Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS420ESWAH3A Ethernet IONet Switch
    ❤ Add to collection
  • GE IS420ESWAH3A Ethernet IONet Switch

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS420ESWAH3A Ethernet IONet Switch

    • ¥32694.14
      ¥32578.02
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.580KG
    • Quantity:
    • (Inventory: 88)
Description

GE IS420ESWAH3A Ethernet IONet Switch


GE IS420ESWAH3A Ethernet IONet Switch

Part Number IS420ESWAH3A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS420ESWAH3A is an IONet Ethernet Switch developed by GE and is part of the General Electric Speedtronic Mark VIe gas turbine control systems. It uses Achilles-certified controllers and current Fieldbus technology to meet NERC version 5 Protection Reliability Standards for Critical Infrastructure. 

The component has eight ports with 10/100BASE-TX capability. It's one of numerous Ethernet switch models available for use with the Mark VIe system. It features a conformal coating and is suitable for usage in hazardous environments. The machine can function in temperatures ranging from -40 to 158 degrees Fahrenheit. IS420ESWAH3A Features Compatibility with 802.3, 802.3u, and 802.3x 10/100 base copper with auto-negotiation Full/half duplex auto-negotiation 100 Mbps FX uplink port HP-MDIX auto-sensing Link Presence, Activity, Duplex, and Speed per port LEDs (each LED has two colors) Power LED 256 KB buffer with 4K media access control (MAC) addresses Flow Control Flow control between switches is supported by the switch. 

It receives and honors pause packets using IEEE defined pause packets. The switch only sends pause packets if a port requires flow control. IONet Ethernet Switch Reliability and Performance Because high reliability is critical in the controls solutions industry, the switch has a Mean Time Between Failure (MTBF) of more than 4 million hours at 35C (95 F) ambient temperature, ground fixed controlled environment. Product Attributes Mounting The switch enclosure can be panel mounted (the switch is bracket mounted to the back wall of the panel) or DIN-rail mounted. DIN-rail mounting satisfies vibration and shock requirements. 

Both mounting types allow for easy access to user connections. Dimensions 138 x 86 x 56 mm (5.45 x 3.40 x 2.20 in) Power Connection Supports two redundant diode-ORd power supply inputs of 18 to 36 V dc Cooling Convection cooled when mounted vertically or horizontally Coating Resistant to corrosion with provisions made for grounding per IEC 60721-3-3 Class 3C2 Operating temperature -30 to 65脗掳C (-22 to 149 F) Shipping, storage temperature -40 to 85C (-40 to 185 F) Humidity Operates in a 5 to 95% relative humidity, non-condensing environment without any external temperature or humidity excursions Seismic Vibration Meets Universal Building Code (UBC) Diagnostics Link presence, activity and duplex, and port speed LEDs have two colors that indicate their status. LED One Full Duplex activity is indicated by a green flash. Yellow flashes for activity at Half Duplex LED Two Green indicates a link and 100 Mb. 

Yellow indicates a link and 10 Mb. No link = no led lit IS420ESWAH3A Benefits Longer availability of parts for future network expansion Backward compatibility with legacy systems Improved performance for real-time control systems IS420ESWAH3A Conformance Criteria IEEE 1588 timing can be used to synchronize packet traffic and trigger it to begin within a 1-microsecond packet start window. The following four criteria are used to assess capability and conformance: Starting the required Multicast packet load on a single port without negotiating IEEE 802.3x flow control Begin the required Multicast packet load on a single port, with IEEE 802.3x flow control negotiated Initiation of the required Multicast packet load distributed across all ports, with no IEEE 802.3x flow control. Start the required packet Multicast load across all ports; packet count per port must average 200 per number of switch ports, with IEEE 802.3x flow control negotiated on half of the ports.

SPECIFICATIONS:

Part Number: IS420ESWBH3A
Manufacturer: General Electric
Series: Mark VIe
Product Type: Ethernet IONet Switch
Software: ControlST V04.03.18C
Relative humidity: 5% to 95%, no-condensing
Power Requirements +32 V dc to 18 V dc
Memory: 256 MB DDR SDRAM
Operating System: QNX Neutrino
Weight: 2 lbs
Dimensions: 138 x 86 x 56 mm
Availability: In Stock
Country of Manufacturer: United States (USA)

FUNCTIONAL DESCRIPTION:

IS420ESWBH3A is an Ethernet IONet Switch manufactured and designed by General Electric as part of the Mark VIe Series used in GE Distributed Gas Turbine Control Systems. It is available in 8 ports, 10/100BASE-TX. The ESWB Ethernet 10/100 switches are specially designed to meet the needs of real-time industrial control solutions and are required for all IONet switches used in Mark VIe & VIeS safety control systems. It is a DIN - Rail mounting module. To meet the requirements for speed and functionality the following features are provided.

802.3, 802.3U, 802.x, compatibility

10/100 based copper with auto-negotiation

Full/half duplex auto-negotiation

100 Mbps FX - Uplink port

HP - MDIX auto-sensing

LEDs”s to indicate the status of link presents, activity, duplex, and speed port (each LED has two colors)

LED to indicate power status

Minimum 256kb buffer with 4k media access control (MAC) address.

Redundant power supply inputs


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Yokogawa AIP830 Single Circuit Operation Keyboard
  • Yokogawa RAMC flowmeter selection and troubleshooting
  • YASKAWA GA500 frequency converter troubleshooting
  • TRACO TIS600 power supply
  • Sigmatek ETV-0851 Control Panel Troubleshooting
  • Allen Bradley Quest AN-X2-AB-DHRIO Remote I/O Adapter Integration and Troubleshooting
  • Meggitt RPS6U power supply
  • Kongsberg RCU500 Controller Integration and Fault Diagnosis Guide
  • KBAC series frequency converter installation and fault diagnosis guide
  • EXOR effectiveness View eV058 series HMI industrial panel
  • Emerson OCR3000 Controller Troubleshooting Guide
  • Emerson Ovation OCR1100 Controller Maintenance and Troubleshooting
  • Elmo G-TUB30 Driver Troubleshooting Guide
  • Troubleshooting and Optimization of Basler A400 Series Camera
  • Troubleshooting and Maintenance of Automated Logic I/O Expansion Module
  • Troubleshooting and Maintenance of Aerotech UNIDEX 100 Controller
  • ADVANEST R6144 calibration source troubleshooting
  • Troubleshooting and Calibration of ABB Millmate Tension Gauge
  • ABB NGC8206 natural gas chromatograph troubleshooting and maintenance
  • ABB AO2040-CU Ex Explosion proof Analyzer Troubleshooting
  • ABB PFEA113 Tension Controller Troubleshooting Guide
  • ABB PFEA111/112/122 Tension Controller Troubleshooting Guide
  • ABB LS4000 laser analyzer
  • ABB SPAU 341 C Voltage Regulator Troubleshooting Guide
  • Analysis and Fault Diagnosis of ABB V-Contact VSC Medium Voltage Contactor
  • ABB UNITOL 1020 Compact Digital Excitation Regulator AVR Replacement and Troubleshooting
  • ABB UNITROL 1000 excitation system replacement and troubleshooting
  • ABB SYNC HROTACT 5 synchronization module troubleshooting and replacement
  • ABB SYNC HROTACT 5 Synchronization Device Replacement and Troubleshooting Guide
  • ABB Symphony Plus Module Replacement and Upgrade Guide
  • ABB S900 I/O Hazardous Area Deployment and Maintenance
  • ABB System 800xA Operations and Troubleshooting
  • ABB PCS6000 Troubleshooting and Module Replacement Guide
  • ABB PCS 8000 pumped storage excitation
  • ABB Procontrol P13 Bus Coupling Upgrade Guide
  • ABB NextMove ESB-2 Fault Diagnosis and Configuration Practice
  • ABB MEGADRIVE-LCI Maintenance and Selection Practice
  • ABB MEGADRIVE LCI Transmission Vibration Suppression
  • ABB MEGADRIVE LCI Water Cooling Troubleshooting and Maintenance Guide
  • Practical Maintenance and Common Troubleshooting of ABB DCS880
  • ABB SDCS-IOB-3 Replacement and Troubleshooting
  • ALSTOM MAE99-04 Serial Interface Terminal Panel Maintenance and Troubleshooting
  • Installation and Maintenance of ALSTOM ALSPA MV3000 Handheld Operator
  • Maintenance and commissioning of ABB KPM KB2 paper breakage detector
  • Maintenance and troubleshooting of ABB SCC-K converter
  • ABB SCC Gas Preprocessing System Maintenance and Selection Guide
  • ABB NGC8209 gas chromatograph maintenance
  • Maintenance and troubleshooting of ABB DCS DC speed controller
  • ABB ASTAT Crane Controller Maintenance and Debugging Guide
  • ABB ACS800 TIM foil IGBT
  • ABB LS25 laser analyzer troubleshooting
  • ABB REM54 motor terminal troubleshooting
  • ABB REL670 distance protection and troubleshooting
  • ABB SUE3000 switching device troubleshooting
  • ABB REF630 feeder protection
  • ABB REF620 (Relion 620 series) feeder protection and measurement device
  • ABB E1B-A Circuit Breaker
  • ABB FCU400-IR temperature measurement system troubleshooting
  • ABB TZIDC-200 locator configuration and troubleshooting
  • ABB DHH805-A Handheld Operator Configuration and Activation Guide
  • ABB SACO 16D1 alarm device replacement and troubleshooting
  • ABB 5SHY3545L0016 IGCT module replacement guide
  • ABB S600 I/O Module Replacement and Troubleshooting Guide
  • ABB NextMove e100 motion controller troubleshooting guide
  • Rockwell PowerFlex 700 Inverter Replacement and Troubleshooting Guide
  • Allen Bradley 1762-OW16 Output Module
  • Allen Bradley IntelliVAC 1503VC Series E Control Module
  • Allen‑Bradley IntelliVAC ™ 1503VC contactor control module
  • Woodward SOGAV 250 solenoid valve drives gas intake valve for troubleshooting
  • Woodward easyYgen-3500XT-P1 obstacle removal
  • Woodward CPC-II electro-hydraulic current pressure converter
  • UniOP ePALM10 Handheld HMI
  • TMEIC TMdrive-30 frequency converter
  • TEWS TVME200 Carrier Board Configuration and Troubleshooting Guide
  • TDK Alpha 400 Power Troubleshooting Guide
  • STUCKE SYMAP relay
  • Deployment and troubleshooting of Softing CAN-AC2-PCI interface card
  • Installation, Maintenance, and Troubleshooting of Siemens C7-623/624
  • Foxboro Compact 200 Series 16 Slot Bottom Plate Deployment and Maintenance Guide
  • Foxboro 84F/84W Vortex Flow Meter Selection and Debugging Guide
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller
  • DATA PATTERNS DP-VME-5114 Dual PMC Carrier Board Integration and Troubleshooting
  • CMZ SVM1608 Intelligent Servo Driver
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide
  • SUMITOMO ELECTRIC AC1135U Small Parts Turning Application Guide
  • SUMITOMO ELECTRIC AC1030U Precision Machining Selection and Practice for Small Parts
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection
  • BENDER RCMA475LY Residual Current Monitoring
  • BENDER IRDH575 Insulation Monitoring
  • BENDER IRDH265 Insulation Monitoring and Debugging
  • Bender RCMA475LY residual current monitor debugging
  • Beckwith Electric M-3425A Generator Protection Relay Debugging Guide
  • Automated MEX816U Expander Troubleshooting Guide