  • GE SR745-W2-P1-G1-HI-A-L-R Transformer Management Relay
    ❤ Add to collection
  • GE SR745-W2-P1-G1-HI-A-L-R Transformer Management Relay

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    For common faults and abnormal working conditions of transformers, multiple protection logics are built-in to ensure quick action in case of faults and minimize equipment damage:

    -Overcurrent protection: including timed overcurrent and inverse time overcurrent protection, which can intelligently adjust the action time according to the degree of current abnormality, adapt to different fault scenarios, and effectively deal with problems such as short circuits and overloads.

    -Differential protection: By comparing the current difference between the high and low voltage sides of the transformer, it accurately identifies internal short-circuit faults, has fast action speed and high sensitivity, and is the core protection method for internal faults in transformers.


    • ¥25643.00
      ¥25463.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:1.570KG
    • Quantity:
    • (Inventory: 99999)
Description

For common faults and abnormal working conditions of transformers, multiple protection logics are built-in to ensure quick action in case of faults and minimize equipment damage:

-Overcurrent protection: including timed overcurrent and inverse time overcurrent protection, which can intelligently adjust the action time according to the degree of current abnormality, adapt to different fault scenarios, and effectively deal with problems such as short circuits and overloads.

-Differential protection: By comparing the current difference between the high and low voltage sides of the transformer, it accurately identifies internal short-circuit faults, has fast action speed and high sensitivity, and is the core protection method for internal faults in transformers.





GE SR745-W2-P1-G1-HI-A-L-R Transformer Management Relay

Core function: Multi dimensional protection of transformer operation safety

This relay is centered around "precise protection and comprehensive monitoring" and has the following key functions, covering the full scenario requirements of transformer operation:

1. Comprehensive protection function

For common faults and abnormal working conditions of transformers, multiple protection logics are built-in to ensure quick action in case of faults and minimize equipment damage:

-Overcurrent protection: including timed overcurrent and inverse time overcurrent protection, which can intelligently adjust the action time according to the degree of current abnormality, adapt to different fault scenarios, and effectively deal with problems such as short circuits and overloads.

-Differential protection: By comparing the current difference between the high and low voltage sides of the transformer, it accurately identifies internal short-circuit faults, has fast action speed and high sensitivity, and is the core protection method for internal faults in transformers.

-Voltage protection: covering overvoltage, low voltage, and voltage imbalance protection, preventing insulation aging, iron core saturation, and other issues caused by abnormal voltage, ensuring equipment insulation performance.

-Temperature protection: Supports linkage with transformer oil temperature and winding temperature sensors to monitor temperature changes in real time. When the temperature exceeds the threshold, an alarm or trip is triggered to avoid overheating damage.

-Non electrical protection: It can be connected to non electrical signals such as gas relays and pressure relief valves to quickly respond to faults such as abnormal oil level and gas leakage in transformers, making up for the shortcomings of electrical protection.

2. Accurate measurement and monitoring

Adopting high-precision sensing and measurement technology, real-time collection of transformer operating parameters, providing comprehensive status data for operation and maintenance personnel:

-Electrical parameters: Accurately measure three-phase current, voltage, power factor, active power, reactive power, apparent power, and accumulated electrical energy on the high and low voltage sides, with a measurement accuracy of 0.2 level, meeting the measurement and monitoring needs of the power system.

-Temperature parameters: Supports the connection of multiple Pt100 platinum resistance temperature sensors, while monitoring the top oil temperature, bottom oil temperature, and winding hotspot temperature of the transformer. The temperature measurement range is -50 ℃~200 ℃, with an accuracy of ± 1 ℃.

-Status monitoring: Real time monitoring of the working status of the relay itself (such as power supply and module failures) and the status of transformer auxiliary equipment (such as cooling fans and oil pump operation), and timely feedback of abnormal information.

3. Flexible control and operation

Having rich control interfaces and operation modes, supporting local and remote control, and adapting to different operation and maintenance scenarios:

-Local operation: equipped with high-definition LCD display screen and buttons, supporting parameter setting, protection setting modification, manual opening and closing control, etc. The interface is simple and intuitive, and the operation logic is clear.

-Remote control: Receive backend system instructions through communication interfaces to achieve remote fixed value issuance, control command execution, data summoning, and other functions, supporting remote operation and maintenance of unmanned substations.

-Auxiliary control: It can automatically control the start and stop of the cooling system (such as fans and oil pumps) according to the operating status of the transformer, achieve temperature closed-loop control, and optimize equipment energy consumption.

4. Reliable communication and data exchange

Support multiple communication protocols and interfaces to ensure seamless integration with the backend monitoring system of the power system, achieving efficient data transmission and sharing:

-Communication Protocol: Compatible with mainstream power communication protocols such as IEC 61850, Modbus RTU/TCP, IEC 60870-5-103, and can flexibly adapt to monitoring systems from different manufacturers.

-Communication interface: equipped with 1 Ethernet interface (RJ45), 2 RS485 serial interfaces, supporting fiber optic communication module expansion, communication speed up to 100Mbps, stable and reliable data transmission.

-Data upload: Real time upload of measurement data, status information, fault recording data, etc., supporting SOE (sequence of events recording) of fault events, with a time resolution of 1ms, providing accurate basis for fault analysis.


Technical parameters: Hardware support for stable operation

The core technical parameters of this relay have been rigorously optimized to ensure stability and reliability in complex power environments. The key parameters are shown in the table below:

parameter category

specific parameters

Instructions

Power parameters

DC: 24V/48V/110V/220V; Communication: 110V/220V

Wide voltage input range, suitable for different power system power supply configurations

input current

Rated current: 5A or 1A

Support the connection of conventional current transformers, which can be adapted through parameter settings

input voltage

Rated voltage: 100V (line voltage)/57.7V (phase voltage)

Adapt to the secondary output of voltage transformers in high-voltage systems

Protection setting range

Overcurrent: 0.5~20Ie; Overvoltage: 1.05~1.5Un; Low Voltage: 0.5~0.95Un

Continuous adjustable constant value, suitable for different capacity transformer requirements

Action Time

Differential protection: ≤ 20ms; overcurrent protection: 0.01~30s

Quickly respond to faults and reduce their duration

working environment

Temperature: -25 ℃~70 ℃; Humidity: 5%~95% (no condensation); Altitude: ≤ 2000m

Adapt to complex outdoor environments such as high altitude and high temperature differences

mechanical properties

Anti vibration: 5-150Hz, acceleration 2g; anti impact: 10g (11ms)

Meet the mechanical environment requirements for power equipment transportation and on-site operation


Product advantage: Adapt to the upgrading needs of power systems

Compared to traditional transformer protection devices, GE SR745-W2-P1-G1-HI-A-L-R relay has significant advantages and is more in line with the intelligent and efficient operation and maintenance needs of modern power systems

1. Integrated design, simplifying system architecture: integrating multiple functions such as protection, measurement, monitoring, and communication, replacing traditional combination applications of multiple devices, reducing equipment footprint, lowering system wiring complexity, and improving operational reliability.

2. Coexistence of high precision and high reliability: Adopting GE patented signal processing algorithms and industrial grade hardware solutions, the measurement accuracy and protection action reliability have reached the international leading level. After rigorous electromagnetic compatibility testing (IEC 61000-4 series), it has strong anti-interference ability.

3. Intelligent operation and maintenance, reducing labor costs: supporting functions such as fault recording, event recording, and status diagnosis, it can automatically analyze equipment operation trends, warn potential faults in advance, reduce manual inspection frequency, and lower operation and maintenance costs.

4. Flexible expansion and adaptation to diverse needs: Reserve multiple expansion interfaces to increase the number of temperature sensor connections, communication module types, etc. according to actual needs, adapt to transformers of different capacities and application scenarios, and have good compatibility and scalability.


Application scenario: Covering the entire industry's electricity demand

With its comprehensive functionality and reliable performance, this relay is widely used in various power system scenarios, including:

-Power generation system: Main transformer protection for thermal power plants, hydropower plants, and new energy power stations to ensure stable connection between power generation equipment and the power grid.

-Power transmission and transformation system: protection of main and connecting transformers in 110kV~500kV substations to ensure the safe operation of the transmission network.

-Industrial enterprises: Protection of plant transformers for large industrial users such as steel, chemical, and metallurgical industries to avoid economic losses caused by power outages during production processes.

-Municipal facilities: protection of distribution transformers for urban rail transit, data centers, and high-rise buildings to ensure power supply for people's livelihoods and critical facilities.


Installation and maintenance: convenient and efficient full cycle support

This relay adopts standardized design, with a simple installation and maintenance process, reducing the difficulty of on-site construction and operation:

-Installation method: Supports both panel installation and rail installation, suitable for different cabinet structures. The wiring terminals adopt a plug-in design for easy on-site wiring and debugging.

