    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS420ESWAH3A Ethernet IONet Switch

    • ¥32694.14
      ¥32578.02
      ¥32694.14
      ¥32694.14
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.580KG
    • Quantity:
    • (Inventory: 88)
Description

GE IS420ESWAH3A Ethernet IONet Switch


GE IS420ESWAH3A Ethernet IONet Switch

Part Number IS420ESWAH3A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS420ESWAH3A is an IONet Ethernet Switch developed by GE and is part of the General Electric Speedtronic Mark VIe gas turbine control systems. It uses Achilles-certified controllers and current Fieldbus technology to meet NERC version 5 Protection Reliability Standards for Critical Infrastructure. 

The component has eight ports with 10/100BASE-TX capability. It's one of numerous Ethernet switch models available for use with the Mark VIe system. It features a conformal coating and is suitable for usage in hazardous environments. The machine can function in temperatures ranging from -40 to 158 degrees Fahrenheit. IS420ESWAH3A Features Compatibility with 802.3, 802.3u, and 802.3x 10/100 base copper with auto-negotiation Full/half duplex auto-negotiation 100 Mbps FX uplink port HP-MDIX auto-sensing Link Presence, Activity, Duplex, and Speed per port LEDs (each LED has two colors) Power LED 256 KB buffer with 4K media access control (MAC) addresses Flow Control Flow control between switches is supported by the switch. 

It receives and honors pause packets using IEEE defined pause packets. The switch only sends pause packets if a port requires flow control. IONet Ethernet Switch Reliability and Performance Because high reliability is critical in the controls solutions industry, the switch has a Mean Time Between Failure (MTBF) of more than 4 million hours at 35C (95 F) ambient temperature, ground fixed controlled environment. Product Attributes Mounting The switch enclosure can be panel mounted (the switch is bracket mounted to the back wall of the panel) or DIN-rail mounted. DIN-rail mounting satisfies vibration and shock requirements. 

Both mounting types allow for easy access to user connections. Dimensions 138 x 86 x 56 mm (5.45 x 3.40 x 2.20 in) Power Connection Supports two redundant diode-ORd power supply inputs of 18 to 36 V dc Cooling Convection cooled when mounted vertically or horizontally Coating Resistant to corrosion with provisions made for grounding per IEC 60721-3-3 Class 3C2 Operating temperature -30 to 65脗掳C (-22 to 149 F) Shipping, storage temperature -40 to 85C (-40 to 185 F) Humidity Operates in a 5 to 95% relative humidity, non-condensing environment without any external temperature or humidity excursions Seismic Vibration Meets Universal Building Code (UBC) Diagnostics Link presence, activity and duplex, and port speed LEDs have two colors that indicate their status. LED One Full Duplex activity is indicated by a green flash. Yellow flashes for activity at Half Duplex LED Two Green indicates a link and 100 Mb. 

Yellow indicates a link and 10 Mb. No link = no led lit IS420ESWAH3A Benefits Longer availability of parts for future network expansion Backward compatibility with legacy systems Improved performance for real-time control systems IS420ESWAH3A Conformance Criteria IEEE 1588 timing can be used to synchronize packet traffic and trigger it to begin within a 1-microsecond packet start window. The following four criteria are used to assess capability and conformance: Starting the required Multicast packet load on a single port without negotiating IEEE 802.3x flow control Begin the required Multicast packet load on a single port, with IEEE 802.3x flow control negotiated Initiation of the required Multicast packet load distributed across all ports, with no IEEE 802.3x flow control. Start the required packet Multicast load across all ports; packet count per port must average 200 per number of switch ports, with IEEE 802.3x flow control negotiated on half of the ports.

SPECIFICATIONS:

Part Number: IS420ESWBH3A
Manufacturer: General Electric
Series: Mark VIe
Product Type: Ethernet IONet Switch
Software: ControlST V04.03.18C
Relative humidity: 5% to 95%, no-condensing
Power Requirements +32 V dc to 18 V dc
Memory: 256 MB DDR SDRAM
Operating System: QNX Neutrino
Weight: 2 lbs
Dimensions: 138 x 86 x 56 mm
Availability: In Stock
Country of Manufacturer: United States (USA)

FUNCTIONAL DESCRIPTION:

IS420ESWBH3A is an Ethernet IONet Switch manufactured and designed by General Electric as part of the Mark VIe Series used in GE Distributed Gas Turbine Control Systems. It is available in 8 ports, 10/100BASE-TX. The ESWB Ethernet 10/100 switches are specially designed to meet the needs of real-time industrial control solutions and are required for all IONet switches used in Mark VIe & VIeS safety control systems. It is a DIN - Rail mounting module. To meet the requirements for speed and functionality the following features are provided.

802.3, 802.3U, 802.x, compatibility

10/100 based copper with auto-negotiation

Full/half duplex auto-negotiation

100 Mbps FX - Uplink port

HP - MDIX auto-sensing

LEDs”s to indicate the status of link presents, activity, duplex, and speed port (each LED has two colors)

LED to indicate power status

Minimum 256kb buffer with 4k media access control (MAC) address.

Redundant power supply inputs


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice