Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • ABB PHARPSPEP11013 Power Entry Panel Single Chassis
    ❤ Add to collection
  • ABB PHARPSPEP11013 Power Entry Panel Single Chassis

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    PHARPSPEP11013 Power Entry Panel Single Chassis
    • ¥4366.00
      ¥12041.00
      ¥4366.00
      ¥4366.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.000KG
    • Quantity:
    • (Inventory: 2)
Description
PHARPSPEP11013 Power Entry Panel Single Chassis

ABB PHARPSPEP11013 Power Entry Panel Single Chassis

Basic Information

ABB PHARPSPEP11013 Power Entry Panel Single Chassis is a single chassis power entry panel from ABB. It is mainly used to connect and distribute external power to the internal modules of various electrical devices or systems, and is an important component of power management in electrical systems.

Functionality

Power access and distribution

Provides a convenient power access point that can accommodate many common power types, including alternating current (AC) and direct current (DC) power. For example, it can access 110V AC or 220V AC mains power, and can also handle a specific range of DC power, such as 24V DC or 48V DC. Through internal circuit design, the accessed power is reasonably distributed to each output branch to provide a stable power supply to different equipment modules, ensuring that each module receives the appropriate operating voltage and current.

Protection Mechanisms

A variety of power protection functions are integrated. Overcurrent protection is one of its important functions. When the current in an output branch exceeds the preset safety threshold, the power access panel is able to quickly cut off the power supply to that branch, preventing the equipment from being damaged by excessive current. For example, in the case of connecting multiple electronic devices, if one of the devices has a short-circuit fault, the over-current protection function will start immediately to avoid the fault affecting other normal devices. It also has an over-voltage protection function, which protects downstream equipment from damage caused by high voltage when the input power supply voltage is abnormally high.

Filtering Function

The built-in filter circuit is used to filter the input power supply. In the actual electrical environment, the power supply is often mixed with various interference signals, such as high-frequency noise. The filter circuit can effectively remove these interfering signals and output a relatively pure power supply. This is very important for electronic equipment with high power quality requirements, such as precision instruments, communication equipment, etc., to help improve the stability and reliability of the equipment.

Technical Parameters

Input parameters

Voltage range: a wide range of input voltage adaptation, the specific range depends on the product design. Generally speaking, for AC input, it may cover the range of 100V - 240V AC; for DC input, it may include the range of 18V - 60V DC, in order to adapt to the grid voltage of different regions and different types of power supply access requirements.

Maximum Input Current: There is a certain rated input current limit, this parameter determines the maximum input current it can withstand, usually between a few amperes to tens of amperes, for example, the rated input current may be 10A or 20A, which also limits the total power of the load it can access.

Output Parameters

Number of output branches: There are usually multiple output branches, usually around 3 - 8 in number, which can provide independent power outputs for different devices or modules.

Output Voltage Type and Accuracy: It is capable of outputting a variety of voltage types, such as common DC voltages like 5V DC, 12V DC, 24V DC, and AC voltages like 110V AC or 220V AC. The output voltage has certain accuracy requirements, for DC voltage, the accuracy may be between ±3% - ±5%, and for AC voltage, the accuracy may be between ±5% - ±7%, in order to ensure that a stable and accurate power supply is provided to the equipment.

Electrical Isolation Performance

Good electrical isolation is provided between inputs and outputs and between different output branches. The isolation voltage is generally between 1000V - 2500V. This isolation can effectively prevent electrical faults from propagating between different circuits and ensure the safe operation of the equipment.

Application Areas

Industrial control equipment

In industrial automation control systems, they are used to provide power access and distribution for various controllers (e.g. PLCs), sensors and actuators. For example, in an automated production line, it can provide stable power for temperature sensors, pressure sensors, motor drives and other equipment to ensure the normal operation of the production line.

Electronic Instruments and Equipment

It is widely used in various electronic instruments, such as oscilloscopes and signal generators. These instruments require high power quality, this power access panel provides pure and stable power supply for the instruments through its filtering and protection functions to ensure the accuracy and reliability of the instruments.

Communication and network equipment

It is used to provide power management for switches, routers, servers and other equipments in places where communication and network equipments are concentrated, such as communication base stations and server cabinets. It can adapt to the power demand of communication equipment, and at the same time ensure the safe operation of the equipment in the complex power environment through the protection function.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice