  • FOXBORO FCP270 Field Control Processor Petroleum control system
    ❤ Add to collection
  • FOXBORO FCP270 Field Control Processor Petroleum control system

    FOXBORO FCP270 Field Control Processor Petroleum control system

    • ¥36500.00
      ¥36255.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:5.300KG
    • Quantity:
    • (Inventory: 33)
Description

FOXBORO FCP270 Field Control Processor Petroleum control system


FOXBORO FCP270 Field Control Processor Petroleum control system

OVERVIEW

The Field Control Processor 270 (FCP270) is a distributed, optionally fault-tolerant, field-mounted controller module. The FCP270 performs regulatory, logic, timing, and sequential control together with connected Fieldbus Modules. It also performs data acquisition and alarm detection and notification. The FCP270 connects to the Foxboro Evo control network via standard fiber optic 100 Mbps Ethernet.The fault-tolerant version of the FCP270 consists of two processor modules.

FEATURES

 Performs regulatory, logic, timing, and sequential control together with connected Fieldbus Modules (FBMs) 

 Performs data acquisition and alarm detection and notification 

 Supports up to 32 200 Series FBMs - referring to both Compact or standard types 

 Supports up to 128 200 Series FBMs (Compact or standard) with a Fieldbus Expansion Module 100 (FEM100) 

 Supports up to 64 of the 100 Series FBMs

 No Fieldbus Communication Module is required 

 Connects to the Foxboro Evo control network via standard fiber optic 100 Mbps Ethernet 

 Uses a rugged, die cast aluminum housing for mounting in a non-vented field enclosure 

 Can operate in Class G3 harsh environments 

 Is CE certified for field mounting in enclosures 

 Supports both the 2 Mbps or 268 Kbps HDLC fieldbuses simultaneously with the FBI200 allowing connections to both 200 Series and 100 Series FBMs (affects the total number of each type of FBM supported)

 Supports the extension of the 268 Kbps HDLC fieldbus with the FBI100 to the 100 Series FBMs 

 Offers unique, patented, fault-tolerant operation using two control modules to greatly improve reliability relative to other process controllers 

 Uses versatile control algorithms and a wide variety of FBMs to provide control capabilities for a broad range of process applications 

 Supports time synchronization using optional external time from GPS satellites 

 Offers on-line image update of a fault-tolerant FCP270 without shutting down the process 

 Uses soft letterbugs configurable via the I/A Series® system Letterbug Configurator running on a Pocket PC 

 Supports self-hosting mode with I/A Series software v8.4-v8.8 or Foxboro Evo™ Control Core Services v9.0 or later

REMOTE MOUNTING

The FCP270 flattens and simplifies the Foxboro Evo Process Automation System architecture, which only requires field enclosures plus workstations and Ethernet switches. For more information on The Foxboro Evo control network architecture, refer to PSS 21H-7C2 B3.

The field-mounted FCP270 is an integral part of the highly-distributed control network where controllers are closely aligned to specific process units mounted in close proximity to their I/O and the actual equipment being controlled. Coordination between process units takes place via a fiber optic 100 Mbps Ethernet network.

The FCP270 is packaged in a rugged, die cast aluminum housing that does not require venting due to its efficient design. The FCP270 is CE certified, and it can be mounted without expensive special cabinets to prevent electronic emissions. The FCP270 can be mounted in Class G3 harsh environments.

ENHANCED RELIABILITY (FAULT-TOLERANCE)

The unique and patented fault-tolerant operation of the FCP270 greatly improves reliability relative to other process controllers. The fault-tolerant version of the FCP270 consists of two modules operating in parallel, with two Ethernet connections to The Foxboro Evo control network. The two FCP270 modules, married as a fault-tolerant pair, provide continuous operation of the controller in the event of virtually any hardware failure occurring within one module of the pair.

Both modules receive and process information simultaneously, and faults are detected by the modules themselves. One of the significant methods of fault detection is comparison of communication messages at the module external interfaces. Messages only leave the controller when both controllers agree on the message being sent (bit for bit match). Upon detection of a fault, self-diagnostics are run by both modules to determine which module is defective. The non-defective module then assumes control without affecting normal system operations. This fault-tolerant solution has the following major advantages over controllers that are merely redundant:

 No bad messages are sent to the field or to applications using controller data because no message is allowed out of the controller unless both modules match bit for bit on the message being sent. 

 The secondary controller is synchronized with the primary one, which ensures up to the moment data in the event of a primary controller failure. 

 The secondary controller will have latent flaws detected prior to any switchover because it is performing exactly the same operations as the primary controller.

SPLITTER/COMBINER

Fault-tolerant FCP270 modules connect to a pair of fiber optic splitter/combiners (see Figure 1) that connect to Ethernet switches in the Foxboro Evo control network. For each module, the splitter/combiner pair provides separate transmit/receive fiber connections for Ethernet switch 1 and 2. Fiber cables are connected so that the splitter/combiners pass inbound traffic from either switch to both modules, and pass outbound traffic from the primary module to either switch. The splitter/combiner pair mounts in an assembly that fastens to the FCP270 baseplates. The splitter/combiner is a passive device that uses no electrical power.

UPGRADE OPTIONS

Multiple options are available for replacing control processors controlling 100 Series FBMs with the FCP270 in a Foxboro Evo network. Cabling the 100 Series FBMs or Migration products to an FCP270 baseplate consists of extending the remote 268 Kbps fieldbus between enclosures. This is accomplished using termination cable assemblies (TCAs) and Fieldbus Isolators (FBIs) to provide connections between primary and extended fieldbus segments. For direct connections from the FCP270 to the 100 Series FBMs, the maximum fieldbus length is 1 km (3200 ft). An FBI100 can be used to extend the fieldbus to 1.83 km (6000 ft).

APPLICATIONS

• Simulation 

• Instrumentation 

• Industrial control 

• Process control and monitoring 

• Factory automation 

• Intelligent networked PLC controllers 

• Automated test 

• Data acquisition


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications
  • Bonfiglioli 300 series reducer installation, maintenance, and troubleshooting guide
  • Selection and integration guide for Bonfiglioli R3 series planetary gearboxes in primary crushing equipment
  • Bonfiglioli C-series ATEX gearbox selection and explosion-proof application guide
  • Bonfiglioli Vectron EM-ENC-05 Full Function Expansion Module Integration Guide
  • Bonfiglioli Vectron EM-ENC-04 Multi functional Expansion Module Complete Configuration Guide
  • Bonfiglioli Vectron EM-ENC-03 Second Encoder Interface and System Bus Expansion Guide
  • Bonfiglioli Vectron EM-ENC-02 Expansion Module Integration and Encoder Interface Guide
  • Bonfiglioli Vectron CM-CAN CANopen Communication Configuration and DS402 Control Guide
  • Bonfiglioli Vectron EM-SYS System Bus Networking and Virtual Link Configuration Guide
  • Bonfiglioli Vectron CM-PDP Profibus DP Configuration and Debugging Guide
  • Bonfiglioli Vectron CM-232/485 Modbus Communication Configuration Guide
  • Bonfiglioli BMS series servo reduction motor selection and integration guide
  • Bonfiglioli ACTION 210/410 Inverter Debugging and Fault Diagnosis Complete Guide
  • Honeywell Enhanced Micro TDC 3000X System Redundancy Architecture and Maintenance Guide
  • Selection and Configuration of Bonfiglioli Active Series Inverter
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli HDP/HDO Series Heavy duty Gearboxes
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli 300/300M Series Gearboxes
  • Bonfiglioli 300M planetary gearbox selection and thermal verification guide
  • Bonfiglioli 3/H series heavy-duty gearbox selection and verification guide
  • Bonfiglioli KRG/KCG/KSD Hydraulic Coupling Selection and Integration Guide
  • Bonfiglioli BTD/BCR Servo Motor System Integration and Interface Configuration Guide
  • Bonfiglioli BTD/BCR Synchronous Servo Motor Selection and Interface Configuration Guide
  • Bonfiglioli VF-W series ATEX explosion-proof reducer selection guide
  • Bonfiglioli EM-ENC-03 Expansion Module Configuration and System Bus Integration Guide
  • Bonfiglioli EVOX CP Explosion proof Reducer: Quick Guide for Installation and Maintenance
  • Bonfiglioli C/A/F/S Reducer ATEX Installation and Maintenance Practice Guide
  • Bonfiglioli BXN/MXN Motor Installation and Brake Maintenance Complete Guide
  • Bonfiglioli VF-W IE2/IE3 Worm Gear Reducer: Energy Efficiency Selection and Application Practice Guide
  • Bonfiglioli VF-W Explosion proof Worm Gear Reducer: ATEX Selection and Installation Complete Guide
  • Selection and Calculation of Bonfiglioli RAN Right Angle Gearbox