Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS200VTURG1B Turbine Specific Primary Trip Board
    ❤ Add to collection
  • GE IS200VTURG1B Turbine Specific Primary Trip Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS200VTURG1B Turbine Specific Primary Trip Board

    • ¥18445.46
      ¥19554.26
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:1.500KG
    • Quantity:
    • (Inventory: 45)
Description

GE IS200VTURG1B Turbine Specific Primary Trip Board


GE IS200VTURG1B Turbine Specific Primary Trip Board

Part Number IS200VTURG1B Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS200VTURG1B is a turbine specific primary trip board developed by GE. It is a part of Mark VI control system. It employs four passive pulse rate devices to accurately measure the speed of the turbine. These measurements are transmitted to the controller, which utilizes this data to generate the primary overspeed trip signal. 

This overspeed trip mechanism acts as a crucial safety feature, ensuring that the turbine does not exceed safe operational speeds, thereby preventing potential damage or catastrophic failure. FEATURES Generator Synchronization and Breaker Closure: Additionally, it facilitates the automatic synchronization of the generator.Once synchronization is achieved, it coordinates the closure of the main breaker, allowing the generated power to be efficiently transmitted through the electrical system. Monitoring Shaft Voltage and Current: Equipped to monitor the induced voltage and current on the turbine shaft. This monitoring capability is vital for detecting any irregularities or abnormalities in the turbine's operation, enabling timely intervention to prevent damage or malfunction. Flame Detection: In gas turbine applications, oversees the operation of eight Geiger Mueller flame detectors. 

These detectors, connected to the TRPG, are supplied with 335 V DC and 0.5 mA from an external source. The function of these detectors is to detect the presence or absence of flames within the turbine, providing critical information for maintaining safe combustion processes. Overspeed Trip Control: Controlling the primary overspeed trip relays on the TRPG terminal board. It generates the trip signal based on the turbine speed measurements and other relevant parameters. This trip signal is then transmitted to the TRPG, initiating the activation of emergency solenoids to trigger the turbine overspeed trip. 

Notably, it can receive overspeed trip signals from both itself and VPRO, providing redundancy and enhancing system reliability. Interface with Electrical Trip Devices (ETD): Within the TRPG, nine magnetic relays interface with three trip solenoids, collectively known as Electrical Trip Devices (ETD). These relays, nine in total for Triple Modular Redundancy (TMR) systems and three for simplex systems, serve to ensure the reliable operation of the trip mechanisms. By coordinating with VTUR and other components, the ETDs play a crucial role in swiftly and effectively executing turbine shutdown procedures in response to critical events like overspeed conditions. 

INSTALLATION Power Down the VME Processor Rack:Prior to installation, it's crucial to power down the VME processor rack to prevent any electrical interference or potential damage to the components. This step involves safely shutting down any associated systems and disconnecting power sources to the VME rack to ensure a secure installation environment. Slide in the Board: With the VME processor rack powered down, the next step is to carefully slide the board into the designated slot within the rack. Precision is key during this process to align the board correctly with the slot and ensure a proper fit. Once the board is positioned correctly, apply gentle pressure to push the top and bottom levers in with your hands. 

This action secures the edge connectors of the board firmly in place within the slot, establishing electrical connectivity with the rack and other components. Secure with Captive Screws:After seating the board in the slot, the final step is to secure it in position by tightening the captive screws located at the top and bottom of the front panel.Captive screws are designed to remain attached to the panel even when loosened, simplifying the installation process and reducing the risk of misplaced hardware. Tightening these screws ensures that the board remains securely fastened within the rack, minimizing the potential for displacement or instability during operation. 

 FAST OVERSPEED TRIP PR_Single: This algorithm utilizes redundant VTUR packs, distributing the workload across two separate boards. Each redundant PR (Pulse Rate) transducer is assigned to one board, ensuring redundancy and enhancing reliability. PR_Single is the preferred algorithm for LM (Land and Marine) gas turbines, offering a robust overspeed protection mechanism tailored to the specific requirements of these turbines. PR_Max: In contrast to PR_Single, PR_Max utilizes a single VTUR pack connected to two redundant PR transducers. This configuration allows for broken shaft detection and deceleration protection while mitigating the risk of nuisance trips in the event of transducer failure. PR_Max offers a balanced approach, combining effective overspeed protection with enhanced fault tolerance, thereby ensuring the uninterrupted operation of the turbine under diverse operating conditions.

SPECIFICATIONS

Part No.: IS200VTURG1B
Manufacturer: General Electric
Country of Manufacture: United States of America (USA)
MPU pulse rate range 2 Hz to 20 kHz
MPU pulse rate accuracy 0.05 percent
MPU input circuit sensitivity 27 mV pk
Flame detectors: 8 per VTUR
Temperature rating: 0 to 60 oC
Product Type: turbine specific primary trip board
Availability: In Stock
Series: Mark VI


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Rexroth Indramat BTV20.3 Operation Terminal Installation and Maintenance Guide
  • Bosch Rexroth Indramat PPC-R02 Controller Replacement Guide
  • Phoenix Contact Inline I/O System Selection Guide
  • Rexroth VCP 08 Operating Terminal Selection and Installation Guide
  • Rexroth IndraDyn H Spindle Motor Planning Guide
  • Detailed explanation of ElectroLogIXS VLC interlocking signal controller
  • Yokogawa AIP830 Single Circuit Operation Keyboard
  • Yokogawa RAMC flowmeter selection and troubleshooting
  • YASKAWA GA500 frequency converter troubleshooting
  • TRACO TIS600 power supply
  • Sigmatek ETV-0851 Control Panel Troubleshooting
  • Allen Bradley Quest AN-X2-AB-DHRIO Remote I/O Adapter Integration and Troubleshooting
  • Meggitt RPS6U power supply
  • Kongsberg RCU500 Controller Integration and Fault Diagnosis Guide
  • KBAC series frequency converter installation and fault diagnosis guide
  • EXOR effectiveness View eV058 series HMI industrial panel
  • Emerson OCR3000 Controller Troubleshooting Guide
  • Emerson Ovation OCR1100 Controller Maintenance and Troubleshooting
  • Elmo G-TUB30 Driver Troubleshooting Guide
  • Troubleshooting and Optimization of Basler A400 Series Camera
  • Troubleshooting and Maintenance of Automated Logic I/O Expansion Module
  • Troubleshooting and Maintenance of Aerotech UNIDEX 100 Controller
  • ADVANEST R6144 calibration source troubleshooting
  • Troubleshooting and Calibration of ABB Millmate Tension Gauge
  • ABB NGC8206 natural gas chromatograph troubleshooting and maintenance
  • ABB AO2040-CU Ex Explosion proof Analyzer Troubleshooting
  • ABB PFEA113 Tension Controller Troubleshooting Guide
  • ABB PFEA111/112/122 Tension Controller Troubleshooting Guide
  • ABB LS4000 laser analyzer
  • ABB SPAU 341 C Voltage Regulator Troubleshooting Guide
  • Analysis and Fault Diagnosis of ABB V-Contact VSC Medium Voltage Contactor
  • ABB UNITOL 1020 Compact Digital Excitation Regulator AVR Replacement and Troubleshooting
  • ABB UNITROL 1000 excitation system replacement and troubleshooting
  • ABB SYNC HROTACT 5 synchronization module troubleshooting and replacement
  • ABB SYNC HROTACT 5 Synchronization Device Replacement and Troubleshooting Guide
  • ABB Symphony Plus Module Replacement and Upgrade Guide
  • ABB S900 I/O Hazardous Area Deployment and Maintenance
  • ABB System 800xA Operations and Troubleshooting
  • ABB PCS6000 Troubleshooting and Module Replacement Guide
  • ABB PCS 8000 pumped storage excitation
  • ABB Procontrol P13 Bus Coupling Upgrade Guide
  • ABB NextMove ESB-2 Fault Diagnosis and Configuration Practice
  • ABB MEGADRIVE-LCI Maintenance and Selection Practice
  • ABB MEGADRIVE LCI Transmission Vibration Suppression
  • ABB MEGADRIVE LCI Water Cooling Troubleshooting and Maintenance Guide
  • Practical Maintenance and Common Troubleshooting of ABB DCS880
  • ABB SDCS-IOB-3 Replacement and Troubleshooting
  • ALSTOM MAE99-04 Serial Interface Terminal Panel Maintenance and Troubleshooting
  • Installation and Maintenance of ALSTOM ALSPA MV3000 Handheld Operator
  • Maintenance and commissioning of ABB KPM KB2 paper breakage detector
  • Maintenance and troubleshooting of ABB SCC-K converter
  • ABB SCC Gas Preprocessing System Maintenance and Selection Guide
  • ABB NGC8209 gas chromatograph maintenance
  • Maintenance and troubleshooting of ABB DCS DC speed controller
  • ABB ASTAT Crane Controller Maintenance and Debugging Guide
  • ABB ACS800 TIM foil IGBT
  • ABB LS25 laser analyzer troubleshooting
  • ABB REM54 motor terminal troubleshooting
  • ABB REL670 distance protection and troubleshooting
  • ABB SUE3000 switching device troubleshooting
  • ABB REF630 feeder protection
  • ABB REF620 (Relion 620 series) feeder protection and measurement device
  • ABB E1B-A Circuit Breaker
  • ABB FCU400-IR temperature measurement system troubleshooting
  • ABB TZIDC-200 locator configuration and troubleshooting
  • ABB DHH805-A Handheld Operator Configuration and Activation Guide
  • ABB SACO 16D1 alarm device replacement and troubleshooting
  • ABB 5SHY3545L0016 IGCT module replacement guide
  • ABB S600 I/O Module Replacement and Troubleshooting Guide
  • ABB NextMove e100 motion controller troubleshooting guide
  • Rockwell PowerFlex 700 Inverter Replacement and Troubleshooting Guide
  • Allen Bradley 1762-OW16 Output Module
  • Allen Bradley IntelliVAC 1503VC Series E Control Module
  • Allen‑Bradley IntelliVAC ™ 1503VC contactor control module
  • Woodward SOGAV 250 solenoid valve drives gas intake valve for troubleshooting
  • Woodward easyYgen-3500XT-P1 obstacle removal
  • Woodward CPC-II electro-hydraulic current pressure converter
  • UniOP ePALM10 Handheld HMI
  • TMEIC TMdrive-30 frequency converter
  • TEWS TVME200 Carrier Board Configuration and Troubleshooting Guide
  • TDK Alpha 400 Power Troubleshooting Guide
  • STUCKE SYMAP relay
  • Deployment and troubleshooting of Softing CAN-AC2-PCI interface card
  • Installation, Maintenance, and Troubleshooting of Siemens C7-623/624
  • Foxboro Compact 200 Series 16 Slot Bottom Plate Deployment and Maintenance Guide
  • Foxboro 84F/84W Vortex Flow Meter Selection and Debugging Guide
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller
  • DATA PATTERNS DP-VME-5114 Dual PMC Carrier Board Integration and Troubleshooting
  • CMZ SVM1608 Intelligent Servo Driver
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide
  • SUMITOMO ELECTRIC AC1135U Small Parts Turning Application Guide
  • SUMITOMO ELECTRIC AC1030U Precision Machining Selection and Practice for Small Parts
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection