  • ABB NKTU11-8 I/O Module to Termination Unit Cable
    ❤ Add to collection
  • ABB NKTU11-8 I/O Module to Termination Unit Cable

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    NKTU11-8 I/O Module to Termination Unit Cable
    • ¥5958.00
      ¥12828.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.000KG
    • Quantity:
    • (Inventory: 2)
Description
NKTU11-8 I/O Module to Termination Unit Cable

ABB NKTU11-8 I/O Module to Termination Unit Cable

Basic introduction

Product Overview: The ABB NKTU11 - 8 I/O Module to Termination Unit Cable is a cable used to connect I/O modules and terminal units, which plays a vital role in ABB automation systems such as Infi 90 or Net 90 systems. It is one of the key components of the entire automation system, as it is mainly used for the transmission of signals and ensures smooth communication between the I/O module and the termination unit.

Physical Characteristics: This cable usually has specific lengths and specifications to suit different installation environments and equipment layout requirements. For example, its length may have a variety of standard options, such as 1 metre, 2 metres, etc. The specific length is determined according to the actual application scenario. The core material of the cable is usually high-quality copper with good electrical conductivity, while the outer jacket material is a wear-resistant and corrosion-resistant insulating material, which is able to be used for a long period of time in industrial environments.

Functional characteristics

Signal transmission function

Multiple signal transmission: It can transmit multiple types of signals, including digital signals (e.g. switching signals) and analogue signals (e.g. voltage signals, current signals). For example, in industrial automation production lines, it can transmit signals from sensors (e.g. proximity switches, temperature sensors) to I/O modules, or control signals output from I/O modules to terminal units (e.g. relays, actuators).

Signal Integrity Guarantee: The signal integrity can be effectively maintained during transmission. It adopts shielding design (e.g. shield wrapping the wire core), which can reduce the influence of electromagnetic interference on the signal and ensure the accuracy and stability of the signal. For example, in some industrial places with complex electromagnetic environments, such as motor-intensive workshops, this shielding design can prevent the electromagnetic interference generated by motors from affecting signal transmission, thus ensuring the normal operation of the control system.

Connection compatibility

Adaptation to specific interfaces: The cable's plugs and sockets are designed to match ABB's specific I/O module and terminal unit interfaces, ensuring a tight and reliable connection. This customised interface design avoids signal interruptions or malfunctions due to poor connections or incompatible interfaces.

Supports system expansion and update: When the system needs to expand the I/O modules or update the terminal units, the cable can be easily reconfigured and reconnected to adapt to system changes. For example, when a company adds new sensors or actuators to improve production efficiency, the NKTU11-8 cable can easily connect these new devices to the existing automation system.

Technical Parameters

Electrical parameters

Rated voltage and current: the cable has a rated voltage and current carrying capacity, which depends on the type and size of the cable. For example, the rated voltage may be 300V AC/DC and the rated current may reach several amperes, which makes it capable of meeting the signal transmission requirements of most industrial control equipment.

Signal Transmission Rate: A certain signal transmission rate is supported to accommodate different I/O communication requirements. For digital signals, the transmission rate may reach several Mbps (megabits per second), which can meet the rapid transmission of digital signals, such as high-speed counter signal transmission; for analogue signals, it can ensure the accurate transmission of signals within a certain bandwidth, such as for the analogue signals in the audio range (20Hz - 20kHz) can be achieved with low distortion transmission.

Mechanical parameters

Cable length and diameter: There are various options for length, and the diameter is generally between a few millimetres and a dozen millimetres, depending on the number of cores inside the cable, the thickness of the shield and other factors. For example, a common cable length of 1 metre may have a diameter of around 6mm, while a length of 5 metres may have a diameter of around 8mm due to the addition of reinforcing cores and other structures.

Plug and socket specifications: Plug and socket sizes and pin definitions are specific to ABB equipment. For example, plugs may have a rectangular multi-pin design, with the number and arrangement of pins corresponding exactly to the interfaces of the I/O modules and terminal units, to ensure correct signal connections.

Environmental parameters

Operating Temperature Range: Capable of operating over a wide temperature range, generally around - 20°C - + 70°C. This temperature range covers the actual temperature environment of most industrial sites, and the cables work well in both cold outdoor installations and hot production halls.

Humidity range: the relative humidity range is usually 5% - 95% (non-condensing), which allows stable operation in humid environments and avoids performance degradation or failure due to humidity changes.

Protection level: With a certain protection level, such as IP40 or higher, it can prevent solid objects with a diameter greater than 1mm from entering and is waterproof to a certain extent, protecting the internal core and signal transmission from the external environment.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Advantest R6144 Programmable DC Voltage/Current Source (Calibration Source) Calibration and Maintenance
  • Aerotech UNIDEX 100/U100i single axis motion controller
  • Aerotech Ndrive MP Ultra Compact PWM Digital Servo Driver
  • Aerotech Ndrive HPe 10/20/30 High Performance PWM Digital Servo Drive
  • Aerotech Ndrive HLe maintenance replacement
  • Aerotech Ndrive CP maintenance replacement
  • Aerotech Ndrive Linear Drive Selection
  • Aerotech NDrive HL linear drive maintenance replacement
  • Aerotech NDrive HP 10/20/30 Maintenance and Replacement
  • Aerotech NDrive CP10 Servo Drive Guide
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications
  • Bonfiglioli 300 series reducer installation, maintenance, and troubleshooting guide
  • Selection and integration guide for Bonfiglioli R3 series planetary gearboxes in primary crushing equipment
  • Bonfiglioli C-series ATEX gearbox selection and explosion-proof application guide
  • Bonfiglioli Vectron EM-ENC-05 Full Function Expansion Module Integration Guide
  • Bonfiglioli Vectron EM-ENC-04 Multi functional Expansion Module Complete Configuration Guide
  • Bonfiglioli Vectron EM-ENC-03 Second Encoder Interface and System Bus Expansion Guide
  • Bonfiglioli Vectron EM-ENC-02 Expansion Module Integration and Encoder Interface Guide
  • Bonfiglioli Vectron CM-CAN CANopen Communication Configuration and DS402 Control Guide
  • Bonfiglioli Vectron EM-SYS System Bus Networking and Virtual Link Configuration Guide
  • Bonfiglioli Vectron CM-PDP Profibus DP Configuration and Debugging Guide