Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE ds200tccbg1a Extended Analog I/O Board
    ❤ Add to collection
  • GE ds200tccbg1a Extended Analog I/O Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE ds200tccbg1a Extended Analog I/O Board

    • ¥22000.00
      ¥24520.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.500KG
    • Quantity:
    • (Inventory: 33)
Description

GE ds200tccbg1a Extended Analog I/O Board


GE ds200tccbg1a Extended Analog I/O Board

Part Number ds200tccbg1a Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockDS200TCCBG1A is a Common Extended Analog IO Board manufactured and designed by General Electric as part of the Mark V Series used in Speedtronic Gas Turbine Control Systems. The Common Extended Analog I/O Board (TCCB) scales and conditions additional analog I/O signals that are read from the TCEB board in the P1 core and the TBCB terminal board installed on the R5 core. 

These signals consist of the line current inputs, RTDs, generator and bus voltage inputs, and 4-20 mA/0-1 mA inputs. Through the 3PL connector, the scaled and conditioned signals are delivered to the STCA board. CONFIGURATION: HARDWARE: The Mark V LM's generator and bus voltage monitoring functions, as well as the line current monitoring function, are provided by the hardware jumpers J1, J2, J3, J4, and J5. The RS232 serial port is linked to DCOM through hardware jumper J14. J15 and J16 are hardware jumpers that are used for testing. For details on the hardware jumper settings for this board, consult Appendix A and the operator interface's hardware jumper panel. SOFTWARE: The HMI's I/O Configuration Editor is where you enter the bus voltage and line current settings, as well as I/O configuration constants for the generator, mA inputs, RTDs, and other devices.

ABOUT THE DS200TCCBG1A

This DS200TCCBG1A TC2000 Analog Board was originally manufactured to exist as a member of General Electric's Mark V Series of turbine control systems. The Mark V Series is something of an aptly-named General Electric product series, as it exists possessing specific applications in the management and control systems of compatible, popular gas and steam turbine control and management systems. This DS200TCCBG1A TC2000 Analog Board is actually more accurately describable through its true functional description as a Common Extended Analog IO Board. The IO acronym in this functional description points to this DS200TCCBG1A printed circuit board's specific role as an Input/Output Board within the Mark V Series. While pertinent to some newer-developed turbine-minded applications, the Mark V Series that this DS200TCCBG1A PCB and other products here belong to has to be considered an obsolete product series as a whole, as it is truthfully a legacy product series discontinued for manufacture due to retailer-identified functional series-wide obsolescence in one of the years beyond its initial rollout.

Hardware Tips and Specifications

The GE I/O TC2000 Analog Board DS200TCCBG1A features one 80196 microprocessor and multiple PROM modules. It also contains one LED and 2 50-pin connectors, with the LED is visible from the side view of the board. The IDs for the 50-pin connectors used in the assembly of this DS200TCCBG1A board are JCC and JDD. The DS200TCCBG1A board also is populated with 5 34-pin connectors. The IDs for the five connectors are JAA, JBB, JAT, JAS, and JAR. Because the board contains multiple 34-pin connectors it is important to record where the ribbon cables are connected before you disconnect them. It is important to get the drive back online as quickly as possible and doing that requires making the right signal connections when you first replace the board and restart the drive. You might not know you have made the wrong connections until you have restarted the drive and find that the right signals are not being transmitted or received by the board. In that case, you can shutdown the drive and reconnect the ribbon cables. To disconnect the cables, avoid pulling the ribbon cable from the ribbon section of the cable. This will pull the fine copper strands out of the connector in a safe manner.

Some additional hardware specifications and component elements for this DS200TCCBG1A Common Extended Analog I/O Board are available simply upon an inspection of this product's individualized DS200TCCBG1A functional product number, which reveals informations such as this DS200TCCBG1A PCB's normal assembly type, domestic location of manufacture, TCCB functional acronym, normal PCB coating style, group one Mark V Series grouping, and lone A-rated functional revision. Luckily enough for the purposes of this DS200TCCBG1A personalized product page here, this DS200TCCBG1A device is surrounded with a something of a disproportionate amount of originally-designed original instrcutional manual materials online; likely a symptom of its Mark V Legacy Product Series attribution. With this in mind, this DS200TCCBG1A device's originally-provided connectors can be contextualized in terms of their functionalities. Each connector in this DS200TCCBG1A Common Extended Analog I/O Board's normal Mark V Series assembly will have been named through a unique amalgamation of their respective factory-printed nomenclature labels, their PIN numbers, and finally the specific style of Mark V Series signal that they were designed to transmit. This DS200TCCBG1A device's specific connectors include the:

2PL TCPS board Power Distribution Connector

3PL Data Bus between the STCA, TCCA and TCCB boards Connector

JHH 4-20 mA/0-1 mA input signalsTBCB terminal board Connector

JII RTD input signals from the TBCB terminal board Connector

JMP Potential and current transformer signals from the TCEB board Connector

JKK Connector

JTEST Connector

TCQPL Connector


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Yokogawa AIP830 Single Circuit Operation Keyboard
  • Yokogawa RAMC flowmeter selection and troubleshooting
  • YASKAWA GA500 frequency converter troubleshooting
  • TRACO TIS600 power supply
  • Sigmatek ETV-0851 Control Panel Troubleshooting
  • Allen Bradley Quest AN-X2-AB-DHRIO Remote I/O Adapter Integration and Troubleshooting
  • Meggitt RPS6U power supply
  • Kongsberg RCU500 Controller Integration and Fault Diagnosis Guide
  • KBAC series frequency converter installation and fault diagnosis guide
  • EXOR effectiveness View eV058 series HMI industrial panel
  • Emerson OCR3000 Controller Troubleshooting Guide
  • Emerson Ovation OCR1100 Controller Maintenance and Troubleshooting
  • Elmo G-TUB30 Driver Troubleshooting Guide
  • Troubleshooting and Optimization of Basler A400 Series Camera
  • Troubleshooting and Maintenance of Automated Logic I/O Expansion Module
  • Troubleshooting and Maintenance of Aerotech UNIDEX 100 Controller
  • ADVANEST R6144 calibration source troubleshooting
  • Troubleshooting and Calibration of ABB Millmate Tension Gauge
  • ABB NGC8206 natural gas chromatograph troubleshooting and maintenance
  • ABB AO2040-CU Ex Explosion proof Analyzer Troubleshooting
  • ABB PFEA113 Tension Controller Troubleshooting Guide
  • ABB PFEA111/112/122 Tension Controller Troubleshooting Guide
  • ABB LS4000 laser analyzer
  • ABB SPAU 341 C Voltage Regulator Troubleshooting Guide
  • Analysis and Fault Diagnosis of ABB V-Contact VSC Medium Voltage Contactor
  • ABB UNITOL 1020 Compact Digital Excitation Regulator AVR Replacement and Troubleshooting
  • ABB UNITROL 1000 excitation system replacement and troubleshooting
  • ABB SYNC HROTACT 5 synchronization module troubleshooting and replacement
  • ABB SYNC HROTACT 5 Synchronization Device Replacement and Troubleshooting Guide
  • ABB Symphony Plus Module Replacement and Upgrade Guide
  • ABB S900 I/O Hazardous Area Deployment and Maintenance
  • ABB System 800xA Operations and Troubleshooting
  • ABB PCS6000 Troubleshooting and Module Replacement Guide
  • ABB PCS 8000 pumped storage excitation
  • ABB Procontrol P13 Bus Coupling Upgrade Guide
  • ABB NextMove ESB-2 Fault Diagnosis and Configuration Practice
  • ABB MEGADRIVE-LCI Maintenance and Selection Practice
  • ABB MEGADRIVE LCI Transmission Vibration Suppression
  • ABB MEGADRIVE LCI Water Cooling Troubleshooting and Maintenance Guide
  • Practical Maintenance and Common Troubleshooting of ABB DCS880
  • ABB SDCS-IOB-3 Replacement and Troubleshooting
  • ALSTOM MAE99-04 Serial Interface Terminal Panel Maintenance and Troubleshooting
  • Installation and Maintenance of ALSTOM ALSPA MV3000 Handheld Operator
  • Maintenance and commissioning of ABB KPM KB2 paper breakage detector
  • Maintenance and troubleshooting of ABB SCC-K converter
  • ABB SCC Gas Preprocessing System Maintenance and Selection Guide
  • ABB NGC8209 gas chromatograph maintenance
  • Maintenance and troubleshooting of ABB DCS DC speed controller
  • ABB ASTAT Crane Controller Maintenance and Debugging Guide
  • ABB ACS800 TIM foil IGBT
  • ABB LS25 laser analyzer troubleshooting
  • ABB REM54 motor terminal troubleshooting
  • ABB REL670 distance protection and troubleshooting
  • ABB SUE3000 switching device troubleshooting
  • ABB REF630 feeder protection
  • ABB REF620 (Relion 620 series) feeder protection and measurement device
  • ABB E1B-A Circuit Breaker
  • ABB FCU400-IR temperature measurement system troubleshooting
  • ABB TZIDC-200 locator configuration and troubleshooting
  • ABB DHH805-A Handheld Operator Configuration and Activation Guide
  • ABB SACO 16D1 alarm device replacement and troubleshooting
  • ABB 5SHY3545L0016 IGCT module replacement guide
  • ABB S600 I/O Module Replacement and Troubleshooting Guide
  • ABB NextMove e100 motion controller troubleshooting guide
  • Rockwell PowerFlex 700 Inverter Replacement and Troubleshooting Guide
  • Allen Bradley 1762-OW16 Output Module
  • Allen Bradley IntelliVAC 1503VC Series E Control Module
  • Allen‑Bradley IntelliVAC ™ 1503VC contactor control module
  • Woodward SOGAV 250 solenoid valve drives gas intake valve for troubleshooting
  • Woodward easyYgen-3500XT-P1 obstacle removal
  • Woodward CPC-II electro-hydraulic current pressure converter
  • UniOP ePALM10 Handheld HMI
  • TMEIC TMdrive-30 frequency converter
  • TEWS TVME200 Carrier Board Configuration and Troubleshooting Guide
  • TDK Alpha 400 Power Troubleshooting Guide
  • STUCKE SYMAP relay
  • Deployment and troubleshooting of Softing CAN-AC2-PCI interface card
  • Installation, Maintenance, and Troubleshooting of Siemens C7-623/624
  • Foxboro Compact 200 Series 16 Slot Bottom Plate Deployment and Maintenance Guide
  • Foxboro 84F/84W Vortex Flow Meter Selection and Debugging Guide
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller
  • DATA PATTERNS DP-VME-5114 Dual PMC Carrier Board Integration and Troubleshooting
  • CMZ SVM1608 Intelligent Servo Driver
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide
  • SUMITOMO ELECTRIC AC1135U Small Parts Turning Application Guide
  • SUMITOMO ELECTRIC AC1030U Precision Machining Selection and Practice for Small Parts
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection
  • BENDER RCMA475LY Residual Current Monitoring
  • BENDER IRDH575 Insulation Monitoring
  • BENDER IRDH265 Insulation Monitoring and Debugging
  • Bender RCMA475LY residual current monitor debugging
  • Beckwith Electric M-3425A Generator Protection Relay Debugging Guide
  • Automated MEX816U Expander Troubleshooting Guide