  • GE IS2020SSRKG2 VME Rack Main Power Supply Module
    ❤ Add to collection
  • GE IS2020SSRKG2 VME Rack Main Power Supply Module

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS2020SSRKG2 VME Rack Main Power Supply Module

    • ¥14502.56
      ¥10452.16
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.460KG
    • Quantity:
    • (Inventory: 36)
Description

GE IS2020SSRKG2 VME Rack Main Power Supply Module


GE IS2020SSRKG2 VME Rack Main Power Supply Module

Part Number IS2020SSRKG2 Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS2020SSRKG2 is a VME Rack Main Power Supply developed by GE. It is a part of Mark VI control system. The SSRKG2 stands as a vital component within the Mark VI control system, serving as the VME Rack Main Power Supply developed by GE. 

Positioned on the right side of the VME control racks and interface, this power supply unit plays a crucial role in ensuring consistent and reliable power distribution within the system. PHYSICAL CONFIGURATION AND CONNECTIVITY Mounting Position: Positioned on the right side of the VME control racks and interface. Connectors: Equipped with two connectors, PSA and PSB, situated along the top edge. These connectors are specifically designed to link with a cable harness, facilitating the transmission of power to the VME rack. 

Output Specifications: It operates as a 300-watt 24 VDC power supply, featuring three +28V PSA outputs, with a combined 300W output rating. Additionally, it includes a Status ID output. Redundancy Support: Designed to support redundant operations, ensuring continuous and uninterrupted power supply in critical scenarios. 

The power supply unit is encased with a faceplate secured by screws at multiple locations. This faceplate design allows for secure closure while providing access to several panels, enabling convenient accessibility for maintenance or inspection purposes. SPEED (PULSE RATE) INPUTS MONITORING The VTUR card oversees four-speed inputs derived from passive magnetic sensors. Additionally, the servo card VSVO manages two-speed inputs (pulse rate), compatible with both passive and active speed sensors. These pulse rate inputs within the VSVO card commonly facilitate flow-divider feedback within servo loops. 

The frequency range supported for these inputs spans from 2kHz to 14kHz, exhibiting ample sensitivity at 2Hz, enabling the detection of zero speed from a 60-toothed wheel. Furthermore, the Backup Protection Module, divided into three sections, accommodates the monitoring of two additional passive speed sensors. This function primarily serves emergency overspeed protection for turbines lacking a mechanical overspeed bolt. For data communication and exchange between the Backup Protection Module and the Control Module(s), including cross-tripping capability, IONet serves as the underlying communication protocol. 

It's important to note that despite the IONet's communication capabilities, both modules retain the ability to independently initiate system trips without relying solely on the IONet interface. POWER SUPPLY REMOVAL Loosen the PSA/PSB Bracket Captive Fastener: Begin by loosening the captive fastener located at the top front of the PSA/PSB bracket assembly. This fastener secures the bracket to the power supply module (RPSM), and loosening it allows for disassembly. Separate the PSA/PSB Bracket Assembly: Once the captive fastener is loosened, separate the PSA/PSB bracket assembly from the RPSM. This step involves gently pulling the bracket assembly away from the power supply module to create space for further disconnection. 

Disconnect the Bottom Connectors: With the bracket assembly separated, proceed to disconnect the bottom connectors. These connectors are typically located at the bottom of the power supply module and are responsible for electrical connections. Loosen the Front Sheet Metal Bracket Captive Fasteners: Next, loosen the captive fasteners securing the front sheet metal bracket. These fasteners are typically located at the front of the power module assembly and hold the bracket in place. Pull the Sheet Metal Bracket/Power Module Assembly Forward: Once the front sheet metal bracket captive fasteners are loosened, carefully pull the sheet metal bracket/power module assembly forward. This movement creates space for accessing the rear side connectors. Disconnect the Rear Side Connectors: With the assembly pulled forward, proceed to disconnect the four rear side connectors. 

These connectors are typically located at the rear of the power module assembly and facilitate electrical connections. Slide the Assembly Off of the Control Rack: After disconnecting the rear side connectors, slide the sheet metal bracket/power module assembly off of the control rack. This step involves gently maneuvering the assembly to release it from the rack's mounting points. Remove the Mounting Screws: Finally, locate and remove the four mounting screws that secure the RPSM to the bracket. These screws hold the power supply module in place and must be removed to fully disengage the module from the bracket.

SPECIFICATIONS:

Part Number: IS2020SSRKG2
Manufacturer: General Electric
Series: Mark VI
Number of Channels: 8
Microprocessor: Intel Celeron 650 MHz
Memory: 128 MB SDRAM
Operating system: QNX
Programming: Boolean
Input Voltage: 24 VDC
Output Power: 300W
Product Type: VME Rack Main Power Supply Module
Maximum Lead Resistance: 15 Ω
Operating temperature: 0 to 60° C
Technology: Surface mount
Size: 16.2 cm high x 8.6 cm
Repair: 3-7 Day
Availability: In Stock
Country of Origin: United States


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ADLINK SP2-EHL Fanless Tablet Selection and Configuration Guide
  • ADLINK PXIS-2719A Chassis Deployment Monitoring Guide
  • ADLINK PXIe-9908 SMU Deployment and Configuration Guide
  • ADLINK PXIe-9852 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9848 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9834 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9529H Dynamic Signal Acquisition Configuration Guide
  • ADLINK PXIe-3988 Xeon Deployment Optimization Guide
  • ADLINK PXIe-3987/3977/3937 Deployment and Debugging
  • ADLINK PXIe-3987 Installation and Configuration Programming Guide
  • ADLINK-PXIe-3988-3987-3977-3937-TL Controller Deployment and Maintenance Guide
  • ADLINK PXI-2020/2022 Synchronous Acquisition Card Configuration and Synchronization Guide
  • ADLINK DAQ/PXI-2000 series synchronous acquisition card configuration and triggering
  • ADLINK PXES-2788 series chassis deployment and maintenance
  • ADLINK PXES-2785 18 Slot Gen3 Chassis Deployment and Maintenance Guide
  • ADLINK PXES-2780 18 Slot PXIe Chassis Deployment Configuration
  • ADLINK PXES-2596 Gen3 Chassis Installation and Maintenance Guide
  • ADLINK PXES-2590 Chassis Deployment and System Management
  • ADLINK PXES-2314T Chassis Deployment and Troubleshooting Guide
  • ADLINK PXES-2301 Chassis Installation Monitoring and Troubleshooting
  • ADLINK PCIe-U300 Series USB3 Vision Acquisition Card Deployment Guide
  • ADLINK PCIe PXIe-8565 Expansion Kit Remote Control and Compatibility
  • Installation and troubleshooting of ADLINK PCIe GIE74V four channel PoE acquisition card
  • ADLINK PCIe GIE7x Poe+Acquisition Card Configuration and Triggering Troubleshooting
  • Advanced triggering and multi card synchronization of ADLINK PCIe-CPL64V image acquisition card
  • ADLINK PCIe-CPL64 Image Acquisition Card Hardware Trigger and Encoder Application
  • Application and troubleshooting of ADLINK PCIe-8560/PXI-8565 expansion kit
  • ADLINK PCIe 8332/PCIe 8334/PCIe 8338 EtherCAT Motion Controller Multi axis Synchronous Control
  • ADLINK PCIe-7432 32 channel isolated I/O card interrupt and driver
  • ADLINK PCIe-7256 Industrial I/O Card Interruption and Relay
  • ADLINK PCIe-833x EtherCAT Motion Controller Debugging and Maintenance
  • ADLINK PCIe-10GPoE 10GigE Visual Acquisition Card Practical Use
  • ADLINK PCI-8254/8258 Motion Controller Debugging and Maintenance
  • Application and Maintenance of ADLINK PCI-8158 Multi axis Motion Control Card
  • ADLINK PCI-8134A Maintenance and Troubleshooting Guide
  • ADLINK PCI-7250 Series Relay Output Card Configuration and Protection Circuit Guide
  • ADLINK PCI-6308 Series Isolated Analog Output Card Configuration and Programming
  • ADLINK PanKonix Series HMI Panel Selection and Deployment Guide
  • ADLINK NuDAM-6100 Series I/O Module Deployment and Protocol Optimization
  • Deployment and Calibration of ADLINK NuDAM-6000 Data Acquisition Module
  • ADLINK NEON-2000-Ono Intelligent Camera Deployment and Trigger Optimization
  • ADLINK NuDAM-65xx Communication Module Networking and Configuration Guide
  • ADLINK NuDAM-60xx Series Digital I/O Module Deployment and Watchdog Optimization
  • ADLINK MXE-5300 Fanless Industrial Control Computer Deployment and Troubleshooting Manual
  • ADLINK MXE-310 edge computing Platform Hardware Installation and BIOS Tuning
  • ADLINK MXE-230 series Alder Lake platform industrial computer deployment and maintenance manual
  • ADLINK MXE-210 Compact Fanless Industrial Control Computer Hardware Deployment and Debugging Guide
  • ADLINK MXC-3300/3340 Embedded Industrial Control Computer Hardware Integration and Debugging Manual
  • ADLINK MXA-312M Edge AI Platform Hardware Integration and Debugging Guide
  • ADLINK MXA-200 IoT Gateway Hardware Installation and Linux System Debugging Complete Guide
  • ADLINK MVP-6200 Industrial Control Computer: PCIe Gen4 and PCI Hybrid Expansion
  • ADLINK MVP-6100 Industrial Control Computer: PCI/PCIe Expansion and Robust Design
  • ADLINK MVP-5200 Industrial Control Computer: High Performance Multi Display and TSN Network
  • ADLINK MVP-5100 Fanless Industrial Control Computer Deployment and Development Guide
  • ADLINK MVP-3100 and MVP-3120 Embedded Systems
  • ADLINK MNET-J3/S23/MIA/DA2/SAN Single Axis Module Installation and Wiring Guide
  • ADLINK MNET-4XMO/C Motion Module Installation and Debugging Guide
  • ADLINK MCM-216/218 Edge DAQ Deployment Configuration Guide
  • ADLINK LPCIe-8124-C Encoder Card Trigger Configuration Guide
  • ADLINK IM/OM Series Industrial Display Installation and Debugging Guide
  • ADLINK GW-01 Industrial IoT Gateway Configuration and Debugging Guide
  • EURESYS Grablink Collection Card Selection and Trigger Configuration Guide
  • ADLINK Express HL Module Selection and Heat Dissipation Configuration Guide
  • ADLINK EOS-2000 Visual System Installation and Troubleshooting
  • ADLINK EOS-1200 Installation, Configuration, and Troubleshooting
  • Application and Configuration of ADLINK ECS-8582-4S Extension System
  • ADLINK DIN-814P-A4 Panasonic servo adapter board configuration
  • ADLINK DIN-814M-J3A Mitsubishi servo adapter board configuration
  • ADLINK DIN-814-GP Universal Adapter Board Configuration
  • Application and Configuration of ADLINK DIN-812M Adapter Board
  • Application and Configuration of ADLINK DIN-814Y Adapter Board
  • ADLINK DAQ/DAQE/PXI-250x waveform generation complete guide
  • ADLINK DAQ/DAQE/PXI-220x acquisition card fully configured
  • Application and Configuration of ADLINK cPCI-9116 Data Acquisition Card
  • ADLINK cPCI/PCI-8554/R: A Complete Guide from Architecture to Application
  • ADLINK cPCI-7432/7433/7434 isolated I/O card
  • ADLINK cPCI-3544/3534/3538 Serial Cardcard Configuration Practice
  • ADLINK cPCI-3534/3538/3544 Multi Serial Port Card Configuration Complete Solution
  • Complete Technical Guide for Euresys Coaxlink CXP Capture Card
  • ADLINK AMP-304C Advanced Motion Control Card Complete Guide
  • ADLINK AMP-104C Four Axis Motion Control Card
  • ADLINK NEON-1020/1040 Smart Camera
  • ADLINK USB-7230/7250 Isolation I/O Module Operation Manual
  • ADLINK SP-15W03 Intelligent Panel Integration and Configuration Manual
  • ADLINK AMP-20xC Interface Configuration and Wiring Guide
  • ADLINK 3488A GPIB Interface Card Selection Guide
  • Complete solution of ETEL TMB+torque motor selection parameters
  • ADLINK RTV series frame grabber deployment guide
  • ADLINK PCIe-FIW64/62 Image Acquisition Card Configuration Guide
  • ADLINK 6208/6216-GL Analog Output Card
  • ADLINK 723X Isolation I/O Card Configuration Guide
  • ADLINK PCI-9118 series high-speed DAQ card selection and DMA configuration
  • ADLINK PCI-9114 (A) Data Acquisition Card Selection and Configuration Guide
  • ADLINK PCI-7442/7443/7444 Isolation I/O Card Selection and Safety Configuration
  • ADLINK PCI-7250/7251 Relay Output Card Selection and Expansion Guide
  • Selection and Protection Configuration of Advantech PCI-1610CU Multi Serial Port Card
  • ADLINK NEON-1000-MDX Smart Camera Deployment and Trigger Configuration
  • ADLINK MXE-1300 Industrial Control Computer Selection and Deployment Guide
  • ADLINK MXE-200 Industrial Control Computer Deployment and BIOS Optimization Guide
  • ADLINK LPCIe-3488A GPIB Card Installation and Configuration Guide
  • Guidelines for Key Technologies of ETEL LMG/LMS Linear Motor Integration
  • ETEL IL+/LM Linear Motor Selection and Integration Guide
  • ETEL DSCDP/DSCDL/DSCDM Dual Axis Controller Debugging Guide
  • ETEL DSCDL Dual Axis Controller Hardware Integration Guide
  • ETEL DSB2P Series Servo Amplifier Connection and Configuration Guide
  • ETEL DSC2P/DSC2V Servo Controller Debugging Guide
  • DFI HD636-H81CS Industrial Motherboard Deployment and Debugging
  • Integration and Optimization of ADLINK DAQ-20xx Synchronous Acquisition Card
  • ADLINK cPCI-6530 Core i7 Blade Computer Deployment Guide
  • ADLINK cPCI-3610 Blade Computer Integration and Debugging
  • ADLINK AMP-204C/208C Troubleshooting Guide
  • ADLINK AmITX ALN Industrial Motherboard Characteristics and Application Analysis
  • ADLINK NuPRO-850 Motherboard Installation and Configuration Guide
  • ADLINK MI-965 Motherboard Installation and BIOS Configuration Guide
  • ADLINK M-302 Industrial Motherboard Installation and BIOS Optimization Guide
  • ADLINK PXI-3920/3910 Controller Installation and Configuration Guide
  • ADLINK PCI-8132 Motion Control Card Installation, Programming, and Debugging Guide
  • ADLINK cPCI-6760D/P7/P8 Module Installation and Hot Plug Guide
  • ADLINK ACL-7122 Digital I/O Card Installation and Programming
  • ADLINK NuPRO-775 Industrial Motherboard Installation and BIOS Configuration Detailed Explanation
  • ETEL Accuret MODULAR 300/400/600 Controller Selection Guide
  • Edwards CTI Kryogenics On Board 8F Enhanced Cryopump Explanation
  • ADLINK PCI-9112 Multi functional Data Acquisition Card
  • ADLINK PCI-8102 Two Axis Pulse Motion Control Card
  • ADLINK PCI-9812/10 high-speed synchronous acquisition card
  • ADLINK PCI-7200 High Speed Digital I/O Card
  • ADLINK MXE-1000 series fanless industrial computer
  • ADLINK IMB-T10 Mini ITX Embedded Motherboard