  • GE IS200MVRAH1A I/O Interface Board
    ❤ Add to collection
  • GE IS200MVRAH1A I/O Interface Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS200MVRAH1A I/O Interface Board

    • ¥35787.00
      ¥35784.25
      ¥35787.00
      ¥35787.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.500KG
    • Quantity:
    • (Inventory: 87)
Description

GE IS200MVRAH1A I/O Interface Board


GE IS200MVRAH1A I/O Interface Board

Part Number IS200MVRAH1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS200MVRAH1A is an I/O Interface Board developed by GE. It is a part of Mark VIe control system. The MVRA is an I/O (Input/Output) board within the PMVE (Process Management and Vitality Equipment) system. The board communicates with the PMVE system via the high-speed serial link (HSSL). This communication protocol ensures efficient data transfer between the board and other components of the PMVE system, facilitating seamless integration and operation. 

 FEATURES Specialized Code and Control Mechanisms: The PMVE system contains specialized software code specifically tailored for the MVRA board. This code governs the communication and control of the analog and digital I/O functionalities. It enables the PMVE system to interact with and manage the MVRA board effectively. Customizable Configuration Parameters: Configuration parameters are available to customize the operation of the MVRA board according to specific requirements and applications. 

These parameters allow users to tailor the functionality of the board to suit the unique needs of their system, ensuring optimal performance and compatibility. Functional Replacement for Mark V TCQA and IOMA Boards: The board serves as a functional replacement for the Mark V TCQA (Turbine Control Quadruple Analog) and IOMA (Input/Output Multifunction Analog) boards. By incorporating advanced technology and enhanced functionalities, the MVRA board offers improved performance and reliability compared to its predecessors. ANALOG AND DIGITAL I/O CAPABILITIES Thermocouples (Simplex): Supports the input of thermocouple signals, providing temperature measurement capabilities. 

This feature allows the system to monitor temperature variations in critical components or processes, ensuring operational safety and efficiency. Servos and LVDTs: Facilitates the connection of servos (servo motors) and LVDTs (Linear Variable Differential Transformers), enabling precise control and monitoring of mechanical movements and positions. This capability is vital for applications requiring accurate motion control and feedback. Pulse Rates: Capable of measuring and processing pulse rate signals, offering the ability to monitor the frequency or rate of events such as rotations, pulses, or cycles. This functionality is essential for applications involving speed control or event monitoring. Proximeters: Supports proximeter inputs, allowing the system to detect the presence or proximity of objects or materials. Proximeters are commonly used for proximity sensing in industrial applications, such as detecting the position of moving parts or objects. Analog Inputs and Outputs: Provides analog input and output channels, enabling the system to interface with various analog sensors, actuators, and control devices. 

This capability allows for the monitoring of analog signals and the generation of analog control signals for precise system control. PTR Relays: Supports PTR (Programmable Time Relay) relays, which are used for time-delayed switching or control functions. PTR relays provide flexibility in timing operations, allowing for the implementation of sequential or time-dependent control logic. Bus and Gen Voltage: It can monitor bus and generator voltages, providing essential information about the electrical power distribution and generation systems. This capability enables the system to ensure voltage stability and reliability in power generation and distribution applications. CPD and Megawatt: Facilitates monitoring of CPD (Condensate Pump Discharge) and Megawatt signals, offering insights into critical parameters related to power generation and distribution processes. 

This capability allows for effective monitoring and control of power plant operations. INSTALLATION PRE-INSTALLATION PRECAUTIONS Power Shutdown: Before beginning the installation process, ensure that power is completely removed from the core system to prevent any electrical hazards or damage to the components. INSTALLATION STEPS Disconnect Cables: Carefully detach all ribbon cables and power cables from the connectors on the existing board. Pay attention to the orientation of the cables - the red or blue stripes should always be on the left side. Release Board Tabs: Hold the board in place securely, then press up on the three top and three bottom tabs to release the board from its mounting position. 

Remove Old Board: Once the tabs are released, gently remove the old board from its mounting location and place it in a static bag to prevent electrostatic discharge. Prepare New MVRA: Take the new board out of its static bag, ensuring proper handling to prevent any damage. Install New Board: Carefully position the new board in the vacant slot, aligning it with the mounting guides or rails. Press down firmly to secure the board in place, ensuring that all tabs click into position. Reconnect Cables: Reattach the ribbon cables and power cables to the corresponding connectors on the new board. 

Again, ensure that the cables are oriented correctly, with the red or blue stripes on the left side. Connect HSSL Link Cable: Once the board is securely installed, connect the HSSL link cable from the PMVE system to the designated port on the MVRA board. This cable facilitates communication between the PMVE and the board. POST-INSTALLATION VERIFICATION Visual Inspection: Double-check all cable connections and ensure that the board is securely mounted in its designated slot. Power Restoration: After confirming proper installation, restore power to the core system and verify that the board initializes correctly.

SPECIFICATIONS

Part No.: IS200MVRAH1A
Manufacturer: General Electric
Country of Manufacture: United States of America (USA)
Size: 13 in. x 7 in.
Temperature rating: 0 to 60 oC
Number of Channels: 13
Product Type: I/O Interface Board
Availability: In Stock
Series: Mark VIe


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice