Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • ABB AI04 Input/Output System
    ❤ Add to collection
  • ABB AI04 Input/Output System

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    The AI04 input/output system is positioned with "precise signal interaction+flexible system adaptation" as its core, and achieves centralized processing of different types of on-site signals through modular design. Its functions cover three dimensions: signal acquisition, control output, and system collaboration, ensuring the effective execution of upper level control instructions and real-time feedback of on-site operation data.

    • ¥22463.00
      ¥24737.00
      ¥22463.00
      ¥22463.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:1.150KG
    • Quantity:
    • (Inventory: 99999)
Description

The AI04 input/output system is positioned with "precise signal interaction+flexible system adaptation" as its core, and achieves centralized processing of different types of on-site signals through modular design. Its functions cover three dimensions: signal acquisition, control output, and system collaboration, ensuring the effective execution of upper level control instructions and real-time feedback of on-site operation data.


ABB AI04 Input/Output System

Core functional positioning

The AI04 input/output system is positioned with "precise signal interaction+flexible system adaptation" as its core, and achieves centralized processing of different types of on-site signals through modular design. Its functions cover three dimensions: signal acquisition, control output, and system collaboration, ensuring the effective execution of upper level control instructions and real-time feedback of on-site operation data.

1. Multi dimensional signal acquisition and processing

The AI04 system has strong signal compatibility capabilities and can provide dedicated acquisition channels for common signal types in industrial sites, including analog inputs (such as 4-20mA current signals, 0-10V voltage signals, thermal resistance Pt100, thermocouple K-type, etc.) and digital inputs (such as dry contact and wet contact signals). The system is equipped with a high-precision signal conditioning module, which effectively improves the accuracy of signal acquisition through filtering, amplification, cold end compensation and other technical means. At the same time, it adopts a photoelectric isolation design to electrically isolate the input signal from the system core circuit, with an isolation voltage of up to 2500Vrms, which can effectively suppress electromagnetic interference (EMI) and ground loop interference in industrial sites, ensuring the stability of collected data.

2. Reliable control signal output

In terms of control output, the AI04 system supports analog output (4-20mA/0-10V) and digital output (relay output/transistor output), which can directly drive on-site actuators such as regulating valves, solenoid valves, contactors, etc. The analog output accuracy can reach ± 0.1% FS, enabling precise adjustment of the actuator; Digital output has high switching frequency and load capacity, relay output type can drive high-power loads, and transistor output type is suitable for high-frequency switching scenarios. The system also has an output signal diagnostic function. When there is an open circuit, short circuit or other fault in the output circuit, it can be promptly fed back to the upper system for easy troubleshooting.

3. Efficient system collaboration and expansion

The AI04 system adopts standardized communication interfaces and modular architecture, which can seamlessly integrate with mainstream ABB control systems (such as AC 800M DCS, AC 500 PLC, etc.), while supporting general industrial communication protocols such as PROFINET, EtherNet/IP, MODBUS, etc., to achieve efficient data exchange with upper level systems and other intelligent devices. The system supports cascading expansion of multiple modules, achieving collaborative work between modules through backplane bus or Ethernet. Users can flexibly configure the number of input and output channels according to on-site needs, minimizing system redundancy and improving resource utilization.


Key technical parameters

Technical parameters are the core manifestation of the performance of AI04 input-output system, directly determining its adaptability and operational performance in industrial sites. The following are the main technical parameter descriptions:

1. Power parameters

-Input voltage: DC 24V (wide range adaptation DC 19.2V-30V), meeting the standard power supply requirements in the industrial control field;

-Power protection: equipped with overvoltage, overcurrent, and reverse connection protection functions to prevent system damage caused by abnormal power supply;

-Power consumption: The typical power consumption of a single module is ≤ 3W, and the total power consumption can be controlled when multiple modules are cascaded, reducing system energy consumption.

2. Input parameters

-Analog input: Supports 4/8 channel configuration, with a sampling rate of up to 100Hz/channel. Different signal types can be flexibly configured, such as 4-20mA input impedance ≤ 250 Ω, Pt100 input accuracy ± 0.1 ℃ (-200 ℃~600 ℃);

-Digital input: Supports 8/16 channel configuration, input voltage DC 24V (allowable fluctuation range DC 15V-30V), response time ≤ 1ms, supports dry/wet contact signal access;

-Isolation performance: Optoelectronic isolation is used between input channels and between channels and power supply, with an isolation voltage of ≥ 2500Vrms and surge resistance in accordance with IEC 61000-4-5 standard.

