  • GE IS200MVRAH1A I/O Interface Board
    ❤ Add to collection
  • GE IS200MVRAH1A I/O Interface Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS200MVRAH1A I/O Interface Board

    • ¥35787.00
      ¥35784.25
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.500KG
    • Quantity:
    • (Inventory: 87)
Description

GE IS200MVRAH1A I/O Interface Board


GE IS200MVRAH1A I/O Interface Board

Part Number IS200MVRAH1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS200MVRAH1A is an I/O Interface Board developed by GE. It is a part of Mark VIe control system. The MVRA is an I/O (Input/Output) board within the PMVE (Process Management and Vitality Equipment) system. The board communicates with the PMVE system via the high-speed serial link (HSSL). This communication protocol ensures efficient data transfer between the board and other components of the PMVE system, facilitating seamless integration and operation. 

 FEATURES Specialized Code and Control Mechanisms: The PMVE system contains specialized software code specifically tailored for the MVRA board. This code governs the communication and control of the analog and digital I/O functionalities. It enables the PMVE system to interact with and manage the MVRA board effectively. Customizable Configuration Parameters: Configuration parameters are available to customize the operation of the MVRA board according to specific requirements and applications. 

These parameters allow users to tailor the functionality of the board to suit the unique needs of their system, ensuring optimal performance and compatibility. Functional Replacement for Mark V TCQA and IOMA Boards: The board serves as a functional replacement for the Mark V TCQA (Turbine Control Quadruple Analog) and IOMA (Input/Output Multifunction Analog) boards. By incorporating advanced technology and enhanced functionalities, the MVRA board offers improved performance and reliability compared to its predecessors. ANALOG AND DIGITAL I/O CAPABILITIES Thermocouples (Simplex): Supports the input of thermocouple signals, providing temperature measurement capabilities. 

This feature allows the system to monitor temperature variations in critical components or processes, ensuring operational safety and efficiency. Servos and LVDTs: Facilitates the connection of servos (servo motors) and LVDTs (Linear Variable Differential Transformers), enabling precise control and monitoring of mechanical movements and positions. This capability is vital for applications requiring accurate motion control and feedback. Pulse Rates: Capable of measuring and processing pulse rate signals, offering the ability to monitor the frequency or rate of events such as rotations, pulses, or cycles. This functionality is essential for applications involving speed control or event monitoring. Proximeters: Supports proximeter inputs, allowing the system to detect the presence or proximity of objects or materials. Proximeters are commonly used for proximity sensing in industrial applications, such as detecting the position of moving parts or objects. Analog Inputs and Outputs: Provides analog input and output channels, enabling the system to interface with various analog sensors, actuators, and control devices. 

This capability allows for the monitoring of analog signals and the generation of analog control signals for precise system control. PTR Relays: Supports PTR (Programmable Time Relay) relays, which are used for time-delayed switching or control functions. PTR relays provide flexibility in timing operations, allowing for the implementation of sequential or time-dependent control logic. Bus and Gen Voltage: It can monitor bus and generator voltages, providing essential information about the electrical power distribution and generation systems. This capability enables the system to ensure voltage stability and reliability in power generation and distribution applications. CPD and Megawatt: Facilitates monitoring of CPD (Condensate Pump Discharge) and Megawatt signals, offering insights into critical parameters related to power generation and distribution processes. 

This capability allows for effective monitoring and control of power plant operations. INSTALLATION PRE-INSTALLATION PRECAUTIONS Power Shutdown: Before beginning the installation process, ensure that power is completely removed from the core system to prevent any electrical hazards or damage to the components. INSTALLATION STEPS Disconnect Cables: Carefully detach all ribbon cables and power cables from the connectors on the existing board. Pay attention to the orientation of the cables - the red or blue stripes should always be on the left side. Release Board Tabs: Hold the board in place securely, then press up on the three top and three bottom tabs to release the board from its mounting position. 

Remove Old Board: Once the tabs are released, gently remove the old board from its mounting location and place it in a static bag to prevent electrostatic discharge. Prepare New MVRA: Take the new board out of its static bag, ensuring proper handling to prevent any damage. Install New Board: Carefully position the new board in the vacant slot, aligning it with the mounting guides or rails. Press down firmly to secure the board in place, ensuring that all tabs click into position. Reconnect Cables: Reattach the ribbon cables and power cables to the corresponding connectors on the new board. 

Again, ensure that the cables are oriented correctly, with the red or blue stripes on the left side. Connect HSSL Link Cable: Once the board is securely installed, connect the HSSL link cable from the PMVE system to the designated port on the MVRA board. This cable facilitates communication between the PMVE and the board. POST-INSTALLATION VERIFICATION Visual Inspection: Double-check all cable connections and ensure that the board is securely mounted in its designated slot. Power Restoration: After confirming proper installation, restore power to the core system and verify that the board initializes correctly.

SPECIFICATIONS

Part No.: IS200MVRAH1A
Manufacturer: General Electric
Country of Manufacture: United States of America (USA)
Size: 13 in. x 7 in.
Temperature rating: 0 to 60 oC
Number of Channels: 13
Product Type: I/O Interface Board
Availability: In Stock
Series: Mark VIe


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • DEIF TCM-2 thyristor control module: Wind power cut in control engineering guide
  • DEIF MVR-200 Medium Voltage Relay: Installation and Wiring Engineering Guide
  • DEIF MDR-2 Differential Relay: Engineering Guide for Generator Differential Protection
  • DEIF Delomatic 3 AOM: Engineering Guide for Analog Output Modules
  • DEIF AGI 400 Graphic Interface: Ship and Industrial HMI Solution
  • DEIF BRW-1 Marine Instruments: Installation and Calibration Guide for Offshore Bridge Indicators
  • DEIF AGC 200 Controller: Quick Deployment and Configuration Guide for Generator Sets
  • DEIF AGC-2 Controller: The Ultimate Guide to Automatic Control and Protection of Generator Sets
  • ABB SPA-ZC400 Gateway: REM54x Access to IEC 61850 Ultimate Engineering Guide
  • ABB REM 543/545 Terminal
  • Modular Architecture Analysis of DEIF PPU 300 Ship Generator Controller
  • DEIF DM-4 Marine&Offshore Ship Power Management System
  • Detailed Explanation of DEIF Delomatic Generator Control System Architecture
  • DEIF AGC-4 Mk II Generator Controller Depth Configuration Guide
  • DEIF AGC-4 Generator Controller Configuration and Debugging Guide
  • DEIF PPM Power Management System Operation and Troubleshooting
  • Installation and wiring of DEIF Multi line 2
  • Practical configuration and maintenance of Beckwith M-6280 capacitor bank controller
  • Beckwith M-3311 Transformer Protection Relay Setting and Engineering Application
  • Beckwith M-3311A Transformer Protection Relay Configuration and Optimization Guide
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit
  • Installation and I/O configuration of DEIF PPM-3 power management module
  • Beckwith M-3520 Interconnection Protection Relay
  • Beckwith M-3430 Generator Protection Relay
  • Beckwith M-2293B adapter panel replacement GE regulator guide
  • Selection and Networking of Beckwith M-2001C Digital Voltage Regulating Controller
  • Beckwith M-2001B Digital Voltage Regulating Controller
  • Beckwith M-0388/M-0389 Synchronous Inspection Relay Application Guide
  • Beckwith M-0193B Synchronizer Debugging and System Integration Guide
  • Beckwith M-0115A Parallel Balance Module Debugging Guide
  • Beckwith M-0067E On Load Voltage Regulating Controller Selection and Debugging Guide
  • Debugging and Fault Handling of Beckwith M-4272 Digital Busbar Conversion System
  • Beckwith M-3311A Transformer Protection Relay Debugging Guide
  • Beckwith M-3425A Generator Protection Relay Debugging Guide
  • Setting and troubleshooting of Basler BE1-27/59 voltage relay
  • Debugging and troubleshooting of Basler AVC63-12/AVC125-10 voltage regulator
  • Basler L301kc Line Array Camera Technology and Troubleshooting
  • Selection and Debugging of Basler CBS 212A Current Boosting System
  • Selection and commissioning of Basler BE3-25 synchronous inspection relay
  • Basler BE1-32R/32O/U Direction Power Relay Setting and Testing Guide
  • Basler PRS 250 Synchronous Relay Maintenance and Replacement Guide
  • Basler piA2400-17gc Industrial Camera Replacement and Optimization Guide
  • Basler BE1-11g Generator Protection System
  • Basler VR63-4C/UL Voltage Regulator
  • Basler BE1-DFPR feeder protection relay
  • Basler CBS 310/320 Current Boosting System
  • Basler UFOV 250A/260A protection module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F Regulator
  • Basler DECS-400 excitation system
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection
  • Basler SSR Static Voltage Regulator: A Complete Guide to Debugging and Troubleshooting
  • Basler SR4A/SR8A Voltage Regulator: Detailed Debugging and Troubleshooting Explanation
  • Basler BE2000E Voltage Regulator: Replacement and Application Details
  • Basler DECS-2100 Excitation System: Modular Upgrade and Engineering Application
  • Basler BE1-851 Overcurrent Protection System: A Complete Guide to Professional Debugging and Troubleshooting
  • Basler APR 63-5 Voltage Regulator: Professional Debugging and Troubleshooting Guide for Industrial Generator Excitation Systems
  • Basler BE1-FLEX Protection System: A Complete Guide to Professional Installation, Configuration, and Troubleshooting
  • Debugging and Testing of Basler BE1-700 Relay
  • Basler BE1-87B busbar differential setting test
  • Basler BE1-40Q demagnetization relay setting test
  • Basler BE1-60 Voltage Balance Relay Setting Test
  • Basler BE1-47N Relay Field Setting and Testing Guide
  • Basler BE1-81O/U Frequency Relay: On site Debugging and Protection Configuration Guide
  • Basler BE1-11f Feedline Protection System Debugging and Troubleshooting Guide
  • Basler DECS-250 Excitation System: Installation, Configuration, and Troubleshooting Practice Guide
  • Basler DECS-100 Digital Excitation System Debugging Guide
  • Application Guide for Basler BE1-BPR Circuit Breaker Protection Relay
  • Basler BE1-50/51B-255 Replacement CO Relay Guide
  • Basler BE1-25 synchronous inspection relay principle and testing
  • Basler BE1-51 Time Overcurrent Relay Debugging Guide
  • Practical Guide to Basler DECS-300 Digital Excitation System
  • Mitsubishi FX Series PLC Data Communication Practical Manual
  • Selection of Hirschmann cSCALE S6/C8 Mobile Safety Controller
  • Hirschmann OZD Profi G12D repeater explosion-proof installation configuration
  • Hirschmann OCTOPUS OS20/24 Switch Installation Power Supply
  • Hirschmann RS20/30/40 Switch Selection and PoE Deployment
  • Hirschmann EAGLE One Firewall Installation and Configuration Guide
  • Hirschmann MACH102 Switch Installation and Power Supply Guide
  • Hirschmann MICE MS20/MS30 Installation and DIP Configuration
  • Hirschmann BOBCAT BRS Switch Installation and Power Supply Guide
  • Hirschmann RSB20 Switch Deployment and Redundant Configuration
  • Hirschmann RS20 Basic Switch Installation and Debugging Guide
  • BECKHOFF EP20xx/EP28xx Output Module Installation and Debugging Guide
  • BECKHOFF EL5102 Encoder Terminal Debugging and Troubleshooting
  • BECKHOFF CU8803 Launch Box Installation and Explosion proof Guide
  • BECKHOFF CU20xx/CU22xx Switch Installation and Troubleshooting
  • BECKHOFF AMP8000 Servo Drive Installation and Debugging Manual
  • BECKHOFF EL2911 Safety Feed Terminal Debugging Guide
  • BECKHOFF EL600x/EL602x Serial Port Module Debugging Manual
  • BECKHOFF CP6700 Panel PC Installation and Maintenance Manual
  • BECKHOFF CP70xx panel maintenance and troubleshooting
  • BECKHOFF CP29xx Panel Installation and Troubleshooting
  • Beckhoff C6650-0060 Industrial Control Computer Hardware Architecture and RAID Data Security
  • Beckhoff BK1120/BK1250 EtherCAT Coupling Debugging and KL Terminal Parameterization Complete Guide
  • Beckhoff CX20x0 Embedded Controller Hardware Maintenance and Troubleshooting Complete Manual
  • Beckhoff CP77xx Panel PC Hardware Maintenance and Troubleshooting Complete Guide
  • Beckhoff EL41xx Analog Output Terminal Deep Analysis: Parameter Configuration, Fault Diagnosis, and Firmware Compatibility Guide
  • Beckhoff C63xx industrial computer power supply and shutdown configuration
  • Beckhoff C6920 Industrial Control Computer Selection and Expansion Guide
  • Beckhoff CU8800 USB extender diagnostic guide
  • Beckhoff AX2000 Shutdown Braking and Debugging
  • Beckhoff AX8000 servo installation fuse selection
  • Beckhoff CP27xx Multi finger Touch PC Maintenance
  • Beckhoff CP69xx long-distance transmission and installation
  • Beckhoff CP60xx remote deployment and maintenance
  • Beckhoff CP72xx Installation and Maintenance Complete Manual
  • Beckhoff CP78xx Installation and Troubleshooting Guide
  • Beckhoff CP39xx Control Panel
  • Beckhoff CX8110 Embedded PC
  • Beckhoff CX50x0 series DIN rail embedded industrial PC
  • Beckhoff CP62xx panel PC
  • BECKHOFF C6030 Industrial Control Computer
  • UniOP ePAD32B/ePAD33B/ePAD33BT Industrial HMI
  • UniOP ePAD05/06 Human Computer Interface
  • UniOP ePAD03/04 Human Computer Interface
  • UniOP BKDR-46-0045 Human Machine Interface
  • UniOP BKDR-16 human-machine interface
  • Beckwith M-3425A Relay Guide
  • Basler DECS-200-2L excitation system
  • Basler DECS-250 Excitation System Debugging Guide
  • HA-800A Servo Drive Debugging Guide
  • JUMO dTRANS p35 Manual