Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE ds200tcqeg2a  I/O Processor Board
    ❤ Add to collection
  • GE ds200tcqeg2a I/O Processor Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE ds200tcqeg2a  I/O Processor Board

    • ¥22000.00
      ¥24520.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.600KG
    • Quantity:
    • (Inventory: 36)
Description

GE ds200tcqeg2a  I/O Processor Board


GE ds200tcqeg2a  I/O Processor Board

Part Number ds200tcqeg2a Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockDS200TCQEG2A is an LM 6000 IO Processor Board developed by GE under the Mark V series. The R1 core houses the LM 6000 IO Processor Board (TCQE), which scales and conditions extra analog I/O signals. These signals include magnetic pick up, TTL pulse rate inputs, LM vibration inputs, proximitor vibration inputs, proximitor position inputs, 420 mA outputs, RTD inputs, and 420 mA outputs. The STCA board receives data from the TCQE board via the 3PL connector. 

All LM applications use this board. The board scales and conditions Analog I/O Signals. It is located in the core. This board is used for all LM applications. It is populated with eight jumpers and four 34-pin connectors. This board also has one Programmable Logic Device and multiple EPROM modules. The JQQ connectors reads the LM vibration inputs, proximeter vibration inputs, and pulse rate speed sensor inputs.The component plays an important role in communicating data to the STCA board. 

Always adhere to the manufacturer's installation guidelines while installing or replacing the board. Since the DS200 series is obsolete,we suggest you have a shelf stock of minimum 2 cards of every panel. LVDT/LVDR Circuit TCQE LVDT/LVDR Circuit sLinear Variable Differential Transformers (LVDT) or Linear Variable Differential Reactors (LVDR) are used to detect position. The JLL connection is used to read the position signals from the TBQE terminal board. 

For usage by the Control Sequence Program, these location signals have been scaled and conditioned (CSP). The TCQE also performs diagnostics on these signals. Through the TCQC board, the excitation signals are written to the QTBA terminal board. The LVDT/Rs are commonly used for regulating servo valve outputs; although these are not associated with the TCQA/TCQC servo systems. DS200TCQEG2A Proximitor Vibration Inputs The JQQ connector is used to read the proximitor vibration inputs from the TBQE terminal board. The I/O configuration constants obtained from the operator interface are used to scale, condition, and process the signals. The results are written to the STCA board through the 3PL connector. 

 DS200TCQEG2A RTD Circuit The circuitry that feeds excitation to the RTDs from the TBQE terminal board is housed on the TCQE board. When the temperature varies, the resistance changes, causing the voltage on the RTD to change. A constant current is fed through the RTD. The voltage signal is measured, scaled, and adjusted by the TCQE board.

ABOUT THE ds200tcqeg2a

This DS200TCQEG2A printed circuit board was originally manufactured, as expressed above, by General Electric, for placement in their Mark V Turbine Control System Series. The Mark V Series that this DS200TCQEG2A PCB belongs to, as you may have been able to guess based on its full extended series name, has specific applications in the control and management systems of compatible wind, steam, and gas turbine automated drive assemblies, although it has to be considered a legacy product series due to its obsolescence-necessitated manufacturing discontinuation that took place in the many years since its original conception. While this DS200TCQEG2A printed circuit board is definable as an LM6000 I/O Processor Board in its own right, it is not the original product of this Mark V Series functionality; that would be the DS200TCQEG2 parent LM6000 I/O Processor Board missing this DS200TCQEG2A product offering's A-rated functional product revision. This DS200TCQEG2A printed circuit board's greater Mark V Series, while a legacy product series, is still well-updated given its status as one of the final General Electric product series to make use of the patented Speedtronic control system technology. This DS200TCQEG2A PCB's description as an LM6000 I/O Processor Board seems to assert this DS200TCQEG2A PCB's additional status within the Mark V's LM6000 subseries.

Hardware Tips and Specifications

The LM6000 I/O Processor Board DS200TCQEG2A is populated with 8 jumpers and 4 34-pin connectors. It also features one programmable logic device and multiple erasable programmable read-only memory modules (EPROMs). The IDs assigned to the 34-pin connectors are JQQ, 3PL, and JLL. The LM6000 I/O Processor Board DS200TCQEG2A also is populated with one LED that is mounted horizontally on the board. In terms of voltage limitation and suppression. this DS200TCQEG2A printed circuit board's voltage protections are handled by its internal assembly's adoption of a specific series of voltage-limiting hardware components standardized to the Mark V Series; including various rectifiers, capacitors, and integrated circuits. Luckily for the sake of this DS200TCQEG2A personalized product page, the DS200TCQEG2A PCB's internet-available instructional manual materials list all of its available connectors with contextual information about their functionality. Some of this DS200TCQEG2A PCB's connectors include:

The 2PL TCPS Power Distribution Connector

The 3PL Various Boards Data Bus Connector

The JJ TCQC Board Shaft Speed Signals Connector

The JJQ PTBA Board Shaft Speed Signals Connector

The JLL TBQE Board Input Signals Connector

The JO TCRA Board Shear Signals Connector

The JQQ TBQE Board Input Signals Connector


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications
  • Bonfiglioli 300 series reducer installation, maintenance, and troubleshooting guide
  • Selection and integration guide for Bonfiglioli R3 series planetary gearboxes in primary crushing equipment
  • Bonfiglioli C-series ATEX gearbox selection and explosion-proof application guide
  • Bonfiglioli Vectron EM-ENC-05 Full Function Expansion Module Integration Guide
  • Bonfiglioli Vectron EM-ENC-04 Multi functional Expansion Module Complete Configuration Guide
  • Bonfiglioli Vectron EM-ENC-03 Second Encoder Interface and System Bus Expansion Guide
  • Bonfiglioli Vectron EM-ENC-02 Expansion Module Integration and Encoder Interface Guide
  • Bonfiglioli Vectron CM-CAN CANopen Communication Configuration and DS402 Control Guide
  • Bonfiglioli Vectron EM-SYS System Bus Networking and Virtual Link Configuration Guide
  • Bonfiglioli Vectron CM-PDP Profibus DP Configuration and Debugging Guide
  • Bonfiglioli Vectron CM-232/485 Modbus Communication Configuration Guide
  • Bonfiglioli BMS series servo reduction motor selection and integration guide
  • Bonfiglioli ACTION 210/410 Inverter Debugging and Fault Diagnosis Complete Guide
  • Honeywell Enhanced Micro TDC 3000X System Redundancy Architecture and Maintenance Guide
  • Selection and Configuration of Bonfiglioli Active Series Inverter
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli HDP/HDO Series Heavy duty Gearboxes
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli 300/300M Series Gearboxes
  • Bonfiglioli 300M planetary gearbox selection and thermal verification guide
  • Bonfiglioli 3/H series heavy-duty gearbox selection and verification guide
  • Bonfiglioli KRG/KCG/KSD Hydraulic Coupling Selection and Integration Guide