  • GE SR745-W2-P1-G1-HI-A-L-R Transformer Management Relay
    ❤ Add to collection
  • GE SR745-W2-P1-G1-HI-A-L-R Transformer Management Relay

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    For common faults and abnormal working conditions of transformers, multiple protection logics are built-in to ensure quick action in case of faults and minimize equipment damage:

    -Overcurrent protection: including timed overcurrent and inverse time overcurrent protection, which can intelligently adjust the action time according to the degree of current abnormality, adapt to different fault scenarios, and effectively deal with problems such as short circuits and overloads.

    -Differential protection: By comparing the current difference between the high and low voltage sides of the transformer, it accurately identifies internal short-circuit faults, has fast action speed and high sensitivity, and is the core protection method for internal faults in transformers.


    • ¥25643.00
      ¥25463.00
      ¥25643.00
      ¥25643.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:1.570KG
    • Quantity:
    • (Inventory: 99999)
Description

For common faults and abnormal working conditions of transformers, multiple protection logics are built-in to ensure quick action in case of faults and minimize equipment damage:

-Overcurrent protection: including timed overcurrent and inverse time overcurrent protection, which can intelligently adjust the action time according to the degree of current abnormality, adapt to different fault scenarios, and effectively deal with problems such as short circuits and overloads.

-Differential protection: By comparing the current difference between the high and low voltage sides of the transformer, it accurately identifies internal short-circuit faults, has fast action speed and high sensitivity, and is the core protection method for internal faults in transformers.





GE SR745-W2-P1-G1-HI-A-L-R Transformer Management Relay

Core function: Multi dimensional protection of transformer operation safety

This relay is centered around "precise protection and comprehensive monitoring" and has the following key functions, covering the full scenario requirements of transformer operation:

1. Comprehensive protection function

For common faults and abnormal working conditions of transformers, multiple protection logics are built-in to ensure quick action in case of faults and minimize equipment damage:

-Overcurrent protection: including timed overcurrent and inverse time overcurrent protection, which can intelligently adjust the action time according to the degree of current abnormality, adapt to different fault scenarios, and effectively deal with problems such as short circuits and overloads.

-Differential protection: By comparing the current difference between the high and low voltage sides of the transformer, it accurately identifies internal short-circuit faults, has fast action speed and high sensitivity, and is the core protection method for internal faults in transformers.

-Voltage protection: covering overvoltage, low voltage, and voltage imbalance protection, preventing insulation aging, iron core saturation, and other issues caused by abnormal voltage, ensuring equipment insulation performance.

-Temperature protection: Supports linkage with transformer oil temperature and winding temperature sensors to monitor temperature changes in real time. When the temperature exceeds the threshold, an alarm or trip is triggered to avoid overheating damage.

-Non electrical protection: It can be connected to non electrical signals such as gas relays and pressure relief valves to quickly respond to faults such as abnormal oil level and gas leakage in transformers, making up for the shortcomings of electrical protection.

2. Accurate measurement and monitoring

Adopting high-precision sensing and measurement technology, real-time collection of transformer operating parameters, providing comprehensive status data for operation and maintenance personnel:

-Electrical parameters: Accurately measure three-phase current, voltage, power factor, active power, reactive power, apparent power, and accumulated electrical energy on the high and low voltage sides, with a measurement accuracy of 0.2 level, meeting the measurement and monitoring needs of the power system.

-Temperature parameters: Supports the connection of multiple Pt100 platinum resistance temperature sensors, while monitoring the top oil temperature, bottom oil temperature, and winding hotspot temperature of the transformer. The temperature measurement range is -50 ℃~200 ℃, with an accuracy of ± 1 ℃.

-Status monitoring: Real time monitoring of the working status of the relay itself (such as power supply and module failures) and the status of transformer auxiliary equipment (such as cooling fans and oil pump operation), and timely feedback of abnormal information.

3. Flexible control and operation

Having rich control interfaces and operation modes, supporting local and remote control, and adapting to different operation and maintenance scenarios:

-Local operation: equipped with high-definition LCD display screen and buttons, supporting parameter setting, protection setting modification, manual opening and closing control, etc. The interface is simple and intuitive, and the operation logic is clear.

-Remote control: Receive backend system instructions through communication interfaces to achieve remote fixed value issuance, control command execution, data summoning, and other functions, supporting remote operation and maintenance of unmanned substations.

-Auxiliary control: It can automatically control the start and stop of the cooling system (such as fans and oil pumps) according to the operating status of the transformer, achieve temperature closed-loop control, and optimize equipment energy consumption.

4. Reliable communication and data exchange

Support multiple communication protocols and interfaces to ensure seamless integration with the backend monitoring system of the power system, achieving efficient data transmission and sharing:

-Communication Protocol: Compatible with mainstream power communication protocols such as IEC 61850, Modbus RTU/TCP, IEC 60870-5-103, and can flexibly adapt to monitoring systems from different manufacturers.

-Communication interface: equipped with 1 Ethernet interface (RJ45), 2 RS485 serial interfaces, supporting fiber optic communication module expansion, communication speed up to 100Mbps, stable and reliable data transmission.

-Data upload: Real time upload of measurement data, status information, fault recording data, etc., supporting SOE (sequence of events recording) of fault events, with a time resolution of 1ms, providing accurate basis for fault analysis.


Technical parameters: Hardware support for stable operation

The core technical parameters of this relay have been rigorously optimized to ensure stability and reliability in complex power environments. The key parameters are shown in the table below:

parameter category

specific parameters

Instructions

Power parameters

DC: 24V/48V/110V/220V; Communication: 110V/220V

Wide voltage input range, suitable for different power system power supply configurations

input current

Rated current: 5A or 1A

Support the connection of conventional current transformers, which can be adapted through parameter settings

input voltage

Rated voltage: 100V (line voltage)/57.7V (phase voltage)

Adapt to the secondary output of voltage transformers in high-voltage systems

Protection setting range

Overcurrent: 0.5~20Ie; Overvoltage: 1.05~1.5Un; Low Voltage: 0.5~0.95Un

Continuous adjustable constant value, suitable for different capacity transformer requirements

Action Time

Differential protection: ≤ 20ms; overcurrent protection: 0.01~30s

Quickly respond to faults and reduce their duration

working environment

Temperature: -25 ℃~70 ℃; Humidity: 5%~95% (no condensation); Altitude: ≤ 2000m

Adapt to complex outdoor environments such as high altitude and high temperature differences

mechanical properties

Anti vibration: 5-150Hz, acceleration 2g; anti impact: 10g (11ms)

Meet the mechanical environment requirements for power equipment transportation and on-site operation


Product advantage: Adapt to the upgrading needs of power systems

Compared to traditional transformer protection devices, GE SR745-W2-P1-G1-HI-A-L-R relay has significant advantages and is more in line with the intelligent and efficient operation and maintenance needs of modern power systems

1. Integrated design, simplifying system architecture: integrating multiple functions such as protection, measurement, monitoring, and communication, replacing traditional combination applications of multiple devices, reducing equipment footprint, lowering system wiring complexity, and improving operational reliability.

2. Coexistence of high precision and high reliability: Adopting GE patented signal processing algorithms and industrial grade hardware solutions, the measurement accuracy and protection action reliability have reached the international leading level. After rigorous electromagnetic compatibility testing (IEC 61000-4 series), it has strong anti-interference ability.

3. Intelligent operation and maintenance, reducing labor costs: supporting functions such as fault recording, event recording, and status diagnosis, it can automatically analyze equipment operation trends, warn potential faults in advance, reduce manual inspection frequency, and lower operation and maintenance costs.

4. Flexible expansion and adaptation to diverse needs: Reserve multiple expansion interfaces to increase the number of temperature sensor connections, communication module types, etc. according to actual needs, adapt to transformers of different capacities and application scenarios, and have good compatibility and scalability.


Application scenario: Covering the entire industry's electricity demand

With its comprehensive functionality and reliable performance, this relay is widely used in various power system scenarios, including:

-Power generation system: Main transformer protection for thermal power plants, hydropower plants, and new energy power stations to ensure stable connection between power generation equipment and the power grid.

-Power transmission and transformation system: protection of main and connecting transformers in 110kV~500kV substations to ensure the safe operation of the transmission network.

-Industrial enterprises: Protection of plant transformers for large industrial users such as steel, chemical, and metallurgical industries to avoid economic losses caused by power outages during production processes.

-Municipal facilities: protection of distribution transformers for urban rail transit, data centers, and high-rise buildings to ensure power supply for people's livelihoods and critical facilities.


Installation and maintenance: convenient and efficient full cycle support

This relay adopts standardized design, with a simple installation and maintenance process, reducing the difficulty of on-site construction and operation:

-Installation method: Supports both panel installation and rail installation, suitable for different cabinet structures. The wiring terminals adopt a plug-in design for easy on-site wiring and debugging.

-Maintenance guarantee: It has a complete self diagnostic function, which can monitor its hardware status in real time. When a fault occurs, the fault location is indicated through the alarm light and display screen, making it easy to quickly locate and repair; GE provides professional technical support and after-sales service to ensure stable operation of equipment throughout its entire lifecycle.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Mitsubishi Electric GT23 Series HMI Maintenance Guide
  • Mitsubishi GT27 HMI Application Guide
  • Siemens SIMATIC ET 200M Selection
  • Lenze 8200 Vector Selection
  • Troubleshooting of Siemens MASTER DRIVES VC
  • FANUC I/O Unit A Maintenance Manual
  • Allen Bradley PLC-5 Classic Controller Complete Guide
  • Maintenance of M&C SP2006-H/DIL Sampling Probe
  • Pro face connection to Mitsubishi DIASYS Netmation
  • OMRON SYSMAC C-series/CVM1/CV series analog I/O units
  • LTI ServoOne Replacement and Troubleshooting
  • OMRON C-series AD/DA module configuration
  • Siemens 840C 611D Module Replacement Guide
  • Diagnosis and maintenance of ABB ACS550 frequency converter fault codes
  • OMRON NX1P2 Hardware Debugging Guide
  • Fuji FRENIC Mini inverter troubleshooting
  • Braided Forissier Braided Copper Strip Selection Guide
  • Mecc Alte MC200 Controller Engineering Debugging and Troubleshooting
  • Schneider Square D 9036/9037/9038 Electromechanical Liquid Level Controller
  • Pilz PSS 4000 distributed safety control
  • Schneider TeSys GV5/GV6 Motor Circuit Breaker Operation and Protection Guide
  • Eaton Freedom NEMA Contactor Starter Complete Guide
  • OMRON D4SL-N/D4SL-NSK10-LK Safety Door Switch Comprehensive Guide
  • NI CompactRIO Embedded System
  • Emerson Ovation I/O Module Troubleshooting and Replacement Practical Guide
  • MITSUBISHI A-series PLC Troubleshooting Replacement
  • Automation Direct DL06 D0-06DD1 Replacement Guide
  • IFM CR2530 Intelligent Controller Guide
  • OMRON FH/FHV series visual sensor controller
  • Pilz PDP67 F4 code troubleshooting
  • Panasonic FP-X PLC Replacement and Troubleshooting
  • OMRON CK3W-AX Multi axis Control Selection
  • Debugging and maintenance of EPSON RC90/RC90-B controller
  • Nthytronic Group iRTUe I/O Expansion Module
  • Schneider ATV320 Inverter Installation and Debugging Guide
  • Eaton SPB Drawdown Switch Maintenance Guide
  • GFS EVO-SP dual fuel retrofit complete solution
  • OMRON CJ2 CPU Troubleshooting and Maintenance
  • Complete Guide to Lenze ECS Servo System
  • GE EX2100e Excitation System Complete Guide
  • OMRON G3PW Power Controller: Parameter Setting and Troubleshooting Guide
  • Key Points for Selection and Deployment of MITSUBISHI FX3GE PLC
  • Beckhoff EP23xx EtherCAT Box Selection Troubleshooting
  • MITSUBISHI MDS-B servo troubleshooting
  • TOYO valve pressure and temperature selection
  • SIEMENS SIMODRIVE 611 HR/HRS Replacement and Advanced Positioning Techniques
  • SIEMENS SINUMERIK 840C 611-D Startup and Troubleshooting Guide
  • FANUC Series 0i-F Maintenance and Troubleshooting
  • Troubleshooting Schneider Modicon TM3 Bus Expansion
  • Troubleshooting of R&S EPL1000
  • Baum ü llerb b maXX 5000 Safety Configuration and Troubleshooting Guide
  • Huichuan AM600 Motion Controller Malfunction and Replacement Guide
  • Allen Bradley Ultra3000 Servo Motor Replacement Guide
  • NEC NL8060BC26-17 LCD Module Maintenance and Replacement
  • ABB Pluto Safety PLC Maintenance and Troubleshooting
  • OMRON NE1A Safety Controller Troubleshooting and Replacement
  • Allen Bradley 2711P series PanelView Plus human-machine interface terminal
  • NI cFP-22xx on-site integration and troubleshooting
  • KEYENCE XG-8000 Line Scan Visual Debugging Guide
  • OMRON G9SX Security Unit Configuration and Troubleshooting
  • OMRON CPM1A Maintenance and Troubleshooting
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator