Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE ds200tccbg1a Extended Analog I/O Board
    ❤ Add to collection
  • GE ds200tccbg1a Extended Analog I/O Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE ds200tccbg1a Extended Analog I/O Board

    • ¥22000.00
      ¥24520.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.500KG
    • Quantity:
    • (Inventory: 33)
Description

GE ds200tccbg1a Extended Analog I/O Board


GE ds200tccbg1a Extended Analog I/O Board

Part Number ds200tccbg1a Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockDS200TCCBG1A is a Common Extended Analog IO Board manufactured and designed by General Electric as part of the Mark V Series used in Speedtronic Gas Turbine Control Systems. The Common Extended Analog I/O Board (TCCB) scales and conditions additional analog I/O signals that are read from the TCEB board in the P1 core and the TBCB terminal board installed on the R5 core. 

These signals consist of the line current inputs, RTDs, generator and bus voltage inputs, and 4-20 mA/0-1 mA inputs. Through the 3PL connector, the scaled and conditioned signals are delivered to the STCA board. CONFIGURATION: HARDWARE: The Mark V LM's generator and bus voltage monitoring functions, as well as the line current monitoring function, are provided by the hardware jumpers J1, J2, J3, J4, and J5. The RS232 serial port is linked to DCOM through hardware jumper J14. J15 and J16 are hardware jumpers that are used for testing. For details on the hardware jumper settings for this board, consult Appendix A and the operator interface's hardware jumper panel. SOFTWARE: The HMI's I/O Configuration Editor is where you enter the bus voltage and line current settings, as well as I/O configuration constants for the generator, mA inputs, RTDs, and other devices.

ABOUT THE DS200TCCBG1A

This DS200TCCBG1A TC2000 Analog Board was originally manufactured to exist as a member of General Electric's Mark V Series of turbine control systems. The Mark V Series is something of an aptly-named General Electric product series, as it exists possessing specific applications in the management and control systems of compatible, popular gas and steam turbine control and management systems. This DS200TCCBG1A TC2000 Analog Board is actually more accurately describable through its true functional description as a Common Extended Analog IO Board. The IO acronym in this functional description points to this DS200TCCBG1A printed circuit board's specific role as an Input/Output Board within the Mark V Series. While pertinent to some newer-developed turbine-minded applications, the Mark V Series that this DS200TCCBG1A PCB and other products here belong to has to be considered an obsolete product series as a whole, as it is truthfully a legacy product series discontinued for manufacture due to retailer-identified functional series-wide obsolescence in one of the years beyond its initial rollout.

Hardware Tips and Specifications

The GE I/O TC2000 Analog Board DS200TCCBG1A features one 80196 microprocessor and multiple PROM modules. It also contains one LED and 2 50-pin connectors, with the LED is visible from the side view of the board. The IDs for the 50-pin connectors used in the assembly of this DS200TCCBG1A board are JCC and JDD. The DS200TCCBG1A board also is populated with 5 34-pin connectors. The IDs for the five connectors are JAA, JBB, JAT, JAS, and JAR. Because the board contains multiple 34-pin connectors it is important to record where the ribbon cables are connected before you disconnect them. It is important to get the drive back online as quickly as possible and doing that requires making the right signal connections when you first replace the board and restart the drive. You might not know you have made the wrong connections until you have restarted the drive and find that the right signals are not being transmitted or received by the board. In that case, you can shutdown the drive and reconnect the ribbon cables. To disconnect the cables, avoid pulling the ribbon cable from the ribbon section of the cable. This will pull the fine copper strands out of the connector in a safe manner.

Some additional hardware specifications and component elements for this DS200TCCBG1A Common Extended Analog I/O Board are available simply upon an inspection of this product's individualized DS200TCCBG1A functional product number, which reveals informations such as this DS200TCCBG1A PCB's normal assembly type, domestic location of manufacture, TCCB functional acronym, normal PCB coating style, group one Mark V Series grouping, and lone A-rated functional revision. Luckily enough for the purposes of this DS200TCCBG1A personalized product page here, this DS200TCCBG1A device is surrounded with a something of a disproportionate amount of originally-designed original instrcutional manual materials online; likely a symptom of its Mark V Legacy Product Series attribution. With this in mind, this DS200TCCBG1A device's originally-provided connectors can be contextualized in terms of their functionalities. Each connector in this DS200TCCBG1A Common Extended Analog I/O Board's normal Mark V Series assembly will have been named through a unique amalgamation of their respective factory-printed nomenclature labels, their PIN numbers, and finally the specific style of Mark V Series signal that they were designed to transmit. This DS200TCCBG1A device's specific connectors include the:

2PL TCPS board Power Distribution Connector

3PL Data Bus between the STCA, TCCA and TCCB boards Connector

JHH 4-20 mA/0-1 mA input signalsTBCB terminal board Connector

JII RTD input signals from the TBCB terminal board Connector

JMP Potential and current transformer signals from the TCEB board Connector

JKK Connector

JTEST Connector

TCQPL Connector


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications
  • Bonfiglioli 300 series reducer installation, maintenance, and troubleshooting guide
  • Selection and integration guide for Bonfiglioli R3 series planetary gearboxes in primary crushing equipment
  • Bonfiglioli C-series ATEX gearbox selection and explosion-proof application guide
  • Bonfiglioli Vectron EM-ENC-05 Full Function Expansion Module Integration Guide
  • Bonfiglioli Vectron EM-ENC-04 Multi functional Expansion Module Complete Configuration Guide
  • Bonfiglioli Vectron EM-ENC-03 Second Encoder Interface and System Bus Expansion Guide
  • Bonfiglioli Vectron EM-ENC-02 Expansion Module Integration and Encoder Interface Guide
  • Bonfiglioli Vectron CM-CAN CANopen Communication Configuration and DS402 Control Guide
  • Bonfiglioli Vectron EM-SYS System Bus Networking and Virtual Link Configuration Guide
  • Bonfiglioli Vectron CM-PDP Profibus DP Configuration and Debugging Guide
  • Bonfiglioli Vectron CM-232/485 Modbus Communication Configuration Guide
  • Bonfiglioli BMS series servo reduction motor selection and integration guide
  • Bonfiglioli ACTION 210/410 Inverter Debugging and Fault Diagnosis Complete Guide
  • Honeywell Enhanced Micro TDC 3000X System Redundancy Architecture and Maintenance Guide
  • Selection and Configuration of Bonfiglioli Active Series Inverter
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli HDP/HDO Series Heavy duty Gearboxes
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli 300/300M Series Gearboxes
  • Bonfiglioli 300M planetary gearbox selection and thermal verification guide
  • Bonfiglioli 3/H series heavy-duty gearbox selection and verification guide
  • Bonfiglioli KRG/KCG/KSD Hydraulic Coupling Selection and Integration Guide