Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE ds200tcrag2a Relay Output Board
    ❤ Add to collection
  • GE ds200tcrag2a Relay Output Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE ds200tcrag2a Relay Output Board

    • ¥22000.00
      ¥24520.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.600KG
    • Quantity:
    • (Inventory: 36)
Description

GE ds200tcrag2a Relay Output Board


GE ds200tcrag2a Relay Output Board

Part Number ds200tcrag2a Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockDS200TCRAG2A is a Relay Output Board manufactured by General Electric as part of the Mark V LM series used in gas turbine control systems. K1 through K30 relays are housed on the Relay Output Board (TCRA), which is part of the digital cores. In every digital IO core, there are two of these boards. Only four relays are present on the TCRA board in core location 4 and they are linked to the TCQE using the JO connector. In some applications, these relays are employed to activate the blow-off valves on gas manifolds. The entire complement of 30 relays is present in all other TCRAs. It is possible to arrange the first 18 relays on TCRA at location 4 to act as a power source for solenoids. 

This configuration is also possible for the TCRA board's initial 16 relays, which are located in location 5 of both the cores. Hardware jumpers on the DTBC and DTBD terminal boards are used to do this. On the TCRA board, position 5 of any or both of the power connections J19 and J20 can be used to wet- ted two extra contact outputs (#47 and #48). The DTBD board in one of the cores receives 120/240 V ac power through connectors J19 and J20 from the core. Usually, ignition transformers employ these signals. In the digital cores, the TCDA boards write the signals that instruct the relays to open or close to the TCRA boards. 

The TCQE board in the core is where the signals for the TCRA board in position four come from. You cannot configure the first 18 solenoid outputs to function as solenoid power sources. TCRA CONNECTIONS: JO - Writes the signals for Q11, Q21, and Q51 from the TCDA board to the TCRA board in location five. writes the TCDA board's signals to the TCRA board at position 4 of the Q21 and Q51 cores. controls the gas manifold blow-off valve by writing the signals from the TCQE board in the "R1" core to the "Q11" core's TCRA board at location four. JS1 - Relay outputs from the TCRA are connected to the DTBC/D terminal board. JS2 - Relay outputs from the TCRA are connected to the DTBC/D terminal board. JS3 - Relay outputs from the TCRA are connected to the DTBC/D terminal board. JS4 - Relay outputs from the TCRA are connected to the DTBC/D terminal board.

JS5 - Relay outputs from the TCRA are connected to the DTBC/D terminal board. JS6 - Relay outputs from the TCRA are connected to the DTBC/D terminal board. JS7 - Relay outputs from the TCRA are connected to the DTBC/D terminal board. JS8 - Relay outputs from the TCRA are connected to the DTBC/D terminal board. JOR/S/T - Not commonly used. TCRA CONFIGURATION: HARDWARE: The hardware configuration for the DTBC and DTBD terminal boards, which powers the relays or converts them to solenoids, takes place at the terminal board level. SOFTWARE: The TCRA board has not been configured with any software. 

 TCRA CONTACT OUTPUT CIRCUITS: Signals from the CSP are used to control the relays on the TCRA boards, which are then relayed to the STCA board through COREBUS and the IO Engines. The TCDA boards receive the signals from the STCA boards via the IONET after reading them. The instruction signals are then written by the TCDA board via the JO connector to energize the relays. The JS1 through JS8 connectors are used to connect the relay (open/close) to the DTBC and DTBD terminal boards.

ABOUT THE ds200tcrag2a 

General Electric model DS200TCRAG2A is part of the Mark V series, as mentioned above. The Mark V Series is a now-discontinued legacy series released by the trusted retailer General Electric that has specific applications in the internal assemblies of gas, steam, and wind turbine control and management systems. While a legacy series no longer catively produced by the manufacturer, the Mark V Turbine Control System Series is one of the newer General Electric product lines to feature the patented Speedtronic technology in its assembly, which was first introduced alongside the rollout of the first Mark I Series of General Electric printed circuit boards and other Mark system drive assembly components. While certainly generally definable as a GE printed circuit board, this DS200TCRAG2A PCB is better-definable as a Relay Output Board, the original functional product description it is referred to as in Mark V Series instructional manual documentation. The original Relay Output Board developed for the Mark V Turbine Control System Series is the DS200TCRAG2 parent PCB missing this DS200TCRAG2A product's A-rated functional product revision.

Hardware Tips and Specifications

This model was designed by General Electric as a Relay Output terminal board that operates in the Q11 and Q51 cores; there are two TCRA models within each I/O core. When the model has been mounted within the cores, it will be connected to the TCQE model through the JO connectors on the TCRA board. When the model is in the Q11 core, there are only four relays; the four relays are primarily used to operate the gas manifold blow-off valves in some applications. When the DS200TCRAG2A model has been mounted in the Q51 core, the first eighteen relays on the model will be configured to provide a power source to operate the solenoid outputs. To configure the relays, it will be done through the hardware jumpers on the DTBD and DTBC terminal boards connected alongside the TCRA board. While the TCRA model has a number of hardware configurations that are used to configure the model to the user's specifications, the model does not contain any software configurations. It should be noted that while this DS200TCRAG2A printed circuit board is offered alongside customization strategies encouraged by customizable hardware, the customizable hardware in question is not present in the assembly of this DS200TCRAG2A Relay Output Board itself; existing in the configurations of the related Mark V Series DTBC and DTBD terminal board products.

There are several connectors available on the DS200TCRAG2A model; some of them are as follows, JS5, JS6, JS7, and JS8. All of these connectors are used to connect relay outputs from this model to the DTBC or DTBD boards. When the TCRA model is used in the Q11 core, it will not be connected to the DTBC models. There are also the JOR/S/T connectors, but typically these connectors are not used by the TCRA model. All of the other connectors and their functions are listed in the fourth chapter of the GEH-6153 Instruction Guide, embedded above in the manuals tab. The DS200TCRAG2A functional product number itself reveals a litany of other DS200TCRAG2A board-specific hardware components and component specifications, as it was developed to serve this purpose by General Electric. Some of the information revealed through use of this DS200TCRAG2A functional product number includes this DS200TCRAG2A board's:

Domestic location of original manufacture

Normal Mark V Series assembly type

TCRA functional product acronym

Normal style of PCB protective coating

Group One Mark V Series grouping

A-rated functional product revision


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Atlas Copco Tensor STB Wireless Tightening Tool Deployment Guide
  • Atlas Copco Power Focus 4000 Configuration and Troubleshooting Manual
  • Atlas Copco Power Focus 6000 and Tensor STR System
  • Energy efficiency and selection of Atlas Copco ZR/ZT oil-free screw compressor
  • Atlas Copco PowerMACS 4000 Tightening Control System
  • Atlas Copco Elektronikon MK5 Controller Operation Guide
  • Atlas Copco Tensor ES and PF600 Tightening System
  • ADLINK STC2-AL/KL Industrial Control Tablet BIOS and Drivers
  • ADLINK STC-15W04 industrial tablet computer
  • ADLINK SP2-EHL Fanless Tablet Selection and Configuration Guide
  • ADLINK PXIS-2719A Chassis Deployment Monitoring Guide
  • ADLINK PXIe-9908 SMU Deployment and Configuration Guide
  • ADLINK PXIe-9852 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9848 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9834 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9529H Dynamic Signal Acquisition Configuration Guide
  • ADLINK PXIe-3988 Xeon Deployment Optimization Guide
  • ADLINK PXIe-3987/3977/3937 Deployment and Debugging
  • ADLINK PXIe-3987 Installation and Configuration Programming Guide
  • ADLINK-PXIe-3988-3987-3977-3937-TL Controller Deployment and Maintenance Guide
  • ADLINK PXI-2020/2022 Synchronous Acquisition Card Configuration and Synchronization Guide
  • ADLINK DAQ/PXI-2000 series synchronous acquisition card configuration and triggering
  • ADLINK PXES-2788 series chassis deployment and maintenance
  • ADLINK PXES-2785 18 Slot Gen3 Chassis Deployment and Maintenance Guide
  • ADLINK PXES-2780 18 Slot PXIe Chassis Deployment Configuration
  • ADLINK PXES-2596 Gen3 Chassis Installation and Maintenance Guide
  • ADLINK PXES-2590 Chassis Deployment and System Management
  • ADLINK PXES-2314T Chassis Deployment and Troubleshooting Guide
  • ADLINK PXES-2301 Chassis Installation Monitoring and Troubleshooting
  • ADLINK PCIe-U300 Series USB3 Vision Acquisition Card Deployment Guide
  • ADLINK PCIe PXIe-8565 Expansion Kit Remote Control and Compatibility
  • Installation and troubleshooting of ADLINK PCIe GIE74V four channel PoE acquisition card
  • ADLINK PCIe GIE7x Poe+Acquisition Card Configuration and Triggering Troubleshooting
  • Advanced triggering and multi card synchronization of ADLINK PCIe-CPL64V image acquisition card
  • ADLINK PCIe-CPL64 Image Acquisition Card Hardware Trigger and Encoder Application
  • Application and troubleshooting of ADLINK PCIe-8560/PXI-8565 expansion kit
  • ADLINK PCIe 8332/PCIe 8334/PCIe 8338 EtherCAT Motion Controller Multi axis Synchronous Control
  • ADLINK PCIe-7432 32 channel isolated I/O card interrupt and driver
  • ADLINK PCIe-7256 Industrial I/O Card Interruption and Relay
  • ADLINK PCIe-833x EtherCAT Motion Controller Debugging and Maintenance
  • ADLINK PCIe-10GPoE 10GigE Visual Acquisition Card Practical Use
  • ADLINK PCI-8254/8258 Motion Controller Debugging and Maintenance
  • Application and Maintenance of ADLINK PCI-8158 Multi axis Motion Control Card
  • ADLINK PCI-8134A Maintenance and Troubleshooting Guide
  • ADLINK PCI-7250 Series Relay Output Card Configuration and Protection Circuit Guide
  • ADLINK PCI-6308 Series Isolated Analog Output Card Configuration and Programming
  • ADLINK PanKonix Series HMI Panel Selection and Deployment Guide
  • ADLINK NuDAM-6100 Series I/O Module Deployment and Protocol Optimization
  • Deployment and Calibration of ADLINK NuDAM-6000 Data Acquisition Module
  • ADLINK NEON-2000-Ono Intelligent Camera Deployment and Trigger Optimization
  • ADLINK NuDAM-65xx Communication Module Networking and Configuration Guide
  • ADLINK NuDAM-60xx Series Digital I/O Module Deployment and Watchdog Optimization
  • ADLINK MXE-5300 Fanless Industrial Control Computer Deployment and Troubleshooting Manual
  • ADLINK MXE-310 edge computing Platform Hardware Installation and BIOS Tuning
  • ADLINK MXE-230 series Alder Lake platform industrial computer deployment and maintenance manual
  • ADLINK MXE-210 Compact Fanless Industrial Control Computer Hardware Deployment and Debugging Guide
  • ADLINK MXC-3300/3340 Embedded Industrial Control Computer Hardware Integration and Debugging Manual
  • ADLINK MXA-312M Edge AI Platform Hardware Integration and Debugging Guide
  • ADLINK MXA-200 IoT Gateway Hardware Installation and Linux System Debugging Complete Guide
  • ADLINK MVP-6200 Industrial Control Computer: PCIe Gen4 and PCI Hybrid Expansion
