Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS200TRTDH1B RTD Input terminal board
    ❤ Add to collection
  • GE IS200TRTDH1B RTD Input terminal board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS200TRTDH1B RTD Input terminal board

    • ¥33620.00
      ¥33625.00
      ¥33620.00
      ¥33620.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.900KG
    • Quantity:
    • (Inventory: 31)
Description

GE IS200TRTDH1B RTD Input terminal board


GE IS200TRTDH1B RTD Input terminal board

Part Number IS200TRTDH1B Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI Function Module Availability In StockIS200TRTDH1B is an RTD Terminal Card developed by General Electric. The TRTD terminal board supports 16 three-wire RTD inputs. These inputs are connected to two barrier terminal blocks. Surge and high frequency noise are protected by noise suppression circuitry in the inputs. TRTD communicates with one or more I/O processors, which convert input temperature values to digital temperature values and send them to the controller. TRTDH1B is a TMR version that uses six DC-type connectors to fan out signals to three VRTD boards. 

 IS200TRTDH1B Installation Connect the wires for the 16 RTDs to the terminal board's two terminal blocks. Each block is held together with two screws and has 24 terminals that accept wires up to #12 AWG. To the left of each terminal block is a shield terminal strip connected to chassis ground. It is necessary to use double-shielded wire. The shield terminal strip must be used to terminate all shields. End shields that are located at the end device. H1B provides redundant RTD inputs in a TMR Mark VI control system by fanning the inputs to three VRTD boards in the R, S, and T racks. The inputs meet the same environmental, resolution, suppression, and function requirements, as well as the same codes as the H1C terminal board. Operation TRTD provides a 10 mA dc multiplexed (not continuous) excitation current to each grounded or ungrounded RTD. 

With a maximum two-way cable resistance of 15, the 16 RTDs can be located up to 300 m (984 ft) from the turbine control cabinet. The I/O processor's A/D converter samples each signal and excitation current four times per second in normal mode scanning and 25 times per second in fast mode scanning, with a time sample interval related to the power system frequency. The linearization for the 15 RTD types is done by software. Out-of-range values detect RTD open and short circuits. To avoid adverse effects on other input channels, an RTD that is determined to be outside the hardware limits is removed from the scanned inputs. Repaired channels are automatically or manually reinstated in 20 seconds. 

At signal entry, all RTD signals have high-frequency decoupling to ground. The I/O processor's RTD multiplexing is coordinated by redundant pacemakers, so that the loss of a single cable or I/O processor does not result in the loss of any RTD signals in the control database. Characteristics Eight channels per terminal board Span 0.3532 to 4.054 V Maximum lead resistance 15 ohm maximum two-way cable resistance Fault detection - High/low (hardware) limit check, High/low (software) system limit check, Failed ID chip IS200TRTDH1B Diagnostics Each RTD type has hardware limit checking based on predefined (non-configurable) high and low levels set near the operating range's extremes. When this limit is reached, a logic signal is generated and the input is no longer scanned. If any of the input's hardware limits is exceeded, a composite diagnostic alarm, L3DIAG xxxx, referring to the entire board is generated. 

The toolbox contains information on the individual diagnostics. Individual diagnostic signals can be latched and then reset with the RESET DIA signal. System limit checking is performed on each RTD input based on configurable high and low levels. These limits can be configured for enable/disable as well as latching/non-latching to generate alarms. RESET SYS clears all out-of-limit signals. Limit logic signals are voted in TMR systems, and the resulting composite diagnostic is present in each controller. Each RTD's resistance is checked and compared to the correct value; if it is too high or too low, a fault is generated. Each connector has its own ID device, which the I/O processor board interrogates. A read-only chip containing the terminal board serial number, board type, revision number, and connector location is coded with the terminal board ID. 

When a mismatch occurs, a hardware incompatibility fault is generated. Features JTA/JTB, JSA/JSB, and JRA/JRB are the cable connector labels. When repair is required, the terminal blocks are designed to unplug from the board. Each terminal block has twenty-four screw connections and may receive up to eight three-wire RTD inputs. A shield bar has been placed directly to the left of these components. The PCB's six connectors are used to fan signal out to three VRTD boards. It is compatible with both simplex and TMR applications. It is vital to remember that the board does not support quick scanning. 

Each RTD connected has the option of being grounded or ungrounded. Each of these components, which can be located up to 300 meters away from the turbine control cabinet, receives a 10 mA dc multiplexed excitation from the board. At 400 degrees Fahrenheit, RTD accuracy ranges from 2 degrees Fahrenheit to 10 degrees Fahrenheit. There are no jumper switches or hardware settings. The board has both hardware and software system limit checking. If the read-only chip on the board is not compatible, a hardware incompatibility fault will be generated.

Our Main Brands

· - ABB Advant-800xAAdvant OCSBailey Infi 90 and Net 90H&B Freelance 2000DSQC RobotsIGCT / IGBT

· - GE General Electric Field Control, Genius I/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax

· - Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,

· - Bently Nevada 3300 System, 3500 System

· - Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)

· - Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC

· - Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • OMRON CK3W-AX Multi axis Control Selection
  • Debugging and maintenance of EPSON RC90/RC90-B controller
  • Nthytronic Group iRTUe I/O Expansion Module
  • Schneider ATV320 Inverter Installation and Debugging Guide
  • Eaton SPB Drawdown Switch Maintenance Guide
  • GFS EVO-SP dual fuel retrofit complete solution
  • OMRON CJ2 CPU Troubleshooting and Maintenance
  • Complete Guide to Lenze ECS Servo System
  • GE EX2100e Excitation System Complete Guide
  • OMRON G3PW Power Controller: Parameter Setting and Troubleshooting Guide
  • Key Points for Selection and Deployment of MITSUBISHI FX3GE PLC
  • Beckhoff EP23xx EtherCAT Box Selection Troubleshooting
  • MITSUBISHI MDS-B servo troubleshooting
  • TOYO valve pressure and temperature selection
  • SIEMENS SIMODRIVE 611 HR/HRS Replacement and Advanced Positioning Techniques
  • SIEMENS SINUMERIK 840C 611-D Startup and Troubleshooting Guide
  • FANUC Series 0i-F Maintenance and Troubleshooting
  • Troubleshooting Schneider Modicon TM3 Bus Expansion
  • Troubleshooting of R&S EPL1000
  • Baum ü llerb b maXX 5000 Safety Configuration and Troubleshooting Guide
  • Huichuan AM600 Motion Controller Malfunction and Replacement Guide
  • Allen Bradley Ultra3000 Servo Motor Replacement Guide
  • NEC NL8060BC26-17 LCD Module Maintenance and Replacement
  • ABB Pluto Safety PLC Maintenance and Troubleshooting
  • OMRON NE1A Safety Controller Troubleshooting and Replacement
  • Allen Bradley 2711P series PanelView Plus human-machine interface terminal
  • NI cFP-22xx on-site integration and troubleshooting
  • KEYENCE XG-8000 Line Scan Visual Debugging Guide
  • OMRON G9SX Security Unit Configuration and Troubleshooting
  • OMRON CPM1A Maintenance and Troubleshooting
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide