Description

The Net Sure731 system can be configured in four main ways:

1. Single AC input, no user AC output circuit breaker;

2. Single AC input, user AC output circuit breaker;

3. Dual AC input, manual switching;

4. Dual AC input, automatic switching (maximum configuration); In addition, in general, in the DC distribution unit of the power system, the load branch and the battery protection branch are connected by short-circuit bars, and the system does not have the load power-off function. If the system needs to provide the load power-off function, you need to select a load power-off unit instead of a short-circuit bar. The internal structure of the power system is based on the strongest configuration, and other configurations only remove certain components. In maximum configuration.

Net Sure731 48V600A intelligent high frequency switching power supply system is suitable for base stations, small and medium capacity exchanges, satellite communications, data communications and other power grid fluctuation range is very wide occasions. Net Sure731 48V600A Intelligent High Frequency Switching Power system is easy to operate, install and maintain. The AC input and output cables and DC input and output cables can enter and exit freely from the top or bottom of the cabinet.


Its main features are:

 rectifier module using active power factor compensation technology, power factor value of 0.99.

 The AC input voltage has a wide normal operating range. For the system without automatic switching, the AC input voltage can be 85~290V. For the system with automatic switching, the voltage range can be 125~285V.

 Rectifier module Ultra-low radiation. With advanced electromagnetic compatibility design, the rectifier module can meet the requirements of CE, NEBS, YD/T983 and other domestic and foreign standards. The conduction and radiation of the rectifier module can meet the requirements of Class B.  Rectifier module safety design in line with UL, CE, NEBS standards.

 The module has high power density.

 The rectifier module uses the non-damaging hot swap technology. The replacement time is less than 1 minute.

 The rectifier module has output overvoltage hardware protection and output overvoltage software protection. There are two options for software overvoltage protection: primary overvoltage locking mode and secondary overvoltage locking mode.

 Perfect battery management. It has the function of battery low voltage protection and load power-off (optional), which can realize temperature compensation, automatic voltage regulation, stepless current limiting, battery capacity calculation, online battery test and other functions.

 Up to 200 historical alarm records can be recorded. Up to 10 groups of battery test data can be recorded.

 Network design, provides RS232, Modem, dry contact and other communication interfaces, flexible networking, can realize remote monitoring, unattended.

 Perfect lightning protection design for AC and DC side.  Complete fault protection and fault alarm

 The power system cabinet can be installed against a wall and operated and maintained on the front of the cabinet.

 is equipped with an optional cabinet cover and air filter.

The working principle of the system is that the mains enters the rectifier module through the AC distribution branch, and the -48V DC rectified by each rectifier module enters the DC distribution through the tandem connection, and is provided to the communication equipment in multiple channels. Under normal circumstances, the system runs in parallel floating charging state, that is, the rectifier module, load, and battery work in parallel. The rectifier module not only supplies power to the communication equipment, but also provides floating charging flow for the battery. When the mains power is off, the rectifier module stops working, and the battery supplies power to the communication device to maintain the normal operation of the communication device. After the mains is restored, the rectifier module supplies power to the communication device and charges the battery to replenish the consumed power. The monitoring module uses centralized monitoring to manage AC power distribution and DC power distribution, and receives the operating information of the rectifier module through CAN communication and controls it accordingly. The monitoring module can also be connected to the local computer through RS232, and can be connected to the monitoring center through the Modem or other transmission resources (such as the official channel, etc.) to realize the centralized monitoring network of the power system.

The main function of the system

Net Sure731 48V600A Intelligent High frequency Switching Power Supply system has the following main functions:

 Excellent lightning protection design

 AC input overvoltage protection

 Load power-off and Battery Low Voltage protection (LLVD+BLVD)

 Fault alarm and protection

 Provides multi-channel and multi-specification DC output

 monitoring and four remote function

Ac input overvoltage protection

The Net Sure731 48V600A system has complete input overvoltage protection. For systems without automatic switching, the overvoltage protection is referred to the Overvoltage protection of the rectifier module in Chapter 2. For the automatic switching system with AC contactor, when the AC voltage reaches a certain set overvoltage point, the AC contactor will be automatically disconnected and the AC will be automatically cut off to protect the rectifier module and subsequent user AC equipment. When the AC input voltage returns to normal, the AC contactor can automatically close, and the rectifier module and other user AC equipment can automatically return to normal work.


Load power-off and battery low voltage protection

When the AC power is off and the rectifier module has no DC output, the battery starts to discharge. Set when voltage drops to undervoltage

When the fixed point is 45.0V (adjustable), the system will issue sound and light alarm. When the battery voltage continues to drop below the load

When the electric operating point is 44.0V (adjustable), the load power off contactor is disconnected and connected to the load power off branch

General communication loads (such as local switches) will be cut off from the power supply, and critical loads (such as transmission devices)

Standby) power supply can thus be extended. As the battery discharge process continues, if the battery discharge to termination

Voltage battery protection action point 43.2V (adjustable), the battery protection contactor will be disconnected, the battery discharge process will be terminated, and the power supply of all communication loads will be suspended, so as to avoid battery damage due to overdischarge. When an AC call comes in and the rectifier module outputs a normal DC voltage, the load is powered off and the battery contactor automatically closes, and the system returns to normal operation.

Functions such as load power-off and battery low voltage protection can be manually controlled.

Fault alarm and protection

Net Sure731 48V600A power supply system with complete fault warning and protection. The monitoring module can collect system data in real time, and detect the status of load output fuse, battery fuse, and II/C level surge protection device. You can flexibly set alarm levels for system faults, such as AC input overvoltage or undervoltage, DC output overvoltage or undervoltage, and module faults. You can also flexibly configure alarm types indicated by alarm dry nodes.


Choose Xiamen control Smith after sale worry

Excellent product quality

Only cooperate with manufacturers of first-line brands in the industry

Imports/Products

Good pre-sale service

Communicated with customers repeatedly about product model, quality, price and delivery date

Work with the customer to determine the best solution

Address user concerns in advance

Business execution in place

Ordered products delivered on time

Make perfect delivery plan to ensure the time limit

Assist users to handle the acceptance procedures

Perfect after-sales service

During the warranty period, problems will only be replaced and not repaired

Never put a problem on the back of your head

Service hotline 7x24 hours service


Solemn promise

1. All the items sold by the company, module card parts, etc., the quality problems arising from normal use during the warranty period are replaced free of charge, and there is no evasion.

2. For materials and equipment that have not been discontinued beyond the warranty period, only the cost of relevant parts will be charged for quality problems.

3. Provide replacement models and equipment replacement process services for discontinued materials and equipment.

4. Customers have purchased materials and equipment, lifetime free upgrade system software, related technical information provided free of charge.

5. Visit the use of materials purchased by customers from time to time, and solve any problems in time.

6. The company hotline provides 24-hour service, and the questions raised by customers are answered within 1 hour.

7. Not done, the company spirit of "thoughtful service, responsible to the end" attitude, from the customer's point of view to solve the problem, with serious and rigorous enterprise style, dedicated to each customer service.



  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • DEIF TCM-2 thyristor control module: Wind power cut in control engineering guide
  • DEIF MVR-200 Medium Voltage Relay: Installation and Wiring Engineering Guide
  • DEIF MDR-2 Differential Relay: Engineering Guide for Generator Differential Protection
  • DEIF Delomatic 3 AOM: Engineering Guide for Analog Output Modules
  • DEIF AGI 400 Graphic Interface: Ship and Industrial HMI Solution
  • DEIF BRW-1 Marine Instruments: Installation and Calibration Guide for Offshore Bridge Indicators
  • DEIF AGC 200 Controller: Quick Deployment and Configuration Guide for Generator Sets
  • DEIF AGC-2 Controller: The Ultimate Guide to Automatic Control and Protection of Generator Sets
  • ABB SPA-ZC400 Gateway: REM54x Access to IEC 61850 Ultimate Engineering Guide
  • ABB REM 543/545 Terminal
  • Modular Architecture Analysis of DEIF PPU 300 Ship Generator Controller
  • DEIF DM-4 Marine&Offshore Ship Power Management System
  • Detailed Explanation of DEIF Delomatic Generator Control System Architecture
  • DEIF AGC-4 Mk II Generator Controller Depth Configuration Guide
  • DEIF AGC-4 Generator Controller Configuration and Debugging Guide
  • DEIF PPM Power Management System Operation and Troubleshooting
  • Installation and wiring of DEIF Multi line 2
  • Practical configuration and maintenance of Beckwith M-6280 capacitor bank controller
  • Beckwith M-3311 Transformer Protection Relay Setting and Engineering Application
  • Beckwith M-3311A Transformer Protection Relay Configuration and Optimization Guide
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit
  • Installation and I/O configuration of DEIF PPM-3 power management module
  • Beckwith M-3520 Interconnection Protection Relay
  • Beckwith M-3430 Generator Protection Relay
  • Beckwith M-2293B adapter panel replacement GE regulator guide
  • Selection and Networking of Beckwith M-2001C Digital Voltage Regulating Controller
  • Beckwith M-2001B Digital Voltage Regulating Controller
  • Beckwith M-0388/M-0389 Synchronous Inspection Relay Application Guide
  • Beckwith M-0193B Synchronizer Debugging and System Integration Guide
  • Beckwith M-0115A Parallel Balance Module Debugging Guide
  • Beckwith M-0067E On Load Voltage Regulating Controller Selection and Debugging Guide
  • Debugging and Fault Handling of Beckwith M-4272 Digital Busbar Conversion System
  • Beckwith M-3311A Transformer Protection Relay Debugging Guide
  • Beckwith M-3425A Generator Protection Relay Debugging Guide
  • Setting and troubleshooting of Basler BE1-27/59 voltage relay
  • Debugging and troubleshooting of Basler AVC63-12/AVC125-10 voltage regulator
  • Basler L301kc Line Array Camera Technology and Troubleshooting
  • Selection and Debugging of Basler CBS 212A Current Boosting System
  • Selection and commissioning of Basler BE3-25 synchronous inspection relay
  • Basler BE1-32R/32O/U Direction Power Relay Setting and Testing Guide
  • Basler PRS 250 Synchronous Relay Maintenance and Replacement Guide
  • Basler piA2400-17gc Industrial Camera Replacement and Optimization Guide
  • Basler BE1-11g Generator Protection System
  • Basler VR63-4C/UL Voltage Regulator
  • Basler BE1-DFPR feeder protection relay
  • Basler CBS 310/320 Current Boosting System
  • Basler UFOV 250A/260A protection module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F Regulator
  • Basler DECS-400 excitation system
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection
  • Basler SSR Static Voltage Regulator: A Complete Guide to Debugging and Troubleshooting
  • Basler SR4A/SR8A Voltage Regulator: Detailed Debugging and Troubleshooting Explanation
  • Basler BE2000E Voltage Regulator: Replacement and Application Details
  • Basler DECS-2100 Excitation System: Modular Upgrade and Engineering Application
  • Basler BE1-851 Overcurrent Protection System: A Complete Guide to Professional Debugging and Troubleshooting
  • Basler APR 63-5 Voltage Regulator: Professional Debugging and Troubleshooting Guide for Industrial Generator Excitation Systems
  • Basler BE1-FLEX Protection System: A Complete Guide to Professional Installation, Configuration, and Troubleshooting
  • Debugging and Testing of Basler BE1-700 Relay
  • Basler BE1-87B busbar differential setting test
  • Basler BE1-40Q demagnetization relay setting test
  • Basler BE1-60 Voltage Balance Relay Setting Test
  • Basler BE1-47N Relay Field Setting and Testing Guide
  • Basler BE1-81O/U Frequency Relay: On site Debugging and Protection Configuration Guide
  • Basler BE1-11f Feedline Protection System Debugging and Troubleshooting Guide
  • Basler DECS-250 Excitation System: Installation, Configuration, and Troubleshooting Practice Guide
  • Basler DECS-100 Digital Excitation System Debugging Guide
  • Application Guide for Basler BE1-BPR Circuit Breaker Protection Relay
  • Basler BE1-50/51B-255 Replacement CO Relay Guide
  • Basler BE1-25 synchronous inspection relay principle and testing
  • Basler BE1-51 Time Overcurrent Relay Debugging Guide
  • Practical Guide to Basler DECS-300 Digital Excitation System
  • Mitsubishi FX Series PLC Data Communication Practical Manual
  • Selection of Hirschmann cSCALE S6/C8 Mobile Safety Controller
  • Hirschmann OZD Profi G12D repeater explosion-proof installation configuration
  • Hirschmann OCTOPUS OS20/24 Switch Installation Power Supply
  • Hirschmann RS20/30/40 Switch Selection and PoE Deployment
  • Hirschmann EAGLE One Firewall Installation and Configuration Guide
  • Hirschmann MACH102 Switch Installation and Power Supply Guide
  • Hirschmann MICE MS20/MS30 Installation and DIP Configuration
  • Hirschmann BOBCAT BRS Switch Installation and Power Supply Guide
  • Hirschmann RSB20 Switch Deployment and Redundant Configuration
  • Hirschmann RS20 Basic Switch Installation and Debugging Guide
  • BECKHOFF EP20xx/EP28xx Output Module Installation and Debugging Guide
  • BECKHOFF EL5102 Encoder Terminal Debugging and Troubleshooting
  • BECKHOFF CU8803 Launch Box Installation and Explosion proof Guide
  • BECKHOFF CU20xx/CU22xx Switch Installation and Troubleshooting
  • BECKHOFF AMP8000 Servo Drive Installation and Debugging Manual
  • BECKHOFF EL2911 Safety Feed Terminal Debugging Guide
  • BECKHOFF EL600x/EL602x Serial Port Module Debugging Manual
  • BECKHOFF CP6700 Panel PC Installation and Maintenance Manual
  • BECKHOFF CP70xx panel maintenance and troubleshooting
  • BECKHOFF CP29xx Panel Installation and Troubleshooting
  • Beckhoff C6650-0060 Industrial Control Computer Hardware Architecture and RAID Data Security
  • Beckhoff BK1120/BK1250 EtherCAT Coupling Debugging and KL Terminal Parameterization Complete Guide
  • Beckhoff CX20x0 Embedded Controller Hardware Maintenance and Troubleshooting Complete Manual
  • Beckhoff CP77xx Panel PC Hardware Maintenance and Troubleshooting Complete Guide
  • Beckhoff EL41xx Analog Output Terminal Deep Analysis: Parameter Configuration, Fault Diagnosis, and Firmware Compatibility Guide
  • Beckhoff C63xx industrial computer power supply and shutdown configuration
  • Beckhoff C6920 Industrial Control Computer Selection and Expansion Guide
  • Beckhoff CU8800 USB extender diagnostic guide
  • Beckhoff AX2000 Shutdown Braking and Debugging
  • Beckhoff AX8000 servo installation fuse selection
  • Beckhoff CP27xx Multi finger Touch PC Maintenance
  • Beckhoff CP69xx long-distance transmission and installation
  • Beckhoff CP60xx remote deployment and maintenance
  • Beckhoff CP72xx Installation and Maintenance Complete Manual
  • Beckhoff CP78xx Installation and Troubleshooting Guide
  • Beckhoff CP39xx Control Panel
  • Beckhoff CX8110 Embedded PC
  • Beckhoff CX50x0 series DIN rail embedded industrial PC
  • Beckhoff CP62xx panel PC
  • BECKHOFF C6030 Industrial Control Computer
  • UniOP ePAD32B/ePAD33B/ePAD33BT Industrial HMI
  • UniOP ePAD05/06 Human Computer Interface
  • UniOP ePAD03/04 Human Computer Interface
  • UniOP BKDR-46-0045 Human Machine Interface
  • UniOP BKDR-16 human-machine interface
  • Beckwith M-3425A Relay Guide
  • Basler DECS-200-2L excitation system
  • Basler DECS-250 Excitation System Debugging Guide
  • HA-800A Servo Drive Debugging Guide
  • JUMO dTRANS p35 Manual