Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • ABB Electrical 1SFA891003R2209 Soft Starter
    ❤ Add to collection
  • ABB Electrical 1SFA891003R2209 Soft Starter

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    Electrical 1SFA891003R2209 Soft Starter
    • ¥981.00
      ¥8320.00
      ¥981.00
      ¥981.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:4.480KG
    • Quantity:
    • (Inventory: 2)
Description
Electrical 1SFA891003R2209 Soft Starter

ABB Electrical 1SFA891003R2209 Soft Starter

Basic Parameters

Rated voltage: Usually applicable to a variety of standard industrial voltage, such as 208V AC - 690V AC and other common voltage levels, the specific rated voltage should be determined according to the actual use of scenarios and motor requirements.

Rated current: The rated current is the maximum current that the soft starter can normally control the motor starting and running, the rated current and other detailed parameters of the model should be referred to the product manual to determine the specific rated current according to different application scenarios and motor power to match the corresponding rated current.

Rated power: the rated power is related to the rated voltage and rated current, different voltage levels correspond to different rated power, for example, in 400V AC, may correspond to the rated power of several tens of kilowatts, etc., the specific value of the product technical data shall prevail.

Functional features

Soft start and soft stop function: By controlling the conduction angle of the thyristor, the input voltage of the motor starts from zero and rises gradually according to the preset function relationship until it reaches the rated voltage, so as to realise the smooth starting of the motor, avoiding the large current impact and mechanical vibration caused by the direct starting. When stopping, the motor voltage can also be gradually reduced to zero to achieve soft stop, reducing the impact on equipment and power grid.

A variety of protection functions:

Overload protection: real-time monitoring of the motor current, when the current exceeds the set value of overload current, the soft starter will automatically cut off the power supply of the motor and send an alarm signal to protect the motor from overload damage.

Phase loss protection: During operation, the three-phase line current is continuously detected, and the power supply will be cut off immediately in case of phase loss, preventing the motor from being burnt due to phase loss.

Overheating protection: the internal thermal relay will monitor the temperature of the thyristor radiator, and when the temperature exceeds the permissible value, it will automatically shut down the thyristor, stop the motor operation, and send out an alarm signal to ensure the safety and reliability of the equipment.

Control and adjustment function: Users can set the starting parameters, such as starting voltage, acceleration time, current limiting multiplier, etc., through the operation panel or communication interface according to the load characteristics of the motor and the actual demand, in order to achieve the best starting effect. At the same time, some models also have torque control function, which can accurately control the output torque of the motor to meet the requirements of different loads.

Communication function: Generally equipped with communication interface, such as Modbus, Profibus and other common communication protocols, it can realise the communication connection with the upper computer control system or other intelligent devices, which is convenient for remote monitoring, parameter setting and centralised management, and improves the degree of automation and the level of intelligence of the system.

Energy-saving function: When the motor is running at light load, the soft starter can automatically reduce the input voltage of the motor, reduce the energy consumption of the motor, realise a certain degree of energy saving effect, and reduce the operating cost.

Application Fields

Industrial field: widely used in various industrial motor starting control, such as pumps, fans, compressors, conveyor belts and other equipment. For example, in the starting of centrifugal pumps in the chemical and pharmaceutical industries, the soft starter can avoid the water hammer effect during starting and protect the pipeline system; in the starting of conveyor belt drive motors in cement factories, the soft starter can achieve a smooth start, reduce the tension impact of the belt, and prolong the service life of the equipment.

Commercial building field: It is also used in the air-conditioning system, lift system and other equipment in commercial buildings. For example, in the central air-conditioning system of large shopping malls, controlling the start-up of air-conditioning compressors through soft starters can reduce the start-up current, reduce the interference to the power grid, and at the same time, improve the operational stability and reliability of the air-conditioning system; in the lift system, it can ensure that the lift motor starts and stops smoothly, and improve the comfort of passengers.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Huichuan AM600 Motion Controller Malfunction and Replacement Guide
  • Allen Bradley Ultra3000 Servo Motor Replacement Guide
  • NEC NL8060BC26-17 LCD Module Maintenance and Replacement
  • ABB Pluto Safety PLC Maintenance and Troubleshooting
  • OMRON NE1A Safety Controller Troubleshooting and Replacement
  • Allen Bradley 2711P series PanelView Plus human-machine interface terminal
  • NI cFP-22xx on-site integration and troubleshooting
  • KEYENCE XG-8000 Line Scan Visual Debugging Guide
  • OMRON G9SX Security Unit Configuration and Troubleshooting
  • OMRON CPM1A Maintenance and Troubleshooting
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide