GE IS200SPIDG1A - TCSA ASSEMBLY MARK VIES
Part Number IS200SPIDG1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI Function Module Availability In StockIS200SPIDG1A is a PROFIBUS Master Gateway Terminal Board manufactured and designed by General Electric as part of the Mark VIe Series used in Distributed Control Systems. The I/O pack is mounted on the PROFIBUS Master Gateway Terminal board (SPIDG1A), which also provides an electronic ID. As the PROFIBUS connection is established to the DE-9 D-sub receptacle connector that is exposed on the side of the I/O pack, that connection's only interface is with the I/O pack itself. Indicator LEDs on the I/O pack enable visual diagnostics. IS200SPIDG1A Installation Mount the SPID terminal board firmly.
Directly connect the PPRF to the connector on the terminal board. Repeat steps 1 and 2 for hot-backup configurations with a second SPID and PPRF. Using the threaded inserts next to the Ethernet ports, mechanically secure the packs. The inserts attach to a mounting bracket made especially for the type of terminal board. In order to prevent the DC-37 pin connector between the terminal board and the pack from being forced at an angle, the bracket needs to be changed.
Once during the course of the product's life will this change be necessary? Depending on the setup of the machine, connect either one or two Ethernet wires. The pack can use either port to function. The R controller's network should be connected to ENET1 if dual connections are needed, however, the PPRF is not Ethernet connection-sensitive and will negotiate good operation via either port. The PROFIBUS cable should be plugged in and secured to the DE-9 D-sub receptacle connection.
The PROFIBUS must be terminated on both ends in accordance with PROFIBUS specifications. Connect the connector on the pack's side with power. The connector does not need to be inserted with the cable's power disconnected. The PPRF features a built-in soft-start feature that limits current inrush when power is applied. To set up the I/O pack and PROFIBUS as necessary, use the ToolboxST program. Operation A fast CPU with flash memory and RAM. Two connectorized, totally independent 10/100 Ethernet ports. A hardware reset circuit and watchdog timer. A temperature sensor inside. LEDs that display status. The capacity to read IDs on other boards through electronic means. An input power connector with a current limiter and a soft start. Local power supplies, with monitoring and sequencing.Module manufactured by General Electric as part of the Mark VI/VIe Series used in gas turbine sppedtronic control system
Features
Single slot CPU
Provides 1 Mbyte of battery-backed memory in the same slot (up to 512 Kbytes available for use by ladder diagram application program) Supports floating point calculations
Up to 12K discrete inputs and outputs (any mix - simplex mode only); 2048 voted discrete inputs, 2048 voted discrete outputs Up to 8K analog inputs (simplex mode only) and 8K analog outputs (simplex mode only); 1024 voted analog inputs
0.4 microseconds per boolean function
64 MHz, 80486DX2 microprocessor
Supports IC660/IC661 I/O (and IC697 I/O in simplex mode only)
Programmed by MS-DOS, or Windows
software products running on Windows
95 or Windows NT
over Ethernet TCP/IP or through the SNP port.
Configurable data and program memory
Battery-backed calendar clock
Three position operation mode switch
Password controlled access
Remote programmer keyswitch memory protection
Four status LEDs
Software configuration (No DIP switches or jumpers)
Reference information inside front door
In-system upgradable firmware
Features
Complete Analog subsystem includes Base Converter and Expander modules
Base Converter module has eight differential inputs individually configurable for voltage or current
Accepts unipolar or bipolar Analog Inputs up to " 10 volts full scale
Accepts 4 to 20 milliamp current loop signals
Individual user scaling on each input channel on Base Converter module; scaling on a per module basis for Expander modules
Fast update rate for Base Converter module
Voltage and current Expander modules, each with 16 inputs, provides for additional inputs at a lower cost per point
Complete subsystem can accept up to 120 inputs
No jumpers or DIP switches to configure
Easy configuration with MS-DOS
or Windows
programming software configuration function.