  • Foxboro Standard 200 Series Power Supply - FPS400-24
    ❤ Add to collection
  • Foxboro Standard 200 Series Power Supply - FPS400-24

    Foxboro Standard 200 Series Power Supply - FPS400-24

    • ¥33510.00
      ¥33156.00
      ¥33510.00
      ¥33510.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.200KG
    • Quantity:
    • (Inventory: 35)
Description

Foxboro Standard 200 Series Power Supply - FPS400-24


Foxboro Standard 200 Series Power Supply - FPS400-24

Overview

The Foxboro™ DCS Standard 200 Series power supplies provide 24 V DC to standard 200 Series baseplates. The Model FPS400-24 is a 400 W power supply that is agency certified for use in Division 2 and Zone 2 applications. Two different input voltage power supplies are offered:

• 120/240 V AC or 125 V DC input (P0922YU) 

• 24 V DC input (P0922YC).

These power supplies are the only power supplies that have been tested and qualified by Foxboro DCS for use with 200 Series Fieldbus Modules (FBMs).

For sites where a lower-powered and/or smaller sized solution than the FPS400-24 power supply is desired, the FPS240-24 and FPS120-24 power supplies are available. They are discussed in 200 Series Power Supplies - FPS240-24 and FPS120-24 (PSS 41H-2FPS).

Features

• Wide range of AC and DC input voltages 

• High efficiency 

• Power factor correction 

• Dual stage current limiting 

• Overvoltage shut down circuitry 

• Transformer isolated 24 V DC output 

• Class 1, DIV 2, Zone 2 applications 

• UL®, UL-C and CENELEC Certifications 

• G3 rating for harsh environments 

• Power for external field devices 

• Convection cooling (no fans) 

• Gasketed and sealed housing 

• Horizontal or vertical DIN rail mounting 

• Holes for bracket or wall mounting 

• Relay (form C) status alarm output

Wide-range Input Voltages

A high-efficiency input circuit automatically accepts either ac or dc input voltages. The 120/240 V AC or 125 V DC input circuit (P0922YU) provides a range of 85 to 265 V AC at 47 to 63 Hz operation (or 108 to 145 V DC) to meet world-wide power requirements.

High Efficiency

The sealed power supply has high efficiency (up to 95% for P0922YU and up to 81% for P0922YC) resulting in high reliability and low failure rates. They have a return-oninvestment (ROI) of less than two years based upon average electrical rates and load

Power for External Field Devices

The actual amount of power required in a standard 200 Series subsystem depends on the number of FBMs/Fieldbus Communication Modules (FCMs)/Field Control Processors (FCPs) being powered, the types of termination assemblies used, and whether internal or external powering is used for the individual field device(s). The FPS400-24 can also be used as a field power supply to power external field devices. However, for system integrity field devices and DIN rail baseplates should not be powered from the same FPS400-24.

Functional Specifications

Input Specifications

120/240 V AC or 125 V DC Power Supply (P0922YU) 

• Input Voltage Range: 85 to 265 V AC or 108 to 145 V DC, 125 V DC nominal

• Input Frequency Range: 47 to 63 Hz • Input Current: 5.6 A at 85 V AC input (RMS maximum) 2.5 A at 230 V AC input (RMS maximum) 

• Efficiency (at Maximum Power, 10A, 24V): 77% minimum at 85 V AC input 85% typical at 120 V AC input 92% typical at 230 V AC input 90% typical at 240 V AC input 

• Inrush Current: 20 A, at 110 V AC (peak at cold start) 40 A, at 220 V ac (peak at cold start) 

• Input Power: 453 W typical at 120 V AC, 50/60 Hz 439 W typical at 230 V AC, 60 Hz 441 W typical at 230 V AC, 50 Hz 24 V DC Power Supply (P0922YC) 

• Input Voltage Range: 18 to 35 V DC, 24 V DC nominal 

• Input Current: 19.5 A at 24 V DC input 

• Efficiency (at Maximum Output Power): 85% typical at 24 V DC input 

• Input Power: 468 W at 24 V DC input typica

Output Specifications

• Output Voltage: 24.0 V DC, ±0.2 V DC nominal factory setting  

• Voltage Line Regulation: 2.0% of Vout 

• Voltage Load Regulation: 2.0% of Vout 

• Ripple and Noise at 20 MHz: 100 mV (peak-to-peak), 10 mV (RMS maximum) 

• Temperature Coefficient: 0.025% per °C 

• Startup Time (Soft-Start): 3 s typical at 110 V AC input or 24 V DC, 5 s maximum 

• Overshoot: No overshoot at turn on, turn off, power failure or removal of short circuit 

• Load Transient Response: 50 to 100% LOAD CHANGE Recovery to within regulation limits within 50 ms Maximum output voltage excursion less than 5%

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice
  • PULS QS40.241 Power Supply Practical Guide
  • Eaton XV-102-L Touchscreen Installation Guide
  • Omron FZ5 Vision System Selection and Configuration Guide
  • Schneider TSX47 series PLC selection
  • ABB CS31 distributed debugging
  • OMRON H8PR electronic cam debugging
  • OMRON MX2 frequency converter debugging
  • GP477R Engineering Installation
  • Siemens AS-i SlimLine Diagnostic Guidelines
  • OMRON NS Series PT Remote Access
  • OMRON Z4M sensor precision measurement
  • HIMMERWERK SINUS High Frequency Induction Heating Selection
  • OMRON CP1E PLC Practical Selection Guide
  • OMRON ZFX-C Vision Sensor in Practical Use
  • OMRON ZFV Intelligent Sensor Practical Guide
  • OMRON CJ Series PLC Practical Guide
  • Murr SIRCO Isolation Switch Selection Guide
  • OMRON ZFX Vision Sensor Engineering Practice
  • REER ULISSE UNC Security Light Curtain Practice
  • Siemens S5-90U/95U Fault Diagnosis and Advanced Programming
  • OMRON CPM2C system fault diagnosis and maintenance
  • Yaskawa ∑ - V Servo Drive Debugging Guide
  • OMRON CP1H PLC Practical Manual
  • OMRON K-type PLC Maintenance Guide
  • PEPPERL+FUCHS SLVA-4Kplus Safety Light Curtain Guide
  • Yaskawa ∑ - II Servo Drive Debugging Guide
  • Yaskawa VS-616PC5/P5 frequency converter practical application
  • OMRON 3G3SV Inverter Practical Manual
  • Pro face GP370 Complete Guide
  • OMRON FQ2 Smart Camera Selection Guide
  • Practical Guide to Sony SH800 Sorter
  • OMRON Cam Positioner Complete Guide
  • KEB F4 Inverter Debugging Guide
  • OMRON CJ series PLC operation and maintenance essentials
  • Essentials of Schneider C60H-DC DC DC Protector
  • OMRON 3G3MV Inverter Practical Guide
  • Essentials of OMRON CQM1H PLC System
  • Essentials of ARD Elevator Emergency Rescue Device
  • SolaHD SDN-D rail power supply
  • OMRON C200H PLC Troubleshooting and Programming Essentials
  • Allen Bradley 1336 PLUS Inverter Practical Guide
  • OMRON 3G3KV frequency converter
  • OMRON NSJ Integrated Controller
  • Megatiker M4 Circuit Breaker Maintenance
  • OMRON ZX laser sensor maintenance
  • Saia PCD1 Controller Maintenance Guide
  • OMRON NT Series HMI Replacement and Maintenance
  • Yaskawa F7 Driver Maintenance and Replacement
  • Rockwell 1494 switch selection replacement
  • Omron NA Series HMI Connection Guide
  • Eaton CV Series PLC System Upgrade and Diagnosis
  • Eaton XV-102 HMI Installation and Troubleshooting
  • Siemens SINUMERIK measurement cycle configuration
  • ELAU PacDrive C600 Controller Integration Guide
  • ELAU PacDrive SM Servo Motor Application and Maintenance Guide
  • Bently Nevada Orbit 60 System Upgrade and Troubleshooting Guide
  • YOKOGAWA STARDOM FCN-RTU Controller
  • Fireye InSight II Marine Flame Scanner
  • How to install ABB VSC vacuum contactor?
  • Rexroth Bosch Group VT2000 Proportional Amplifier
  • ALSTOM ALSPA series frequency converter
  • ABB SPACOM replaces REX615
  • Meggitt C327895 Gas Metering Valve Technology
  • Application of MOOG G77x servo valve
  • WOODWARD 2301E Digital Speed Controller
  • ABB UNITOL 1010/1020 AVR Compact IGBT Automatic Voltage Regulator
  • ABB UNITOL 6000 excitation system
  • Rexroth Bosch Group HNC100 Hydraulic Shaft Control
  • Lenze 8400 Inverter Debugging Guide
  • Panning Vacuum Sensor Maintenance Guide
  • SOGEVAC Rotary Disc Pump Maintenance Guide
  • THERMOVAC MEMS Vacuum Gauge Guide
  • TTR 101 Vacuum Gauge Troubleshooting Guide
  • Honeywell Beam Smoke Detector Guide
  • TURBOVAC Molecular Pump Maintenance Guide
  • Troubleshooting of Leuze electronic DDLS 200 optical transmission
  • Lam Harmonic Drive Quick Replacement Guide
  • LZS power replacement and troubleshooting
  • MTL2000 series isolation barrier
  • Temposonics GB Sensor
  • Temposonics R Series Magnetostrictive Displacement Sensor Depth
  • Original inventor of M ü ller Co ax AG coaxial valve
  • Murrelektronik Automation Solution Complete Solution
  • Nabtesco RV series high-precision gearbox
  • NACHI Robot Full Series
  • Electro hydraulic proportional directional flow valve
  • NEC FC-9801X Industrial Computer
  • Mark VIeS Security System