Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS200TCATH1A Core Analog Terminal Board
    ❤ Add to collection
  • GE IS200TCATH1A Core Analog Terminal Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS200TCATH1A Core Analog Terminal Board

    • ¥23650.00
      ¥24520.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:4.300KG
    • Quantity:
    • (Inventory: 33)
Description

GE IS200TCATH1A Core Analog Terminal Board


GE IS200TCATH1A Core Analog Terminal Board

Part Number IS200TCATH1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VIe Function Module Availability In StockIS200TCATH1A is a core analog terminal board developed by GE. It is a part of Mark VIe control system. The Core Analog terminal board serves as an augmentation to the I/O terminal capacity of the PCAA module. It takes on the responsibility of managing input signals, which are then distributed to either a single PCAA module or three of them. This encompassing functionality involves handling various input types, such as twelve seismic inputs, twelve LVDT inputs, twenty-four 4-20 mA inputs, and two magnetic pulse rate inputs. 

Ensuring the efficiency of the system, a distinct 24 V dc power source is allocated for all twenty-four 4-20 mA inputs. This power allocation is shared between the TCAT and an adjacent JGPA board, with half of the inputs being managed by each. This strategic power distribution optimizes the utilization of resources. Features TCAT generates three 4-20 mA voted signals, contributing to the precision of the system's output functionality. To facilitate these connections, the TCAT features a comprehensive array of field wire terminal points, with 120 pluggable Euro-style box terminals ensuring secure connections. Terminal points are organized into three groupings: one set of 48 terminals, another set of 24, and a final set of 48, enhancing the organization and accessibility of the system. 

Integrated JGPA, situated adjacently to the terminals, supplements the system's capabilities. It provides an additional twelve 24 V dc outputs tailored for 4-20 mA devices, as well as dedicated terminals for shielding wires. The power supply to the JGPA emanates from TCAT connectors P3 or P4, employing a diode-or arrangement that combines power from the connected PCAA modules. This setup ensures reliable power distribution and stability within the system. The terminal board's multifaceted role in the system includes enhancing I/O terminal capacity, managing diverse input signals, and providing a streamlined mechanism for generating output signals. This strategic allocation of power, comprehensive field wire terminal points, and collaboration with the adjacent JGPA board all contribute to the overall efficiency, reliability, and precision of the system's analog functionalities. 

 Characteristics Twelve seismic, twelve LVDT, twenty four 4-20 mA, and two magnetic pulse rate inputs are available. Each of the twenty-four 4-20 mA inputs has its own 24 V dc power source, with half on TCAT and the other half on an adjacent JGPA board. TCAT outputs are made up of three voted signals ranging from 4 to 20 mA. 120 pluggable Euro-style box terminals provide field wire terminal points. Terminal grouping consists of 48 terminals, 24 terminals, and 48 terminals again. A JGPA board next to the TCAT field terminals adds twelve more 24 V dc outputs for 4-20 mA devices and shield wire terminals. Connector P3 or P4 supplies power to JGPA and acts as a diode-or for power from connected PCAA modules. 

Terminal board is connected to one or more PCAA modules via pairs of 68-pin cables. PR1 and PR2 are routed to a PCAA that is linked to the R IONet. PS1 and PS2 are connected to a PCAA via the S IONet. PT1 and PT2 connect to a PCAA that is linked to T IONet. On each cable connection, it generates an electronic ID. Cables are always used in pairs, and the electronic ID is used by PCAA to ensure that the correct TCAT cables are in place. Installation The module is attached to a metal back base via an underlying insulating plastic carrier. Screws are located at the top and bottom of the field terminals, with a third screw in the board's center. It is attached to a metal back base via an underlying insulating plastic carrier. Screws are located at the top and bottom of the field terminals, with a third screw in the board's center. Wiring The TCAT terminal board has 120 Euro-style box terminals that can be plugged in. A JGPA board, which mounts next to the TCAT terminal board, provides 48 shield termination points as well as twelve 24 V dc output terminals for 4-20 mA transmitters. Operation The module distributes input signals to one or more PCAA modules. 

To ensure reliability in redundant applications, high reliability passive circuits are used. Board accepts 28 V dc power from PCAA modules that are connected. The power sources are then diode-ored to obtain redundant power input for the 24 V dc outputs. TCAT's 24 V outputs each have their own voltage regulator with thermal shutdown for branch circuit protection. Product Attributes Input: Twenty-four signals in the range of 4-20 mA. A total of twelve seismic signals. Twelve LVDT windings are incorporated as inputs. Additionally, two magnetic pulse rate flow signals are accepted. Output: Three analog outputs with hardware voting, operating in the 4-20 mA range. A set of twelve outputs, each capable of 24 V dc, with the capacity to handle 25 mA current. An auxiliary set of twelve 24 V dc outputs on the JGPA, also with a 25 mA capacity. 

 Power Supply Voltage: A power supply voltage of 28 V dc, with a tolerance of 脗卤5%, is sourced from either one or more PCAA modules. Another power supply source is 脗卤15 V dc, also derived from one or more PCAA modules. Both of these power supply inputs are routed through the cabling linking the PCAA and TCAT components. Pulse Rate Input: For proper measurement, the minimum signal strength required is 33 mVpk at a frequency of 2 Hz. Similarly, the minimum signal strength required for accurate measurement at a frequency of 12 kHz is 827 mVpk.

SPECIFICATIONS

Part Number: IS200TCATH1A
Manufacturer: General Electric
Series: Mark VIe
Size: 33.02 cm high x 17.8 cm wide
Technology: Surface-mount
Temperature Operating: -30oC to 65oC
Product type: Core Analog Terminal Board
Country of Manufacture: United States (USA)


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Alcatel Lucent 1660SM Optical Transmission System Architecture and Business Bearer
  • ALCATEL-LUCENT 9500 MPR Microwave Packet Wireless System Performance
  • Atlas Copco MT Focus 6000 Controller Safety Specification and Electrical Grounding
  • Atlas Copco Power MACS 4000 Automated Tightening System Performance
  • Design and Protection of Constant Torque Application for Atlas Copco Neos Inverter
  • Atlas Copco Power Focus 8 Family Selection Configuration and Virtual Station Function Complete Explanation
  • Atlas Copco Power Focus 4000 Controller Safety Deployment and Electrical Grounding Specification
  • Atlas Copco Power Focus 3000 Controller Installation, Debugging, and Troubleshooting Guide
  • Atlas Copco Tensor S Tightening Tool Troubleshooting Guide
  • Application and maintenance of Atlas Copco SRTT-B torque sensor
  • Atlas Copco ACTA 4000 Torque Analyzer Operation and Calibration Guide
  • Atlas Copco Tensor STB Wireless Tightening Tool Deployment Guide
  • Atlas Copco Power Focus 4000 Configuration and Troubleshooting Manual
  • Atlas Copco Power Focus 6000 and Tensor STR System
  • Energy efficiency and selection of Atlas Copco ZR/ZT oil-free screw compressor
  • Atlas Copco PowerMACS 4000 Tightening Control System
  • Atlas Copco Elektronikon MK5 Controller Operation Guide
  • Atlas Copco Tensor ES and PF600 Tightening System
  • ADLINK STC2-AL/KL Industrial Control Tablet BIOS and Drivers
  • ADLINK STC-15W04 industrial tablet computer
  • ADLINK SP2-EHL Fanless Tablet Selection and Configuration Guide
  • ADLINK PXIS-2719A Chassis Deployment Monitoring Guide
  • ADLINK PXIe-9908 SMU Deployment and Configuration Guide
  • ADLINK PXIe-9852 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9848 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9834 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9529H Dynamic Signal Acquisition Configuration Guide
  • ADLINK PXIe-3988 Xeon Deployment Optimization Guide
  • ADLINK PXIe-3987/3977/3937 Deployment and Debugging
  • ADLINK PXIe-3987 Installation and Configuration Programming Guide
  • ADLINK-PXIe-3988-3987-3977-3937-TL Controller Deployment and Maintenance Guide
  • ADLINK PXI-2020/2022 Synchronous Acquisition Card Configuration and Synchronization Guide
  • ADLINK DAQ/PXI-2000 series synchronous acquisition card configuration and triggering
  • ADLINK PXES-2788 series chassis deployment and maintenance
  • ADLINK PXES-2785 18 Slot Gen3 Chassis Deployment and Maintenance Guide
  • ADLINK PXES-2780 18 Slot PXIe Chassis Deployment Configuration
  • ADLINK PXES-2596 Gen3 Chassis Installation and Maintenance Guide
  • ADLINK PXES-2590 Chassis Deployment and System Management
  • ADLINK PXES-2314T Chassis Deployment and Troubleshooting Guide
  • ADLINK PXES-2301 Chassis Installation Monitoring and Troubleshooting
  • ADLINK PCIe-U300 Series USB3 Vision Acquisition Card Deployment Guide
  • ADLINK PCIe PXIe-8565 Expansion Kit Remote Control and Compatibility
  • Installation and troubleshooting of ADLINK PCIe GIE74V four channel PoE acquisition card
  • ADLINK PCIe GIE7x Poe+Acquisition Card Configuration and Triggering Troubleshooting
  • Advanced triggering and multi card synchronization of ADLINK PCIe-CPL64V image acquisition card
  • ADLINK PCIe-CPL64 Image Acquisition Card Hardware Trigger and Encoder Application
  • Application and troubleshooting of ADLINK PCIe-8560/PXI-8565 expansion kit
  • ADLINK PCIe 8332/PCIe 8334/PCIe 8338 EtherCAT Motion Controller Multi axis Synchronous Control
  • ADLINK PCIe-7432 32 channel isolated I/O card interrupt and driver
  • ADLINK PCIe-7256 Industrial I/O Card Interruption and Relay
  • ADLINK PCIe-833x EtherCAT Motion Controller Debugging and Maintenance
  • ADLINK PCIe-10GPoE 10GigE Visual Acquisition Card Practical Use
  • ADLINK PCI-8254/8258 Motion Controller Debugging and Maintenance
  • Application and Maintenance of ADLINK PCI-8158 Multi axis Motion Control Card
  • ADLINK PCI-8134A Maintenance and Troubleshooting Guide
  • ADLINK PCI-7250 Series Relay Output Card Configuration and Protection Circuit Guide
  • ADLINK PCI-6308 Series Isolated Analog Output Card Configuration and Programming
  • ADLINK PanKonix Series HMI Panel Selection and Deployment Guide
  • ADLINK NuDAM-6100 Series I/O Module Deployment and Protocol Optimization
  • Deployment and Calibration of ADLINK NuDAM-6000 Data Acquisition Module
  • ADLINK NEON-2000-Ono Intelligent Camera Deployment and Trigger Optimization
  • ADLINK NuDAM-65xx Communication Module Networking and Configuration Guide
  • ADLINK NuDAM-60xx Series Digital I/O Module Deployment and Watchdog Optimization
  • ADLINK MXE-5300 Fanless Industrial Control Computer Deployment and Troubleshooting Manual
  • ADLINK MXE-310 edge computing Platform Hardware Installation and BIOS Tuning
  • ADLINK MXE-230 series Alder Lake platform industrial computer deployment and maintenance manual
  • ADLINK MXE-210 Compact Fanless Industrial Control Computer Hardware Deployment and Debugging Guide
  • ADLINK MXC-3300/3340 Embedded Industrial Control Computer Hardware Integration and Debugging Manual
  • ADLINK MXA-312M Edge AI Platform Hardware Integration and Debugging Guide
  • ADLINK MXA-200 IoT Gateway Hardware Installation and Linux System Debugging Complete Guide
  • ADLINK MVP-6200 Industrial Control Computer: PCIe Gen4 and PCI Hybrid Expansion
  • ADLINK MVP-6100 Industrial Control Computer: PCI/PCIe Expansion and Robust Design
  • ADLINK MVP-5200 Industrial Control Computer: High Performance Multi Display and TSN Network
  • ADLINK MVP-5100 Fanless Industrial Control Computer Deployment and Development Guide
  • ADLINK MVP-3100 and MVP-3120 Embedded Systems
  • ADLINK MNET-J3/S23/MIA/DA2/SAN Single Axis Module Installation and Wiring Guide
  • ADLINK MNET-4XMO/C Motion Module Installation and Debugging Guide
  • ADLINK MCM-216/218 Edge DAQ Deployment Configuration Guide
  • ADLINK LPCIe-8124-C Encoder Card Trigger Configuration Guide
  • ADLINK IM/OM Series Industrial Display Installation and Debugging Guide
  • ADLINK GW-01 Industrial IoT Gateway Configuration and Debugging Guide
  • EURESYS Grablink Collection Card Selection and Trigger Configuration Guide
  • ADLINK Express HL Module Selection and Heat Dissipation Configuration Guide
  • ADLINK EOS-2000 Visual System Installation and Troubleshooting
  • ADLINK EOS-1200 Installation, Configuration, and Troubleshooting
  • Application and Configuration of ADLINK ECS-8582-4S Extension System
  • ADLINK DIN-814P-A4 Panasonic servo adapter board configuration
  • ADLINK DIN-814M-J3A Mitsubishi servo adapter board configuration
  • ADLINK DIN-814-GP Universal Adapter Board Configuration
  • Application and Configuration of ADLINK DIN-812M Adapter Board
  • Application and Configuration of ADLINK DIN-814Y Adapter Board
  • ADLINK DAQ/DAQE/PXI-250x waveform generation complete guide
  • ADLINK DAQ/DAQE/PXI-220x acquisition card fully configured
  • Application and Configuration of ADLINK cPCI-9116 Data Acquisition Card
  • ADLINK cPCI/PCI-8554/R: A Complete Guide from Architecture to Application
  • ADLINK cPCI-7432/7433/7434 isolated I/O card
  • ADLINK cPCI-3544/3534/3538 Serial Cardcard Configuration Practice
  • ADLINK cPCI-3534/3538/3544 Multi Serial Port Card Configuration Complete Solution
  • Complete Technical Guide for Euresys Coaxlink CXP Capture Card
  • ADLINK AMP-304C Advanced Motion Control Card Complete Guide
  • ADLINK AMP-104C Four Axis Motion Control Card
  • ADLINK NEON-1020/1040 Smart Camera
  • ADLINK USB-7230/7250 Isolation I/O Module Operation Manual
  • ADLINK SP-15W03 Intelligent Panel Integration and Configuration Manual
  • ADLINK AMP-20xC Interface Configuration and Wiring Guide
  • ADLINK 3488A GPIB Interface Card Selection Guide
  • Complete solution of ETEL TMB+torque motor selection parameters
  • ADLINK RTV series frame grabber deployment guide
  • ADLINK PCIe-FIW64/62 Image Acquisition Card Configuration Guide
  • ADLINK 6208/6216-GL Analog Output Card
  • ADLINK 723X Isolation I/O Card Configuration Guide
  • ADLINK PCI-9118 series high-speed DAQ card selection and DMA configuration
  • ADLINK PCI-9114 (A) Data Acquisition Card Selection and Configuration Guide
  • ADLINK PCI-7442/7443/7444 Isolation I/O Card Selection and Safety Configuration
  • ADLINK PCI-7250/7251 Relay Output Card Selection and Expansion Guide
  • Selection and Protection Configuration of Advantech PCI-1610CU Multi Serial Port Card
  • ADLINK NEON-1000-MDX Smart Camera Deployment and Trigger Configuration
  • ADLINK MXE-1300 Industrial Control Computer Selection and Deployment Guide
  • ADLINK MXE-200 Industrial Control Computer Deployment and BIOS Optimization Guide
  • ADLINK LPCIe-3488A GPIB Card Installation and Configuration Guide
  • Guidelines for Key Technologies of ETEL LMG/LMS Linear Motor Integration
  • ETEL IL+/LM Linear Motor Selection and Integration Guide
  • ETEL DSCDP/DSCDL/DSCDM Dual Axis Controller Debugging Guide
  • ETEL DSCDL Dual Axis Controller Hardware Integration Guide
  • ETEL DSB2P Series Servo Amplifier Connection and Configuration Guide
  • ETEL DSC2P/DSC2V Servo Controller Debugging Guide
  • DFI HD636-H81CS Industrial Motherboard Deployment and Debugging
  • Integration and Optimization of ADLINK DAQ-20xx Synchronous Acquisition Card