-Maintenance guarantee: It has a complete self diagnostic function, which can monitor its hardware status in real time. When a fault occurs, the fault location is indicated through the alarm light and display screen, making it easy to quickly locate and repair; GE provides professional technical support and after-sales service to ensure stable operation of equipment throughout its entire lifecycle.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ADLINK cPCI-3720: 3U CompactPCI Low Power Pentium III CPU Module
  • ADLINK NuPRO-E47: PICMG 1.3 13th Generation Core Industrial SHB
  • ADLINK NuPRO-E43: PICMG 1.3 Core 7th Generation Industrial SHB
  • ADLINK NuPRO-780 PICMG Bus Core CPU Card
  • ADLINK cPCI-6965 6U CompactPCI Core Dual Core Single Board Computer
  • ADLINK USB/LPCI/LPCIe-3488A GPIB Interface Card Selection and Application Guide
  • Rittal SK 3241.700 Blue e+Cabinet Fan Filter Unit
  • ADLINK CPCI-8168 8-Axis Motion Control Card and HSL Network Integration Solution
  • ADLINK PCIe-PXIe-8638 High Speed PXIe Bus Expansion Scheme
  • ADLINK PCIe GIE7x Poe+Frame Grabber Hardware and Power Management Detailed Explanation
  • ADLINK PCIe-7396 Digital I/O Card Deployment Guide
  • ADLINK PCI-8164 Advanced Motion Control Card Deployment Guide
  • ADLINK PCI-8154 Motion Control Card Deployment Guide
  • ADLINK PCI-8134 Motion Control Card Deployment Guide
  • ADLINK NuPRO-E42 Industrial Control Motherboard Deployment Guide
  • ADLINK MXC-6600 Embedded Platform Deployment Guide
  • ADLINK MXC-6000 Industrial Control Computer Deployment and Optimization Guide
  • ADLINK MXC-2300 Embedded System Deployment Guide
  • ADLINK MCM-204 Edge DAQ Deployment Configuration Guide
  • ADLINK MCM-100/102 Deployment Calibration Guide
  • Deployment and Performance Optimization of ADLINK MXC-6400 Industrial Control Computer
  • Selection and Deployment of ADLINK Matrix Series Industrial Control Computers
  • российские промышленные новые машины.Наш отдел дебютировал в 2026 году в России Международная промышленная ярмарка INNOPROM
  • Deeply cultivating the Eurasian industrial market, linking new industrial opportunities between China and Russia
  • Deployment and troubleshooting of ADLINK GIE64+PoE acquisition card
  • Honeywell UMS Security System Troubleshooting Guide
  • Honeywell Expert Series C I/O Troubleshooting Guide
  • ADLINK EOS-1200 Vision System Deployment and Troubleshooting
  • ADLINK DLAP-5200 series AI engine deployment and optimization
  • ADLINK DLAP-4000 Deployment and BIOS Optimization
  • ADLINK Matrix MXC-2000 Deployment and Troubleshooting
  • ADLINK DAQe-2000 series acquisition card calibration and synchronization
  • ADLINK cPCI-6520 Core i7 Processor Blade Engineering Application Guide
  • ADLINK CM1-86DX3 PC/104 Embedded Single Board Computer Engineering Application Guide
  • Honeywell DC1000 Series PID Temperature Controller Engineering Application Guide
  • ALSTOM MiCOM C264 Substation Controller Engineering Application Guide
  • EMERSON AMS 2140 Practical Guide for On site Dynamic Balance and Vibration Analysis
  • ADLINK NuPRO-E320 motherboard deployment and tuning guide
  • ADLINK NuPRO-800 Dual PIII Industrial SBC Maintenance and Upgrade Guide
  • ADLINK NuPRO-598 SBC Maintenance Practical Guide
  • ADLINK MXC-6300 Fanless Embedded Industrial Control Computer Deployment Guide
  • ADLINK Express-BASE7 Carrier Board Quick Deployment and Debugging Guide
  • ADLINK DLAP-211 Edge AI Platform Selection and Deployment Guide
  • ADLINK 7230 Series Isolation DIO Card Selection and Engineering Application Guide
  • ADLINK cPCI-6965 SBC Embedded Installation and BIOS Tuning Guide
  • ADLINK 7200 Series High Speed DIO Card Practical Guide
  • ADLINK DLAP Series Edge AI Acceleration Platform Selection and Deployment Practical Guide
  • DEIF TCM-2 thyristor control module: Wind power cut in control engineering guide
  • DEIF MVR-200 Medium Voltage Relay: Installation and Wiring Engineering Guide
  • DEIF MDR-2 Differential Relay: Engineering Guide for Generator Differential Protection
  • DEIF Delomatic 3 AOM: Engineering Guide for Analog Output Modules
  • DEIF AGI 400 Graphic Interface: Ship and Industrial HMI Solution
  • DEIF BRW-1 Marine Instruments: Installation and Calibration Guide for Offshore Bridge Indicators
  • DEIF AGC 200 Controller: Quick Deployment and Configuration Guide for Generator Sets
  • DEIF AGC-2 Controller: The Ultimate Guide to Automatic Control and Protection of Generator Sets
  • ABB SPA-ZC400 Gateway: REM54x Access to IEC 61850 Ultimate Engineering Guide
  • ABB REM 543/545 Terminal
  • Modular Architecture Analysis of DEIF PPU 300 Ship Generator Controller
  • DEIF DM-4 Marine&Offshore Ship Power Management System
  • Detailed Explanation of DEIF Delomatic Generator Control System Architecture
  • DEIF AGC-4 Mk II Generator Controller Depth Configuration Guide
  • DEIF AGC-4 Generator Controller Configuration and Debugging Guide
  • DEIF PPM Power Management System Operation and Troubleshooting
  • Installation and wiring of DEIF Multi line 2
  • Practical configuration and maintenance of Beckwith M-6280 capacitor bank controller
  • Beckwith M-3311 Transformer Protection Relay Setting and Engineering Application
  • Beckwith M-3311A Transformer Protection Relay Configuration and Optimization Guide
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit
  • Installation and I/O configuration of DEIF PPM-3 power management module
  • Beckwith M-3520 Interconnection Protection Relay
  • Beckwith M-3430 Generator Protection Relay
  • Beckwith M-2293B adapter panel replacement GE regulator guide
  • Selection and Networking of Beckwith M-2001C Digital Voltage Regulating Controller
  • Beckwith M-2001B Digital Voltage Regulating Controller
  • Beckwith M-0388/M-0389 Synchronous Inspection Relay Application Guide
  • Beckwith M-0193B Synchronizer Debugging and System Integration Guide
  • Beckwith M-0115A Parallel Balance Module Debugging Guide
  • Beckwith M-0067E On Load Voltage Regulating Controller Selection and Debugging Guide
  • Debugging and Fault Handling of Beckwith M-4272 Digital Busbar Conversion System
  • Beckwith M-3311A Transformer Protection Relay Debugging Guide
  • Beckwith M-3425A Generator Protection Relay Debugging Guide
  • Setting and troubleshooting of Basler BE1-27/59 voltage relay
  • Debugging and troubleshooting of Basler AVC63-12/AVC125-10 voltage regulator
  • Basler L301kc Line Array Camera Technology and Troubleshooting
  • Selection and Debugging of Basler CBS 212A Current Boosting System
  • Selection and commissioning of Basler BE3-25 synchronous inspection relay
  • Basler BE1-32R/32O/U Direction Power Relay Setting and Testing Guide
  • Basler PRS 250 Synchronous Relay Maintenance and Replacement Guide
  • Basler piA2400-17gc Industrial Camera Replacement and Optimization Guide
  • Basler BE1-11g Generator Protection System
  • Basler VR63-4C/UL Voltage Regulator
  • Basler BE1-DFPR feeder protection relay
  • Basler CBS 310/320 Current Boosting System
  • Basler UFOV 250A/260A protection module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F Regulator
  • Basler DECS-400 excitation system
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection
  • Basler SSR Static Voltage Regulator: A Complete Guide to Debugging and Troubleshooting
  • Basler SR4A/SR8A Voltage Regulator: Detailed Debugging and Troubleshooting Explanation
  • Basler BE2000E Voltage Regulator: Replacement and Application Details
  • Basler DECS-2100 Excitation System: Modular Upgrade and Engineering Application
  • Basler BE1-851 Overcurrent Protection System: A Complete Guide to Professional Debugging and Troubleshooting
  • Basler APR 63-5 Voltage Regulator: Professional Debugging and Troubleshooting Guide for Industrial Generator Excitation Systems
  • Basler BE1-FLEX Protection System: A Complete Guide to Professional Installation, Configuration, and Troubleshooting
  • Debugging and Testing of Basler BE1-700 Relay
  • Basler BE1-87B busbar differential setting test
  • Basler BE1-40Q demagnetization relay setting test
  • Basler BE1-60 Voltage Balance Relay Setting Test
  • Basler BE1-47N Relay Field Setting and Testing Guide
  • Basler BE1-81O/U Frequency Relay: On site Debugging and Protection Configuration Guide
  • Basler BE1-11f Feedline Protection System Debugging and Troubleshooting Guide
  • Basler DECS-250 Excitation System: Installation, Configuration, and Troubleshooting Practice Guide
  • Basler DECS-100 Digital Excitation System Debugging Guide
  • Application Guide for Basler BE1-BPR Circuit Breaker Protection Relay
  • Basler BE1-50/51B-255 Replacement CO Relay Guide
  • Basler BE1-25 synchronous inspection relay principle and testing
  • Basler BE1-51 Time Overcurrent Relay Debugging Guide
  • Practical Guide to Basler DECS-300 Digital Excitation System
  • Mitsubishi FX Series PLC Data Communication Practical Manual
  • Selection of Hirschmann cSCALE S6/C8 Mobile Safety Controller
  • Hirschmann OZD Profi G12D repeater explosion-proof installation configuration
  • Hirschmann OCTOPUS OS20/24 Switch Installation Power Supply