Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • ABB IMDSO14 Digital Slave Output Module
    ❤ Add to collection
  • ABB IMDSO14 Digital Slave Output Module

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    ABB IMDSO14 is a high-precision digital slave output module designed for industrial distributed control scenarios. It belongs to the ABB AC800M and AC500 series PLC extension components and focuses on centralized control and decentralized output under a master-slave communication architecture. It adopts a standardized slave station design and can seamlessly connect to the main controller system through the industrial bus. It is designed to provide precise driving signals for digital actuators such as contactors, solenoid valves, and indicator lights. With high-speed bus response, high-density output channels, and reliable status feedback capabilities, it has become a key signal execution unit for large-scale automation systems such as automotive manufacturing and process industries.

    • ¥60547.00
      ¥62352.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:26.000KG
    • Quantity:
    • (Inventory: 99999)
Description

ABB IMDSO14 is a high-precision digital slave output module designed for industrial distributed control scenarios. It belongs to the ABB AC800M and AC500 series PLC extension components and focuses on centralized control and decentralized output under a master-slave communication architecture. It adopts a standardized slave station design and can seamlessly connect to the main controller system through the industrial bus. It is designed to provide precise driving signals for digital actuators such as contactors, solenoid valves, and indicator lights. With high-speed bus response, high-density output channels, and reliable status feedback capabilities, it has become a key signal execution unit for large-scale automation systems such as automotive manufacturing and process industries.


ABB IMDSO14 Digital Slave Output Module

Product Overview

ABB IMDSO14 is a high-precision digital slave output module designed for industrial distributed control scenarios. It belongs to the ABB AC800M and AC500 series PLC extension components and focuses on centralized control and decentralized output under a master-slave communication architecture. It adopts a standardized slave station design and can seamlessly connect to the main controller system through the industrial bus. It is designed to provide precise driving signals for digital actuators such as contactors, solenoid valves, and indicator lights. With high-speed bus response, high-density output channels, and reliable status feedback capabilities, it has become a key signal execution unit for large-scale automation systems such as automotive manufacturing and process industries.


Specification parameters

1. Core output parameters

Output channel configuration

16 independent digital outputs, supporting software switching between source/drain output modes

Load driving capability

The maximum output current per channel is 2A, and the total output current is ≤ 8A (which can drive small and medium-sized electromagnetic actuators)

Response speed

Bus instruction received to output action delay ≤ 1ms, channel switching time < 100 μ s

State feedback capability

Support real-time monitoring of output status for each channel, with feedback delay ≤ 500 μ s

2. Hardware and environmental parameters

Communication interface

1 x PROFINET interface (supporting real-time communication such as IRT), compatible with PROFINET IO slave protocol

Power supply specifications

24V DC dual circuit power supply (logic power supply 24V DC/0.5A, load power supply 24V DC/8A), with overcurrent protection

Environmental tolerance

Working temperature -25 ° C to 60 ° C, storage temperature -40 ° C to 85 ° C, relative humidity 5% -95% (no condensation)

Physical specifications

Size 120 × 80 × 60mm, weight 0.35kg, supports DIN rail installation, compatible with ABB standard I/O rack

3. Certification and compatibility

Certification: CE (EN 61131-2), UL 508 industrial safety certification, compliant with IEC 61010-1 and IEC 61800-3 standards

System compatibility: compatible with ABB AC800M DCS and AC500 PLC systems, supporting PROFINET communication with main controllers such as Siemens and Rockwell

Software compatibility: compatible with ABB Automation Builder V2.8 and above versions, supporting Function Block Diagram (FBD) configuration and diagnosis


Performance characteristics

High speed bus collaboration: Based on the PROFINET IO slave protocol design, it supports real-time communication with IRT at a bus transmission rate of 100Mbps, with a bus cycle as low as 1ms, ensuring synchronous control accuracy between 16 output channels and the main controller, and adapting to the collaborative requirements of high-speed production lines.

High density flexible output: The 16 independent output channels adopt a compact layout, and a single module can drive 16 small actuators, which increases the channel density by 30% compared to traditional modules; The software switching between source/drain modes does not require hardware jumpers and is suitable for the access requirements of actuators with different polarities.

Full channel status monitoring: Each output is equipped with an independent current detection and status feedback circuit, which can upload real-time channel on/off status, load current, and short-circuit fault information. The main controller can quickly locate the faulty channel through the bus, and the average fault troubleshooting time is shortened to less than 2 minutes.

Industrial grade reliability design: adopting optoelectronic isolation (2500V AC) and surge suppression circuit, which can resist electromagnetic interference and instantaneous overvoltage in industrial sites; The dual circuit power supply design ensures that the logic circuit and load drive operate independently, and the fluctuation of load power supply does not affect the stability of module communication.

Convenient configuration and expansion: Supports online configuration of output modes, fault thresholds, and address parameters through Automation Builder software, without the need for on-site debugging; 64 similar modules can be cascaded through PROFINET to achieve centralized control of 1024 digital output channels.


Working principle

This module operates based on the slave control logic of "bus instruction reception logic parsing driver output state feedback". The core process is as follows:

Bus communication stage: As a PROFINET IO slave station, it receives output control instructions (such as channel on/off signals) issued by the main controller (such as AC800M) through the bus interface, and after protocol parsing and verification, transmits them to the core processing unit.

Instruction parsing stage: The embedded MCU performs logical processing on control instructions, distinguishes the action requirements of 16 channels, generates corresponding drive signals based on preset output modes (source/drain), and activates the state monitoring circuit.

Load driving stage: The driving circuit converts the logic signal into a power signal and drives the contactor, solenoid valve, and other actuators to operate through the output terminal; Each channel is equipped with a built-in current limiting circuit, which automatically limits the current when the load current exceeds 2A to avoid overload damage.

State feedback stage: The current sensor and state detection circuit real-time collect the current value and on/off status of the output channel, and after digital processing, it is transmitted back to the main controller through the PROFINET bus, forming a closed-loop control link of "master slave actuator".

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Bonfiglioli EVOX CP Explosion proof Reducer: Quick Guide for Installation and Maintenance
  • Bonfiglioli C/A/F/S Reducer ATEX Installation and Maintenance Practice Guide
  • Bonfiglioli BXN/MXN Motor Installation and Brake Maintenance Complete Guide
  • Bonfiglioli VF-W IE2/IE3 Worm Gear Reducer: Energy Efficiency Selection and Application Practice Guide
  • Bonfiglioli VF-W Explosion proof Worm Gear Reducer: ATEX Selection and Installation Complete Guide
  • Selection and Calculation of Bonfiglioli RAN Right Angle Gearbox
  • Bonfiglioli Industrial Transmission System Selection Guide
  • Bonfiglioli EVOX Gearmotor Selection and Configuration Guide
  • Bonfiglioli CAFS Reducer Selection and Application Guide
  • Bonfiglioli C-A-F gearbox selection and maintenance
  • Bonfiglioli C Series ATEX Explosion proof Reducer Selection
  • Bonfiglioli BN-BE-BX Series Motor Selection Guide
  • Bonfiglioli BMD Servo Motor Selection and Configuration Guide
  • Selection of Bonfiglioli A-series servo reducer
  • Bonfiglioli AS Series Reducer Installation and Maintenance Guide
  • Bonfiglioli Active 401/201 Inverter Selection and Application Guide
  • Bonfiglioli EM-IO-04 Expansion Module Configuration Guide
  • Bonfiglioli EM-ENC-02 Expansion Module Engineering Configuration Guide
  • Bonfiglioli A-series gearbox selection and maintenance
  • Bonfiglioli Transmission and Automation Product Selection Reference
  • Bonfiglioli RAN series bevel gearbox selection and maintenance guide
  • Bonfiglioli ACTION 401/201 Inverter Engineering Integration Guide
  • Alcatel Lucent Stellar AP1301 Deployment and Performance Optimization
  • Alcatel Lucent ALE Wireless Handheld System Selection and Deployment Guide
  • In depth analysis of Alcatel Lucent MDR-8000 microwave system engineering technology
  • Alcatel 1660SM Multi Service Node Operations and Troubleshooting
  • Alcatel Lucent OmniSwitch 6850 Stacking and Security Configuration Guide
  • Alcatel Lucent 7750 SR Router High Availability Deployment and Troubleshooting
  • Alcatel 1600 Series SDH Equipment Operation and Maintenance Guide
  • Alcatel Lucent 9500 MPR Microwave Platform Deployment and Troubleshooting
  • Alcatel Lucent 7450 ESS High Availability Deployment and Operations Guide
  • Alcatel OmniPCX 4400 REFLEXES Phone Configuration Troubleshooting
  • Alcatel Lucent OmniSwitch 6850E Stacking Operations and Troubleshooting
  • Alcatel Lucent OmniSwitch 6450 Stacking and Troubleshooting Guide
  • Lucent Stinger DSLAM High Availability Deployment and Fault Recovery Complete Guide
  • Alcatel Lucent 1660SM Optical Transmission System Architecture and Business Bearer
  • ALCATEL-LUCENT 9500 MPR Microwave Packet Wireless System Performance
  • Atlas Copco MT Focus 6000 Controller Safety Specification and Electrical Grounding
  • Atlas Copco Power MACS 4000 Automated Tightening System Performance
  • Design and Protection of Constant Torque Application for Atlas Copco Neos Inverter
  • Atlas Copco Power Focus 8 Family Selection Configuration and Virtual Station Function Complete Explanation
  • Atlas Copco Power Focus 4000 Controller Safety Deployment and Electrical Grounding Specification
  • Atlas Copco Power Focus 3000 Controller Installation, Debugging, and Troubleshooting Guide
  • Atlas Copco Tensor S Tightening Tool Troubleshooting Guide
  • Application and maintenance of Atlas Copco SRTT-B torque sensor
  • Atlas Copco ACTA 4000 Torque Analyzer Operation and Calibration Guide
  • Atlas Copco Tensor STB Wireless Tightening Tool Deployment Guide
  • Atlas Copco Power Focus 4000 Configuration and Troubleshooting Manual
  • Atlas Copco Power Focus 6000 and Tensor STR System
  • Energy efficiency and selection of Atlas Copco ZR/ZT oil-free screw compressor
  • Atlas Copco PowerMACS 4000 Tightening Control System
  • Atlas Copco Elektronikon MK5 Controller Operation Guide
  • Atlas Copco Tensor ES and PF600 Tightening System
  • ADLINK STC2-AL/KL Industrial Control Tablet BIOS and Drivers
  • ADLINK STC-15W04 industrial tablet computer
  • ADLINK SP2-EHL Fanless Tablet Selection and Configuration Guide
  • ADLINK PXIS-2719A Chassis Deployment Monitoring Guide
  • ADLINK PXIe-9908 SMU Deployment and Configuration Guide
  • ADLINK PXIe-9852 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9848 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9834 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9529H Dynamic Signal Acquisition Configuration Guide
  • ADLINK PXIe-3988 Xeon Deployment Optimization Guide
  • ADLINK PXIe-3987/3977/3937 Deployment and Debugging
  • ADLINK PXIe-3987 Installation and Configuration Programming Guide
  • ADLINK-PXIe-3988-3987-3977-3937-TL Controller Deployment and Maintenance Guide
  • ADLINK PXI-2020/2022 Synchronous Acquisition Card Configuration and Synchronization Guide
  • ADLINK DAQ/PXI-2000 series synchronous acquisition card configuration and triggering
  • ADLINK PXES-2788 series chassis deployment and maintenance
  • ADLINK PXES-2785 18 Slot Gen3 Chassis Deployment and Maintenance Guide
  • ADLINK PXES-2780 18 Slot PXIe Chassis Deployment Configuration
  • ADLINK PXES-2596 Gen3 Chassis Installation and Maintenance Guide
  • ADLINK PXES-2590 Chassis Deployment and System Management
  • ADLINK PXES-2314T Chassis Deployment and Troubleshooting Guide
  • ADLINK PXES-2301 Chassis Installation Monitoring and Troubleshooting
  • ADLINK PCIe-U300 Series USB3 Vision Acquisition Card Deployment Guide
  • ADLINK PCIe PXIe-8565 Expansion Kit Remote Control and Compatibility
  • Installation and troubleshooting of ADLINK PCIe GIE74V four channel PoE acquisition card
  • ADLINK PCIe GIE7x Poe+Acquisition Card Configuration and Triggering Troubleshooting
  • Advanced triggering and multi card synchronization of ADLINK PCIe-CPL64V image acquisition card
  • ADLINK PCIe-CPL64 Image Acquisition Card Hardware Trigger and Encoder Application
  • Application and troubleshooting of ADLINK PCIe-8560/PXI-8565 expansion kit
  • ADLINK PCIe 8332/PCIe 8334/PCIe 8338 EtherCAT Motion Controller Multi axis Synchronous Control
  • ADLINK PCIe-7432 32 channel isolated I/O card interrupt and driver
  • ADLINK PCIe-7256 Industrial I/O Card Interruption and Relay
  • ADLINK PCIe-833x EtherCAT Motion Controller Debugging and Maintenance
  • ADLINK PCIe-10GPoE 10GigE Visual Acquisition Card Practical Use
  • ADLINK PCI-8254/8258 Motion Controller Debugging and Maintenance
  • Application and Maintenance of ADLINK PCI-8158 Multi axis Motion Control Card
  • ADLINK PCI-8134A Maintenance and Troubleshooting Guide
  • ADLINK PCI-7250 Series Relay Output Card Configuration and Protection Circuit Guide
  • ADLINK PCI-6308 Series Isolated Analog Output Card Configuration and Programming
  • ADLINK PanKonix Series HMI Panel Selection and Deployment Guide
  • ADLINK NuDAM-6100 Series I/O Module Deployment and Protocol Optimization
  • Deployment and Calibration of ADLINK NuDAM-6000 Data Acquisition Module
  • ADLINK NEON-2000-Ono Intelligent Camera Deployment and Trigger Optimization
  • ADLINK NuDAM-65xx Communication Module Networking and Configuration Guide
  • ADLINK NuDAM-60xx Series Digital I/O Module Deployment and Watchdog Optimization
  • ADLINK MXE-5300 Fanless Industrial Control Computer Deployment and Troubleshooting Manual
  • ADLINK MXE-310 edge computing Platform Hardware Installation and BIOS Tuning
  • ADLINK MXE-230 series Alder Lake platform industrial computer deployment and maintenance manual
  • ADLINK MXE-210 Compact Fanless Industrial Control Computer Hardware Deployment and Debugging Guide
  • ADLINK MXC-3300/3340 Embedded Industrial Control Computer Hardware Integration and Debugging Manual
  • ADLINK MXA-312M Edge AI Platform Hardware Integration and Debugging Guide
  • ADLINK MXA-200 IoT Gateway Hardware Installation and Linux System Debugging Complete Guide
  • ADLINK MVP-6200 Industrial Control Computer: PCIe Gen4 and PCI Hybrid Expansion
  • ADLINK MVP-6100 Industrial Control Computer: PCI/PCIe Expansion and Robust Design
  • ADLINK MVP-5200 Industrial Control Computer: High Performance Multi Display and TSN Network
  • ADLINK MVP-5100 Fanless Industrial Control Computer Deployment and Development Guide
  • ADLINK MVP-3100 and MVP-3120 Embedded Systems
  • ADLINK MNET-J3/S23/MIA/DA2/SAN Single Axis Module Installation and Wiring Guide
  • ADLINK MNET-4XMO/C Motion Module Installation and Debugging Guide
  • ADLINK MCM-216/218 Edge DAQ Deployment Configuration Guide
  • ADLINK LPCIe-8124-C Encoder Card Trigger Configuration Guide
  • ADLINK IM/OM Series Industrial Display Installation and Debugging Guide
  • ADLINK GW-01 Industrial IoT Gateway Configuration and Debugging Guide
  • EURESYS Grablink Collection Card Selection and Trigger Configuration Guide
  • ADLINK Express HL Module Selection and Heat Dissipation Configuration Guide
  • ADLINK EOS-2000 Visual System Installation and Troubleshooting
  • ADLINK EOS-1200 Installation, Configuration, and Troubleshooting
  • Application and Configuration of ADLINK ECS-8582-4S Extension System
  • ADLINK DIN-814P-A4 Panasonic servo adapter board configuration
  • ADLINK DIN-814M-J3A Mitsubishi servo adapter board configuration
  • ADLINK DIN-814-GP Universal Adapter Board Configuration
  • Application and Configuration of ADLINK DIN-812M Adapter Board
  • Application and Configuration of ADLINK DIN-814Y Adapter Board
  • ADLINK DAQ/DAQE/PXI-250x waveform generation complete guide
  • ADLINK DAQ/DAQE/PXI-220x acquisition card fully configured