  • GE IS200JPDGG1A Power Distribution System Feedback I/O Module
    ❤ Add to collection
  • GE IS200JPDGG1A Power Distribution System Feedback I/O Module

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS200JPDGG1A Power Distribution System Feedback I/O Module

    • ¥40575.58
      ¥40253.25
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:6.750KG
    • Quantity:
    • (Inventory: 12)
Description

GE IS200JPDGG1A Power Distribution System Feedback I/O Module


GE IS200JPDGG1A Power Distribution System Feedback I/O Module

Part Number IS200JPDGG1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS200JPDGG1A is a power distribution module developed by GE. It is a part of Mark VIe control system. The Power Distribution board plays a critical role in the control system by efficiently distributing power to various components. It manages both control power and wetting power, along with providing sensing circuitry for ac distribution. The board receives 28 V dc input power from external ac/dc or dc/dc converters for control power distribution. 

It acts as a central hub, distributing power to the control system while ensuring fuse protection for all 28 V dc outputs. PHYSICAL ARRANGEMENT Typically positioned within the cabinet in a manner that allows convenient access for maintenance and monitoring. Connector P2, located on the JPDG, serves as the interface for receiving feedback signals from other power distribution boards within the system. These signals are then transmitted to the PPDA for analysis and monitoring purposes. When installed, it is mounted vertically within the cabinet, ensuring efficient utilization of space while maintaining accessibility. Adjacent to the module, the PPDA I/O pack is connected, facilitating seamless communication and data exchange between the two components. 

One notable advantage of this arrangement is the clear visibility of all indicator lights present on the PPDA I/O pack. These lights provide essential information regarding the status and performance of the power distribution system, allowing operators to quickly identify any issues or anomalies for prompt resolution. GROUND FAULT DETECTION The board is equipped with features to facilitate ground fault detection within the power distribution system. It utilizes a wetting voltage DC bus configuration that maintains ground potential at the center through the use of a high-resistance connection. 

This setup enables the detection of ground faults by monitoring the voltage levels of both the positive and negative buses concerning ground. To achieve thism, it incorporates separate voltage feedback sensing mechanisms for the positive and negative power lines concerning ground. Feedback signals from these sensing circuits are then relayed to the control system, enabling the detection and notification of ground faults. The sensitivity of ground fault detection and the magnitude of ground fault currents are determined by the resistance used to center the DC bus on ground. Within the JPDG, centering resistors are integrated and can be selected via jumper JP1. The presence or absence of centering resistance elsewhere in the system influences the configuration of this jumper. 

Responsible for providing the centering function, jumper JP1 should be closed to activate the centering resistors within the board. However, if centering resistance is implemented elsewhere in the system, JP1 should remain open. In scenarios where both the JPDG and a JPDE are employed for distributing wetting power, only one of the two boards should have its JP1 jumper closed to avoid redundancy. INSTALLATION Mounting Procedure: The board is vertically base-mounted onto a metal bracket within the control cabinet used by the Power Distribution Module (PDM). 

It is securely attached with four screws, utilizing mounting holes located at the top and bottom of the module base. While the location within the cabinet is not critical, distribution boards are typically mounted low to facilitate grounding. CONNECTION POINTS AND POWER INPUTS: Diagnostic Connector (P2): A 50-pin diagnostic connector, P2, is mounted on the bottom of the board. Power Inputs: Control Power Input (28 V DC): Either one or two 28 V dc control power input connections are made through connectors JR and JS. It features a common 28 V dc bus for efficient power distribution. Wetting Power Input (24/48 V DC): One or two 24 V dc wetting power input connections, or alternatively one or two 48 V dc input connections, are made through connectors JPS1 and JPS2. Includes a com mon 24/48 V dc wetting voltage bus. Integration with PPDA I/O Pack: The PPDA I/O pack is plugged into connector JA1 on the board. 

It is securely fastened to the base using an angle bracket and held in place with nuts threaded onto studs that are permanently attached to the base for this purpose. Diagnostic Feedback Routing: Diagnostic feedback inputs from other distribution boards are routed via a 50-pin ribbon cable attached to connector P2. This facilitates comprehensive monitoring and diagnostic capabilities within the control system.

Ease of Use

• Simple and powerful instruction set 

• One-axis or two-axis motion programs with synchronized block start 

• Program support for a short motion program (called Program Zero) which can be created in the MS-DOS programming software configuration function 

• Nonvolatile (flash) storage for 10 programs and 40 subroutines 

• User scaling of programming units (in Standard mode only) 

• Generic programming using command parameters as operands for Acceleration, Velocity, Move and Dwell commands 

• Configured with MS-DOS configuration software 


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Yokogawa AIP830 Single Circuit Operation Keyboard
  • Yokogawa RAMC flowmeter selection and troubleshooting
  • YASKAWA GA500 frequency converter troubleshooting
  • TRACO TIS600 power supply
  • Sigmatek ETV-0851 Control Panel Troubleshooting
  • Allen Bradley Quest AN-X2-AB-DHRIO Remote I/O Adapter Integration and Troubleshooting
  • Meggitt RPS6U power supply
  • Kongsberg RCU500 Controller Integration and Fault Diagnosis Guide
  • KBAC series frequency converter installation and fault diagnosis guide
  • EXOR effectiveness View eV058 series HMI industrial panel
  • Emerson OCR3000 Controller Troubleshooting Guide
  • Emerson Ovation OCR1100 Controller Maintenance and Troubleshooting
  • Elmo G-TUB30 Driver Troubleshooting Guide
  • Troubleshooting and Optimization of Basler A400 Series Camera
  • Troubleshooting and Maintenance of Automated Logic I/O Expansion Module
  • Troubleshooting and Maintenance of Aerotech UNIDEX 100 Controller
  • ADVANEST R6144 calibration source troubleshooting
  • Troubleshooting and Calibration of ABB Millmate Tension Gauge
  • ABB NGC8206 natural gas chromatograph troubleshooting and maintenance
  • ABB AO2040-CU Ex Explosion proof Analyzer Troubleshooting
  • ABB PFEA113 Tension Controller Troubleshooting Guide
  • ABB PFEA111/112/122 Tension Controller Troubleshooting Guide
  • ABB LS4000 laser analyzer
  • ABB SPAU 341 C Voltage Regulator Troubleshooting Guide
  • Analysis and Fault Diagnosis of ABB V-Contact VSC Medium Voltage Contactor
  • ABB UNITOL 1020 Compact Digital Excitation Regulator AVR Replacement and Troubleshooting
  • ABB UNITROL 1000 excitation system replacement and troubleshooting
  • ABB SYNC HROTACT 5 synchronization module troubleshooting and replacement
  • ABB SYNC HROTACT 5 Synchronization Device Replacement and Troubleshooting Guide
  • ABB Symphony Plus Module Replacement and Upgrade Guide
  • ABB S900 I/O Hazardous Area Deployment and Maintenance
  • ABB System 800xA Operations and Troubleshooting
  • ABB PCS6000 Troubleshooting and Module Replacement Guide
  • ABB PCS 8000 pumped storage excitation
  • ABB Procontrol P13 Bus Coupling Upgrade Guide
  • ABB NextMove ESB-2 Fault Diagnosis and Configuration Practice
  • ABB MEGADRIVE-LCI Maintenance and Selection Practice
  • ABB MEGADRIVE LCI Transmission Vibration Suppression
  • ABB MEGADRIVE LCI Water Cooling Troubleshooting and Maintenance Guide
  • Practical Maintenance and Common Troubleshooting of ABB DCS880
  • ABB SDCS-IOB-3 Replacement and Troubleshooting
  • ALSTOM MAE99-04 Serial Interface Terminal Panel Maintenance and Troubleshooting
  • Installation and Maintenance of ALSTOM ALSPA MV3000 Handheld Operator
  • Maintenance and commissioning of ABB KPM KB2 paper breakage detector
  • Maintenance and troubleshooting of ABB SCC-K converter
  • ABB SCC Gas Preprocessing System Maintenance and Selection Guide
  • ABB NGC8209 gas chromatograph maintenance
  • Maintenance and troubleshooting of ABB DCS DC speed controller
  • ABB ASTAT Crane Controller Maintenance and Debugging Guide
  • ABB ACS800 TIM foil IGBT
  • ABB LS25 laser analyzer troubleshooting
  • ABB REM54 motor terminal troubleshooting
  • ABB REL670 distance protection and troubleshooting
  • ABB SUE3000 switching device troubleshooting
  • ABB REF630 feeder protection
  • ABB REF620 (Relion 620 series) feeder protection and measurement device
  • ABB E1B-A Circuit Breaker
  • ABB FCU400-IR temperature measurement system troubleshooting
  • ABB TZIDC-200 locator configuration and troubleshooting
  • ABB DHH805-A Handheld Operator Configuration and Activation Guide
  • ABB SACO 16D1 alarm device replacement and troubleshooting
  • ABB 5SHY3545L0016 IGCT module replacement guide
  • ABB S600 I/O Module Replacement and Troubleshooting Guide
  • ABB NextMove e100 motion controller troubleshooting guide
  • Rockwell PowerFlex 700 Inverter Replacement and Troubleshooting Guide
  • Allen Bradley 1762-OW16 Output Module
  • Allen Bradley IntelliVAC 1503VC Series E Control Module
  • Allen‑Bradley IntelliVAC ™ 1503VC contactor control module
  • Woodward SOGAV 250 solenoid valve drives gas intake valve for troubleshooting
  • Woodward easyYgen-3500XT-P1 obstacle removal
  • Woodward CPC-II electro-hydraulic current pressure converter
  • UniOP ePALM10 Handheld HMI
  • TMEIC TMdrive-30 frequency converter
  • TEWS TVME200 Carrier Board Configuration and Troubleshooting Guide
  • TDK Alpha 400 Power Troubleshooting Guide
  • STUCKE SYMAP relay
  • Deployment and troubleshooting of Softing CAN-AC2-PCI interface card
  • Installation, Maintenance, and Troubleshooting of Siemens C7-623/624
  • Foxboro Compact 200 Series 16 Slot Bottom Plate Deployment and Maintenance Guide
  • Foxboro 84F/84W Vortex Flow Meter Selection and Debugging Guide
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller
  • DATA PATTERNS DP-VME-5114 Dual PMC Carrier Board Integration and Troubleshooting
  • CMZ SVM1608 Intelligent Servo Driver
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide
  • SUMITOMO ELECTRIC AC1135U Small Parts Turning Application Guide
  • SUMITOMO ELECTRIC AC1030U Precision Machining Selection and Practice for Small Parts
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection
  • BENDER RCMA475LY Residual Current Monitoring
  • BENDER IRDH575 Insulation Monitoring
  • BENDER IRDH265 Insulation Monitoring and Debugging
  • Bender RCMA475LY residual current monitor debugging
  • Beckwith Electric M-3425A Generator Protection Relay Debugging Guide
  • Automated MEX816U Expander Troubleshooting Guide