3. Output parameters

-Analog output: Supports 4/8 channel configuration, output range 4-20mA (load capacity 0-500 Ω) or 0-10V (load capacity ≥ 1k Ω), output accuracy ± 0.1% FS, temperature drift ≤ 50ppm/℃;

-Digital output: Relay output supports 8 channels, with contact capacity of AC 250V/5A or DC 30V/5A; Transistor output supports 16 channels, output current ≤ 0.5A/channel, response time ≤ 0.1ms;

-Output protection: The relay output has contact wear detection function, and the transistor output has overcurrent protection function.

4. Environmental and communication parameters

-Environmental adaptability: working temperature -25 ℃~70 ℃, relative humidity 5%~95% (no condensation), protection level IP20 (module body), suitable for harsh on-site environments such as high temperature and humidity;

-Communication interface: standard RJ45 Ethernet interface, supporting 10/100Mbps adaptive, some models support PROFINET RT/IRT communication, meeting real-time control requirements;

-Diagnostic function: Supports channel level fault diagnosis, including signal over range, disconnection, short circuit, etc. Diagnostic information can be uploaded to the upper system through the communication bus.


Applicable scenarios and typical applications

The AI04 input-output system, with its precise signal processing capabilities, reliable operational performance, and flexible scalability, has been deeply applied in multiple industrial fields. Typical scenarios are as follows:

1. Process industry (chemical, petrochemical)

In the chemical production process, the AI04 system is used to collect key parameters such as temperature, pressure, liquid level, and flow rate of the reaction kettle, and output control signals to adjust the feed valve, stirring motor, and other actuators. Its high-precision analog acquisition capability can monitor process parameter changes in real-time during the reaction process. The anti-interference design ensures stable operation in flammable, explosive, and strong electromagnetic interference environments, providing reliable data support for closed-loop control of the production process and ensuring production safety and product quality.

2. Energy industry (electricity, new energy)

In the boiler control system of thermal power plants, the AI04 system is responsible for collecting parameters such as boiler feedwater flow rate, steam pressure, furnace temperature, and controlling equipment such as feedwater regulating valves and induced draft fan baffles; In a photovoltaic power station, the system can collect the output current, voltage, and ambient temperature signals of photovoltaic modules, and control the start and stop of the inverter through digital output. Its wide temperature range and high reliability can adapt to high temperatures, high dust, and harsh outdoor environments in power plants, ensuring stable monitoring of the energy production process.

3. Discrete manufacturing industry (automotive, mechanical processing)

In the automotive welding production line, the AI04 system collects the in place signal and fixture clamping signal of the welding robot through digital input, and adjusts the welding current and voltage through analog output; In mechanical machining machines, the system can collect parameters such as spindle speed and tool temperature, and control the opening and closing of the coolant valve. Its fast digital response capability and flexible module configuration can adapt to the diverse control needs of the production line, improving the level of production automation and efficiency.

4. Municipal engineering (water treatment, heating)

In the sewage treatment plant, the AI04 system collects parameters such as sewage pH value, dissolved oxygen content, sludge concentration, etc., and controls the operation of equipment such as aeration fans and dosing pumps; In urban heating systems, the system can collect temperature and pressure signals from heating pipelines and adjust the water supply valves of heat exchange stations. Its stable signal processing capability ensures the automated operation of municipal facilities, reduces manual operation and maintenance costs, and enhances the reliability of public services.


Key points for installation and maintenance

Scientific installation and standardized maintenance are key to ensuring the long-term stable operation of the AI04 input/output system. The core points are as follows:

1. Installation specifications

-Installation location: The module should be installed in a well ventilated area away from high temperatures (such as boilers and heaters), high humidity, and strong electromagnetic interference sources (such as frequency converters and high-voltage cables). The module should be installed vertically on a standard DIN rail to avoid direct sunlight and rainwater immersion;

-Wiring requirements: Analog signals and digital signals should be wired separately to avoid signal crosstalk caused by parallel laying; Shielded cables should be used for power and signal lines, with the shielding layer grounded at one end; When wiring, it is necessary to strictly follow the module terminal definition to ensure that the wiring is firm and avoid false connections that may cause signal abnormalities;

-Module expansion: When multiple modules are cascaded, they need to be connected through dedicated backplane buses or communication cables to ensure smooth communication between modules, while reserving sufficient heat dissipation gaps (recommended ≥ 10mm) to prevent module overheating.

