Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • ABB PFSA140RULM1I 3BSE06503R1 drum power supply device
    ❤ Add to collection
  • ABB PFSA140RULM1I 3BSE06503R1 drum power supply device

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    The MC68040 processor equipped in the module integrates integer operation units, floating point operation units (FPUs), and memory management units (MMUs), among which the floating point operation units can efficiently handle complex mathematical operations involved in industrial control, such as PID regulation, data filtering, etc., with an accuracy of IEEE 754 standard. At a frequency of 25MHz, the integer operation speed can reach 20 MIPS (millions of instructions per second), and the floating-point operation speed can reach 10 MFLOPS, which can meet the real-time requirements of multitasking concurrent processing scenarios, ensuring fast response and execution of control instructions.

    • ¥6684.00
      ¥7047.00
      ¥6684.00
      ¥6684.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:1.110KG
    • Quantity:
    • (Inventory: 99999)
Description

The MC68040 processor equipped in the module integrates integer operation units, floating point operation units (FPUs), and memory management units (MMUs), among which the floating point operation units can efficiently handle complex mathematical operations involved in industrial control, such as PID regulation, data filtering, etc., with an accuracy of IEEE 754 standard. At a frequency of 25MHz, the integer operation speed can reach 20 MIPS (millions of instructions per second), and the floating-point operation speed can reach 10 MFLOPS, which can meet the real-time requirements of multitasking concurrent processing scenarios, ensuring fast response and execution of control instructions.


ABB PFSA140RULM1I 3BSE06503R1 drum power supply device

Basic information of device core

Model identification

PFSA140RULLM1I 3BSE06503R1

3BSE06503R1 is the official exclusive order number of ABB, PFSA140RULLM11I is the functional model, indicating the power supply specifications and adaptation scenarios

Device Type

Industrial grade drum dedicated power supply device

Optimization of the characteristics of the conveyor drum drive motor, with load adaptation and protection functions

Input power specifications

AC 380V ± 15%, 50/60Hz three-phase

Adapt to industrial site standard three-phase power supply, with a wide voltage range to cope with grid fluctuations

Output power specifications

DC 48V, Rated output current 140A; supports short-term overload output (120% rated current, continuous for 10 seconds)

Provide stable power for the DC driven drum motor, with overload capacity meeting the motor starting requirements

Protection level

IP54 (shell), IP20 (internal wiring terminal)

Dustproof and splash proof design, suitable for dusty and humid industrial site environments

Overall dimensions

600mm (height) x 450mm (width) x 250mm (depth)

Modular structure design, easy to install inside the control cabinet or independently installed on the ground

weight

About 35kg

Adopting high-strength steel plate shell to enhance structural stability and impact resistance


Key performance characteristics

1. Efficient and stable power conversion capability

The device adopts advanced three-phase bridge rectification+PWM (pulse width modulation) voltage stabilization technology to convert the input three-phase 380V AC power into 48V DC power. The power conversion efficiency is over 92%, effectively reducing energy loss and minimizing the device's own heat generation. Internally integrated high-precision voltage regulation module, the output voltage fluctuation range is controlled within ± 0.5V, ensuring stable speed of the drum drive motor and avoiding uneven conveying speed caused by voltage fluctuations. At the same time, the device has excellent load adjustment rate (≤ 1%), and even in the scenario of sudden load changes when multiple rollers are started simultaneously, the output voltage can still remain stable, ensuring the synchronous operation of the conveying system.

2. Comprehensive security protection mechanism

To ensure the safe operation of the device and drum motor, multiple protection functions are integrated to form a comprehensive safety guarantee system: firstly, overload protection. When the output current exceeds 120% of the rated value and lasts for 10 seconds, the device automatically cuts off the output and alarms to prevent the motor from burning out due to overload; The second is short-circuit protection, which adopts a dual design of fast melting and electronic current limiting. The short-circuit response time is ≤ 1ms, and the fault circuit is quickly cut off to prevent the fault from expanding; The third is overvoltage/undervoltage protection. When the input voltage exceeds the range of AC 380V ± 15% or the output voltage rises abnormally, the device triggers protection and shuts down; The fourth is over temperature protection, which is equipped with a temperature sensor inside. When the temperature of the core components of the device exceeds 85 ℃, it will automatically reduce the capacity and run. When the temperature reaches 95 ℃, it will shut down to prevent damage to the components due to high temperature. In addition, the device also has anti reverse protection function to prevent damage to the motor or device caused by incorrect connection of the positive and negative poles of the output terminal.

3. Industrial grade environmental adaptability design

In response to the harsh operating environment of industrial sites, the device has undergone enhanced design in terms of structure and component selection. In terms of temperature adaptability, the working temperature range is -10 ℃~+55 ℃, and the storage temperature range is -40 ℃~+70 ℃, which can adapt to extreme temperature scenarios such as cold mines and high-temperature metallurgical workshops; The humidity adaptation range is 5%~95% (no condensation), and circuit boards treated with moisture-proof coatings can effectively resist the erosion of humid environments. In terms of anti-interference performance, the device has passed EN 61000-6-2 (industrial environment anti-interference) and EN 61000-6-4 (industrial environment emission) certification, with a surge impact protection capability of ± 2kV and an electrical fast transient pulse group protection capability of ± 1kV. It can effectively resist electromagnetic interference generated by on-site frequency converters, high-power motors and other equipment, ensuring its stable operation.

4. Flexible control and communication capabilities

The device supports two modes: local control and remote control, meeting the operational needs of different scenarios. Local control achieves functions such as start stop and parameter setting through buttons on the device panel. It is equipped with a high-definition LCD display screen, which displays real-time information such as input/output voltage, current, device temperature, and operating status. When there is a fault, the fault code can be directly displayed, making it easy for on-site personnel to quickly troubleshoot. In terms of remote control, the device integrates RS-485 communication interface, supports Modbus RTU communication protocol, and can be connected to PLC or industrial control system to achieve remote start stop control, parameter reading and modification, fault information uploading and other functions, facilitating centralized monitoring and intelligent management of the conveying system. In addition, the device reserves an expansion interface for PROFINET communication module, which can be upgraded to industrial Ethernet communication according to user needs, improving communication speed and networking flexibility.

5. Convenient maintenance and diagnostic functions

The device has a complete self diagnosis and maintenance friendly design: firstly, it has a built-in fault memory function, which can store the type, occurrence time, and operating parameters of the last 10 faults, and can query fault records through panel buttons or communication interfaces; Secondly, key components such as rectifier bridges, filtering capacitors, and fuses are designed modularly for quick replacement; The third is that the device is equipped with an independent ventilation and heat dissipation system, which adopts a combination design of dust-proof fan and heat dissipation fins. The fan speed can be automatically adjusted according to the temperature of the device, ensuring heat dissipation effect and reducing noise. At the same time, the fan has a fault alarm function to remind maintenance personnel to replace it in a timely manner. In addition, ABB provides specialized diagnostic software that can be connected to devices via USB interface for more accurate parameter configuration, performance testing, and fault diagnosis.


Installation and configuration points

1. Mechanical installation

The device supports two installation methods: one is installation inside the control cabinet, ensuring that the internal space of the control cabinet meets the device's heat dissipation needs. At least 150mm of heat dissipation space should be reserved between the device and the inner wall of the control cabinet and other equipment. The control cabinet should be equipped with ventilation fans or heat dissipation holes to ensure air circulation inside the cabinet; The second is independent ground installation, which requires the use of dedicated installation brackets for fixation. The brackets should have sufficient load-bearing capacity, and the installation ground should be flat and sturdy to avoid vibration transmission to the inside of the device. Regardless of the installation method used, it is necessary to ensure that the device is securely installed to avoid displacement or loose wiring caused by vibration during the operation of the conveying system. During the installation process, attention should be paid to protecting the device casing to avoid collisions that may cause a decrease in protective performance.

2. Electrical connection

Electrical connections must strictly follow the device wiring diagram and be operated by professional electricians to ensure safe and reliable connections. Firstly, for input power connections, copper core cables with a cross-sectional area of ≥ 16mm ² should be used to connect three-phase 380V power supplies. When wiring, it is necessary to distinguish between L1, L2, and L3 phase wires and neutral wires (N) and ground wires (PE). The ground wire must be reliably grounded with a grounding resistance of ≤ 4 Ω, and a circuit breaker (rated current 200A) should be installed in the input circuit to achieve first level protection; The second is to connect the output power supply, using copper core cables with a cross-sectional area of ≥ 50mm ² to connect the drum motor, ensuring that the cable current carrying capacity meets the 140A rated current requirement. When wiring, it is necessary to confirm that the positive and negative poles of the motor correspond to the output end of the device to avoid reverse connection; The third is the connection between communication and control lines. The RS-485 communication line uses shielded twisted pair cables, with the shielding layer grounded at one end. The control line and power line are separately wired with a spacing of ≥ 100mm to avoid electromagnetic interference. After the connection is completed, it is necessary to check the firmness of the wiring and the correctness of the polarity again. Only after confirming that there are no errors can the power be turned on.

3. System configuration and debugging

Device debugging needs to be carried out step by step to ensure that all parameters match the system requirements: first, check whether the input power supply voltage is around AC 380V before powering on, and confirm that the "emergency stop" button on the device panel is in the pressed state; Secondly, connect the input power supply, release the "emergency stop" button, and the device will enter standby mode. Check whether various parameters are normal through the panel LCD display screen (such as the preset output voltage of 48V); Then, perform no-load debugging, disconnect from the drum motor, start the device, measure whether the output voltage is stable at 48V, and close the device after confirming that there are no abnormalities; Finally, perform load debugging, connect the drum motor, start the device, observe the motor operation status, and monitor the output current, motor speed and other parameters through the panel or diagnostic software. If there are abnormal fluctuations in current or unstable motor operation, check whether the motor has faults or whether the device parameters need to be adjusted. When debugging remote control functions, communication parameters (baud rate, address, protocol) need to be configured in the PLC or control system to ensure normal communication with the device and accurate execution of remote control instructions.


Application scenarios and precautions

1. Typical application scenarios

-Mining Conveyor System: Provides power for the belt conveyor drum of coal mines and iron mines, adapts to harsh environments with high dust and vibration underground, and ensures continuous transportation of coal and ore.

-Port logistics: Used for the power supply of roller conveyors in container terminals, supporting synchronous operation of multiple rollers to meet the needs of rapid container transportation.

-Metallurgical industry: provides stable power supply for the raw material conveying drum and finished product conveying roller of steel plants, adapts to high temperature and high dust production environment, and ensures the smooth progress of metallurgical processes.

-Logistics warehousing: The conveyor drum used in automated three-dimensional warehouses, combined with intelligent control systems, achieves precise transportation and sorting of goods, improving warehousing efficiency.

-Building materials industry: used for supplying power to conveyor drums in cement and stone production lines, resisting dust and vibration interference, and ensuring the continuous operation of building materials production.

2. Precautions for use

1. The device must be installed, wired, and debugged by qualified professionals. Non professionals are strictly prohibited from operating it to avoid electric shock or equipment damage accidents.

During the operation of the device, it is strictly prohibited to open the casing. If maintenance or repair is required, the input power must be cut off first and wait for more than 10 minutes to ensure that the internal capacitor is completely discharged before proceeding with the operation.

3. Do not exceed the rated output parameters of the device, and it is strictly prohibited to short-circuit or connect the output terminal to a load beyond the rated voltage range, in order to avoid triggering the protection function or causing permanent damage.

4. Regular maintenance of the device: clean the dust on the heat dissipation holes of the shell and the fan filter screen every week; Check the firmness of the wiring terminals and the condition of the cable insulation layer every month; Quarterly testing of device performance parameters through diagnostic software and timely replacement of aging components.

When the device malfunctions, the fault code and on-site working conditions should be recorded first, and ABB professional after-sales service personnel should be contacted in a timely manner for maintenance. It is prohibited to disassemble or replace core components without authorization to avoid affecting the reliability and safety of the device.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Toshiba T1-16S Programmable Controller I/O Module Detailed Explanation
  • CE 680 M511 industrial piezoelectric accelerometer
  • Hardware Explanation of Meggitt VM600 MPS Mechanical Protection System
  • Meggitt Vibro meter VM600Mk2 Mechanical Protection and Condition Monitoring System
  • WAGO MCS Connection System
  • WAGO 281-611 Fuse Terminal Analysis
  • Watlow PPC-2000 System Deployment and Configuration Guide
  • Watlow MLS Controller Guide
  • Watlow 8LS Controller Setup Guide
  • Watlow Anafaze System 32 Hardware Installation Guide
  • Watlow ANAFAZE 12LS Installation and Operation Technical Guide
  • Baldor NextMove ST Motion Controller Technical Guide
  • Baldor MotiFlex e100 Servo Drive Installation Guide
  • Baldor FlexDrive II AC Guide
  • Baldor MicroFlex Servo Drive Professional Installation Guide
  • ABB MicroFlex servo drive characteristics and installation guide
  • Baldor BSM Series AC Servo Motor Analysis
  • Baldor Reliability CDPT3320 DC Motor
  • Baldor Reliability NEMA Super-E Ultra High Efficiency Motor Comprehensive Guide
  • Baldor Reliance Full Horsepower DC Motor Comprehensive Guide: From Technical Specifications to Industrial Application Selection
  • Comprehensive Guide to Baldor Motion Control Accessories: HMI Panels, Industrial Cables, Power Supplies, and EMC Filters
  • HIMA HICore 1 In Depth Analysis: A Comprehensive Guide to Functional Safety SoCs, Evaluation Kits, and T Ü V Certification
  • HIMA HIJunctionBox: Creating a New Era of Distributed Intelligent Security Platform
  • HIMA HIMatrix F35 Safety Controller: Specification Manual, SIL 3 Programming and Installation Guide
  • HIMA HIQuad X System Manual: Comprehensive and in-depth analysis of HIMA SIL 3 safety automation system
  • Deep Analysis of HIMA HIMax Safety Control System: Architecture, Redundancy, and Engineering Application Guidelines
  • In depth analysis of HIMA Planar4 system: SIL 4 level hard wired safety logic solution
  • What are the core protection mechanisms of WOODWARD Vertex's anti surge control?
  • Woodward Vertex Compressor Control System: Function, Application, and Installation Details
  • Woodward easYview miniSCADA visualization solution
  • Woodward easyYview Series: Technical Analysis of Mini SCADA Remote Control Panel Designed for Generator Sets and Switchgear
  • Woodward MicroNet Plus: High reliability redundant control system for prime mover control
  • Woodward easyYgen LS-6XT: A Multi Circuit Breaker Control Solution for Complex Power Management
  • Woodward easyYgen LS-6XT Circuit Breaker Control Unit: Technical Characteristics, Installation and Application Guide
  • Woodward LS-521 V2 (Option K12) Circuit Breaker Control Unit
  • Woodward MicroNet TMR 5009 Digital Control System: Authoritative Guide to Hardware Installation and Configuration
  • Woodward MicroNet ™ Analysis and Application of Simplex and Plus Digital Control Systems
  • WOODWARD MSLC-2XT™ Master Synchronizer and Load Control
  • Woodward DSLC Digital Synchronizer and Load Controller: Installation, Operation, and Troubleshooting Guide
  • WOODWARD DSLC-2 Digital Synchronizer and Load Control
  • From Beginner to Proficient: Woodward easyYgen-3000 Controller Interface Configuration, CANopen, J1939 and Modbus Communication Practical Guide
  • WOODWARD easYgen-3000 Series (Package P1) Genset Control
  • WOODWARD ® ProTech‐SX Safety System with Integrated Overspeed Protection
  • Woodward ProTech SX Simplex System: Turbine Single Channel Safety Protection System
  • Woodward QuickTrip Electro Hydraulic Trip Module Components: High Reliability Turbine Safe Shutdown Solution
  • WOODWARD QuickTrip Electro-Hydraulic Trip Block Assembly
  • WOODWARD VariStroke Hydraulic Power Cylinder (VHPC)
  • WOODWARD VariStroke GI single acting electro-hydraulic actuator: a reliable solution for turbine control
  • Woodward VariStroke DX hydraulic servo dual redundant sled
  • Woodward VariStroke-I electro-hydraulic actuator: an innovative solution for steam turbine valve control
  • WOODWARD MicroNet TMR ® OpView of 5009 Digital Control System ™ Interface Operation Manual
  • WOODWARD 5009XT Fault-Tolerant Control
  • Woodward PG-PL Hydraulic Governor: Reliable and Accurate Engine and Turbine Speed Control Solution
  • WOODWARD 2301A Speed Control Controller: A Classic and Reliable Engine and Turbine Speed Control Solution
  • XP POWER VFR05 Series 5W Convertible Plug AC-DC Adapter
  • XP POWER VFL05 Series 5W Wall Mounted AC-DC Power Adapter
  • XP POWER AQM200 Series 200W Natural Cooling Medical Grade AC-DC External Power Supply
  • XP POWER CB Series 1W Natural Cooling Micro High Voltage DC-HVDC Converter
  • XP POWER CDX Series 1500W Dual Frequency RF Power Supply
  • XP POWER RDF25 Series 5W Bottom Cooling DC-DC Converter
  • XP POWER ITX Series 6W DC-DC Converter: A Concise and Efficient Solution
  • XP Power Technical Guide: In Depth Analysis of AC/DC Conversion, System Topology, and High Reliability Design
  • XP POWER C Series Micro Stabilized High Voltage DC-DC Converter
  • XP POWER EHL05 Series 5W AC-DC Power Supply: A Wide Input Solution Designed for 480VAC Systems
  • XP Power: The world's leading expert in power conversion and its full range of solutions
  • XP POWER HDA1500 Series 1.5kW High Power AC-DC Power Supply
  • XP POWER SMP350 Series Fan Cooling 350W AC-DC Power Supply
  • XP POWER MP Series 300-2400 Watts AC-DC Power Supply
  • How to install the YAMAHA RCX40 four axis robot controller?
  • HIMA HIMax X-AO 16 01 Analog Output Module: SIL 3 Safety Certification and Key Technical Features
  • HIMA HIMax ® System Manual is applicable to safety related control systems
  • Hirschmann Industrial Ethernet Switch
  • YASKAWA A1000 series AC frequency converter
  • HIRSCHMANN MACH1040 family Full Gigabit Industrial Ethernet Ruggedized Switch
  • How to operate the Hirschmann MICE series media module and expansion module?
  • How to install Hirschmann MS20/MS30 series industrial Ethernet switches?
  • Hirschmann GUI Graphical User Interface Industrial ETHERNET (Gigabit-)Switch RS20/RS30/RS40, MS20/MS30
  • HIRSCHMANN MICE series modular industrial communication equipment
  • TOSHIBA TOSBERT VF-AS3 series
  • TOSHIBA MG08-D SERIES ENTERPRISE CAPACITY HDD
  • Triconex Tricon™ v9–v11 Systems Planning and Installation Guide
  • XYCOM XVME-100 memory module
  • ABB Ability™ Symphony® Plus MR Series
  • BENTLY 3500/15 AC and DC Power Supplies
  • HITACHI S10VE Programmable Controller
  • ABB SYNCHROTACT ® 5 synchronous devices
  • YASKAWA SGMCS series direct drive servo motor
  • YASKAWA GA700 series AC frequency converter
  • YASKAWA ∑ - V series AC servo drive
  • YASKAWA S-7 series linear servo
  • YASKAWA GA500 series AC micro frequency converter
  • YASKAWA 1000 series frequency converter
  • YASKAWA 120 Series I/O Modules
  • YASKAWA MEMOCON-SC 2000 series reversible counter module
  • YASKAWA Machine Controller MP2000 Series
  • Yaskawa VARISPEED-626M5 frequency converter
  • Yaskawa CP-9200SH Controller
  • WESTINGHOUSE eVinci ™ Micro reactor
  • WESTINGHOUSE HC series molded case circuit breaker
  • WESTINGHOUSE MAX-VH ™/ MAX-VHP ™ Series vertical hollow shaft induction motor
  • WESTINGHOUSE Alpha Plus Series Low Voltage Distribution System
  • WESTINGHOUSE Three Phase Induction Motors
  • WESTINGHOUSE iGen5000 Digital Inverter Generator
  • WESTINGHOUSE E510 series compact AC frequency converter (VFD)
  • WESTINGHOUSE E-Series MCCB (Molded Case Circuit Breaker)
  • WESTINGHOUSE Transformer Product Line
  • Emerson Ovation OCR1100 Controller
  • BENDER Isolated Power Panels
  • Bender LifeGuard® LG2-Series Protection Panels
  • Bender LINETRAXX ® CTAC series AC measurement current transformer
  • Bender GPM series grounding power module
  • BENDER LINETRAXX® CTUB100 series AC/DC sensitive measuring current transformers (type B)
  • Bender LifeGuard ® LG2 series protective panel
  • BENDER ISOMETER ® Iso685 series
  • BENDER Greenlee 555C Electric Pipe Bending Machine
  • BENDER ISOMETER® iso685(W)-D/-S Insulation Monitoring Device
  • BENDER LINETRAXX ® VMD420 Three phase Voltage Frequency Monitor
  • BENDING 77 Series Electric Bender with Single Shoe Groups
  • BENDER EDS3090 series portable grounding fault location system
  • BENDER ISOSCAN ® EDS460/490-EDS461/491 series
  • Bender EDS3090/-91/-92/-96 series
  • SMC IRV10/20 series vacuum regulator
  • BMCM AMS42/84 5B amplifier system
  • ABB AFS series switches
  • NI VXIpc-870B Series Embedded Pentium III VXIbus Controllers
  • BENDER ISOMETER ® IRDH265/365 series Insulation Monitoring Equipment
  • BENDER ISOMETER ® IRDH375 series Insulation Monitoring Equipment
  • BENDER WR70x175S (P)... WR200x500S (P) rectangular measuring current transformer