Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS420ESWAH3A Ethernet IONet Switch
    ❤ Add to collection
  • GE IS420ESWAH3A Ethernet IONet Switch

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS420ESWAH3A Ethernet IONet Switch

    • ¥32694.14
      ¥32578.02
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.580KG
    • Quantity:
    • (Inventory: 88)
Description

GE IS420ESWAH3A Ethernet IONet Switch


GE IS420ESWAH3A Ethernet IONet Switch

Part Number IS420ESWAH3A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS420ESWAH3A is an IONet Ethernet Switch developed by GE and is part of the General Electric Speedtronic Mark VIe gas turbine control systems. It uses Achilles-certified controllers and current Fieldbus technology to meet NERC version 5 Protection Reliability Standards for Critical Infrastructure. 

The component has eight ports with 10/100BASE-TX capability. It's one of numerous Ethernet switch models available for use with the Mark VIe system. It features a conformal coating and is suitable for usage in hazardous environments. The machine can function in temperatures ranging from -40 to 158 degrees Fahrenheit. IS420ESWAH3A Features Compatibility with 802.3, 802.3u, and 802.3x 10/100 base copper with auto-negotiation Full/half duplex auto-negotiation 100 Mbps FX uplink port HP-MDIX auto-sensing Link Presence, Activity, Duplex, and Speed per port LEDs (each LED has two colors) Power LED 256 KB buffer with 4K media access control (MAC) addresses Flow Control Flow control between switches is supported by the switch. 

It receives and honors pause packets using IEEE defined pause packets. The switch only sends pause packets if a port requires flow control. IONet Ethernet Switch Reliability and Performance Because high reliability is critical in the controls solutions industry, the switch has a Mean Time Between Failure (MTBF) of more than 4 million hours at 35C (95 F) ambient temperature, ground fixed controlled environment. Product Attributes Mounting The switch enclosure can be panel mounted (the switch is bracket mounted to the back wall of the panel) or DIN-rail mounted. DIN-rail mounting satisfies vibration and shock requirements. 

Both mounting types allow for easy access to user connections. Dimensions 138 x 86 x 56 mm (5.45 x 3.40 x 2.20 in) Power Connection Supports two redundant diode-ORd power supply inputs of 18 to 36 V dc Cooling Convection cooled when mounted vertically or horizontally Coating Resistant to corrosion with provisions made for grounding per IEC 60721-3-3 Class 3C2 Operating temperature -30 to 65脗掳C (-22 to 149 F) Shipping, storage temperature -40 to 85C (-40 to 185 F) Humidity Operates in a 5 to 95% relative humidity, non-condensing environment without any external temperature or humidity excursions Seismic Vibration Meets Universal Building Code (UBC) Diagnostics Link presence, activity and duplex, and port speed LEDs have two colors that indicate their status. LED One Full Duplex activity is indicated by a green flash. Yellow flashes for activity at Half Duplex LED Two Green indicates a link and 100 Mb. 

Yellow indicates a link and 10 Mb. No link = no led lit IS420ESWAH3A Benefits Longer availability of parts for future network expansion Backward compatibility with legacy systems Improved performance for real-time control systems IS420ESWAH3A Conformance Criteria IEEE 1588 timing can be used to synchronize packet traffic and trigger it to begin within a 1-microsecond packet start window. The following four criteria are used to assess capability and conformance: Starting the required Multicast packet load on a single port without negotiating IEEE 802.3x flow control Begin the required Multicast packet load on a single port, with IEEE 802.3x flow control negotiated Initiation of the required Multicast packet load distributed across all ports, with no IEEE 802.3x flow control. Start the required packet Multicast load across all ports; packet count per port must average 200 per number of switch ports, with IEEE 802.3x flow control negotiated on half of the ports.

SPECIFICATIONS:

Part Number: IS420ESWBH3A
Manufacturer: General Electric
Series: Mark VIe
Product Type: Ethernet IONet Switch
Software: ControlST V04.03.18C
Relative humidity: 5% to 95%, no-condensing
Power Requirements +32 V dc to 18 V dc
Memory: 256 MB DDR SDRAM
Operating System: QNX Neutrino
Weight: 2 lbs
Dimensions: 138 x 86 x 56 mm
Availability: In Stock
Country of Manufacturer: United States (USA)

FUNCTIONAL DESCRIPTION:

IS420ESWBH3A is an Ethernet IONet Switch manufactured and designed by General Electric as part of the Mark VIe Series used in GE Distributed Gas Turbine Control Systems. It is available in 8 ports, 10/100BASE-TX. The ESWB Ethernet 10/100 switches are specially designed to meet the needs of real-time industrial control solutions and are required for all IONet switches used in Mark VIe & VIeS safety control systems. It is a DIN - Rail mounting module. To meet the requirements for speed and functionality the following features are provided.

802.3, 802.3U, 802.x, compatibility

10/100 based copper with auto-negotiation

Full/half duplex auto-negotiation

100 Mbps FX - Uplink port

HP - MDIX auto-sensing

LEDs”s to indicate the status of link presents, activity, duplex, and speed port (each LED has two colors)

LED to indicate power status

Minimum 256kb buffer with 4k media access control (MAC) address.

Redundant power supply inputs


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications
  • Bonfiglioli 300 series reducer installation, maintenance, and troubleshooting guide
  • Selection and integration guide for Bonfiglioli R3 series planetary gearboxes in primary crushing equipment
  • Bonfiglioli C-series ATEX gearbox selection and explosion-proof application guide
  • Bonfiglioli Vectron EM-ENC-05 Full Function Expansion Module Integration Guide
  • Bonfiglioli Vectron EM-ENC-04 Multi functional Expansion Module Complete Configuration Guide
  • Bonfiglioli Vectron EM-ENC-03 Second Encoder Interface and System Bus Expansion Guide
  • Bonfiglioli Vectron EM-ENC-02 Expansion Module Integration and Encoder Interface Guide
  • Bonfiglioli Vectron CM-CAN CANopen Communication Configuration and DS402 Control Guide
  • Bonfiglioli Vectron EM-SYS System Bus Networking and Virtual Link Configuration Guide
  • Bonfiglioli Vectron CM-PDP Profibus DP Configuration and Debugging Guide
  • Bonfiglioli Vectron CM-232/485 Modbus Communication Configuration Guide
  • Bonfiglioli BMS series servo reduction motor selection and integration guide
  • Bonfiglioli ACTION 210/410 Inverter Debugging and Fault Diagnosis Complete Guide
  • Honeywell Enhanced Micro TDC 3000X System Redundancy Architecture and Maintenance Guide
  • Selection and Configuration of Bonfiglioli Active Series Inverter
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli HDP/HDO Series Heavy duty Gearboxes
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli 300/300M Series Gearboxes
  • Bonfiglioli 300M planetary gearbox selection and thermal verification guide
  • Bonfiglioli 3/H series heavy-duty gearbox selection and verification guide
  • Bonfiglioli KRG/KCG/KSD Hydraulic Coupling Selection and Integration Guide