Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • Emerson 731 Series 48V600A/R48-3000E3 power supply
    ❤ Add to collection
  • Emerson 731 Series 48V600A/R48-3000E3 power supply

    • ¥36487.00
      ¥34646.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:0.000KG
    • Quantity:
    • (Inventory: 50)
Description

The Net Sure731 system can be configured in four main ways:

1. Single AC input, no user AC output circuit breaker;

2. Single AC input, user AC output circuit breaker;

3. Dual AC input, manual switching;

4. Dual AC input, automatic switching (maximum configuration); In addition, in general, in the DC distribution unit of the power system, the load branch and the battery protection branch are connected by short-circuit bars, and the system does not have the load power-off function. If the system needs to provide the load power-off function, you need to select a load power-off unit instead of a short-circuit bar. The internal structure of the power system is based on the strongest configuration, and other configurations only remove certain components. In maximum configuration.

Net Sure731 48V600A intelligent high frequency switching power supply system is suitable for base stations, small and medium capacity exchanges, satellite communications, data communications and other power grid fluctuation range is very wide occasions. Net Sure731 48V600A Intelligent High Frequency Switching Power system is easy to operate, install and maintain. The AC input and output cables and DC input and output cables can enter and exit freely from the top or bottom of the cabinet.


Its main features are:

 rectifier module using active power factor compensation technology, power factor value of 0.99.

 The AC input voltage has a wide normal operating range. For the system without automatic switching, the AC input voltage can be 85~290V. For the system with automatic switching, the voltage range can be 125~285V.

 Rectifier module Ultra-low radiation. With advanced electromagnetic compatibility design, the rectifier module can meet the requirements of CE, NEBS, YD/T983 and other domestic and foreign standards. The conduction and radiation of the rectifier module can meet the requirements of Class B.  Rectifier module safety design in line with UL, CE, NEBS standards.

 The module has high power density.

 The rectifier module uses the non-damaging hot swap technology. The replacement time is less than 1 minute.

 The rectifier module has output overvoltage hardware protection and output overvoltage software protection. There are two options for software overvoltage protection: primary overvoltage locking mode and secondary overvoltage locking mode.

 Perfect battery management. It has the function of battery low voltage protection and load power-off (optional), which can realize temperature compensation, automatic voltage regulation, stepless current limiting, battery capacity calculation, online battery test and other functions.

 Up to 200 historical alarm records can be recorded. Up to 10 groups of battery test data can be recorded.

 Network design, provides RS232, Modem, dry contact and other communication interfaces, flexible networking, can realize remote monitoring, unattended.

 Perfect lightning protection design for AC and DC side.  Complete fault protection and fault alarm

 The power system cabinet can be installed against a wall and operated and maintained on the front of the cabinet.

 is equipped with an optional cabinet cover and air filter.

The working principle of the system is that the mains enters the rectifier module through the AC distribution branch, and the -48V DC rectified by each rectifier module enters the DC distribution through the tandem connection, and is provided to the communication equipment in multiple channels. Under normal circumstances, the system runs in parallel floating charging state, that is, the rectifier module, load, and battery work in parallel. The rectifier module not only supplies power to the communication equipment, but also provides floating charging flow for the battery. When the mains power is off, the rectifier module stops working, and the battery supplies power to the communication device to maintain the normal operation of the communication device. After the mains is restored, the rectifier module supplies power to the communication device and charges the battery to replenish the consumed power. The monitoring module uses centralized monitoring to manage AC power distribution and DC power distribution, and receives the operating information of the rectifier module through CAN communication and controls it accordingly. The monitoring module can also be connected to the local computer through RS232, and can be connected to the monitoring center through the Modem or other transmission resources (such as the official channel, etc.) to realize the centralized monitoring network of the power system.

The main function of the system

Net Sure731 48V600A Intelligent High frequency Switching Power Supply system has the following main functions:

 Excellent lightning protection design

 AC input overvoltage protection

 Load power-off and Battery Low Voltage protection (LLVD+BLVD)

 Fault alarm and protection

 Provides multi-channel and multi-specification DC output

 monitoring and four remote function

Ac input overvoltage protection

The Net Sure731 48V600A system has complete input overvoltage protection. For systems without automatic switching, the overvoltage protection is referred to the Overvoltage protection of the rectifier module in Chapter 2. For the automatic switching system with AC contactor, when the AC voltage reaches a certain set overvoltage point, the AC contactor will be automatically disconnected and the AC will be automatically cut off to protect the rectifier module and subsequent user AC equipment. When the AC input voltage returns to normal, the AC contactor can automatically close, and the rectifier module and other user AC equipment can automatically return to normal work.


Load power-off and battery low voltage protection

When the AC power is off and the rectifier module has no DC output, the battery starts to discharge. Set when voltage drops to undervoltage

When the fixed point is 45.0V (adjustable), the system will issue sound and light alarm. When the battery voltage continues to drop below the load

When the electric operating point is 44.0V (adjustable), the load power off contactor is disconnected and connected to the load power off branch

General communication loads (such as local switches) will be cut off from the power supply, and critical loads (such as transmission devices)

Standby) power supply can thus be extended. As the battery discharge process continues, if the battery discharge to termination

Voltage battery protection action point 43.2V (adjustable), the battery protection contactor will be disconnected, the battery discharge process will be terminated, and the power supply of all communication loads will be suspended, so as to avoid battery damage due to overdischarge. When an AC call comes in and the rectifier module outputs a normal DC voltage, the load is powered off and the battery contactor automatically closes, and the system returns to normal operation.

Functions such as load power-off and battery low voltage protection can be manually controlled.

Fault alarm and protection

Net Sure731 48V600A power supply system with complete fault warning and protection. The monitoring module can collect system data in real time, and detect the status of load output fuse, battery fuse, and II/C level surge protection device. You can flexibly set alarm levels for system faults, such as AC input overvoltage or undervoltage, DC output overvoltage or undervoltage, and module faults. You can also flexibly configure alarm types indicated by alarm dry nodes.


Choose Xiamen control Smith after sale worry

Excellent product quality

Only cooperate with manufacturers of first-line brands in the industry

Imports/Products

Good pre-sale service

Communicated with customers repeatedly about product model, quality, price and delivery date

Work with the customer to determine the best solution

Address user concerns in advance

Business execution in place

Ordered products delivered on time

Make perfect delivery plan to ensure the time limit

Assist users to handle the acceptance procedures

Perfect after-sales service

During the warranty period, problems will only be replaced and not repaired

Never put a problem on the back of your head

Service hotline 7x24 hours service


Solemn promise

1. All the items sold by the company, module card parts, etc., the quality problems arising from normal use during the warranty period are replaced free of charge, and there is no evasion.

2. For materials and equipment that have not been discontinued beyond the warranty period, only the cost of relevant parts will be charged for quality problems.

3. Provide replacement models and equipment replacement process services for discontinued materials and equipment.

4. Customers have purchased materials and equipment, lifetime free upgrade system software, related technical information provided free of charge.

5. Visit the use of materials purchased by customers from time to time, and solve any problems in time.

6. The company hotline provides 24-hour service, and the questions raised by customers are answered within 1 hour.

7. Not done, the company spirit of "thoughtful service, responsible to the end" attitude, from the customer's point of view to solve the problem, with serious and rigorous enterprise style, dedicated to each customer service.



  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Yokogawa AIP830 Single Circuit Operation Keyboard
  • Yokogawa RAMC flowmeter selection and troubleshooting
  • YASKAWA GA500 frequency converter troubleshooting
  • TRACO TIS600 power supply
  • Sigmatek ETV-0851 Control Panel Troubleshooting
  • Allen Bradley Quest AN-X2-AB-DHRIO Remote I/O Adapter Integration and Troubleshooting
  • Meggitt RPS6U power supply
  • Kongsberg RCU500 Controller Integration and Fault Diagnosis Guide
  • KBAC series frequency converter installation and fault diagnosis guide
  • EXOR effectiveness View eV058 series HMI industrial panel
  • Emerson OCR3000 Controller Troubleshooting Guide
  • Emerson Ovation OCR1100 Controller Maintenance and Troubleshooting
  • Elmo G-TUB30 Driver Troubleshooting Guide
  • Troubleshooting and Optimization of Basler A400 Series Camera
  • Troubleshooting and Maintenance of Automated Logic I/O Expansion Module
  • Troubleshooting and Maintenance of Aerotech UNIDEX 100 Controller
  • ADVANEST R6144 calibration source troubleshooting
  • Troubleshooting and Calibration of ABB Millmate Tension Gauge
  • ABB NGC8206 natural gas chromatograph troubleshooting and maintenance
  • ABB AO2040-CU Ex Explosion proof Analyzer Troubleshooting
  • ABB PFEA113 Tension Controller Troubleshooting Guide
  • ABB PFEA111/112/122 Tension Controller Troubleshooting Guide
  • ABB LS4000 laser analyzer
  • ABB SPAU 341 C Voltage Regulator Troubleshooting Guide
  • Analysis and Fault Diagnosis of ABB V-Contact VSC Medium Voltage Contactor
  • ABB UNITOL 1020 Compact Digital Excitation Regulator AVR Replacement and Troubleshooting
  • ABB UNITROL 1000 excitation system replacement and troubleshooting
  • ABB SYNC HROTACT 5 synchronization module troubleshooting and replacement
  • ABB SYNC HROTACT 5 Synchronization Device Replacement and Troubleshooting Guide
  • ABB Symphony Plus Module Replacement and Upgrade Guide
  • ABB S900 I/O Hazardous Area Deployment and Maintenance
  • ABB System 800xA Operations and Troubleshooting
  • ABB PCS6000 Troubleshooting and Module Replacement Guide
  • ABB PCS 8000 pumped storage excitation
  • ABB Procontrol P13 Bus Coupling Upgrade Guide
  • ABB NextMove ESB-2 Fault Diagnosis and Configuration Practice
  • ABB MEGADRIVE-LCI Maintenance and Selection Practice
  • ABB MEGADRIVE LCI Transmission Vibration Suppression
  • ABB MEGADRIVE LCI Water Cooling Troubleshooting and Maintenance Guide
  • Practical Maintenance and Common Troubleshooting of ABB DCS880
  • ABB SDCS-IOB-3 Replacement and Troubleshooting
  • ALSTOM MAE99-04 Serial Interface Terminal Panel Maintenance and Troubleshooting
  • Installation and Maintenance of ALSTOM ALSPA MV3000 Handheld Operator
  • Maintenance and commissioning of ABB KPM KB2 paper breakage detector
  • Maintenance and troubleshooting of ABB SCC-K converter
  • ABB SCC Gas Preprocessing System Maintenance and Selection Guide
  • ABB NGC8209 gas chromatograph maintenance
  • Maintenance and troubleshooting of ABB DCS DC speed controller
  • ABB ASTAT Crane Controller Maintenance and Debugging Guide
  • ABB ACS800 TIM foil IGBT
  • ABB LS25 laser analyzer troubleshooting
  • ABB REM54 motor terminal troubleshooting
  • ABB REL670 distance protection and troubleshooting
  • ABB SUE3000 switching device troubleshooting
  • ABB REF630 feeder protection
  • ABB REF620 (Relion 620 series) feeder protection and measurement device
  • ABB E1B-A Circuit Breaker
  • ABB FCU400-IR temperature measurement system troubleshooting
  • ABB TZIDC-200 locator configuration and troubleshooting
  • ABB DHH805-A Handheld Operator Configuration and Activation Guide
  • ABB SACO 16D1 alarm device replacement and troubleshooting
  • ABB 5SHY3545L0016 IGCT module replacement guide
  • ABB S600 I/O Module Replacement and Troubleshooting Guide
  • ABB NextMove e100 motion controller troubleshooting guide
  • Rockwell PowerFlex 700 Inverter Replacement and Troubleshooting Guide
  • Allen Bradley 1762-OW16 Output Module
  • Allen Bradley IntelliVAC 1503VC Series E Control Module
  • Allen‑Bradley IntelliVAC ™ 1503VC contactor control module
  • Woodward SOGAV 250 solenoid valve drives gas intake valve for troubleshooting
  • Woodward easyYgen-3500XT-P1 obstacle removal
  • Woodward CPC-II electro-hydraulic current pressure converter
  • UniOP ePALM10 Handheld HMI
  • TMEIC TMdrive-30 frequency converter
  • TEWS TVME200 Carrier Board Configuration and Troubleshooting Guide
  • TDK Alpha 400 Power Troubleshooting Guide
  • STUCKE SYMAP relay
  • Deployment and troubleshooting of Softing CAN-AC2-PCI interface card
  • Installation, Maintenance, and Troubleshooting of Siemens C7-623/624
  • Foxboro Compact 200 Series 16 Slot Bottom Plate Deployment and Maintenance Guide
  • Foxboro 84F/84W Vortex Flow Meter Selection and Debugging Guide
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller
  • DATA PATTERNS DP-VME-5114 Dual PMC Carrier Board Integration and Troubleshooting
  • CMZ SVM1608 Intelligent Servo Driver
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide
  • SUMITOMO ELECTRIC AC1135U Small Parts Turning Application Guide
  • SUMITOMO ELECTRIC AC1030U Precision Machining Selection and Practice for Small Parts
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection
  • BENDER RCMA475LY Residual Current Monitoring
  • BENDER IRDH575 Insulation Monitoring
  • BENDER IRDH265 Insulation Monitoring and Debugging
  • Bender RCMA475LY residual current monitor debugging
  • Beckwith Electric M-3425A Generator Protection Relay Debugging Guide
  • Automated MEX816U Expander Troubleshooting Guide