  • ADLINK MVP-6100 Industrial Control Computer: PCI/PCIe Expansion and Robust Design
  • ADLINK MVP-5200 Industrial Control Computer: High Performance Multi Display and TSN Network
  • ADLINK MVP-5100 Fanless Industrial Control Computer Deployment and Development Guide
  • ADLINK MVP-3100 and MVP-3120 Embedded Systems
  • ADLINK MNET-J3/S23/MIA/DA2/SAN Single Axis Module Installation and Wiring Guide
  • ADLINK MNET-4XMO/C Motion Module Installation and Debugging Guide
  • ADLINK MCM-216/218 Edge DAQ Deployment Configuration Guide
  • ADLINK LPCIe-8124-C Encoder Card Trigger Configuration Guide
  • ADLINK IM/OM Series Industrial Display Installation and Debugging Guide
  • ADLINK GW-01 Industrial IoT Gateway Configuration and Debugging Guide
  • EURESYS Grablink Collection Card Selection and Trigger Configuration Guide
  • ADLINK Express HL Module Selection and Heat Dissipation Configuration Guide
  • ADLINK EOS-2000 Visual System Installation and Troubleshooting
  • ADLINK EOS-1200 Installation, Configuration, and Troubleshooting
  • Application and Configuration of ADLINK ECS-8582-4S Extension System
  • ADLINK DIN-814P-A4 Panasonic servo adapter board configuration
  • ADLINK DIN-814M-J3A Mitsubishi servo adapter board configuration
  • ADLINK DIN-814-GP Universal Adapter Board Configuration
  • Application and Configuration of ADLINK DIN-812M Adapter Board
  • Application and Configuration of ADLINK DIN-814Y Adapter Board
  • ADLINK DAQ/DAQE/PXI-250x waveform generation complete guide
  • ADLINK DAQ/DAQE/PXI-220x acquisition card fully configured
  • Application and Configuration of ADLINK cPCI-9116 Data Acquisition Card
  • ADLINK cPCI/PCI-8554/R: A Complete Guide from Architecture to Application
  • ADLINK cPCI-7432/7433/7434 isolated I/O card
  • ADLINK cPCI-3544/3534/3538 Serial Cardcard Configuration Practice
  • ADLINK cPCI-3534/3538/3544 Multi Serial Port Card Configuration Complete Solution
  • Complete Technical Guide for Euresys Coaxlink CXP Capture Card
  • ADLINK AMP-304C Advanced Motion Control Card Complete Guide
  • ADLINK AMP-104C Four Axis Motion Control Card
  • ADLINK NEON-1020/1040 Smart Camera
  • ADLINK USB-7230/7250 Isolation I/O Module Operation Manual
  • ADLINK SP-15W03 Intelligent Panel Integration and Configuration Manual
  • ADLINK AMP-20xC Interface Configuration and Wiring Guide
  • ADLINK 3488A GPIB Interface Card Selection Guide
  • Complete solution of ETEL TMB+torque motor selection parameters
  • ADLINK RTV series frame grabber deployment guide
  • ADLINK PCIe-FIW64/62 Image Acquisition Card Configuration Guide
  • ADLINK 6208/6216-GL Analog Output Card
  • ADLINK 723X Isolation I/O Card Configuration Guide
  • ADLINK PCI-9118 series high-speed DAQ card selection and DMA configuration
  • ADLINK PCI-9114 (A) Data Acquisition Card Selection and Configuration Guide
  • ADLINK PCI-7442/7443/7444 Isolation I/O Card Selection and Safety Configuration
  • ADLINK PCI-7250/7251 Relay Output Card Selection and Expansion Guide
  • Selection and Protection Configuration of Advantech PCI-1610CU Multi Serial Port Card
  • ADLINK NEON-1000-MDX Smart Camera Deployment and Trigger Configuration
  • ADLINK MXE-1300 Industrial Control Computer Selection and Deployment Guide
  • ADLINK MXE-200 Industrial Control Computer Deployment and BIOS Optimization Guide
  • ADLINK LPCIe-3488A GPIB Card Installation and Configuration Guide
  • Guidelines for Key Technologies of ETEL LMG/LMS Linear Motor Integration
  • ETEL IL+/LM Linear Motor Selection and Integration Guide
  • ETEL DSCDP/DSCDL/DSCDM Dual Axis Controller Debugging Guide
  • ETEL DSCDL Dual Axis Controller Hardware Integration Guide
  • ETEL DSB2P Series Servo Amplifier Connection and Configuration Guide
  • ETEL DSC2P/DSC2V Servo Controller Debugging Guide
  • DFI HD636-H81CS Industrial Motherboard Deployment and Debugging
  • Integration and Optimization of ADLINK DAQ-20xx Synchronous Acquisition Card
  • ADLINK cPCI-6530 Core i7 Blade Computer Deployment Guide
  • ADLINK cPCI-3610 Blade Computer Integration and Debugging
  • ADLINK AMP-204C/208C Troubleshooting Guide
  • ADLINK AmITX ALN Industrial Motherboard Characteristics and Application Analysis
  • ADLINK NuPRO-850 Motherboard Installation and Configuration Guide
  • ADLINK MI-965 Motherboard Installation and BIOS Configuration Guide
  • ADLINK M-302 Industrial Motherboard Installation and BIOS Optimization Guide
  • ADLINK PXI-3920/3910 Controller Installation and Configuration Guide
  • ADLINK PCI-8132 Motion Control Card Installation, Programming, and Debugging Guide
  • ADLINK cPCI-6760D/P7/P8 Module Installation and Hot Plug Guide
  • ADLINK ACL-7122 Digital I/O Card Installation and Programming