Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS200TCATH1A Core Analog Terminal Board
    ❤ Add to collection
  • GE IS200TCATH1A Core Analog Terminal Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS200TCATH1A Core Analog Terminal Board

    • ¥23650.00
      ¥24520.00
      ¥23650.00
      ¥23650.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:4.300KG
    • Quantity:
    • (Inventory: 33)
Description

GE IS200TCATH1A Core Analog Terminal Board


GE IS200TCATH1A Core Analog Terminal Board

Part Number IS200TCATH1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VIe Function Module Availability In StockIS200TCATH1A is a core analog terminal board developed by GE. It is a part of Mark VIe control system. The Core Analog terminal board serves as an augmentation to the I/O terminal capacity of the PCAA module. It takes on the responsibility of managing input signals, which are then distributed to either a single PCAA module or three of them. This encompassing functionality involves handling various input types, such as twelve seismic inputs, twelve LVDT inputs, twenty-four 4-20 mA inputs, and two magnetic pulse rate inputs. 

Ensuring the efficiency of the system, a distinct 24 V dc power source is allocated for all twenty-four 4-20 mA inputs. This power allocation is shared between the TCAT and an adjacent JGPA board, with half of the inputs being managed by each. This strategic power distribution optimizes the utilization of resources. Features TCAT generates three 4-20 mA voted signals, contributing to the precision of the system's output functionality. To facilitate these connections, the TCAT features a comprehensive array of field wire terminal points, with 120 pluggable Euro-style box terminals ensuring secure connections. Terminal points are organized into three groupings: one set of 48 terminals, another set of 24, and a final set of 48, enhancing the organization and accessibility of the system. 

Integrated JGPA, situated adjacently to the terminals, supplements the system's capabilities. It provides an additional twelve 24 V dc outputs tailored for 4-20 mA devices, as well as dedicated terminals for shielding wires. The power supply to the JGPA emanates from TCAT connectors P3 or P4, employing a diode-or arrangement that combines power from the connected PCAA modules. This setup ensures reliable power distribution and stability within the system. The terminal board's multifaceted role in the system includes enhancing I/O terminal capacity, managing diverse input signals, and providing a streamlined mechanism for generating output signals. This strategic allocation of power, comprehensive field wire terminal points, and collaboration with the adjacent JGPA board all contribute to the overall efficiency, reliability, and precision of the system's analog functionalities. 

 Characteristics Twelve seismic, twelve LVDT, twenty four 4-20 mA, and two magnetic pulse rate inputs are available. Each of the twenty-four 4-20 mA inputs has its own 24 V dc power source, with half on TCAT and the other half on an adjacent JGPA board. TCAT outputs are made up of three voted signals ranging from 4 to 20 mA. 120 pluggable Euro-style box terminals provide field wire terminal points. Terminal grouping consists of 48 terminals, 24 terminals, and 48 terminals again. A JGPA board next to the TCAT field terminals adds twelve more 24 V dc outputs for 4-20 mA devices and shield wire terminals. Connector P3 or P4 supplies power to JGPA and acts as a diode-or for power from connected PCAA modules. 

Terminal board is connected to one or more PCAA modules via pairs of 68-pin cables. PR1 and PR2 are routed to a PCAA that is linked to the R IONet. PS1 and PS2 are connected to a PCAA via the S IONet. PT1 and PT2 connect to a PCAA that is linked to T IONet. On each cable connection, it generates an electronic ID. Cables are always used in pairs, and the electronic ID is used by PCAA to ensure that the correct TCAT cables are in place. Installation The module is attached to a metal back base via an underlying insulating plastic carrier. Screws are located at the top and bottom of the field terminals, with a third screw in the board's center. It is attached to a metal back base via an underlying insulating plastic carrier. Screws are located at the top and bottom of the field terminals, with a third screw in the board's center. Wiring The TCAT terminal board has 120 Euro-style box terminals that can be plugged in. A JGPA board, which mounts next to the TCAT terminal board, provides 48 shield termination points as well as twelve 24 V dc output terminals for 4-20 mA transmitters. Operation The module distributes input signals to one or more PCAA modules. 

To ensure reliability in redundant applications, high reliability passive circuits are used. Board accepts 28 V dc power from PCAA modules that are connected. The power sources are then diode-ored to obtain redundant power input for the 24 V dc outputs. TCAT's 24 V outputs each have their own voltage regulator with thermal shutdown for branch circuit protection. Product Attributes Input: Twenty-four signals in the range of 4-20 mA. A total of twelve seismic signals. Twelve LVDT windings are incorporated as inputs. Additionally, two magnetic pulse rate flow signals are accepted. Output: Three analog outputs with hardware voting, operating in the 4-20 mA range. A set of twelve outputs, each capable of 24 V dc, with the capacity to handle 25 mA current. An auxiliary set of twelve 24 V dc outputs on the JGPA, also with a 25 mA capacity. 

 Power Supply Voltage: A power supply voltage of 28 V dc, with a tolerance of 脗卤5%, is sourced from either one or more PCAA modules. Another power supply source is 脗卤15 V dc, also derived from one or more PCAA modules. Both of these power supply inputs are routed through the cabling linking the PCAA and TCAT components. Pulse Rate Input: For proper measurement, the minimum signal strength required is 33 mVpk at a frequency of 2 Hz. Similarly, the minimum signal strength required for accurate measurement at a frequency of 12 kHz is 827 mVpk.

SPECIFICATIONS

Part Number: IS200TCATH1A
Manufacturer: General Electric
Series: Mark VIe
Size: 33.02 cm high x 17.8 cm wide
Technology: Surface-mount
Temperature Operating: -30oC to 65oC
Product type: Core Analog Terminal Board
Country of Manufacture: United States (USA)


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • OMRON CK3W-AX Multi axis Control Selection
  • Debugging and maintenance of EPSON RC90/RC90-B controller
  • Nthytronic Group iRTUe I/O Expansion Module
  • Schneider ATV320 Inverter Installation and Debugging Guide
  • Eaton SPB Drawdown Switch Maintenance Guide
  • GFS EVO-SP dual fuel retrofit complete solution
  • OMRON CJ2 CPU Troubleshooting and Maintenance
  • Complete Guide to Lenze ECS Servo System
  • GE EX2100e Excitation System Complete Guide
  • OMRON G3PW Power Controller: Parameter Setting and Troubleshooting Guide
  • Key Points for Selection and Deployment of MITSUBISHI FX3GE PLC
  • Beckhoff EP23xx EtherCAT Box Selection Troubleshooting
  • MITSUBISHI MDS-B servo troubleshooting
  • TOYO valve pressure and temperature selection
  • SIEMENS SIMODRIVE 611 HR/HRS Replacement and Advanced Positioning Techniques
  • SIEMENS SINUMERIK 840C 611-D Startup and Troubleshooting Guide
  • FANUC Series 0i-F Maintenance and Troubleshooting
  • Troubleshooting Schneider Modicon TM3 Bus Expansion
  • Troubleshooting of R&S EPL1000
  • Baum ü llerb b maXX 5000 Safety Configuration and Troubleshooting Guide
  • Huichuan AM600 Motion Controller Malfunction and Replacement Guide
  • Allen Bradley Ultra3000 Servo Motor Replacement Guide
  • NEC NL8060BC26-17 LCD Module Maintenance and Replacement
  • ABB Pluto Safety PLC Maintenance and Troubleshooting
  • OMRON NE1A Safety Controller Troubleshooting and Replacement
  • Allen Bradley 2711P series PanelView Plus human-machine interface terminal
  • NI cFP-22xx on-site integration and troubleshooting
  • KEYENCE XG-8000 Line Scan Visual Debugging Guide
  • OMRON G9SX Security Unit Configuration and Troubleshooting
  • OMRON CPM1A Maintenance and Troubleshooting
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide