ABB RET670 1MRK002816-AB Transmission transformer
ABB RET670 1MRK002816-AB Transmission transformer
DESCRIPTION
RET670 IEDs provide customized or pre-configured protection solutions for any type of transformer and shunt reactor application. The customized RET670 gives you the freedom to select functionality entirely according to your needs. The pre-configured RET670 variants simplify handling since the basic functionality is included and pre-configured. If needed, you can add optional functions to increase the functionality of the pre-configured RET670 IEDs to meet the specific requirements of your transformer or shunt reactor.
Product Overview
The RET670 1MRK002816-AB relay integrates a wide range of protection functions and is characterised by high-precision measurement, fast response and flexible configuration. It is designed for power system protection and control, which can ensure the stable operation of power system.
Main Functions
Multiple protection functions:
Provide multiple protection functions such as over-current protection, under-voltage protection, over-voltage protection, ground fault protection and so on.
Differential protection function: with 2nd harmonic and waveform block suppression function, as well as 5th harmonic suppression function, it can avoid CT saturation and transformer inrush current tripping.
High impedance differential protection function: it can be used for winding protection, autotransformer differential protection, shunt reactor protection and so on.
High precision measurement:
Adopting advanced digital signal processing technology, it is capable of high-precision measurement of current, voltage and other electrical parameters.
Real-time monitoring and analysis of changes in electrical parameters, accurately determine the operating status of electrical equipment and motors.
Fast Response:
With fast response speed, it can quickly cut off the faulty circuit when the fault occurs, preventing the fault from expanding and equipment damage.
Flexible configuration:
Supporting flexible configuration and programming, users can customise personalised protection solutions according to actual needs and characteristics of the power system.
Remote monitoring and control:
Supports remote monitoring and control functions, allowing operators to remotely monitor the status of the power system and carry out necessary operations.
Application Areas
RET670 1MRK002816-AB relay is mainly used in the protection of power equipment, such as transformers, cables, generators and so on. It is widely used in power systems, power plants, substations, industrial enterprises and buildings to ensure the stable operation of power systems.
Technical features
High integration: integrates a variety of protection functions and measurement functions in one, reducing the number and complexity of devices.
Low power consumption: adopts low-power processor and circuit design, reducing the energy consumption of the device.
Easy maintenance: supports remote monitoring and control function, which is convenient for users to maintain and manage the equipment.
Product Advantages
High reliability: Manufactured with advanced technology and high-quality materials to ensure the reliability and durability of the product.
Comprehensive functions: integrates a variety of protection functions and measurement functions to meet the multiple needs of the power system.
Easy to operate: Provides friendly user interface and explicit message alarms, which is convenient for users to carry out debugging and operation.
Installation and Maintenance
Environmental Conditions:
Ensure that the module is installed within the recommended temperature and humidity ranges and avoid direct exposure to water, oil, dust or electromagnetic interference.
Power Requirements:
Use a stable power supply to avoid damage to the module from voltage fluctuations.
Signal Cable Connection:
Connect the signal lines correctly to ensure the accuracy and stability of signal transmission.
Software Configuration:
Correctly configure the software parameters of the module according to the system requirements to ensure compatibility with other parts of the control system.
Maintenance and Inspection:
Perform regular maintenance and inspection of the module, including cleaning and checking the contact status of the connectors.
Precautions
Operator Training:
Operators should receive proper operation and maintenance training to avoid malfunctions or safety accidents caused by incorrect operation.
Technical Documentation and Safety Guidelines:
The technical documentation and safety guidelines provided by the manufacturer should be read and understood in detail before installation and use.
Compliance with safety procedures:
Observe all relevant safety procedures to ensure personal safety, especially when handling high-pressure or high-speed rotating equipment.
email:1583694102@qq.com