Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE ds2020expsg3 Exciter Power Supply Module
    ❤ Add to collection
  • GE ds2020expsg3 Exciter Power Supply Module

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE ds2020expsg3 Exciter Power Supply Module 

    • ¥22000.00
      ¥24520.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.600KG
    • Quantity:
    • (Inventory: 36)
Description

GE ds2020expsg3 Exciter Power Supply Module 


GE ds2020expsg3 Exciter Power Supply Module 

Part Number ds2020expsg3 Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockDS2020EXPSG3 is an exciter power supply board developed by GE under the EX2000 series. It generates the necessary signals for measuring alternating current and direct current input power. When the supply is powered by the station battery, it also acts as a current limiter. The automatic voltage regulators and excitation systems of the EX2000 series are used in a wide range of turbine-generator applications. 

The EX2000 Excitation Control System is a sophisticated platform for generator excitation. Jumpers JP1 identifies a manually moveable hardware jumper on the EXPS. JP1 connects the Tl secondary's center tap to ground. DS2020EXPSG3 Board Replacement Procedure Switch off the power. To replace the EXPS board, the entire bulk power supply must be removed. Check for zero potential at all power supply assembly connections. To remove the power supply assembly, carefully disconnect the following connectors: Unplug the lFTB, 1TB-8TB, DCTB, VM2A, and VM2B connectors as needed. Disconnect the black and white wires on the CPS PTBl and PTB2 terminal boards. Unplug the ACPL. Remove the power supply assembly from the cabinet by carefully loosening the four assembly mounting screws. ACPL should not be removed. 

Transfer the assembly to a workbench and remove the four screws that hold the plastic protective cover in place. Unplug the DCPL, 3GDPL, and 4GDPL connectors from the EXPS board. Replace the old EXPS board with the new EXPS board. Set JPl on the replacement (new) board to the same position as on the board being replaced (old board). Reconnect the connectors that were removed in step 5. Replace the protective plastic cover and screws. Replace the power supply assembly in the cabinet. Reconnect the connectors that were removed in step 3. The cables are labeled with the connector name as it appears on the board. Reconnect all cables in the order they were removed. Check that the cables are properly seated on both ends. 

 DS2020EXPSG3 Features The board is divided into three major components. A metal base with an attached circuit board, a second metal tier with an attached circuit board, and a plexiglass shield are among them. Each tier's circuit boards communicate with one another via surface-mounted electrical connections. The plexiglass shield is detachable and screws to the surface of the second layer. It has a prominent warning label that warns of the dangers of electrical shock or burns if the device is mistreated. The bottom metal carrier is constructed with two top hat flanges that have each been drilled twice to allow the unit to be readily installed in position. A two-by-two terminal strip is installed in one corner of the metal carrier.

ABOUT THE DS2020EXPSG3

The DS2020EXPSG3 is a power supply module fabricated by GE for use within their Speedtronic Mark V Turbine Control System Series. The Mark V Series that this DS2020EXPSG3 product offering belongs to, as evidenced by the above-attached full extended series name, has specific applications in the control and management systems of compatible and popular wind, gas, or steam turbine automated drive assemblies. While GE no longer manufactures these boards as they exist as a member of a now-obsolete legacy series, they are available through AX Control as reconditioned and fully tested modules. The Mark V Series that this DS2020EXPSG3 Exciter Power Supply Module belongs to is one of the later Mark Series offered by General Electric that features their patented Speedtronic control system technology, with the series being specially applicable to the control and management systems of gas, steam, and wind turbines. The DS2020EXPSG3 Power Supply Module is considered the original Mark V Turbine Control System Series product of its exact functionality to feature in its related automated drive assembly, as no significant product revisions have been made to its assembly.

Hardware Tips and Specifications

The DS2020EXPSG3 is an Exciter Power Supply Module for the EX2000 brushless generator excitation subsystem within the greater Mark V Turbine Control System Series. The DS2020EXPSG3 has three primary sections; these include a large metal base with an attached circuit board, a second metal tier with an attached circuit board, and a plexiglass shield. The circuit boards on each tier of this DS2020EXPSG3 modular assembly communicate with each other via surface mounted wired connections. The plexiglass shield screw mounts to the surface of the second tier of the DS2020EXPSG3 assembly and is removable. It carries a large warning label stating the dangers of electrical shock or burns if the unit is mishandled. The special modular assembly style unique to this DS2020EXPSG3 Power Supply Module is indicated in the DS2020EXPSG3 functional product number through the inclusion of the DS2020 special assembly series tag. Some of the other information revealed in this DS2020EXPSG3 product number includes this DS2020EXPSG3 module's domestic location of original manufacture, its EXPS functional product acronym, its normal style of printed circuit board protective coating, and its group three Mark V Turbine Control System Series grouping. 


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • DEIF TCM-2 thyristor control module: Wind power cut in control engineering guide
  • DEIF MVR-200 Medium Voltage Relay: Installation and Wiring Engineering Guide
  • DEIF MDR-2 Differential Relay: Engineering Guide for Generator Differential Protection
  • DEIF Delomatic 3 AOM: Engineering Guide for Analog Output Modules
  • DEIF AGI 400 Graphic Interface: Ship and Industrial HMI Solution
  • DEIF BRW-1 Marine Instruments: Installation and Calibration Guide for Offshore Bridge Indicators
  • DEIF AGC 200 Controller: Quick Deployment and Configuration Guide for Generator Sets
  • DEIF AGC-2 Controller: The Ultimate Guide to Automatic Control and Protection of Generator Sets
  • ABB SPA-ZC400 Gateway: REM54x Access to IEC 61850 Ultimate Engineering Guide
  • ABB REM 543/545 Terminal
  • Modular Architecture Analysis of DEIF PPU 300 Ship Generator Controller
  • DEIF DM-4 Marine&Offshore Ship Power Management System
  • Detailed Explanation of DEIF Delomatic Generator Control System Architecture
  • DEIF AGC-4 Mk II Generator Controller Depth Configuration Guide
  • DEIF AGC-4 Generator Controller Configuration and Debugging Guide
  • DEIF PPM Power Management System Operation and Troubleshooting
  • Installation and wiring of DEIF Multi line 2
  • Practical configuration and maintenance of Beckwith M-6280 capacitor bank controller
  • Beckwith M-3311 Transformer Protection Relay Setting and Engineering Application
  • Beckwith M-3311A Transformer Protection Relay Configuration and Optimization Guide
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit
  • Installation and I/O configuration of DEIF PPM-3 power management module
  • Beckwith M-3520 Interconnection Protection Relay
  • Beckwith M-3430 Generator Protection Relay
  • Beckwith M-2293B adapter panel replacement GE regulator guide
  • Selection and Networking of Beckwith M-2001C Digital Voltage Regulating Controller
  • Beckwith M-2001B Digital Voltage Regulating Controller
  • Beckwith M-0388/M-0389 Synchronous Inspection Relay Application Guide
  • Beckwith M-0193B Synchronizer Debugging and System Integration Guide
  • Beckwith M-0115A Parallel Balance Module Debugging Guide
  • Beckwith M-0067E On Load Voltage Regulating Controller Selection and Debugging Guide
  • Debugging and Fault Handling of Beckwith M-4272 Digital Busbar Conversion System
  • Beckwith M-3311A Transformer Protection Relay Debugging Guide
  • Beckwith M-3425A Generator Protection Relay Debugging Guide
  • Setting and troubleshooting of Basler BE1-27/59 voltage relay
  • Debugging and troubleshooting of Basler AVC63-12/AVC125-10 voltage regulator
  • Basler L301kc Line Array Camera Technology and Troubleshooting
  • Selection and Debugging of Basler CBS 212A Current Boosting System
  • Selection and commissioning of Basler BE3-25 synchronous inspection relay
  • Basler BE1-32R/32O/U Direction Power Relay Setting and Testing Guide
  • Basler PRS 250 Synchronous Relay Maintenance and Replacement Guide
  • Basler piA2400-17gc Industrial Camera Replacement and Optimization Guide
  • Basler BE1-11g Generator Protection System
  • Basler VR63-4C/UL Voltage Regulator
  • Basler BE1-DFPR feeder protection relay
  • Basler CBS 310/320 Current Boosting System
  • Basler UFOV 250A/260A protection module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F Regulator
  • Basler DECS-400 excitation system
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection
  • Basler SSR Static Voltage Regulator: A Complete Guide to Debugging and Troubleshooting
  • Basler SR4A/SR8A Voltage Regulator: Detailed Debugging and Troubleshooting Explanation
  • Basler BE2000E Voltage Regulator: Replacement and Application Details
  • Basler DECS-2100 Excitation System: Modular Upgrade and Engineering Application
  • Basler BE1-851 Overcurrent Protection System: A Complete Guide to Professional Debugging and Troubleshooting
  • Basler APR 63-5 Voltage Regulator: Professional Debugging and Troubleshooting Guide for Industrial Generator Excitation Systems
  • Basler BE1-FLEX Protection System: A Complete Guide to Professional Installation, Configuration, and Troubleshooting
  • Debugging and Testing of Basler BE1-700 Relay
  • Basler BE1-87B busbar differential setting test
  • Basler BE1-40Q demagnetization relay setting test
  • Basler BE1-60 Voltage Balance Relay Setting Test
  • Basler BE1-47N Relay Field Setting and Testing Guide
  • Basler BE1-81O/U Frequency Relay: On site Debugging and Protection Configuration Guide
  • Basler BE1-11f Feedline Protection System Debugging and Troubleshooting Guide
  • Basler DECS-250 Excitation System: Installation, Configuration, and Troubleshooting Practice Guide
  • Basler DECS-100 Digital Excitation System Debugging Guide
  • Application Guide for Basler BE1-BPR Circuit Breaker Protection Relay
  • Basler BE1-50/51B-255 Replacement CO Relay Guide
  • Basler BE1-25 synchronous inspection relay principle and testing
  • Basler BE1-51 Time Overcurrent Relay Debugging Guide
  • Practical Guide to Basler DECS-300 Digital Excitation System
  • Mitsubishi FX Series PLC Data Communication Practical Manual
  • Selection of Hirschmann cSCALE S6/C8 Mobile Safety Controller
  • Hirschmann OZD Profi G12D repeater explosion-proof installation configuration
  • Hirschmann OCTOPUS OS20/24 Switch Installation Power Supply
  • Hirschmann RS20/30/40 Switch Selection and PoE Deployment
  • Hirschmann EAGLE One Firewall Installation and Configuration Guide
  • Hirschmann MACH102 Switch Installation and Power Supply Guide
  • Hirschmann MICE MS20/MS30 Installation and DIP Configuration
  • Hirschmann BOBCAT BRS Switch Installation and Power Supply Guide
  • Hirschmann RSB20 Switch Deployment and Redundant Configuration
  • Hirschmann RS20 Basic Switch Installation and Debugging Guide
  • BECKHOFF EP20xx/EP28xx Output Module Installation and Debugging Guide
  • BECKHOFF EL5102 Encoder Terminal Debugging and Troubleshooting
  • BECKHOFF CU8803 Launch Box Installation and Explosion proof Guide
  • BECKHOFF CU20xx/CU22xx Switch Installation and Troubleshooting
  • BECKHOFF AMP8000 Servo Drive Installation and Debugging Manual
  • BECKHOFF EL2911 Safety Feed Terminal Debugging Guide
  • BECKHOFF EL600x/EL602x Serial Port Module Debugging Manual
  • BECKHOFF CP6700 Panel PC Installation and Maintenance Manual
  • BECKHOFF CP70xx panel maintenance and troubleshooting
  • BECKHOFF CP29xx Panel Installation and Troubleshooting
  • Beckhoff C6650-0060 Industrial Control Computer Hardware Architecture and RAID Data Security
  • Beckhoff BK1120/BK1250 EtherCAT Coupling Debugging and KL Terminal Parameterization Complete Guide
  • Beckhoff CX20x0 Embedded Controller Hardware Maintenance and Troubleshooting Complete Manual
  • Beckhoff CP77xx Panel PC Hardware Maintenance and Troubleshooting Complete Guide
  • Beckhoff EL41xx Analog Output Terminal Deep Analysis: Parameter Configuration, Fault Diagnosis, and Firmware Compatibility Guide
  • Beckhoff C63xx industrial computer power supply and shutdown configuration
  • Beckhoff C6920 Industrial Control Computer Selection and Expansion Guide
  • Beckhoff CU8800 USB extender diagnostic guide
  • Beckhoff AX2000 Shutdown Braking and Debugging
  • Beckhoff AX8000 servo installation fuse selection
  • Beckhoff CP27xx Multi finger Touch PC Maintenance
  • Beckhoff CP69xx long-distance transmission and installation
  • Beckhoff CP60xx remote deployment and maintenance
  • Beckhoff CP72xx Installation and Maintenance Complete Manual
  • Beckhoff CP78xx Installation and Troubleshooting Guide
  • Beckhoff CP39xx Control Panel
  • Beckhoff CX8110 Embedded PC
  • Beckhoff CX50x0 series DIN rail embedded industrial PC
  • Beckhoff CP62xx panel PC
  • BECKHOFF C6030 Industrial Control Computer
  • UniOP ePAD32B/ePAD33B/ePAD33BT Industrial HMI
  • UniOP ePAD05/06 Human Computer Interface
  • UniOP ePAD03/04 Human Computer Interface
  • UniOP BKDR-46-0045 Human Machine Interface
  • UniOP BKDR-16 human-machine interface
  • Beckwith M-3425A Relay Guide
  • Basler DECS-200-2L excitation system
  • Basler DECS-250 Excitation System Debugging Guide
  • HA-800A Servo Drive Debugging Guide
  • JUMO dTRANS p35 Manual