Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • Emerson 731 Series 48V600A/R48-3000E3 power supply
    ❤ Add to collection
  • Emerson 731 Series 48V600A/R48-3000E3 power supply

    • ¥36487.00
      ¥34646.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:0.000KG
    • Quantity:
    • (Inventory: 50)
Description

The Net Sure731 system can be configured in four main ways:

1. Single AC input, no user AC output circuit breaker;

2. Single AC input, user AC output circuit breaker;

3. Dual AC input, manual switching;

4. Dual AC input, automatic switching (maximum configuration); In addition, in general, in the DC distribution unit of the power system, the load branch and the battery protection branch are connected by short-circuit bars, and the system does not have the load power-off function. If the system needs to provide the load power-off function, you need to select a load power-off unit instead of a short-circuit bar. The internal structure of the power system is based on the strongest configuration, and other configurations only remove certain components. In maximum configuration.

Net Sure731 48V600A intelligent high frequency switching power supply system is suitable for base stations, small and medium capacity exchanges, satellite communications, data communications and other power grid fluctuation range is very wide occasions. Net Sure731 48V600A Intelligent High Frequency Switching Power system is easy to operate, install and maintain. The AC input and output cables and DC input and output cables can enter and exit freely from the top or bottom of the cabinet.


Its main features are:

 rectifier module using active power factor compensation technology, power factor value of 0.99.

 The AC input voltage has a wide normal operating range. For the system without automatic switching, the AC input voltage can be 85~290V. For the system with automatic switching, the voltage range can be 125~285V.

 Rectifier module Ultra-low radiation. With advanced electromagnetic compatibility design, the rectifier module can meet the requirements of CE, NEBS, YD/T983 and other domestic and foreign standards. The conduction and radiation of the rectifier module can meet the requirements of Class B.  Rectifier module safety design in line with UL, CE, NEBS standards.

 The module has high power density.

 The rectifier module uses the non-damaging hot swap technology. The replacement time is less than 1 minute.

 The rectifier module has output overvoltage hardware protection and output overvoltage software protection. There are two options for software overvoltage protection: primary overvoltage locking mode and secondary overvoltage locking mode.

 Perfect battery management. It has the function of battery low voltage protection and load power-off (optional), which can realize temperature compensation, automatic voltage regulation, stepless current limiting, battery capacity calculation, online battery test and other functions.

 Up to 200 historical alarm records can be recorded. Up to 10 groups of battery test data can be recorded.

 Network design, provides RS232, Modem, dry contact and other communication interfaces, flexible networking, can realize remote monitoring, unattended.

 Perfect lightning protection design for AC and DC side.  Complete fault protection and fault alarm

 The power system cabinet can be installed against a wall and operated and maintained on the front of the cabinet.

 is equipped with an optional cabinet cover and air filter.

The working principle of the system is that the mains enters the rectifier module through the AC distribution branch, and the -48V DC rectified by each rectifier module enters the DC distribution through the tandem connection, and is provided to the communication equipment in multiple channels. Under normal circumstances, the system runs in parallel floating charging state, that is, the rectifier module, load, and battery work in parallel. The rectifier module not only supplies power to the communication equipment, but also provides floating charging flow for the battery. When the mains power is off, the rectifier module stops working, and the battery supplies power to the communication device to maintain the normal operation of the communication device. After the mains is restored, the rectifier module supplies power to the communication device and charges the battery to replenish the consumed power. The monitoring module uses centralized monitoring to manage AC power distribution and DC power distribution, and receives the operating information of the rectifier module through CAN communication and controls it accordingly. The monitoring module can also be connected to the local computer through RS232, and can be connected to the monitoring center through the Modem or other transmission resources (such as the official channel, etc.) to realize the centralized monitoring network of the power system.

The main function of the system

Net Sure731 48V600A Intelligent High frequency Switching Power Supply system has the following main functions:

 Excellent lightning protection design

 AC input overvoltage protection

 Load power-off and Battery Low Voltage protection (LLVD+BLVD)

 Fault alarm and protection

 Provides multi-channel and multi-specification DC output

 monitoring and four remote function

Ac input overvoltage protection

The Net Sure731 48V600A system has complete input overvoltage protection. For systems without automatic switching, the overvoltage protection is referred to the Overvoltage protection of the rectifier module in Chapter 2. For the automatic switching system with AC contactor, when the AC voltage reaches a certain set overvoltage point, the AC contactor will be automatically disconnected and the AC will be automatically cut off to protect the rectifier module and subsequent user AC equipment. When the AC input voltage returns to normal, the AC contactor can automatically close, and the rectifier module and other user AC equipment can automatically return to normal work.


Load power-off and battery low voltage protection

When the AC power is off and the rectifier module has no DC output, the battery starts to discharge. Set when voltage drops to undervoltage

When the fixed point is 45.0V (adjustable), the system will issue sound and light alarm. When the battery voltage continues to drop below the load

When the electric operating point is 44.0V (adjustable), the load power off contactor is disconnected and connected to the load power off branch

General communication loads (such as local switches) will be cut off from the power supply, and critical loads (such as transmission devices)

Standby) power supply can thus be extended. As the battery discharge process continues, if the battery discharge to termination

Voltage battery protection action point 43.2V (adjustable), the battery protection contactor will be disconnected, the battery discharge process will be terminated, and the power supply of all communication loads will be suspended, so as to avoid battery damage due to overdischarge. When an AC call comes in and the rectifier module outputs a normal DC voltage, the load is powered off and the battery contactor automatically closes, and the system returns to normal operation.

Functions such as load power-off and battery low voltage protection can be manually controlled.

Fault alarm and protection

Net Sure731 48V600A power supply system with complete fault warning and protection. The monitoring module can collect system data in real time, and detect the status of load output fuse, battery fuse, and II/C level surge protection device. You can flexibly set alarm levels for system faults, such as AC input overvoltage or undervoltage, DC output overvoltage or undervoltage, and module faults. You can also flexibly configure alarm types indicated by alarm dry nodes.


Choose Xiamen control Smith after sale worry

Excellent product quality

Only cooperate with manufacturers of first-line brands in the industry

Imports/Products

Good pre-sale service

Communicated with customers repeatedly about product model, quality, price and delivery date

Work with the customer to determine the best solution

Address user concerns in advance

Business execution in place

Ordered products delivered on time

Make perfect delivery plan to ensure the time limit

Assist users to handle the acceptance procedures

Perfect after-sales service

During the warranty period, problems will only be replaced and not repaired

Never put a problem on the back of your head

Service hotline 7x24 hours service


Solemn promise

1. All the items sold by the company, module card parts, etc., the quality problems arising from normal use during the warranty period are replaced free of charge, and there is no evasion.

2. For materials and equipment that have not been discontinued beyond the warranty period, only the cost of relevant parts will be charged for quality problems.

3. Provide replacement models and equipment replacement process services for discontinued materials and equipment.

4. Customers have purchased materials and equipment, lifetime free upgrade system software, related technical information provided free of charge.

5. Visit the use of materials purchased by customers from time to time, and solve any problems in time.

6. The company hotline provides 24-hour service, and the questions raised by customers are answered within 1 hour.

7. Not done, the company spirit of "thoughtful service, responsible to the end" attitude, from the customer's point of view to solve the problem, with serious and rigorous enterprise style, dedicated to each customer service.



  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications
  • Bonfiglioli 300 series reducer installation, maintenance, and troubleshooting guide
  • Selection and integration guide for Bonfiglioli R3 series planetary gearboxes in primary crushing equipment
  • Bonfiglioli C-series ATEX gearbox selection and explosion-proof application guide
  • Bonfiglioli Vectron EM-ENC-05 Full Function Expansion Module Integration Guide
  • Bonfiglioli Vectron EM-ENC-04 Multi functional Expansion Module Complete Configuration Guide
  • Bonfiglioli Vectron EM-ENC-03 Second Encoder Interface and System Bus Expansion Guide
  • Bonfiglioli Vectron EM-ENC-02 Expansion Module Integration and Encoder Interface Guide
  • Bonfiglioli Vectron CM-CAN CANopen Communication Configuration and DS402 Control Guide
  • Bonfiglioli Vectron EM-SYS System Bus Networking and Virtual Link Configuration Guide
  • Bonfiglioli Vectron CM-PDP Profibus DP Configuration and Debugging Guide
  • Bonfiglioli Vectron CM-232/485 Modbus Communication Configuration Guide
  • Bonfiglioli BMS series servo reduction motor selection and integration guide
  • Bonfiglioli ACTION 210/410 Inverter Debugging and Fault Diagnosis Complete Guide
  • Honeywell Enhanced Micro TDC 3000X System Redundancy Architecture and Maintenance Guide
  • Selection and Configuration of Bonfiglioli Active Series Inverter
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli HDP/HDO Series Heavy duty Gearboxes
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli 300/300M Series Gearboxes
  • Bonfiglioli 300M planetary gearbox selection and thermal verification guide
  • Bonfiglioli 3/H series heavy-duty gearbox selection and verification guide
  • Bonfiglioli KRG/KCG/KSD Hydraulic Coupling Selection and Integration Guide