2. Maintenance points

-Daily inspection: Regularly check the status of module indicator lights (power light, communication light, fault light) to confirm that there are no abnormal alarms; Check whether the wiring terminals are loose or oxidized, tighten the loose terminals in a timely manner, and clean the oxidized terminals with fine sandpaper;

-Cleaning and maintenance: Use a dry brush or compressed air to remove dust from the surface of the module and the heat dissipation holes every quarter to avoid dust accumulation and affect heat dissipation; Do not use damp cloths or corrosive cleaning agents to wipe the module to prevent short circuits or component damage;

-Fault handling: When a system malfunction occurs, the fault channel and cause can be viewed through the diagnostic interface of the upper level control system. If it is a signal fault, it is necessary to check the on-site sensors/actuators and wiring; If it is a communication failure, it is necessary to check the communication cable, protocol configuration, and network connection; If it is a module failure, the backup module should be replaced in a timely manner to ensure continuous production;

-Firmware update: According to the official firmware upgrade package released by ABB, regularly update the module firmware to improve system performance and compatibility; Before upgrading, it is necessary to backup the system configuration to ensure stable power supply during the upgrade process and avoid module damage caused by upgrade interruptions.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • TOSHIBA VF-S15 frequency converter
  • TOSHIBA Color TV User Manual
  • TOSHIBA 2505AC, 3005AC, 3505AC series multifunctional laminating machines
  • TOSHIBA External and Internal Hard Drives
  • TOSHIBA 1600XPi Series UPS Installation and Operation
  • TOSHIBA TOSBERT S11 series frequency converter
  • Toshiba TOSBERT S7 series frequency converter
  • Toshiba Motors Low & Medium Voltage Product Offering
  • TOSHIBA VF-AS3 inverter RS485 communication function
  • TOSHIBA TOSBERT VF-A3 frequency converter
  • TOSHIBA V200 series programmable logic controller
  • TOSHIBA TOSBERT VF-S15 series frequency converter
  • TRICON ®/ Installation and maintenance of E/E2/E3 transmitters
  • TRLC0NEX Tricon fault-tolerant controller
  • WAGO 221 series LEVER-NUTS ® Compact splicing connector
  • WAGO-I/O-SYSTEM 750 Programmable Fieldbus Controller ETHERNET 
  • WAGO Rail-Mount Terminal Blocks with Screw and Stud Connection
  • WAGO series molded case circuit breaker (MCCB)
  • WAGO Rail-Mount Terminal Blocks
  • WAGO I/O System 750/753 Series Distributed Automation System
  • HIMA X-CPU 01 processor module
  • Westinghouse iGen5000 Digital Inverter Generator
  • Westinghouse WGen7500DF Dual Fuel Portable Generator
  • Westinghouse WPX2700H/WPX3100H High Pressure Cleaning Machine
  • Westinghouse WH7500V portable generator
  • Westinghouse WGen9500c portable generator
  • Westinghouse DS/DSL series low-voltage power circuit breakers
  • Westinghouse ePX3500 Electric High Voltage Cleaning Machine
  • Westinghouse ST Switch Intelligent Automatic Portable Transfer Switch
  • Westinghouse 2400i digital inverter generator
  • Westinghouse iGen series digital inverter generator
  • HIMA CPU 01 Controller Module
  • Westinghouse WPX3000e/WPX3400e electric high-pressure cleaning machine
  • Westinghouse WGen2000, WGen3600, and WGen3600V portable generators
  • Westinghouse WGen5500 Generator
  • Westinghouse WGen20000 Generator
  • Westinghouse WPro8500 and WPro12000 portable generators
  • Westinghouse iGen4500DFc Dual Fuel Digital Variable Frequency Generator
  • Watlow Series L Temperature Limiting Controller
  • Watlow Series F4P Temperature/Process Controller
  • Watlow EZ-ZONE ® RME (Expansion) Module
  • Watlow EZ-ZONE ® RMA (Access) module
  • Watlow PM PLUS ™ 6 Series PID Integrated Controller
  • Watlow Immersion Heater
  • Watlow F4T Controller Installation and Failure
  • Watlow DIN-A-MITE ® Style C Solid State Power Controller
  • Watlow plug-in heater
  • Watlow Series 942 Controller
  • Watlow Series 988 Controller
  • Watlow Series 146 Temperature Regulator
  • Watlow PM LEGACY ™ Limit controller
  • How to install Johnson AE55/NIE55?
  • Watlow Series 96 Temperature Controller
  • Watlow PM PLUS ™ PID/Integrated Limit Controller
  • Watlow Ceramic Fiber Heater
