Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE DS200TCRAG1A Relay Output Board
    ❤ Add to collection
  • GE DS200TCRAG1A Relay Output Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE DS200TCRAG1A Relay Output Board

    • ¥22000.00
      ¥24520.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.600KG
    • Quantity:
    • (Inventory: 36)
Description

GE DS200TCRAG1A Relay Output Board


GE DS200TCRAG1A Relay Output Board

Part Number DS200TCRAG1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark V Function Module Availability In StockDS200TCRAG1A is a Relay Output Board manufactured and designed by General Electric as part of the Mark V LM Series used in GE Speedtronic turbine control systems. Up to 30 relays, designated K1 through K30, are housed on the TCRA, which is part of the digital cores. 

The digital IO cores each contain two of these boards. Only four relays are present on the TCRA board at position 4 of the Q11 core, and they are linked to the TCQE by the JO connector. Some applications employ these relays to control the gas manifold blow-off valves. Thirty relays are present in every other TCRA. To supply a power source to operate solenoids, the first 18 relays on TCRA in location 4 of "Q51" can be configured. This configuration is also possible for the first 16 relays on the TCRA board in position 5 of the Q11 and Q51 cores. On the DTBC and DTBD terminal boards, hardware jumpers are used to do this. Using the power connectors J19 and J20, two extra contact outputs (#47 and #48) can be wetted on the TCRA board in position five of either Q11 or Q51. 

The DTBD board in one of the cores receives 120/240 V ac power through connectors J19 and J20 from the PD core. For ignition transformers, these signals are typically employed. The TCDA boards in the digital cores write the signals to the TCRA boards that instruct them to open or close the relays. The TCQE board in the "R1" core sends signals to the TCRA board at position 4 of "Q11" in this manner. Q21's first 18 solenoid outputs are ineligible to be configured as solenoid power sources. 

 TCRA CONFIGURATION: HARDWARE: The hardware configuration for the DTBC and DTBD terminal boards is done at the terminal board level, which powers the relays or converts them to solenoids. SOFTWARE: The TCRA board does not have any software configuration. TCRA CONTACT OUTPUT CIRCUITS: Signals from the CSP are used to control the relays on the TCRA boards, which are then relayed to the STCA board through COREBUS and the IO Engines. 

The TCDA boards receive the signals from the STCA boards via the IONET after reading them. The instruction signals are then written by the TCDA board via the JO connector to energize the relays. The JS1 through JS8 connectors are used to connect the relay (open/close) to the DTBC and DTBD terminal boards.

ABOUT THE DS200TCRAG1A

Hardware Tips and Specifications

This DS200TCRAG1A product offering is a printed circuit board that makes use of its own series of hardware component inclusions and specifications to achieve a functional Mark V Series status. The GE Relay Output Board DS200TCRAG1A is populated with 30 plug-in relays. It also has 4 34-pin connectors and 4 12-pin connectors. The IDs assigned to the 34-pin connectors in this DS200TCRAG1A PCB's assembly are JOR, JOS, JOT, and JO. The IDs assigned to the 12-pin connectors are JS3, JS4, JS5, and JS6.  Because the GE Relay Output Board DS200TCRAG1A is populated with multiple relays which are delicate and easily broken off the board, it is important that you follow guidelines for handling the DS200TCRAG1A board when it is shipped to you. Hardware configuration is possible for this DS200TCRAG1A Relay Output Board, encouraged by the use of several manually-moveable hardware jumpers. These hardware jumpers, however, do no feature in the assembly of the DS200TCRAG1A Relay Output Board itself, instead existing on related Mark V Series terminal boards DTBC and DTBD, which are also available for repair and replacement through AX Control. This DS200TCRAG1A Relay Output Board has a normal Mark V Series assembly version, which is populated with many of the various streamlined hardware components standard to this turbine control system series; such as various rectifiers, diodes, capacitors, and resistors. One specifically-highlightable hardware component in this DS200TCRAG1A product's assembly is its set of various integrated circuits, which are described in detail in the above attached instructional manual. Some of the connectors in this DS200TCRAG1A PCB's assembly include:

The JO TCDA Board Gas Manifold Signal Connector

The JS1-JS8 DTBC/D Boards Relay Output Connectors

The JOR/S/T Connector

All of these previously-listed connectors important to the assembly of this DS200TCRAG1A Relay Output Board have been named through a combination of their specific application to the DS200TCRAG1A board, interfacing potentials, and factory-printed nomenclature labels, except for the above JOR/S/T Connector, which has not been named as such given the fact that it typically goes unused during normative functionality of this TCRA-abbreviated printed circuit board product offering. All of the connections made to the base board of the DS200TCRAG1A Relay Output board should receive at least some level of base protection from the thick, rudimentary daily wear and tear protection afforded to this DS200TCRAG1A PCB by its normal style of General Electric printed circuit board coating. Before making a final purchase decision on this DS200TCRAG1A Relay Output Board, it is important to be cognizant of the fact that its originally-introduced performance specifications and dimensions have been more than likely impacted as a function of this DS200TCRAG1A PCB's addition of a singular A-rated functionality-enhancing product revision.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Advantest R6144 Programmable DC Voltage/Current Source (Calibration Source) Calibration and Maintenance
  • Aerotech UNIDEX 100/U100i single axis motion controller
  • Aerotech Ndrive MP Ultra Compact PWM Digital Servo Driver
  • Aerotech Ndrive HPe 10/20/30 High Performance PWM Digital Servo Drive
  • Aerotech Ndrive HLe maintenance replacement
  • Aerotech Ndrive CP maintenance replacement
  • Aerotech Ndrive Linear Drive Selection
  • Aerotech NDrive HL linear drive maintenance replacement
  • Aerotech NDrive HP 10/20/30 Maintenance and Replacement
  • Aerotech NDrive CP10 Servo Drive Guide
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications
  • Bonfiglioli 300 series reducer installation, maintenance, and troubleshooting guide
  • Selection and integration guide for Bonfiglioli R3 series planetary gearboxes in primary crushing equipment
  • Bonfiglioli C-series ATEX gearbox selection and explosion-proof application guide
  • Bonfiglioli Vectron EM-ENC-05 Full Function Expansion Module Integration Guide
  • Bonfiglioli Vectron EM-ENC-04 Multi functional Expansion Module Complete Configuration Guide
  • Bonfiglioli Vectron EM-ENC-03 Second Encoder Interface and System Bus Expansion Guide
  • Bonfiglioli Vectron EM-ENC-02 Expansion Module Integration and Encoder Interface Guide
  • Bonfiglioli Vectron CM-CAN CANopen Communication Configuration and DS402 Control Guide
  • Bonfiglioli Vectron EM-SYS System Bus Networking and Virtual Link Configuration Guide
  • Bonfiglioli Vectron CM-PDP Profibus DP Configuration and Debugging Guide