in the power system, it can monitor the current, voltage and other parameters, once there is an overload, short-circuit and other faults, it will quickly send out a trip signal to cut off the circuit, to protect electrical equipment from damage.

Technical Parameters

Input Signal Type: Usually it can accept various types of input signals, such as analogue input signals, including 4-20mA current signals, 0-10V voltage signals, etc., in order to connect with various sensors or transmitters to obtain the measured values of different physical quantities; it may also support digital input signals, which are used to receive status signals, alarm signals, etc., from other equipments or systems.

Measurement accuracy: It has high measurement accuracy to ensure that it can accurately monitor the small changes of the measured parameters. Generally speaking, the current measurement accuracy can reach ±0.5% or higher, and the voltage measurement accuracy can also reach a similar level, so as to provide a reliable basis for tripping judgement.

Response time: The response time is fast, and it can detect the fault and trigger the tripping action in a short time. Usually the response time in milliseconds or even faster, which is crucial for the rapid protection of equipment and systems, can effectively reduce the degree of damage to the equipment fault.

Output Signal: With a variety of output signal interfaces, common relay output, which can be used to directly control the tripping operation of circuit breakers and other equipment; there may also be digital communication interfaces, such as RS-485, etc., in order to communicate with the host computer or other control equipment for data communication, and to transmit the monitored information and tripping status to the relevant equipment, to achieve remote monitoring and management.

Application Fields

Power system: Widely used in power plants, substations and other places to monitor the operation status of generators, transformers, transmission lines and other equipment. For example, in generator protection, TMM-700 can monitor stator current, rotor current, voltage and other parameters, and when there are internal faults, overloads, undervoltage and other abnormalities, it can trip the generator in time to protect the generator from damage and ensure the stable operation of the power system.

Industrial automation production line: In various industrial production processes, such as chemical, metallurgy, machinery manufacturing and other industries, automation production line, used to monitor the working status of motors, inverters, drives and other equipment. Once the equipment malfunction or abnormal operation, such as motor overload, short circuit, etc., TMM-700 can quickly trip to avoid the expansion of the fault, reduce equipment maintenance costs and production downtime.

Transportation: It is also used in rail transit and electric vehicle charging stations. For example, in the traction power supply system of rail transit, TMM-700 can be used to monitor the contact network current, voltage and other parameters to ensure the safe and reliable operation of the power supply system; in electric vehicle charging stations, it can be used to monitor the current and voltage of charging equipment to prevent overcharging, overcurrent and other conditions from causing damage to electric vehicles and charging equipment.

Maintenance

Regular Inspection: Regularly check the appearance of TMM-700 Trip Monitor for signs of damage, looseness or corrosion. At the same time, check whether the connecting cables are firm and the plug and socket are in good contact to ensure the reliability of signal transmission. If any problems are found, the damaged parts should be dealt with or replaced in time.

Calibration and verification: To ensure the accuracy of the measurement and the trip function, the module needs to be calibrated and verified periodically. The calibration process should be carried out in accordance with the relevant ABB technical specifications and operating manuals, using professional calibration equipment and tools to calibrate and verify the input and output signals. It is generally recommended to carry out calibration every year or every two years, the specific period can be determined according to the use of the equipment environment and frequency of operation and other factors.

Software upgrading: ABB may upgrade the control software of TMM-700 with the continuous development of technology and changes in application requirements. Users should pay attention to the official information of ABB, download and install the latest software version in time to ensure that the module has the latest functions and performance, and at the same time improve the safety and stability of the system.

Troubleshooting: When the TMM-700 has a fault, you can first get the fault information through the indicator light or communication interface on the module, and make a preliminary judgement on the cause of the fault. Common faults include abnormal input and output signals, inaccurate tripping action, communication faults and so on. For different fault phenomena, adopt corresponding troubleshooting and processing methods, such as checking the signal source, replacing the faulty module, checking the communication line, etc. If you can not solve the problem by yourself, you should contact ABB's technical support staff or professional maintenance personnel for maintenance.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Advantest R6144 Programmable DC Voltage/Current Source (Calibration Source) Calibration and Maintenance
  • Aerotech UNIDEX 100/U100i single axis motion controller
  • Aerotech Ndrive MP Ultra Compact PWM Digital Servo Driver
  • Aerotech Ndrive HPe 10/20/30 High Performance PWM Digital Servo Drive
  • Aerotech Ndrive HLe maintenance replacement
  • Aerotech Ndrive CP maintenance replacement
  • Aerotech Ndrive Linear Drive Selection
  • Aerotech NDrive HL linear drive maintenance replacement
  • Aerotech NDrive HP 10/20/30 Maintenance and Replacement
  • Aerotech NDrive CP10 Servo Drive Guide
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications
  • Bonfiglioli 300 series reducer installation, maintenance, and troubleshooting guide
  • Selection and integration guide for Bonfiglioli R3 series planetary gearboxes in primary crushing equipment
  • Bonfiglioli C-series ATEX gearbox selection and explosion-proof application guide
  • Bonfiglioli Vectron EM-ENC-05 Full Function Expansion Module Integration Guide
  • Bonfiglioli Vectron EM-ENC-04 Multi functional Expansion Module Complete Configuration Guide
  • Bonfiglioli Vectron EM-ENC-03 Second Encoder Interface and System Bus Expansion Guide
  • Bonfiglioli Vectron EM-ENC-02 Expansion Module Integration and Encoder Interface Guide
  • Bonfiglioli Vectron CM-CAN CANopen Communication Configuration and DS402 Control Guide
  • Bonfiglioli Vectron EM-SYS System Bus Networking and Virtual Link Configuration Guide
  • Bonfiglioli Vectron CM-PDP Profibus DP Configuration and Debugging Guide