  • Watlow Power Series microprocessor based SCR power controller
  • Watlow thermocouple products
  • Watlow Series 965 Controller
  • Watlow PM3 LEGACY ™ PID controller
  • Watlow Series 93 Controller
  • Watlow EZ-ZONE ® PM PID controller
  • Watlow CLS200 series controller
  • YAMAHA RCX40 4-axis robot controller
  • YASKAWA Z1000 series HVAC dedicated frequency converter
  • YASKAWA HV600&Z1000U series HVAC dedicated frequency converter
  • YASKAWA Power Regenerative Unit R1000 Series
  • YASKAWA AC Drive P1000 Industrial Fan and Pump Special Frequency Converter
  • YASKAWA FP605 series industrial fan pump dedicated driver
  • YASKAWA GA500 series AC micro driver
  • YASKAWA AC Drive G7 Series (Model CIMR-G7U)
  • YASKAWA U1000 series 24V power supply options (PS-U10L/PS-U10H)
  • YASKAWA GA800 industrial AC frequency converter Key issues
  • How to select YASKAWA GA800 industrial AC frequency converter?
  • YASKAWA AC Drive V1000 Compact Vector Control Drive
  • YASKAWA Control Pack CP-317M System Controller
  • YASKAWA VARISPEED-626M/656MR5 series vector control frequency converter
  • YASKAWA AC Servo Drive HR Series (CACR-HR) Multi functional/Positioning Control
  • YASKAWA MP2000 series machine controller communication module
  • Yokogawa AQ1100 series OLTS multi field tester
  • YOKOGAWA AQ7280 Optical Time Domain Reflectometer
  • YOKOGAWA AQ2200 Series Multi Application Testing System
  • YOKOGAWA AQ6150B/AQ6151B Optical Wavelength Meter
  • YOKOGAWA AQ6360 Optical Spectrum Analyzer
  • Yokogawa AQ6375E Spectral Analyzer Remote Control
  • Yokogawa DL350 Scope Order Communication Interface
  • Yokogawa 701944/701945 100:1 High Voltage Probe
  • Yokogawa CA700 pressure calibrator
  • Yokogawa DLM5000HD series high-definition oscilloscope
  • Yokogawa AQ1210 Series OTDR Multi Field Tester
  • Yokogawa AQ1000 OTDR Optical Time Domain Reflectometer
  • YOKOGAWA WT1801R series precision power analyzer communication interface
  • YOKOGAWA DLM3034HD/DLM3054HD High Definition Oscilloscope
  • YOKOGAWA AQ23011A/AQ23012A Modular Framework Equipment
  • YOKOGAWA DLM3054HD Mixed Signal Oscilloscope
  • YOKOGAWA CW500 Power Quality Analyzer
  • How to troubleshoot the YOKOGAWA CA500/CA550 multifunctional process calibrator?
  • How to maintain YOKOGAWA AQ7420 High Resolution Reflectometer?
  • YOKOGAWA FG410/FG420 arbitrary waveform editor
  • How to check the packaging and accessories of Yokogawa Model 701905 conversion cable?
  • YOKOGAWA MY600 Digital Insulation Resistance Tester
  • YOKOGAWA AQ7290 Series Optical Time Domain Reflectometer OTDR
  • How to ensure the safety and maintenance of YOKOGAWA LS3300 AC power calibrator?
  • Yokogawa AQ6377E Optical Spectrum Analyzer Remote Control
  • Yokogawa AQ6361 Optical Spectrum Analyzer
  • Yokogawa IS8000 Integrated Software ECU Monitoring and Synchronization Function
  • Yokogawa ROTAMASS TI Coriolis Mass Flow Meter
  • Yokogawa ROTOMETER RAMC Metal Variable Area Flow Meter
  • Yokogawa SL1000 high-speed data acquisition unit input module
  • How to install and wire the Yokogawa FLXA402T turbidity and chlorine liquid analyzer?
  • Yokogawa WTB10-DO Series Dissolved Oxygen Measurement System Terminal Box
  • Yokogawa Model 702928 PBD0200 Differential Probe
  • YOKOGAWA ADMAG TI Series AXW Electromagnetic Flow Meter (25-450mm) Installation and Operation
  • How to troubleshoot YOKOGAWA ADMAG TI series AXW electromagnetic flowmeter (25-1800mm)?
  • How to install YOKOGAWA DO30G dissolved oxygen sensor?
  • YOKOGAWA SC4AJ Conductivity Sensor Manual
  • YOKOGAWA SC210G Conductivity Detector
  • How to install and wire Yokogawa PH4/OR4 series pH and ORP sensor (IM12B10B00-01EN)?
  • How to troubleshoot Yokogawa OR8EFG KCl filled ORP sensor (IM12C07J01-01E)?
  • YOKOGAWA FU24 pH/ORP Composite Sensor with Pressure Compensation (IM 12B06J03-03EN-P)
  • Yokogawa SC200 Intelligent Two Wire Conductivity Transmitter System (IM12D08B01-01E)
  • YOKOGAWA CENTUM VP Integrated Production Control System (TI33J01A10-01EN)
  • ABB AO2000-LS25 Laser Analysts User Manual
  • YOKOGAWA FA-M3 positioning module (with analog voltage output)
  • YOKOGAWA FA-M3 Series Basic Modules
  • YOKOGAWA EJA110E Diff erential Pressure Transmitter
  • Zygo 3D Optical Profiler
  • How to unpack and install the Zygo Mark II 4-inch interferometer system?
  • Zygo NewView 9000 3D Optical Profilometer Technology Advantages